1.Differential Ultrasonographic Diagnosis of Liver Masses
Jae Young JANG ; Tom RYU ; Young CHANG ; Soung Won JEONG
Clinical Ultrasound 2025;10(1):9-15
Hepatic masses include a variety of benign and malignant lesions originating in the liver, and ultrasonography is one of the most basic and essential imaging tools for evaluating these lesions. This review comprehensively summarizes the ultrasonographic findings of hepatic masses by lesion type and examines the interpretation and clinical significance of each. In regions like Korea, where chronic liver disease is highly prevalent, the role of ultrasonography is particularly important. Accurate diagnosis and formulation of treatment strategies require skilled interpretation of ultrasound images.
3.Optimal extent of lymph node dissection in clinical early-stage right colon cancer: a retrospective analysis
Hyeung-min PARK ; Jaram LEE ; Soo Young LEE ; Suk Hee HEO ; Yong Yeon JEONG ; Hyeong Rok KIM ; Chang Hyun KIM
Annals of Surgical Treatment and Research 2025;108(1):49-56
Purpose:
Determining the extent of radical lymphadenectomy at clinical early stage is challenging. We aimed to investigate the appropriate extent of lymphadenectomy in clinical early-stage right colon cancer.
Methods:
Patients with clinical stage 0 or I right colon cancer who underwent curative surgery from January 2007 to December 2021 were included in this retrospective study. The extent of lymph node (LN) metastases based on the distribution of LN metastases (LND: LND1 pericolic nodes, LND2 intermediate nodes, LND3 apical nodes), along with the depth of submucosal (SM) invasion (classed into SM1–3), were analyzed.
Results:
Of the 348 patients, distribution across pathologic stages was as follows: 30 patients (8.6%) at stage 0, 207 (59.5%) at stage I, 52 (14.9%) at stage II, and 59 (17.0%) at stage III. In pT1 tumor patients, LN metastases varied by SM invasion depth: 3.6% in SM1 (all LND1), 5.1% in SM2 (all LND1), and 17.5% in SM3 (LND1 10%, LND2 5%, LND3 2.5%). For pT2, pT3, and pT4 stages, LN metastasis rates were 16.2% (LND1 11.3%, LND2 3.8%, LND3 1.3%), 39.7% (LND1 28.9%, LND2 8.4%, LND3 2.4%), and 50% (LND1 25%, LND2 25%), respectively. Tumor invasion depth and lymphovascular invasion were identified as significant risk factors for LN metastasis extending to LND2–3.
Conclusion
Complete mesocolic excision should be considered for right-sided colon cancer because tumor infiltration deeper than SM2 could metastasize to LND2 or further. If preoperative endoscopy confirms SM1 or SM2 invasion, D2 lymphadenectomy could be a limited surgical option.
4.Subperiosteal ganglion of the distal radius: a case report
Young Ho ROH ; Ho Hyup KIM ; Kyung Ryeol LEE ; Chang Lim HYUN ; Kyu Bum SEO
Archives of hand and microsurgery 2025;30(2):114-120
Subperiosteal ganglion is a rare lesion with an unclear pathogenesis that develops from the periosteum with cortical erosion. It most commonly occurs in the tibia and occurs less frequently in the upper extremities. We report a case of subperiosteal ganglion at the ulnar side of the metaphysis of the distal radius in a 27-year-old woman, and we describe the diagnosis and treatment.
5.Analysis of Changes in Relative Value Scale and Frequency of Surgery and Procedures in Surgery Departments Over the Past 18 Years: Secondary Publication
Jae Hoon CHO ; Sei Young LEE ; Seung Hoon LEE ; Seog-Kyun MUN ; Jung Hyun CHANG ; Chan-Soon PARK
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):67-73
Background and Objectives:
The purpose of this study was to compare and analyze the 18- year change in the relative value scale (RVS) in otolaryngology in relation to other surgical departments so as to help make future policy decisions.Subjects and Method Data on RVSs and addition rates, the deparments of main managed care, frequency of practice, and number of specialists were collected for all surgeries and procedures conducted in 2004, 2008, 2013, 2018, and 2022. Among these, an analysis was conducted for nine surgical departments. The number of surgeries and procedure items, the median value of the RVS, and the usage amount (i.e., RVS of all items multiplied by the frequency of surgeries and procedures) were calculated.
Results:
Over the past 18 years, the increase in the number of surgeries, procedure items and RVS in otolaryngology has grown smaller than that in other surgical departments, and the usage has decreased very sharply; in essence, the usage per specialist has actually decreased compared to 18 years ago.
Conclusion
Compared to other departments, RVS in otorhinolaryngology has shown very little change over the past period of 18 years. It is necessary to reasonably increase the currently undervalued RVS in otorhinolaryngology, particularly focusing on surgeries and procedures.
6.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
7.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
8.The Utilization of Navigation and Emerging Technologies With Endoscopic Spine Surgery: A Narrative Review
Abhinav K. SHARMA ; Rafael Garcia DE OLIVEIRA ; Siravich SUVITHAYASIRI ; Piya CHAVALPARIT ; Chien Chun CHANG ; Yong H. KIM ; Charla R. FISCHER ; Sang LEE ; Samuel CHO ; Jin-Sung KIM ; Don Young PARK
Neurospine 2025;22(1):105-117
Endoscopic spine surgery (ESS) is growing in popularity worldwide. An expanding body of literature demonstrates rapid functional recovery with reduced morbidity compared to open techniques. Both full endoscopic spine surgery, or uniportal endoscopy, and unilateral biportal endoscopy (UBE) can be employed in conjunction with various navigation and enabling technologies for assistance with localization of anatomic orientation and assessment of the intraoperative target spinal pathology. This review article describes various navigation technologies in ESS, including 2-dimensional (2D) fluoroscopic imaging, 2D fluoroscopic navigation, 3-dimensional C-arm navigation, augmented reality, and spinal robotics. Employment of enabling navigation and emerging technology with the registration of patient-specific anatomy enables clear delineation of anatomic landmarks and facilitation of a successful procedure. Additionally, avoidance of common pitfalls during use of navigation systems in ESS is discussed in this review.
9.Comparative Analysis of Ultrasound and Surgical Findings in Anatomical Variations of de Quervain’s Disease
Young Seok LEE ; Wan-Sun CHOI ; Seung Hun BAEK ; Hyunwoo KANG ; Chang-Hun LEE
Clinics in Orthopedic Surgery 2025;17(2):308-316
Background:
This study compares ultrasound and surgical findings of anatomical variations in de Quervain’s disease.
Methods:
Seventy-four wrists from patients with unilateral de Quervain’s disease were examined through ultrasonography and surgery. Presence of intracompartment septum, abductor pollicis longus (APL) slips, and selective stenosis were verified by both methods. Two orthopedic surgeons assessed ultrasound findings for intra- and interobserver reliability.
Results:
Amongst 74 participants (43 women and 31 men), 60.8% had a complete septum, 31.1% had an incomplete septum, and 8.1% had no septum; 70.3% had multi-slip APL and 66.2% had extensor pollicis brevis stenosis. Surgical and ultrasonographic findings displayed a high level of sensitivity and specificity. Intraobserver reliability was high, and interobserver reliability was substantial.
Conclusions
The study confirms ultrasonography’s reliability in identifying anatomical variations in de Quervain’s disease, with high sensitivity, specificity, and substantial intra- and interobserver reliability, emphasizing its usefulness in preoperative assessment and planning.
10.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.

Result Analysis
Print
Save
E-mail