1.Optimization of Quality Standards for Polygalae Radix Based on Characteristic Chromatograms and QAMS for Xanthones
Humin XIE ; Xiaoqing CUI ; Weihong FENG ; Yu LU ; Xiaoqian LIU ; Xiaoli SUN ; Yanrong LI ; Zhimin WANG ; Chun LI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):196-204
ObjectiveTo address the limitations of the current quality standard for Polygalae Radix(PR), which relies on a single component for quality assessment and struggles to holistically control its intrinsic quality, by constructing a comprehensive quality evaluation system integrating "macro-characterization of chemical profile, synchronous quantification of multiple index components, and quantitative analysis of multi-components by single marker(QAMS) for key component groups". This study aims to facilitate the scientific revision of the quality standard for PR. MethodsHigh performance liquid chromatography(HPLC) characteristic chromatograms were established for 11 batches of PR medicinal materials(YZ), 10 batches of PR decoction pieces(YP), and 10 batches of licorice-processed PR decoction pieces(ZYZ), followed by similarity evaluation and identification of common peaks. HPLC-QAMS was developed for xanthones(sibiricaxanthone B, polygalaxanthone Ⅺ, polygalaxanthone Ⅲ) in the characteristic chromatograms. Simultaneously, the external standard method(ESM) was used to determine the contents of the corresponding xanthones and 3,6'-disinapoyl sucrose in YZ, YP, and ZYZ, followed by multivariate statistical analysis and Spearman correlation analysis. ResultsThe similarity between the characteristic chromatograms of 31 batches of PR samples and the reference chromatogram was>0.9. A total of 13 common peaks were identified, and 10 of these peaks were characterized through reference standard comparison. The successfully constructed QAMS method showed that the relative correction factors(RCFs) of sibiricaxanthone B and polygalaxanthone Ⅺ to polygalaxanthone Ⅲ were 0.76 and 0.88, and their relative retention times(RRTs) were 0.85 and 0.97, respectively. The results calculated by the QAMS method showed no significant difference from those obtained by the ESM. According to the limit standard for polygalaxanthone Ⅲ in the 2020 edition of the Pharmacopoeia of the People's Republic of China(hereinafter referred to as the Chinese Pharmacopoeia), the pass rate of 31 batches of samples was only 19.35%. Multivariate statistical analysis indicated certain compositional differences between different batches of YZ and YP, as well as between YP and ZYZ, with 3,6'-disinapoyl sucrose identified as the main differentiating component. Furthermore, correlation analysis revealed that the content of polygalaxanthone Ⅲ was positively correlated with the contents of sibiricaxanthone B and polygalaxanthone Ⅺ, but showed no association with the content of 3,6'-disinapoyl sucrose. ConclusionIt is recommended that the content limit for polygalaxanthone Ⅲ in YZ,YP and ZYZ be revised to not less than 0.07%, or the total content of polygalaxanthone Ⅲ, sibiricaxanthone B and polygalaxanthone Ⅺ be not less than 0.18%. The newly established triple quality control model of "holistic control via characteristic chromatograms, precise quantification of oligosaccharide esters, and efficient detection of xanthones by QAMS" provides a systematic and precise solution for quality evaluation of PR and similar Chinese herbal medicines.
2.Survival impact of radiotherapy for patients with de novo metastatic rectal cancer
Harvey Yu-Li SU ; Yun-Hsuan LIN ; Ko-Chao LEE ; Yueh-Ming LIN ; Chun-Chieh HUANG ; Eng-Yen HUANG ; Tai-Jan CHIU ; Shih-Yu HUANG ; Chia-Che WU ; Chang-Ting LIN ; Ming-Chun KUO ; Kai-Lung TSAI
Annals of Coloproctology 2026;42(1):94-102
Purpose:
Metastatic rectal cancer (mRC) is a highly lethal and complex disease that demands a multidisciplinary treatment approach. However, the clinical effectiveness of radiotherapy (RT) for de novo mRC remains controversial and uncertain.
Methods:
This retrospective cohort study examined medical records from Kaohsiung Chang Gung Memorial Hospital for patients with histologically confirmed de novo mRC diagnosed between January 2015 and December 2020. All patients received standard systemic therapy and radical surgery when feasible. The primary outcome, overall survival (OS), was assessed using the Kaplan-Meier method. Multivariable analysis was performed using a Cox regression model.
