1.46,XY disorder of sex development caused by PPP1R12A gene variants: a case report.
Wei SU ; Zhe SU ; Jing-Yu YOU ; Hui-Ping SU ; Li-Li PAN ; Shu-Min FAN ; Jian-Chun YIN
Chinese Journal of Contemporary Pediatrics 2025;27(8):1017-1021
The patient was a boy aged 1 year and 9 months who presented with 46,XY disorder of sex development (DSD), with severe undermasculinization of the external genitalia. Laboratory tests and ultrasound examinations showed normal functions of Leydig cells and Sertoli cells in the testes. Genetic testing revealed a novel pathogenic heterozygous variant, c.1186dupA (p.T396Nfs*17), in the PPP1R12A gene. Thirteen cases of PPP1R12A gene variants have been reported previously. These variants may cause isolated involvement of the genitourinary or neurological systems, or affect other systems/organs including the digestive tract, eyes, heart, etc. Patients with DSD typically present with a 46,XY karyotype and variable degrees of undermasculinization involving the external genitalia, gonads, and reproductive tract. This article reports a child with 46,XY DSD accompanied by growth retardation caused by a heterozygous variant in the PPP1R12A gene, which expands the clinical disease spectrum associated with PPP1R12A gene variants.
Humans
;
Male
;
Infant
;
Disorder of Sex Development, 46,XY/etiology*
;
Protein Phosphatase 1/genetics*
2.Cellular and Histopathological Characteristics of Ultrasonically Underdiagnosed 3/4a Thyroid Nodules.
Wu WEI-QI ; Xu CUN-BAO ; Li YOU-JIA ; Su CHUN-YANG ; Feng-Shun ZHANG ; Yi-Feng CHEN
Acta Academiae Medicinae Sinicae 2025;47(1):23-28
Objective To analyze the cellular and histopathological characteristics of underdiagnosed thyroid nodules of Chinese thyroid imaging reporting and data system(C-TIRADS) categories 3 and 4a,thus improving the understanding of these lesions. Methods The data of ultrasound and fine needle aspiration cytology were collected from 683 nodules diagnosed based on pathological evidence in 549 patients undergoing thyroid surgery.The cellular and histopathological characteristics of C-TIRADS 3 and 4a nodules were analyzed. Results Two hundred and sixty-eight nodules were classified as C-TIRADS category 3,including 236 benign nodules,12 low-risk ones,and 20 (7.46%) malignant ones.Two hundred and twenty-one nodules were classified as C-TIRADS category 4a,including 133 benign nodules,7 low-risk ones,and 81 (36.65%) malignant ones.The malignancy rates differed between C-TIRADS 3 and 4a nodules (χ2=58.93,P<0.001),and both were higher than the recommended malignancy rate in the guidelines for malignancy risk stratification of thyroid nodules (C-TIRADS) (both P<0.001).According to the pathological evidence,the underdiagnosed C-TIRADS 3/4a nodules were mainly papillary thyroid carcinoma,especially in patients with Hashimoto thyroiditis.There was not a consistent one-to-one match between each ultrasound result and each cytological classification of low-risk thyroid nodules.Conclusions When the malignant features in preoprative ultrasound imaging are atypical or absent,papillary thyroid carcinoma (especially with Hashimoto thyroiditis),follicular carcinoma,and medullary carcinoma are likely to be underdiagnosed as C-TIRADS 3 or 4a nodules.Therefore,efforts should be made to fully understand the cellular and pathological characteristics of these lesions.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Female
;
Male
;
Middle Aged
;
Adult
;
Ultrasonography
;
Biopsy, Fine-Needle
;
Aged
;
Young Adult
;
Thyroid Neoplasms/diagnostic imaging*
;
Adolescent
3.Data-independent Acquisition-Based Quantitative Proteomic Analysis Reveals Potential Salivary Biomarkers of Primary Sj?gren's Syndrome
Tian YI-CHAO ; Guo CHUN-LAN ; Li ZHEN ; You XIN ; Liu XIAO-YAN ; Su JIN-MEI ; Zhao SI-JIA ; Mu YUE ; Sun WEI ; Li QIAN
Chinese Medical Sciences Journal 2024;39(1):19-28,中插3
