2.Coexisting Macular Hole and Uveal Melanoma: A Case Series and Literature Review
Yeji KIM ; So Hyun YU ; Yong Joon KIM ; Eun Young CHOI ; Sung Chul LEE ; Christopher Seungkyu LEE
Korean Journal of Ophthalmology 2025;39(2):170-180
Purpose:
To report five cases of macular hole (MH) coexisting with uveal melanoma (UM) and review the literature.
Methods:
Seventeen patients (5 new and 12 from previous reports) with coexisting MH and UM were reviewed. The patients were divided into two groups based on whether the MH was diagnosed before or after tumor treatment. The clinical features, pathogenesis, management options, and clinical outcomes were reviewed.
Results:
Of 505 patients with UM in our institution, 5 (1.0%) had a concurrent MH in the ipsilateral eye. The 17 patients reviewed had a mean age of 63.9 years at the time of MH diagnosis. Of 16 patients with available data on sex, 11 (64.7%) were female. There were no major differences in the demographic or clinical data of the groups. Of the 15 known tumor locations, 6 (35.3%) were juxtapapillary or macular. In patients who developed MH after UM treatment, the durations from tumor treatment (radiotherapy or transpupillary thermotherapy) to MH diagnosis were 3 to 56 months (median, 8.5 months). MH surgery was performed in nine eyes, and hole closure was achieved in seven eyes with postoperative data. The mean visual acuity showed a tendency of improvement after surgery. No intraocular or extraocular tumor dissemination associated with surgery was observed.
Conclusions
MH is observed in approximately 1% of patients with UM, either before or after tumor treatment. Of patients with coexisting MH and UM, MH surgery appears to be safe and effective in those with stable tumors and visual potential.
3.Comparison of Toric Intraocular Lens Axis Accuracy between Optical Biometry and Dual Scheimpflug Topography
Seonghwan KIM ; Yengwoo SON ; Joon Young HYON
Korean Journal of Ophthalmology 2025;39(1):64-70
Purpose:
To evaluate the accuracy of toric intraocular lens (IOL) axis prediction between two preoperative measurement devices: the optical biometry (IOLMaster 500 or IOLMaster 700) and the dual Scheimpflug topography (Galilei G4)
Methods:
Medical records of 64 eyes from 44 patients who underwent phacoemulsification and posterior chamber toric IOL (Zeiss AT TORBI 709M) implantation between July 2017 and January 2022 were reviewed. All patients underwent preoperative evaluation by optical biometry (IOLMaster 500 or IOLMaster 700) and Galilei G4. The gold-standard axis that minimizes astigmatism was calculated by the online Toric Results Analyzer postoperatively and compared to the preoperative toric IOL axis calculated by the Z CALC Online IOL Calculator using parameters from either IOLMaster or Galilei G4. The axis error (AE) and the absolute AE (AAE) between the gold-standard axis and the preoperative calculated axis were analyzed to assess the accuracy of each device.
Results:
The mean flat keratometry and steep keratometry were 42.99 diopters (D) and 45.61 D, respectively, in IOLMaster, and 43.04 D and 45.51 D, respectively, in Galilei G4, which did not show any significant difference. The mean keratometric astigmatism was 2.62 D in IOLMaster and 2.46 D in Galilei G4, which also did not show any statistical difference. The keratometric astigmatism axis did not show any significant difference between IOLMaster and Galilei G4. The mean AE and AAE were 0.19° and 6.84°, respectively, by IOLMaster, and –0.80° and 7.98°, respectively, by Galilei G4. The AE and AAE by IOLMaster did not show any significant difference compared to those of Galilei G4 (p = 0.583, and p = 0.346, respectively).
Conclusions
This study suggests that the Galilei G4 demonstrated a similar level of accuracy to the IOLMaster in predicting the toric IOL axis, based on the gold-standard axis provided by the Toric Results Analyzer.
4.Reinjection in Patients with Intraocular Inflammation Development after Intravitreal Brolucizumab Injection
Myung Ae KIM ; Soon Il CHOI ; Jong Min KIM ; Hyun Sub OH ; Yong Sung YOU ; Won Ki LEE ; Soon Hyun KIM ; Oh Woong KWON ; Ju Young KIM
Korean Journal of Ophthalmology 2025;39(3):213-221
Purpose:
To investigate the outcomes of brolucizumab reinjection after intraocular inflammation (IOI) development.
Methods:
This retrospective study analyzed patients with brolucizumab injections from April 2021 to January 2024. Patients who developed IOI after brolucizumab were included and categorized into subgroups depending on reinjection, discontinuation, and further IOI development.
