1.Delayed Retroperitoneal Hematoma Following Intradiscal Electrothermal Therapy: A Case Report of a Rare Complication
Jun-Yong CHA ; Yun-Young PARK ; Jin-Uk KIM ; Jun-Ho LEE ; Seong-Hwan MUN ; Gun AHN ; Il-Tae JANG
The Nerve 2026;12(1):36-40
Intradiscal electrothermal therapy (IDET) is a minimally invasive procedure used to treat discogenic back pain and offers an alternative to surgical intervention in selected patients. Although it is generally considered safe, rare but significant complications can occur and may be difficult to diagnose because their symptoms overlap with those of other spinal conditions. We describe the case of a 69-year-old woman who presented with severe lower back and left buttock pain that was unresponsive to conservative treatment. Magnetic resonance imaging revealed disc bulging with a high-intensity zone at the L4–5 and L5–S1 levels. IDET was performed at the L4–5 level, resulting in initial pain relief. However, the patient returned 7 days later with recurrent pain. Despite undergoing percutaneous epidural neuroplasty at the left L5–S1 level, a medial branch block, and a piriformis muscle block, her symptoms persisted. Further evaluation with spinal computed tomography revealed a retroperitoneal hematoma near the left psoas muscle. Referred pain from the hematoma mimicked discogenic pain, resulting in delayed diagnosis and unnecessary interventions. The patient remained hemodynamically stable and gradually improved with conservative management alone. This case highlights retroperitoneal hematoma as a rare complication of IDET and emphasizes the importance of accurate and timely diagnosis in patients with persistent or worsening symptoms after spinal procedures. Clinicians should consider non-discogenic sources of pain when treatment outcomes deviate from expected patterns.
2.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
3.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
4.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
5.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
6.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
7.Independent and Combined Effects of Particulate Matter and Sleep Deprivation on Human Skin Barrier
Il Joo KWON ; Eun Jung LEE ; Jong Ho PARK ; Ji Young KIM ; Seohyun PARK ; Yu Jeong BAE ; Shinwon HWANG ; Hye-won NA ; Nari CHA ; Geunhyuk JANG ; Hyoung-June KIM ; Hae Kwang LEE ; Sang Ho OH
Annals of Dermatology 2025;37(3):131-139
Background:
The exposome encompasses all factors people encounter through life, with the skin constantly exposed. While particulate matter (PM) and sleep deprivation are known to contribute to barrier dysfunction, their combined effects remain unclear.
Objective:
To evaluate the independent and combined effects of PM exposure and short-term sleep deprivation on skin barrier function.
Methods:
Forty healthy Korean women (aged 24–58 years) were enrolled in this study. Forearms were divided into 4 sites: control, PM exposure, sleep deprivation, and PM plus sleep deprivation. Parameters such as trans-epidermal water loss (TEWL), hydration, elasticity, roughness, and redness were measured at baseline and post-exposure. RNA sequencing and reverse transcription-polymerase chain reaction were conducted on tape-stripped skin samples.
Results:
PM exposure significantly increased TEWL (+25.59%, p<0.01), roughness (+21.9%, p<0.01), and redness (+13.7%, p<0.0001) while reducing elasticity (−3.98%, p<0.01). Sleep deprivation modestly reduced elasticity (−1.39%, p<0.05) without affecting other parameters.Combined PM and sleep deprivation did not further exacerbate barrier dysfunction compared to PM alone. RNA sequencing revealed reduced FLG and LORICRIN expression and upregulated endoplasmic reticulum (ER) stress markers (HSP90B1, CANX) in both PM and sleep deprivation conditions.
Conclusion
PM exposure impaired skin barrier function, while short-term sleep deprivation alone did not significantly affect the barrier, either independently or in combination with PM.However, it was observed that the sleep deprivation-only, while not directly causing barrier damage, induced changes in ER stress-related gene expression in tape-stripped skin samples, like the PM exposure-only. This suggests that such signaling pathways could potentially exacerbate skin barrier deterioration.
8.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
9.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
10.Diagnostic accuracy of preoperative ultrasound in predicting diffuse sclerosing variant papillary thyroid carcinoma: a retrospective diagnostic accuracy study
Buseon KANG ; Hyeong Won YU ; Yoon KONG ; Ja Kyung LEE ; June Young CHOI ; Hee Young NA ; So Yeon PARK ; Min Joo KIM ; Jae Hoon MOON ; Wonjae CHA ; Woo-Jin JEONG ; Won Woo LEE ; Hunjong LIM ; Sang Il CHOI
Annals of Surgical Treatment and Research 2025;109(1):35-43
Purpose:
Diffuse sclerosing variant papillary thyroid carcinoma (DSV-PTC) is a rare and aggressive subtype of PTC.Preoperative diagnosis is challenging owing to the overlapping of imaging characteristics with those of other thyroid conditions. This study aimed to evaluate the accuracy of preoperative ultrasound (US) in predicting DSV-PTC and to identify significant diagnostic factors.
Methods:
This retrospective study analyzed 34 patients who were preoperatively suspected of having DSV-PTC based on US findings and later underwent thyroidectomy. Patients were divided into 2 groups based on the final histopathological diagnosis: DSV-PTC and non-DSV-PTC. Demographic, radiological, and pathological characteristics were also compared.
Results:
Only 32.4% of patients initially suspected of having DSV-PTC were confirmed postoperatively. Among the US features, the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) score 5 was significantly associated with DSV-PTC (P = 0.038), whereas other radiological factors, including echogenicity and microcalcifications, were not. The histopathological features, such as tumor size, BRAF and TERT mutations, vascular invasion, and lymph node metastasis, showed no significant differences between the groups.
Conclusion
Preoperative US has limited accuracy (32.4%) in diagnosing DSV-PTC. Because of the aggressive treatment recommendations based on preoperative suspicion, clinicians should carefully consider the limitations of imaging. Further studies incorporating fine-needle aspiration or core needle biopsy are required to improve diagnostic accuracy.

Result Analysis
Print
Save
E-mail