Results:
Among 271 patients included in the analysis, 117 received RT and 154 did not. The median OS was significantly longer in the RT group compared with the non-RT group (27.8 months vs. 21.9 months; P=0.046). Multivariate analysis identified several independent predictors of OS: age ≥65 years (hazard ratio [HR], 1.69; 95% confidence interval [CI], 1.26–2.27; P=0.001), primary tumor resection (HR, 2.62; 95% CI, 1.90–3.61; P<0.001), M1b or M1c disease (HR, 1.97; 95% CI, 1.44–2.69; P<0.001), and receipt of RT (HR, 1.41; 95% CI, 1.02–1.94; P=0.036).
Conclusion
RT significantly improves OS in patients with mRC, underscoring its role in treatment strategies. These findings support its inclusion in therapeutic protocols and highlight the need for larger, multicenter trials to confirm and extend these results.
3.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
4.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
5.Atomic Fluorescence Dispersion Detection Technique Based on Area Array Single Photon Counting Imaging Detector
Chen TAO ; Hong-Ji ZHANG ; Chun-Sheng LI ; Ling-Ping HE ; Zhen-Yu MA ; Bo CHEN ; Ran ZHANG
Chinese Journal of Analytical Chemistry 2025;53(2):187-194
The single photon counting imaging detector based on microchannel plate(MCP)has the characteristics of high sensitivity and low dark count rate,and has been applied to the optical remote sensing detection of weak ultraviolet spectral signals in space.In this work,by using planar array single photon counting imaging detector as the detector,flat-field concave grating as the splitter,and electrodeless discharge lamp(EDL)as the excitation light source,a dispersion detection system suitable for hydride generation-atomic fluorescence spectrometry(HG-AFS)was developed.The wavelength calibration of the system was carried out,and the negative high pressure and EDL stability time of the planar array single photon counting imaging detector were analyzed and optimized.The characteristic emission spectral lines of As and Bi elements excited in the wavelength range of 180-320 nm were analyzed,and the scattering interference in the wavelength range of 257.3-306.7 nm was discussed.The results showed that the AFS dispersion detection system based on the planar array single photon counting imaging detector could detect and analyze the HG-AFS fluorescence signal initially,and the influence of scattering interference on the detection results was effectively avoided.The system had the advantages including simple structure,no refrigeration and temperature control,no moving parts and simultaneous measurement of multi-band.
6.Changing antimicrobial resistance profiles of Burkholderia cepacia in hospitals across China:results from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Chunyue GE ; Yunjian HU ; Xiaoman AI ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Hui LI ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(5):557-562
Objective To examine the changing prevalence and antimicrobial resistance profiles of Burkholderia cepacia in 52 hospitals across China from 2015 to 2021.Methods A total of 9 261 strains of B.cepacia were collected from 52 hospitals between January 1,2015 and December 31,2021.Antimicrobial susceptibility of the strains was tested using Kirby-Bauer method or automated antimicrobial susceptibility testing systems according to a unified protocol.The results were interpreted according to the breakpoints released in the Clinical & Laboratory Standards Institute(CLSI)guidelines(2023 edition).Results A total of 9 261 strains of B.cepacia were isolated from all age groups,especially elderly patients.The proportion was 11.1%(1 032 strains)in children,significantly lower than the proportion in adults.About half(46.5%,4 310/9 261)of the strains were isolated from patients at least 60 years old and 42.3%(3 919/9 261)of the strains were isolated from young adults.Most isolates(71.1%)were isolated from sputum and respiratory secretions,followed by urine(10.7%)and blood samples(8.1%).B.cepacia isolates were highly susceptible to the five antimicrobial agents recommended in the CLSI M100 document(33rd edition,2023).B.cepacia isolates showed relatively higher resistance rates to meropenem and levofloxacin.However,the resistance rates to ceftazidime,trimethoprim-sulfamethoxazole,and minocycline remained below 8.1%.The percentage of B.cepacia strains resistant to levofloxacin was the highest compared to other antibiotics in any of the three age groups(from 12.4%in the patients<18 years old to 20.6%in the patients aged 60 years or older).Conclusions B.cepacia is one of the clinically important non-fermenting gram-negative bacteria.Accurate and timely reporting of antimicrobial susceptibility test results and ongoing antimicrobial resistance surveillance are helpful for rational prescription of antimicrobial agents and proper prevention and control of nosocomial infections.