Objective As primary Sj?gren's syndrome(pSS)primarily affects the salivary glands,saliva can serve as an indicator of the glands'pathophysiology and the disease's status.This study aims to illustrate the salivary proteomic profiles of pSS patients and identify potential candidate biomarkers for diagnosis. Methods The discovery set contained 49 samples(24 from pSS and 25 from age-and gender-matched healthy controls[HCs])and the validation set included 25 samples(12 from pSS and 13 from HCs).Totally 36 pSS patients and 38 HCs were centrally randomized into the discovery set or to the validation set at a 2:1 ratio.Unstimulated whole saliva samples from pSS patients and HCs were analyzed using a data-independent acquisition(DIA)strategy on a 2D LC-HRMS/MS platform to reveal differential proteins.The crucial proteins were verified using DIA analysis and annotated using gene ontology(GO)and International Pharmaceutical Abstracts(IPA)analysis.A prediction model for SS was established using random forests. Results A total of 1,963 proteins were discovered,and 136 proteins exhibited differential representation in pSS patients.The bioinformatic research indicated that these proteins were primarily linked to immunological functions,metabolism,and inflammation.A panel of 19 protein biomarkers was identified by ranking order based on P-value and random forest algorichm,and was validated as the predictive biomarkers exhibiting good performance with area under the curve(AUC)of 0.817 for discovery set and 0.882 for validation set. Conclusions The candidate protein panel discovered may aid in pSS diagnosis.Salivary proteomic analysis is a promising non-invasive method for prognostic evaluation and early and precise treatments for pSS patients.DIA offers the best time efficiency and data dependability and may be a suitable option for future research on the salivary proteome.
4.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
5.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
6.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
7.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
8.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
9.Development status of electric vertical takeoff and landing aircraft and its application in aeromedical rescue
Shao-Chun YOU ; Xiao-Li ZHANG ; Fei-Fei WU ; Zheng-Xue LUO
Chinese Medical Equipment Journal 2024;45(2):82-86
Electric vertical takeoff and landing(eVTOL)aircraft was introduced from the aspects of basic concept,development history,classification mode,characteristic and advantage.The feasibility of eVTOL aircraft used in aeromedical rescue was discussed in terms of time,space,transport capacity and safety.It's pointed out that eVTOL aircraft would be applied widely in pre-hospital emergency care,inter-hospital transfer and emergency medical rescue.[Chinese Medical Equipment Journal,2024,45(2):82-86]
10.Improved YOLOv5s-based lesion area detection method for ophthalmic ultrasound images
You ZHOU ; Ze-Meng LI ; Xin-Qi YU ; Xiao-Chun WANG ; Sheng ZHOU
Chinese Medical Equipment Journal 2024;45(11):1-7
Objective To propose an improved YOLOv5s-based lesion area detection method for ophthalmic ultrasound images so as to solve the problems due to high complexity,difficult deployment and low accuracy of the model during ophthalmic ultrasound imaging detection and diagnosis.Methods Firstly,an ophthalmic ultrasound image dataset was established contai-ning Lhe images of stellate vitreous degeneration,retinal detachment,vitreous hemorrhage,posterior vitreous detachment and posterior scleral staphyloma.Secondly,a YOLOv5s-MobileNetV2 model was constructed based on YOLOv5s with the original backbone feature extraction network CSPDarkNet replaced by the lightweight network MobileNet.Thirdly,the model's performance in recognizing lesion areas in ophthalmic ultrasound images was evaluated by multi-category mean average precision(mAP),number of parameters and frames per second(FPS).Finally,the intelligent detection software for ophthalmic ultrasound images was designed based on PyQt5 library.Results The YOLOv5s-MobileNetV2 model had the mAP,number of parameters and FPS being 97.73%,4.61×106 and 47 f/s respectively,which gained advantages in timeliness over YOLOv5s by decreasing the mAP by 0.22%and the number of parameters by 34.98%.The developed intelligent detection software for ophthalmic ultrasound images behaved in human-computer interaction and clinical applicability of YOLOv5s-MobileNetV2 model.Conclusion The improved YOLOv5s-based lesion area detection method for ophthalmic ultrasound images meets clinical diagnosis requirements for ophthalmic diseases by involving in lightweight models and detecting lesion areas accurately.[Chinese Medical Equipment Journal,2024,45(11):1-7]

Result Analysis
Print
Save
E-mail