1.Impact of Low-Density Lipoprotein Cholesterol Levels on Atherosclerotic Vascular Changes: Analysis of Korean Treat Stroke to Target Trial
Sang Hee HA ; Jae-Chan RYU ; Sung Hee AHN ; Jae-Kwan CHA ; Sang Min SUNG ; Tae-Jin SONG ; Kyung Bok LEE ; Eung-Gyu KIM ; Yong-Won KIM ; Ji Hoe HEO ; Man Seok PARK ; Kyusik KANG ; Byung-Chul LEE ; Keun-Sik HONG ; Oh Young BANG ; Jei KIM ; Jong S. KIM
Journal of Stroke 2026;28(2):330-333
2.Ethnic Heterogeneity in Reproductive Risk Factors for Breast Cancer, With a Focus on Asian Populations:A Meta-analysis
Youjin HONG ; Soseul SUNG ; Woojin LIM ; Sungji MOON ; Kwang-Pil KO ; Jung Eun LEE ; Inah KIM ; Sun Ha JEE ; Sun-Seog KWEON ; Min-Ho SHIN ; Sangmin PARK ; Seung-Ho RYU ; Sun Young YANG ; Jeongseon KIM ; Sang-Wook YI ; Sue K. PARK
Journal of Cancer Prevention 2026;31(1):20-27
suggest that some reproductive factors associated with BC differ across ethnicities and time trends, perhaps due to the prevalence of reproductive factors and the baseline hazard of BC.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Association between Caffeinated Beverages Consumption and Sleep Quality of Urban Workers
Byung Il HWANG ; Ji-Young LEE ; Hyeon Jeong LIM ; Ryun HUH ; Mikyung RYU ; Sun Ha JEE ; Heejin KIMM
Korean Journal of Health Promotion 2025;25(1):9-19
Background:
The stimulatory effects of caffeine contribute to poor sleep quality. However, the relationship between caffeinated beverages and sleep quality, considering frequency or types of caffeinated beverages, were not extensively studied.
Methods:
Data were collected from 160 urban workers (75 men [46.9%] aged 20–69 years; with an average age of 41.8±12.3 years) using a structured, self-administered online questionnaire. Sleep quality, time, satisfaction; types and frequency of caffeinated beverages (number of cups per week; Q1: 0 cup, Q4: 14 or more cups per week), demographics, and health behaviors were asked. Sleep quality were evaluated using the Korean version of the Pittsburgh Sleep Quality Index (PSQI-K). Multiple regression analysis was conducted on the association between the frequency of caffeinated beverages consumption and sleep quality.
Results:
The most frequently consumed beverages were unsweetened coffee (22.8%) and the most common time for caffeine was between 12 pm to 5 pm (58.2%). The average sleep quality score based on the PSQI-K was 6.0±2.0 overall, 5.3±1.6 in Q1, and 6.6±2.2 in Q4 (frequent caffeinated beverage drinkers), indicating poorer sleep quality in Q4 (P=0.022). In Q1, 13.3% rated their sleep quality as ‘very good,’ while in Q4, only 2.5% gave the same rating. Poor sleep quality was significantly associated with the frequency of caffeinated beverages per week (β=0.232, P=0.004) and self-reported stress level (β=0.256, P=0.002).
Conclusions
Frequent consumption of caffeinated beverages appears to be associated with poor sleep quality among urban workers. While reducing caffeine intake may contribute to improvements in sleep quality as a health promoting behavior, this hypothesis requires validation through future studies employing personalized intervention approaches.
5.Association between Caffeinated Beverages Consumption and Sleep Quality of Urban Workers
Byung Il HWANG ; Ji-Young LEE ; Hyeon Jeong LIM ; Ryun HUH ; Mikyung RYU ; Sun Ha JEE ; Heejin KIMM
Korean Journal of Health Promotion 2025;25(1):9-19
Background:
The stimulatory effects of caffeine contribute to poor sleep quality. However, the relationship between caffeinated beverages and sleep quality, considering frequency or types of caffeinated beverages, were not extensively studied.
Methods:
Data were collected from 160 urban workers (75 men [46.9%] aged 20–69 years; with an average age of 41.8±12.3 years) using a structured, self-administered online questionnaire. Sleep quality, time, satisfaction; types and frequency of caffeinated beverages (number of cups per week; Q1: 0 cup, Q4: 14 or more cups per week), demographics, and health behaviors were asked. Sleep quality were evaluated using the Korean version of the Pittsburgh Sleep Quality Index (PSQI-K). Multiple regression analysis was conducted on the association between the frequency of caffeinated beverages consumption and sleep quality.