7.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
8.Changing prevalence and antibiotic resistance profiles of carbapenem-resistant Enterobacterales in hospitals across China:data from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Wenxiang JI ; Tong JIANG ; Jilu SHEN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yuanhong XU ; Ying HUANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yingchun XU ; Xiaojiang ZHANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Hong ZHANG ; Chun WANG ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(4):445-454
Objective To summarize the changing prevalence of carbapenem resistance in Enterobacterales based on the data of CHINET Antimicrobial Resistance Surveillance Program from 2015 to 2021 for improving antimicrobial treatment in clinical practice.Methods Antimicrobial susceptibility testing was performed using a commercial automated susceptibility testing system according to the unified CHINET protocol.The results were interpreted according to the breakpoints of the Clinical & Laboratory Standards Institute(CLSI)M100 31st ed in 2021.Results Over the seven-year period(2015-2021),the overall prevalence of carbapenem-resistant Enterobacterales(CRE)was 9.43%(62 342/661 235).The prevalence of CRE strains in Klebsiella pneumoniae,Citrobacter freundii,and Enterobacter cloacae was 22.38%,9.73%,and 8.47%,respectively.The prevalence of CRE strains in Escherichia coli was 1.99%.A few CRE strains were also identified in Salmonella and Shigella.The CRE strains were mainly isolated from respiratory specimens(44.23±2.80)%,followed by blood(20.88±3.40)%and urine(18.40±3.45)%.Intensive care units(ICUs)were the major source of the CRE strains(27.43±5.20)%.CRE strains were resistant to all the β-lactam antibiotics tested and most non-β-lactam antimicrobial agents.The CRE strains were relatively susceptible to tigecycline and polymyxins with low resistance rates.Conclusions The prevalence of CRE strains was increasing from 2015 to 2021.CRE strains were highly resistant to most of the antibacterial drugs used in clinical practice.Clinicians should prescribe antimicrobial agents rationally.Hospitals should strengthen antibiotic stewardship in key clinical settings such as ICUs,and take effective infection control measures to curb CRE outbreak and epidemic in hospitals.
9.Changing distribution and antibiotic resistance profiles of the respiratory bacterial isolates in hospitals across China:data from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Ying FU ; Yunsong YU ; Jie LIN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE ; Wenhui HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(4):431-444
Objective To characterize the changing species distribution and antibiotic resistance profiles of respiratory isolates in hospitals participating in the CHINET Antimicrobial Resistance Surveillance Program from 2015 to 2021.Methods Commercial automated antimicrobial susceptibility testing systems and disk diffusion method were used to test the susceptibility of respiratory bacterial isolates to antimicrobial agents following the standardized technical protocol established by the CHINET program.Results A total of 589 746 respiratory isolates were collected from 2015 to 2021.Overall,82.6%of the isolates were Gram-negative bacteria and 17.4%were Gram-positive bacteria.The bacterial isolates from outpatients and inpatients accounted for(6.0±0.9)%and(94.0±0.1)%,respectively.The top microorganisms were Klebsiella spp.,Acinetobacter spp.,Pseudomonas aeruginosa,Staphylococcus aureus,Haemophilus spp.,Stenotrophomonas maltophilia,Escherichia coli,and Streptococcus pneumoniae.Each microorganism was isolated from significantly more males than from females(P<0.05).The overall prevalence of methicillin-resistant S.aureus(MRSA)was 39.9%.The prevalence of penicillin-resistant S.pneumoniae was 1.4%.The prevalence of extended-spectrum β-lactamase(ESBL)-producing E.coli and K.pneumoniae was 67.8%and 41.3%,respectively.The overall prevalence of carbapenem-resistant E.coli,K.pneumoniae,Enterobacter cloacae,Pseudomonas aeruginosa,and Acinetobacter baumannii was 3.7%,20.8%,9.4%,29.8%,and 73.3%,respectively.The prevalence of β-lactamase was 96.1%in Moraxella catarrhalis and 60.0%in Haemophilus influenzae.The H.influenzae isolates from children(<18 years)showed significantly higher resistance rates to β-lactam antibiotics than the isolates from adults(P<0.05).Conclusions Gram-negative bacteria are still predominant in respiratory isolates associated with serious antibiotic resistance.Antimicrobial resistance surveillance should be strengthened in clinical practice to support accurate etiological diagnosis and appropriate antimicrobial therapy based on antimicrobial susceptibility testing results.
10.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]

Result Analysis
Print
Save
E-mail