1.2020 Seoul Consensus on the Diagnosis and Management of Gastroesophageal Reflux Disease
Hye-Kyung JUNG ; Chung Hyun TAE ; Kyung Ho SONG ; Seung Joo KANG ; Jong Kyu PARK ; Eun Jeong GONG ; Jeong Eun SHIN ; Hyun Chul LIM ; Sang Kil LEE ; Da Hyun JUNG ; Yoon Jin CHOI ; Seung In SEO ; Joon Sung KIM ; Jung Min LEE ; Beom Jin KIM ; Sun Hyung KANG ; Chan Hyuk PARK ; Suck Chei CHOI ; Joong Goo KWON ; Kyung Sik PARK ; Moo In PARK ; Tae Hee LEE ; Seung Young KIM ; Young Sin CHO ; Han Hong LEE ; Kee Wook JUNG ; Do Hoon KIM ; Hee Seok MOON ; Mi-Young CHOI ; Kwang Jae LEE ;
Korean Journal of Medicine 2022;97(2):70-92
Gastroesophageal reflux disease (GERD) is a condition in which gastric contents regurgitate into the esophagus or beyond, resulting in either troublesome symptoms or complications. GERD is heterogeneous in terms of varied manifestations, test findings, and treatment responsiveness. GERD diagnosis can be established with symptomatology, pathology, or physiology. Recently the Lyon consensus defined the “proven GERD” with concrete evidence for reflux, including advanced grade erosive esophagitis (Los Angeles classification grades C and or D esophagitis), long-segment Barrett’s mucosa or peptic strictures on endoscopy or distal esophageal acid exposure time > 6% on 24-hour ambulatory pH-impedance monitoring. However, some Asian researchers have different opinions on whether the same standards should be applied to the Asian population. The prevalence of GERD is increasing in Asia. The present evidence-based guidelines were developed using a systematic review and meta-analysis approach. In GERD with typical symptoms, a proton pump inhibitor test can be recommended as a sensitive, cost-effective, and practical test for GERD diagnosis. Based on a meta-analysis of 19 estimated acid-exposure time values in Asians, the reference range upper limit for esophageal acid exposure time was 3.2% (95% confidence interval 2.7-3.9%) in the Asian countries. Esophageal manometry and novel impedance measurements, including mucosal impedance and a post-reflux swallow-induced peristaltic wave, are promising in discrimination of GERD among different reflux phenotypes, thus increasing its diagnostic yield. We also propose a long-term strategy of evidence-based GERD treatment with proton pump inhibitors and other drugs.
2.2020 Seoul Consensus on the Diagnosis and Management of Gastroesophageal Reflux Disease
Hye-Kyung JUNG ; Chung Hyun TAE ; Kyung Ho SONG ; Seung Joo KANG ; Jong Kyu PARK ; Eun Jeong GONG ; Jeong Eun SHIN ; Hyun Chul LIM ; Sang Kil LEE ; Da Hyun JUNG ; Yoon Jin CHOI ; Seung In SEO ; Joon Sung KIM ; Jung Min LEE ; Beom Jin KIM ; Sun Hyung KANG ; Chan Hyuk PARK ; Suck Chei CHOI ; Joong Goo KWON ; Kyung Sik PARK ; Moo In PARK ; Tae Hee LEE ; Seung Young KIM ; Young Sin CHO ; Han Hong LEE ; Kee Wook JUNG ; Do Hoon KIM ; Hee Seok MOON ; Hirota MIWA ; Chien-Lin CHEN ; Sutep GONLACHANVIT ; Uday C GHOSHAL ; Justin C Y WU ; Kewin T H SIAH ; Xiaohua HOU ; Tadayuki OSHIMA ; Mi-Young CHOI ; Kwang Jae LEE ; The Korean Society of Neurogastroenterology and Motility
Journal of Neurogastroenterology and Motility 2021;27(4):453-481
Gastroesophageal reflux disease (GERD) is a condition in which gastric contents regurgitate into the esophagus or beyond, resulting in either troublesome symptoms or complications. GERD is heterogeneous in terms of varied manifestations, test findings, and treatment responsiveness. GERD diagnosis can be established with symptomatology, pathology, or physiology. Recently the Lyon consensus defined the “proven GERD” with concrete evidence for reflux, including advanced grade erosive esophagitis (Los Angeles classification grades C and or D esophagitis), long-segment Barrett’s mucosa or peptic strictures on endoscopy or distal esophageal acid exposure time > 6% on 24-hour ambulatory pH-impedance monitoring. However, some Asian researchers have different opinions on whether the same standards should be applied to the Asian population. The prevalence of GERD is increasing in Asia. The present evidence-based guidelines were developed using a systematic review and meta-analysis approach. In GERD with typical symptoms, a proton pump inhibitor test can be recommended as a sensitive, cost-effective, and practical test for GERD diagnosis.Based on a meta-analysis of 19 estimated acid-exposure time values in Asians, the reference range upper limit for esophageal acid exposure time was 3.2% (95% confidence interval, 2.7-3.9%) in the Asian countries. Esophageal manometry and novel impedance measurements, including mucosal impedance and a post-reflux swallow-induced peristaltic wave, are promising in discrimination of GERD among different reflux phenotypes, thus increasing its diagnostic yield. We also propose a long-term strategy of evidence-based GERD treatment with proton pump inhibitors and other drugs.
