1.The safety and efficacy of boron neutron capture therapy (BNCT) in the treatment of recurrent malignant tumors
Junqiang HONG ; Xiaoyi LIN ; Youqun LAI ; Ye CAO ; Xiangquan KONG ; Yuanhao LIU ; Shuiying LUO ; Zhicheng XIONG ; Mei GONG ; Yalai LIN ; Qiaoyun CHEN ; Mingang YING ; Li HUO ; Xiaohua ZHU ; Xiaoping SUN ; Yiqiao DENG ; Diyun SHU ; Haige ZHANG ; Cheng HUANG ; Jianji PAN
Chinese Journal of Radiation Oncology 2025;34(10):985-992
Objective:To evaluate the safety and efficacy of accelerator-based boron neutron capture therapy (AB-BNCT) in the treatment of recurrent and refractory malignant tumors.Methods:The data of 14 patients admitted to Xiamen Humanity Hospital from September 2022 to April 2023 were prospectively collected, including 7 patients with primary brain malignancies and 7 patients with locally recurrent inoperable head and neck malignancies. All patients received intravenous infusion of boron drug (NBB-001, p-dihydroxyborylphe nylalanine, a patented freeze-dried formulation) at a total nominal dosage of 500 mg/kg (11 patients) or 750 mg/kg (3 patients), and were irradiated with neutrons (operating with NeuPex system). Adverse events after treatment were recorded and assessed. The primary efficacy endpoint was the 90 d objective response rate (ORR), while the secondary endpoints included progression-free survival (PFS) and complete response rate (CRR). Data were compiled and analyzed by SAS 9.4 software. The rate and 95% CI were calculated using Clopper-Pearson method. Results:The median dose delivered to 80% of the target volume (D 80%) was 16.80 GyE (range: 8.93-23.79 GyE). The most common adverse reactions were hyperamylasemia, alopecia, and hyperprolactinemia. Five patients experienced 8 cases of grade 3 or above adverse events, including 1 case of grade 4 acute kidney injury and 7 cases of grade 3 adverse events. All adverse events were recovered after observation or treatment. At 90 d after treatment, the ORR of all patients was 9/14 (64%, 95% CI: 35%-87%), disease control rate (DCR) was 10/14 (71%, 95% CI: 42%-92%), CRR was 2/14 (14%, 95% CI: 2%-42%); and the best overall response during the entire course included an ORR of 10/14 (71% ,95% CI: 42%-92%), DCR of 13/14 (93%, 95% CI: 66%-100%), and CRR of 3/14 (21% ,95% CI: 5%-51%). The 1-year survival rate for head and neck malignancies was 71.4%, and the 2-year survival rate was 42.8%. The 1-year survival rate for recurrent brain malignancies was 42.8%. Conclusion:AB-BNCT demonstrates favorable safety and promising efficacy in treating primary brain malignancies and recurrent/refractory head and neck malignancies, representing a potential therapeutic option.
2.In vivo measurement of radionuclides and radiation levels around patients after BNCT treatment
Ye CAO ; Diyun SHU ; Yufeng XIAO ; Youqun LAI ; Jinsheng CHENG ; Senxing ZHENG ; Jilong YUAN ; Xiaohua MIU ; Jianji PAN ; Yuanhao LIU
Chinese Journal of Radiological Medicine and Protection 2025;45(7):668-673
Objective:To explore the in vitro radiation levels and in vivo neutron activation after patients receiving boron neutron capture therapy (BNCT). Methods:Totally 29 BNCT treatments were performed for 21 patients with head and neck and brain cancer using the NeuPex accelerator-based boron neutron capture therapy (AB-BNCT) system in Xiamen Humanity Hospital from October, 2022 to April, 2024. The ambient dose equivalent rate around the patients was measured with an X/gamma dose rate survey meter. The gamma radiation dose rates were measured at 0, 0.5, 1.0, and 2.0 m from the irradiation position, at 0, 0.5, 1.0, and 2.0 m from the opposite side of the irradiation position, and at the navel and the affected knee, respectively. Meanwhile, a portable high-purity germanium gamma spectrometer was used to measure the spectrum of activated nuclides in the bodies of patients who had underwent the treatment, and the types of radionuclides generated by neutron activation during each BNCT treatment were analyzed.Results:The radionuclides 24Na, 38Cl, and 49Ca were mainly produced in the bodies of patients treated with BNCT. 20 minutes after BNCT treatment, the ambient dose equivalent rate at a distance of 1.0 m from the irradiation position was lower than 2.5 μSv/h. Conclusions:The dose delivered to the staff and family members by the patients undergoing BNCT is relatively low, and the resulting radiation risk is low. According to the ALARA principle, it is recommended that certain control actions be taken for patients having received BNCT treatment to minimize the exposure doses of both patients and staff as much as possible.
