2.Comparative Analysis of Minimally Invasive and Open Proximal Chevron-Akin Osteotomies in Moderate-to-Severe Hallux Valgus Deformity
Jun Young CHOI ; Sun Oh JUNG ; Jin Soo SUH
Clinics in Orthopedic Surgery 2025;17(3):514-522
Background:
Studies comparing the minimally invasive proximal chevron and Akin osteotomies (MIPCA) technique with conventional techniques, such as the open proximal chevron metatarsal osteotomy with the Akin procedure (open PCMO-Akin procedure), are limited. This study aimed to compare and evaluate operative MIPCA and open PCMO-Akin procedure outcomes in the surgical correction of moderate-to-severe hallux valgus deformities.
Methods:
We conducted a retrospective comparison of clinical and radiographic outcomes between the MIPCA and open PCMOAkin procedure in patients with a hallux valgus deformity, defined as a preoperative hallux valgus angle (HVA) of ≥ 30° and/or a first to second intermetatarsal angle of ≥ 13°. The postoperative complication rate was monitored in both groups for a minimum of 12 months. An unsatisfactory correction was defined as an HVA > 15° at final follow-up.
Results:
We assigned 58 and 99 patients to the MIPCA or open PCMO-Akin procedure group, respectively. At final follow-up, no significant differences were observed between the groups in terms of clinical and radiographic parameters (p > 0.05), with the exception of the distal metatarsal articular angle (DMAA) (p = 0.012). No statistically significant postoperative changes in the DMAA were observed in the MIPCA group (p = 0.875). Five patients (5.1%) experienced postoperative hallux varus in the open PCMO-Akin procedure group, whereas no such cases were observed in the MIPCA group. No statistically significant difference in the rate of unsatisfactory correction was observed between the groups at the final follow-up (MIPCA group, 15.5%; open PCMO-Akin procedure group, 10.1%; p = 0.315).
Conclusions
The MIPCA technique is a viable alternative to the open PCMO-Akin procedure for correcting moderate-to-severe hallux valgus deformities. Given the potential lack of postoperative changes in the DMAA following the MIPCA technique, careful consideration is advised when applying this technique to patients with a large DMAA.
3.Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series
Jae-Won SHIN ; Han-Bin JIN ; Yung PARK ; Joong-Won HA ; Hak-Sun KIM ; Kyung-Soo SUK ; Sung-Hwan MOON ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; In-Uk KIM
Clinics in Orthopedic Surgery 2025;17(3):417-426
Background:
To identify the optimal surgical technique for single-level anterior cervical discectomy and fusion (ACDF), this study compared surgical outcomes and incidence of adjacent segment degeneration (ASD) in patients undergoing single-level ACDF using cage alone single-level fusion and plate fixation techniques.
Methods:
This single-center retrospective study (2003–2018) included patients who underwent single-level ACDF with either plate fixation (PLATE) or cage (CAGE) alone. The radiologic and clinical outcomes between the 2 surgical groups were compared over a 4-year follow-up period. Outcomes of interest included parameters related to range of motion, sagittal alignment, as well as fusion, subsidence, and ASD rates. Clinical outcomes were evaluated using the Neck Disability Index (NDI) and visual analog scale (VAS) for pain. Dysphagia and hoarseness rates were estimated based on medical records.
Results:
Forty-seven patients were included (n=17 in CAGE group). In the CAGE group, 94.1% of the patients had Bridwell grade 1 or 2, compared to 83.3% in the PLATE group (p = 0.396). Subsidence occurred in 12.5% and 3.6% of the CAGE and PLATE cases, respectively (p = 0.543). Segmental kyphosis progressed in the CAGE group compared to the PLATE group at 12, 24, and 48 months (p < 0.001). Radiographic ASD was observed in 41.2% and 30.0% of patients in the CAGE and PLATE groups, respectively, with a higher incidence in the upper segments for both groups. Preoperative NDI scores were similar between the groups; however, postoperatively, the CAGE group had significantly lower NDI scores (3.50 ± 2.74 vs. 8.00 ± 5.81) at 4 years (p = 0.020). Neck pain VAS scores also showed significant improvement in the CAGE group (2.33 ± 2.94) compared with that in the PLATE group (3.07 ± 2.31) at 4 years (p = 0.045). Both groups showed comparable arm pain VAS scores at 2 and 4 years postoperatively. Postoperative dysphagia occurred in 1 patient in the PLATE group, resolving almost completely by 1 year.