3.2020 Seoul Consensus on the Diagnosis and Management of Gastroesophageal Reflux Disease
Hye-Kyung JUNG ; Chung Hyun TAE ; Kyung Ho SONG ; Seung Joo KANG ; Jong Kyu PARK ; Eun Jeong GONG ; Jeong Eun SHIN ; Hyun Chul LIM ; Sang Kil LEE ; Da Hyun JUNG ; Yoon Jin CHOI ; Seung In SEO ; Joon Sung KIM ; Jung Min LEE ; Beom Jin KIM ; Sun Hyung KANG ; Chan Hyuk PARK ; Suck Chei CHOI ; Joong Goo KWON ; Kyung Sik PARK ; Moo In PARK ; Tae Hee LEE ; Seung Young KIM ; Young Sin CHO ; Han Hong LEE ; Kee Wook JUNG ; Do Hoon KIM ; Hee Seok MOON ; Hirota MIWA ; Chien-Lin CHEN ; Sutep GONLACHANVIT ; Uday C GHOSHAL ; Justin C Y WU ; Kewin T H SIAH ; Xiaohua HOU ; Tadayuki OSHIMA ; Mi-Young CHOI ; Kwang Jae LEE ; The Korean Society of Neurogastroenterology and Motility
Journal of Neurogastroenterology and Motility 2021;27(4):453-481
Gastroesophageal reflux disease (GERD) is a condition in which gastric contents regurgitate into the esophagus or beyond, resulting in either troublesome symptoms or complications. GERD is heterogeneous in terms of varied manifestations, test findings, and treatment responsiveness. GERD diagnosis can be established with symptomatology, pathology, or physiology. Recently the Lyon consensus defined the “proven GERD” with concrete evidence for reflux, including advanced grade erosive esophagitis (Los Angeles classification grades C and or D esophagitis), long-segment Barrett’s mucosa or peptic strictures on endoscopy or distal esophageal acid exposure time > 6% on 24-hour ambulatory pH-impedance monitoring. However, some Asian researchers have different opinions on whether the same standards should be applied to the Asian population. The prevalence of GERD is increasing in Asia. The present evidence-based guidelines were developed using a systematic review and meta-analysis approach. In GERD with typical symptoms, a proton pump inhibitor test can be recommended as a sensitive, cost-effective, and practical test for GERD diagnosis.Based on a meta-analysis of 19 estimated acid-exposure time values in Asians, the reference range upper limit for esophageal acid exposure time was 3.2% (95% confidence interval, 2.7-3.9%) in the Asian countries. Esophageal manometry and novel impedance measurements, including mucosal impedance and a post-reflux swallow-induced peristaltic wave, are promising in discrimination of GERD among different reflux phenotypes, thus increasing its diagnostic yield. We also propose a long-term strategy of evidence-based GERD treatment with proton pump inhibitors and other drugs.
4.Three-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI.
Hee Woo CHO ; Jin Suck SUH ; Jin Oh PARK ; Hyoung Sik KIM ; Soo Yoon CHUNG ; Young Han LEE ; Seok HAHN
Yonsei Medical Journal 2017;58(6):1186-1194
PURPOSE: To evaluate the diagnostic performance of three-dimensional fast spin-echo (3D FSE-Cube) without fat suppression (NFS) for detecting knee lesions, using comparison to 3D FSE-Cube with fat suppression (FS). MATERIALS AND METHODS: One hundred twenty-four patients who underwent 1.5T knee magnetic resonance imaging (MRI) scans and 25 subsequent arthroscopic surgeries were retrospectively reviewed. Using arthroscopic results and two-dimensional images as reference standards, diagnostic performances of 3D FSE-Cube-NFS and FS imaging about lesions of ligament, meniscus, subchondral bone marrow edema (BME), and cartilage were compared. Scan parameters of 3D FSE-Cube imaging were previously optimized by a porcine knee phantom. RESULTS: No significant differences were observed between detection rates of NFS and FS imaging for detecting lesions of meniscus and cartilage (p>0.05). However, NFS imaging had lower sensitivity for detection of medial collateral ligament (MCL) tears, and lower sensitivity and specificity for detection of BME lesions, compared to FS imaging (p<0.05). CONCLUSION: 3D FSE-Cube-NFS imaging showed similar diagnostic performance for detecting lesions of meniscus or cartilage compared to FS imaging, unlike MCL or BME lesions.