Results:
The most frequently consumed beverages were unsweetened coffee (22.8%) and the most common time for caffeine was between 12 pm to 5 pm (58.2%). The average sleep quality score based on the PSQI-K was 6.0±2.0 overall, 5.3±1.6 in Q1, and 6.6±2.2 in Q4 (frequent caffeinated beverage drinkers), indicating poorer sleep quality in Q4 (P=0.022). In Q1, 13.3% rated their sleep quality as ‘very good,’ while in Q4, only 2.5% gave the same rating. Poor sleep quality was significantly associated with the frequency of caffeinated beverages per week (β=0.232, P=0.004) and self-reported stress level (β=0.256, P=0.002).
Conclusions
Frequent consumption of caffeinated beverages appears to be associated with poor sleep quality among urban workers. While reducing caffeine intake may contribute to improvements in sleep quality as a health promoting behavior, this hypothesis requires validation through future studies employing personalized intervention approaches.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Association between Caffeinated Beverages Consumption and Sleep Quality of Urban Workers
Byung Il HWANG ; Ji-Young LEE ; Hyeon Jeong LIM ; Ryun HUH ; Mikyung RYU ; Sun Ha JEE ; Heejin KIMM
Korean Journal of Health Promotion 2025;25(1):9-19
Background:
The stimulatory effects of caffeine contribute to poor sleep quality. However, the relationship between caffeinated beverages and sleep quality, considering frequency or types of caffeinated beverages, were not extensively studied.
Methods:
Data were collected from 160 urban workers (75 men [46.9%] aged 20–69 years; with an average age of 41.8±12.3 years) using a structured, self-administered online questionnaire. Sleep quality, time, satisfaction; types and frequency of caffeinated beverages (number of cups per week; Q1: 0 cup, Q4: 14 or more cups per week), demographics, and health behaviors were asked. Sleep quality were evaluated using the Korean version of the Pittsburgh Sleep Quality Index (PSQI-K). Multiple regression analysis was conducted on the association between the frequency of caffeinated beverages consumption and sleep quality.
Results:
The most frequently consumed beverages were unsweetened coffee (22.8%) and the most common time for caffeine was between 12 pm to 5 pm (58.2%). The average sleep quality score based on the PSQI-K was 6.0±2.0 overall, 5.3±1.6 in Q1, and 6.6±2.2 in Q4 (frequent caffeinated beverage drinkers), indicating poorer sleep quality in Q4 (P=0.022). In Q1, 13.3% rated their sleep quality as ‘very good,’ while in Q4, only 2.5% gave the same rating. Poor sleep quality was significantly associated with the frequency of caffeinated beverages per week (β=0.232, P=0.004) and self-reported stress level (β=0.256, P=0.002).
Conclusions
Frequent consumption of caffeinated beverages appears to be associated with poor sleep quality among urban workers. While reducing caffeine intake may contribute to improvements in sleep quality as a health promoting behavior, this hypothesis requires validation through future studies employing personalized intervention approaches.
8.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
9.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
10.Association between Caffeinated Beverages Consumption and Sleep Quality of Urban Workers
Byung Il HWANG ; Ji-Young LEE ; Hyeon Jeong LIM ; Ryun HUH ; Mikyung RYU ; Sun Ha JEE ; Heejin KIMM
Korean Journal of Health Promotion 2025;25(1):9-19
Background:
The stimulatory effects of caffeine contribute to poor sleep quality. However, the relationship between caffeinated beverages and sleep quality, considering frequency or types of caffeinated beverages, were not extensively studied.
Methods:
Data were collected from 160 urban workers (75 men [46.9%] aged 20–69 years; with an average age of 41.8±12.3 years) using a structured, self-administered online questionnaire. Sleep quality, time, satisfaction; types and frequency of caffeinated beverages (number of cups per week; Q1: 0 cup, Q4: 14 or more cups per week), demographics, and health behaviors were asked. Sleep quality were evaluated using the Korean version of the Pittsburgh Sleep Quality Index (PSQI-K). Multiple regression analysis was conducted on the association between the frequency of caffeinated beverages consumption and sleep quality.
Results:
The most frequently consumed beverages were unsweetened coffee (22.8%) and the most common time for caffeine was between 12 pm to 5 pm (58.2%). The average sleep quality score based on the PSQI-K was 6.0±2.0 overall, 5.3±1.6 in Q1, and 6.6±2.2 in Q4 (frequent caffeinated beverage drinkers), indicating poorer sleep quality in Q4 (P=0.022). In Q1, 13.3% rated their sleep quality as ‘very good,’ while in Q4, only 2.5% gave the same rating. Poor sleep quality was significantly associated with the frequency of caffeinated beverages per week (β=0.232, P=0.004) and self-reported stress level (β=0.256, P=0.002).
Conclusions
Frequent consumption of caffeinated beverages appears to be associated with poor sleep quality among urban workers. While reducing caffeine intake may contribute to improvements in sleep quality as a health promoting behavior, this hypothesis requires validation through future studies employing personalized intervention approaches.

Result Analysis
Print
Save
E-mail