Results:
A total of 472 eyes of 432 patients received brolucizumab injections. Thirty-eight cases developed IOI at least once, and 25 continued brolucizumab. Sixteen cases had no more IOI events, and nine experienced a second or more IOI events. Among the nine cases, three maintained brolucizumab injections despite IOI recurrence. The incidence of IOI was 8.1% based on the number of eyes (38 of 472 eyes) and 2.0% based on the number of brolucizumab injections (50 of 2,468 injections). The incidence of occlusive retinal vasculitis was 0.2% (1 of 472 eyes). The recurrence rate was 23.7% (9 of 38 eyes). The average number of injections between the first brolucizumab injection and the injection date on which IOI first developed was 2.15 times in the no-reinjection group, 3.44 times in the no-IOI-recurrence group, and 2.0 times in the second-IOI-episode group. Time to IOI occurrence in cases with first IOI episode was 18.60 ± 16.73 days, with 15 cases developing IOI within 1 week.
Conclusions
This study elucidates the real-world incidence of brolucizumab associated IOIs, with a description of information related to reinjections after the IOI episodes. A comprehensive understanding of brolucizumab reinjection is essential for its optimal utilization.
5.A Case of Invasive Rhino-Orbito-Cerebral Mucormycosis After Acupuncture Therapy for Bell’s Palsy
Younghac KIM ; Han-Sin JEONG ; Young Sang CHO ; Nayeon CHOI
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(1):36-39
Rhino-orbito-cerebral mucormycosis (ROCM) is a rare fungal infection that may be fatal in immunocompromised patients. Acupuncture is commonly used in Eastern Asia in addition to steroid medication for the treatment of Bell’s palsy. For such patients with comorbid medical conditions, potential risks might arise after the acupuncture procedure; however, ROCM following acupuncture therapy has not been reported to date. Here we present a rare case of invasive mucormycosis that began from the facial skin after acupuncture procedure. In this case, the patient was suspected of ROCM infection and emergently treated with surgical debridement and antifungal therapy. Despite early surgical debridement and medical treatment, the patient died due to brain infarction and invasion of mucormycosis into the internal carotid artery and cavernous sinus. Although acupuncture therapy is considered relatively safe in general, care should be taken when performing acupuncture in patients with underlying diseases that cause immunosuppression.
6.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
7.Changing Gadolinium-Based Contrast Agents to Prevent Recurrent Acute Adverse Drug Reactions: 6-Year Cohort Study Using Propensity Score Matching
Min Woo HAN ; Chong Hyun SUH ; Pyeong Hwa KIM ; Seonok KIM ; Ah Young KIM ; Kyung-Hyun DO ; Jeong Hyun LEE ; Dong-Il GWON ; Ah Young JUNG ; Choong Wook LEE
Korean Journal of Radiology 2025;26(2):204-204
8.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
9.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
10.Implementation of a Learning Management System at Yonsei University College of Medicine
Hanna JUNG ; Hangil KIM ; Hyung-Jin RHEE ; Sang Ah LEE ; Shinki AN ; Young Han LEE
Korean Medical Education Review 2025;27(1):40-51
This paper details the development and implementation of Yonsei Medical E-Learning System 3.0 (YES 3.0), a new learning management system (LMS) for Yonsei University College of Medicine. Driven by the need to adapt to a rapidly changing medical education landscape, YES 3.0 addresses the previous system’s limitations and incorporates advanced features designed to improve learning experiences and educational outcomes. The development process involved extensive collaboration among faculty, students, staff, and the system developer, ensuring the system's alignment with the unique needs of the medical education environment. YES 3.0 features real-time monitoring of learning progress, comprehensive evaluation and grade management, personalized learning path recommendations, effective learner history management, and interview/guidance management functionalities. The system also supports the newly revised CDP2023 (Curriculum Development Project 2023) curriculum, with integrated learning across all courses and a strengthened scholarly advanced course. By automating and streamlining various educational processes, YES 3.0 enables maximized learning efficiency, promotes learner-centered education, and supports the cultivation of future medical professionals equipped to navigate the evolving healthcare environment. Implementing the system is expected to have positive impacts on both educational and economic aspects, contributing to the advancement of medical education at Yonsei University College of Medicine. This study also aims to offer insights and expected outcomes that can serve as a reference for other medical schools in adopting and operating LMS, ultimately providing useful information to educators considering establishing a digital learning environment.

Result Analysis
Print
Save
E-mail