3.In vivo measurement of radionuclides and radiation levels around patients after BNCT treatment
Ye CAO ; Diyun SHU ; Yufeng XIAO ; Youqun LAI ; Jinsheng CHENG ; Senxing ZHENG ; Jilong YUAN ; Xiaohua MIU ; Jianji PAN ; Yuanhao LIU
Chinese Journal of Radiological Medicine and Protection 2025;45(7):668-673
Objective:To explore the in vitro radiation levels and in vivo neutron activation after patients receiving boron neutron capture therapy (BNCT). Methods:Totally 29 BNCT treatments were performed for 21 patients with head and neck and brain cancer using the NeuPex accelerator-based boron neutron capture therapy (AB-BNCT) system in Xiamen Humanity Hospital from October, 2022 to April, 2024. The ambient dose equivalent rate around the patients was measured with an X/gamma dose rate survey meter. The gamma radiation dose rates were measured at 0, 0.5, 1.0, and 2.0 m from the irradiation position, at 0, 0.5, 1.0, and 2.0 m from the opposite side of the irradiation position, and at the navel and the affected knee, respectively. Meanwhile, a portable high-purity germanium gamma spectrometer was used to measure the spectrum of activated nuclides in the bodies of patients who had underwent the treatment, and the types of radionuclides generated by neutron activation during each BNCT treatment were analyzed.Results:The radionuclides 24Na, 38Cl, and 49Ca were mainly produced in the bodies of patients treated with BNCT. 20 minutes after BNCT treatment, the ambient dose equivalent rate at a distance of 1.0 m from the irradiation position was lower than 2.5 μSv/h. Conclusions:The dose delivered to the staff and family members by the patients undergoing BNCT is relatively low, and the resulting radiation risk is low. According to the ALARA principle, it is recommended that certain control actions be taken for patients having received BNCT treatment to minimize the exposure doses of both patients and staff as much as possible.
4.The safety and efficacy of boron neutron capture therapy (BNCT) in the treatment of recurrent malignant tumors
Junqiang HONG ; Xiaoyi LIN ; Youqun LAI ; Ye CAO ; Xiangquan KONG ; Yuanhao LIU ; Shuiying LUO ; Zhicheng XIONG ; Mei GONG ; Yalai LIN ; Qiaoyun CHEN ; Mingang YING ; Li HUO ; Xiaohua ZHU ; Xiaoping SUN ; Yiqiao DENG ; Diyun SHU ; Haige ZHANG ; Cheng HUANG ; Jianji PAN
Chinese Journal of Radiation Oncology 2025;34(10):985-992
Objective:To evaluate the safety and efficacy of accelerator-based boron neutron capture therapy (AB-BNCT) in the treatment of recurrent and refractory malignant tumors.Methods:The data of 14 patients admitted to Xiamen Humanity Hospital from September 2022 to April 2023 were prospectively collected, including 7 patients with primary brain malignancies and 7 patients with locally recurrent inoperable head and neck malignancies. All patients received intravenous infusion of boron drug (NBB-001, p-dihydroxyborylphe nylalanine, a patented freeze-dried formulation) at a total nominal dosage of 500 mg/kg (11 patients) or 750 mg/kg (3 patients), and were irradiated with neutrons (operating with NeuPex system). Adverse events after treatment were recorded and assessed. The primary efficacy endpoint was the 90 d objective response rate (ORR), while the secondary endpoints included progression-free survival (PFS) and complete response rate (CRR). Data were compiled and analyzed by SAS 9.4 software. The rate and 95% CI were calculated using Clopper-Pearson method. Results:The median dose delivered to 80% of the target volume (D 80%) was 16.80 GyE (range: 8.93-23.79 GyE). The most common adverse reactions were hyperamylasemia, alopecia, and hyperprolactinemia. Five patients experienced 8 cases of grade 3 or above adverse events, including 1 case of grade 4 acute kidney injury and 7 cases of grade 3 adverse events. All adverse events were recovered after observation or treatment. At 90 d after treatment, the ORR of all patients was 9/14 (64%, 95% CI: 35%-87%), disease control rate (DCR) was 10/14 (71%, 95% CI: 42%-92%), CRR was 2/14 (14%, 95% CI: 2%-42%); and the best overall response during the entire course included an ORR of 10/14 (71% ,95% CI: 42%-92%), DCR of 13/14 (93%, 95% CI: 66%-100%), and CRR of 3/14 (21% ,95% CI: 5%-51%). The 1-year survival rate for head and neck malignancies was 71.4%, and the 2-year survival rate was 42.8%. The 1-year survival rate for recurrent brain malignancies was 42.8%. Conclusion:AB-BNCT demonstrates favorable safety and promising efficacy in treating primary brain malignancies and recurrent/refractory head and neck malignancies, representing a potential therapeutic option.
5.Left ventricle partial and global diastolic function evaluated in patients with silent myocardial ischemia by Doppler combined with dobutamine stress echocardiography
Xianghong CHEN ; Xiaoling LAI ; Youqun YIN ; Yuhuan XIE ; Ziai LIU
Chinese Journal of Primary Medicine and Pharmacy 2008;15(6):913-915
ObjectiveTo evaluate left ventricle partial and global diastolic function in patients with silentmyocardial ischemia (SMI) by Doppler tissue imaging (DTI) combined with dobutamine stress echocardiography(DSE).Methods30 cases of silent myocardial ischemia(SMI) and 30 cases of normal control underwent dobu-tamine stressechocardiography(DSE). DTI was acquired at baseline and stress, and waveforms in mitral valve clos- ing, and the base and mid segments of left ventricle were used to measure diastolic early velocity(Ve), diastolic latelyvelocity(Va) ,and E deceleration time(Te). ResultsⅤ in control group increased accompanied with the increasingdose of dobutamine, Ve/Va decreased a little but not significantly. Ⅴ in the group with silent myocardial ischemia(SMI) increased at 10μg·kg-1·min-1 ,but decreased at 40μg·kg-1·min-1 compared with 10μg·kg-1·min-1 ,T inboth control and DSE group decreased at 40μg/kg accompanied with 10μg·kg-1·min-1, T in both control and DSEgroup decreased accompanied with the increasing dose of dobutamine, and there were significant differences betweenthe groups(P < 0.05). ConclusionDTI-DSE could quantificadvely detect the partial and global diastolic function ofleft ventricle.

Result Analysis
Print
Save
E-mail