Conclusions
Single-level ACDF using a cage alone technique demonstrated favorable radiologic and clinical outcomes overall compared to plate-augmented ACDF. However, plate augmentation is recommended for patients with severe cervical kyphosis or those at high risk of subsidence.
4.Effects of Pressure Hemostasis Band Application on Bleeding, Pain, and Discomfort after Bone Marrow Examination
Jin Hee JUNG ; Bo-Eun KIM ; Ji Sook JU ; Mi RYU ; So Young CHOE ; Jong Hee CHOI ; Soo-Mee BANG ; Jeong-Ok LEE ; Ji Yun LEE ; Sang-A KIM
Asian Oncology Nursing 2025;25(1):17-27
Purpose:
The purpose of this study was to develop an approach to alleviate the discomfort caused by sandbag compression after a bone marrow examination. This research examined the effects of applying a pressure hemostasis band on bleeding, pain, and discomfort at the bone marrow examination site.
Methods:
This study was conducted with a nonequivalent control group non-synchronized design. For 74 patients under evaluation who underwent bone marrow examination, sandbag compression was applied to the examination site in the control group (n=37), and a pressure hemostasis band was applied to the intervention group (n=37). In both groups, absolute bed rest was performed for two hours, and bleeding, pain, and discomfort at the examination site were measured.
Results:
After two hours of the bone marrow examination, there was no difference in bleeding on the gauze between the two groups (F=0.59, p=.444). Bleeding occurred in three patients in the intervention group and six in the control group (χ 2 =1.14, p=.479), with no cases of hematoma detected in either group. One hour post-examination, the control group experienced significantly higher pain (F=5.45, p=.022) and discomfort (F=5.68, p=.020) than the intervention group. However, pain and discomfort levels were similar between groups after two hours.
Conclusion
Compared to the sandbag compression group, the band application group showed no difference in bleeding and experienced less pain and discomfort at the examination site. This confirms that the pressure hemostasis band is a suitable alternative to sandbag compression in post-examination care.
5.Biportal endoscopic non-facetectomy foraminal decompression and discectomy (ligamentum flavum turn-down technique)
Dae-Young LEE ; Han-Bin JIN ; Hee Soo KIM ; Jun-Bum LEE ; Si-Young PARK ; Seung-Hwan KOOK
Asian Spine Journal 2025;19(2):259-266
This study introduces a novel biportal endoscopic foraminal decompression technique that minimizes bone removal while ensuring safe and effective nerve root decompression. Leveraging the accessory process as a key surgical landmark, this technique enables precise navigation and controlled turn-down of the ligamentum flavum (LF). A key advantage of this technique is its reduced requirement for bone resection, differing from traditional microscopic or uniportal endoscopic surgeries that often necessitate resection of the lateral isthmus or superior articular process. This technique is particularly beneficial for foraminal and extraforaminal herniated nucleus pulposus cases, where bony decompression needs are relatively lower compared to foraminal stenosis. Using the accessory process as a landmark also enhances surgical precision and reduces the risk of nerve root injury, providing a valuable advantage for less experienced surgeons. Despite these advantages, challenges exist, particularly at the L5–S1 level, where the less prominent accessory process and limited workspace due to anatomical constraints can pose difficulties. In cases of severe bony compression, additional bone removal may be necessary to achieve adequate decompression. In conclusion, the Non-facetectomy LF turn-down technique (non-facetectomy foraminal decompression) offers a safe and effective minimally invasive alternative for treating various foraminal pathologies.
6.Part 1. Current Status of Hearing Loss Patients in Korea Using National Data: National Health Insurance Service- Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(1):7-18
Background and Objectives:
Hearing loss significantly affects communication, psychosocial well-being, and quality of life. This study analyzes the National Health Insurance Service database to assess the trends and characteristics of hearing loss in South Korea from 2010 to 2020.Subjects and Method The database encompasses 97% of the Korean population, providing comprehensive data on medical history, prescriptions, and health examinations. The analysis used the World Health Organization’s ICD-10 definitions to categorize hearing loss types and examine their prevalence and incidence across various demographics over 11 years.
