1.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
2.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
3.A New Agenda for Optimizing Roles and Infrastructure in a Mental Health Service Model for South Korea
Eunsoo KIM ; Hyeon-Ah LEE ; Yu-Ri LEE ; In Suk LEE ; Kyoung-Sae NA ; Seung-Hee AHN ; Chul-Hyun CHO ; Hwoyeon SEO ; Soo Bong JUNG ; Sung Joon CHO ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):26-39
Objective:
As the demand for community mental health services continues to grow, the need for well-equipped and organized services has become apparent. This study aimed to optimize the roles and infrastructure of mental health services, by establishing, among other initiatives, standardized operating models.
Methods:
The study was conducted in multiple phases from May 12, 2021, to December 29, 2021. Stakeholders within South Korea and metropolitan mental health welfare centers were targeted, but addiction management support centers, including officials, patients, and their families, were integrated as well. A literature review and survey, focus group interviews, a Delphi survey, and expert consultation contributed to comprehensive revisions and improvements of the mental health service model.
Results:
The proposed model for community mental health welfare centers emphasizes the expansion of personnel and infrastructure, with a focus on severe mental illnesses and suicide prevention. The model for metropolitan mental health welfare centers delineates essential tasks in areas such as project planning and establishment, community research, and education about severe mental illnesses. The establishment of a 24-hour emergency intervention center was a crucial feature. In the integrated addiction support center model, the need to promote addiction management is defined as an essential task and the establishment of national governance for addiction policies is recommended.
Conclusion
This study proposed standard operating models for three types of mental health service centers. To meet the increasing need for community care, robust mental health service delivery systems are of primary importance.
4.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
5.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
6.A New Agenda for Optimizing Roles and Infrastructure in a Mental Health Service Model for South Korea
Eunsoo KIM ; Hyeon-Ah LEE ; Yu-Ri LEE ; In Suk LEE ; Kyoung-Sae NA ; Seung-Hee AHN ; Chul-Hyun CHO ; Hwoyeon SEO ; Soo Bong JUNG ; Sung Joon CHO ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):26-39
Objective:
As the demand for community mental health services continues to grow, the need for well-equipped and organized services has become apparent. This study aimed to optimize the roles and infrastructure of mental health services, by establishing, among other initiatives, standardized operating models.
Methods:
The study was conducted in multiple phases from May 12, 2021, to December 29, 2021. Stakeholders within South Korea and metropolitan mental health welfare centers were targeted, but addiction management support centers, including officials, patients, and their families, were integrated as well. A literature review and survey, focus group interviews, a Delphi survey, and expert consultation contributed to comprehensive revisions and improvements of the mental health service model.
Results:
The proposed model for community mental health welfare centers emphasizes the expansion of personnel and infrastructure, with a focus on severe mental illnesses and suicide prevention. The model for metropolitan mental health welfare centers delineates essential tasks in areas such as project planning and establishment, community research, and education about severe mental illnesses. The establishment of a 24-hour emergency intervention center was a crucial feature. In the integrated addiction support center model, the need to promote addiction management is defined as an essential task and the establishment of national governance for addiction policies is recommended.
Conclusion
This study proposed standard operating models for three types of mental health service centers. To meet the increasing need for community care, robust mental health service delivery systems are of primary importance.
7.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
8.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
9.A New Agenda for Optimizing Roles and Infrastructure in a Mental Health Service Model for South Korea
Eunsoo KIM ; Hyeon-Ah LEE ; Yu-Ri LEE ; In Suk LEE ; Kyoung-Sae NA ; Seung-Hee AHN ; Chul-Hyun CHO ; Hwoyeon SEO ; Soo Bong JUNG ; Sung Joon CHO ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):26-39
Objective:
As the demand for community mental health services continues to grow, the need for well-equipped and organized services has become apparent. This study aimed to optimize the roles and infrastructure of mental health services, by establishing, among other initiatives, standardized operating models.
Methods:
The study was conducted in multiple phases from May 12, 2021, to December 29, 2021. Stakeholders within South Korea and metropolitan mental health welfare centers were targeted, but addiction management support centers, including officials, patients, and their families, were integrated as well. A literature review and survey, focus group interviews, a Delphi survey, and expert consultation contributed to comprehensive revisions and improvements of the mental health service model.
Results:
The proposed model for community mental health welfare centers emphasizes the expansion of personnel and infrastructure, with a focus on severe mental illnesses and suicide prevention. The model for metropolitan mental health welfare centers delineates essential tasks in areas such as project planning and establishment, community research, and education about severe mental illnesses. The establishment of a 24-hour emergency intervention center was a crucial feature. In the integrated addiction support center model, the need to promote addiction management is defined as an essential task and the establishment of national governance for addiction policies is recommended.
Conclusion
This study proposed standard operating models for three types of mental health service centers. To meet the increasing need for community care, robust mental health service delivery systems are of primary importance.
10.A Real-World, Prospective, Observational Study of Rivaroxaban on Prevention of Stroke and Non-Central Nervous Systemic Embolism in Renally Impaired Korean Patients With Non-Valvular Atrial Fibrillation:XARENAL
Il-Young OH ; Chang Hoon LEE ; Eue-Keun CHOI ; Hong Euy LIM ; Yong-Seog OH ; Jong-Il CHOI ; Min-Soo AHN ; Ju Youn KIM ; Nam-Ho KIM ; Namsik YOON ; Martin SANDMANN ; Kee-Joon CHOI
Korean Circulation Journal 2025;55(2):121-131
Background and Objectives:
Several real-world studies have been done in patients with nonvalvular atrial fibrillation (NVAF); however, information on its safety profile in patients with renal impairment is limited. XARENAL, a real-world study, aimed to prospectively investigate the safety profile of rivaroxaban in patients with NVAF with renal impairment (creatinine clearance [CrCl], 15–49 mL/min).
Methods:
XARENAL is an observational single-arm cohort study in renal impairment NVAF patients. Patients were followed up approximately every 3 months for 1 year or until 30 days following early discontinuation. The primary endpoint was major bleeding events. All adverse events, symptomatic thromboembolic events, treatment duration, and renal function change from baseline were the secondary endpoints.
Results:
XARENAL included 888 patients from 29 study sites. Overall, 713 (80.3%) had moderate renal impairment (CrCl, 30–49 mL/min), and 175 (19.7%) had severe renal impairment (CrCl, 15–29 mL/min) with a mean estimated glomerular filtration rate (eGFR) of 45.2±13.0 mL/min/1.73 m 2 . The mean risk scores were 3.3±1.4 and 1.7±0.9 for CHA 2 DS 2 -VASc score and HAS-BLED score, respectively. An incidence proportion of 5.6% (6.2 events per 100 patient-years) developed major bleeding; however, fatal bleeding occurred in 0.5% (0.5 events per 100 patient-years). The mean change in the eGFR was 2.22±26.47 mL/min/1.73 m 2 per year.
Conclusions
XARENAL observed no meaningful differences in major bleeding events from other previous findings as well as renal function changes in rivaroxaban-treated NVAF patients with renal impairment, which is considered to be acceptable in clinical practice.

Result Analysis
Print
Save
E-mail