Results:
There was an overall annual increase of 4.62% in diagnosed cases of hearing loss, with the most significant rise among the elderly. The rate of increase accelerated from 3.32% between 2010 and 2014 to 6.49% between 2014 and 2020, corresponding with the improved hearing aid access facilitated by policy changes. Women showed a slightly higher increase than men. The data also indicated a consistent rise in abnormal hearing test results during health examinations, especially in older adults.
Conclusion
The study highlights an increasing trend in hearing loss diagnoses, driven by an aging population and enhanced detection facilitated by policy changes. These findings emphasize the need for continuous monitoring and targeted health policies to manage hearing loss effectively, offering valuable insights for global health management and policy development.
7.Part 2. Current Status of Hearing Disability and Hearing Rehabilitation Devices in Korea Using National Data: NHIS-Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):94-104
Background and Objectives:
This study aims to analyze trends in hearing disability and the use of hearing rehabilitation devices (hearing aids and cochlear implants) in South Korea over the past 11 years (2010-2020) using data from the National Health Insurance Service (NHIS).Subjects and Method Data were extracted from the NHIS database, covering approximately 97% of the South Korean population. Patients diagnosed with hearing loss were classified using ICD-10 codes. The data were analyzed to determine trends in hearing disability, hearing aid prescriptions, and cochlear implant usage by age, gender, and types and causes of hearing loss.
Results:
The number of hearing disability patients increased from 170900 in 2010 to 362738 in 2020, with an annual growth rate of 7.95%. The highest increase was observed in the ≥60 age group, with an annual growth rate of 11.04%. Hearing aid prescriptions rose from 4966 in 2010 to 11974 in 2020, showing a 10.45% annual increase. Females showed a higher growth rate in both hearing disability and hearing aid prescriptions compared to males. Cochlear implant prescriptions also increased, particularly among older adults.
Conclusion
The study highlights a significant rise in hearing disability and the use of hearing aids and cochlear implants in South Korea, especially among the elderly. The findings underscore the importance of early diagnosis and intervention for hearing loss and the need for policy improvements to enhance accessibility and affordability of hearing rehabilitation services. Additional strategies are needed to ensure appropriate hearing rehabilitation for those not yet receiving adequate care.
8.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
9.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
10.Permanent Congenital Hypothyroidism in Very Low Birth Weight Infants: A Single Center’s Experience
Joo Hyung ROH ; Tae-Gyeong KIM ; Keon Hee SEOL ; Chae Young KIM ; Soo Hyun KIM ; Ji Yoon JEONG ; Ja Hye KIM ; Euiseok JUNG ; Jin-Ho CHOI ; Byong Sop LEE
Neonatal Medicine 2025;32(1):30-38
Purpose:
Congenital hypothyroidism (CH) is a major preventable cause of intellectual disability, particularly in very low birth weight (VLBW) infants, who are at increased risk due to hypothalamic-pituitary-thyroid axis immaturity. Early differentiation between transient CH (TCH) and permanent CH (PCH) is crucial to optimize L-thyroxine (LT4) treatment duration. This study aimed to determine the incidence of PCH among Korean VLBW infants and to identify clinical factors that may aid in distinguishing TCH from PCH.
Methods:
This retrospective cohort study included VLBW infants diagnosed with CH and treated with LT4 at a single tertiary neonatal intensive care unit between 2011 and 2020. Infants requiring LT4 beyond 3 years were classified as PCH, while those who discontinued earlier were considered TCH. Clinical characteristics, neonatal morbidities, and thyroid-related parameters were compared between the groups.
Results:
Among 1,292 VLBW infants, 122 (9.4%) were diagnosed with CH. After excluding deaths and those lost to follow-up, 73 infants were included in the final analysis (TCH, n=50; PCH, n=23). The PCH group had a significantly higher mean gestational age and greater LT4 requirements at both 12 and 36 months of age. Major anomalies were more frequently observed in PCH infants, including congenital heart defects. In multivariate analysis, higher gestational age, the presence of major anomalies, screening thyroid-stimulating hormone (TSH) >10 μIU/mL, and higher LT4 dose at 36 months were significantly associated with PCH.
Conclusion
The incidence of PCH in Korean VLBW infants was relatively higher than that reported in previous studies studies. Screening TSH level and LT4 dose requirements may support individualized follow-up and help distinguish PCH from TCH.

Result Analysis
Print
Save
E-mail