Arthroscopy
;
Bone Marrow
;
Cartilage
;
Collateral Ligaments
;
Edema
;
Humans
;
Imaging, Three-Dimensional
;
Knee*
;
Ligaments
;
Magnetic Resonance Imaging*
;
Retrospective Studies
;
Sensitivity and Specificity
;
Tears
5.Clinical Meaning of Neutrophil-to-Lymphocyte Ratio (NLR)in Papillary Thyroid Carcinoma.
Yung Il SHIN ; Ja Young CHO ; Yu Mi LEE ; Tae Yon SUNG ; Jong Ho YOON ; Ki Wook CHUNG ; Suck Joon HONG
Korean Journal of Endocrine Surgery 2016;16(2):31-35
PURPOSE: Neutrophil-to-lymphocyte ratio (NLR) is a marker of systemic inflammatory response, which is inexpensive, easily calculated, and known to show correlation with prognosis of cancer. The aim of this study was to evaluate the relationship between NLR and prognosis of papillary thyroid carcinoma. METHODS: A total of 1,142 patients who underwent total thyroidectomy for papillary thyroid carcinoma between 1995~2005 at Asan Medical Center were enrolled in this study. Patients were categorized according to two groups based on NLR and clinico-pathological variables and disease survival were compared between the two groups. RESULTS: Median age of patients was 45.4 years, and the median follow-up period was 48 months. The cut-off value of NLR for prediction of disease-free survival (DFS) was 2. Comparison of DFS between two groups stratified by NLR (NLR ≤2, NLR>2) showed little statistical difference (P=0.48). After adjusting for risk (N stage), there was no significant difference according to N stage (N0: P=0.86, N1a: P=0.4, N1b: P=0.12). CONCLUSION: NLR did not show correlation with disease free survival of papillary thyroid carcinoma.
Chungcheongnam-do
;
Disease-Free Survival
;
Follow-Up Studies
;
Humans
;
Prognosis
;
Thyroid Gland*
;
Thyroid Neoplasms*
;
Thyroidectomy
6.Risk Factors for Distant Metastasis in Patients with Follicular Thyroid Carcinoma.
Min Kyu SUNG ; Yu Mi LEE ; Tae Yon SUNG ; Jong Ho YOON ; Ki Wook CHUNG ; Suck Joon HONG
Korean Journal of Endocrine Surgery 2016;16(2):25-30
PURPOSE: The major issue of follicular thyroid carcinoma (FTC) diagnosed after hemithyroidectomy is whether to undergo further treatments. The aim of this study is to examine the clinico-pathological characteristics of FTC and to evaluate the risk factors for distant metastasis. METHODS: From 1993 to 2010, 274 patients underwent initial thyroid surgery and were subsequently diagnosed as FTC. After review of the histological sections by an experienced pathologist, 211 patients were confirmed as FTC and were enrolled in this study. Clinicopathological features were compared based on the presence or absence of distant metastases, and the risk factors for distant metastases and distant metastases-free survival (DMFS) rates were analyzed. RESULTS: The patients included 39 males (18.5%) and 172 females (81.5%), with a mean age of 44.0±14.5 years. The median follow-up period was 99.5 months (range, 13.0~222.0). Distant metastases were detected in 23 patients (10.9%), including 15 synchronous distant metastases and 8 metachronous distant metastases. In multivariate analysis, age ≥45 years, widely invasive FTC, tumor size ≥4.3 cm, and vascular invasion were independent risk factors for distant metastasis. DMFS rates in patients with these risk factors were significantly poorer than those in patients without these risk factors. CONCLUSION: Older age, aggressive histological classification, larger tumor size, and vascular invasion were independent risk factors for distant metastasis. FTC patients with these risk factors may be candidates for further treatments after diagnostic thyroid hemithyroidectomy.
Adenocarcinoma, Follicular*
;
Classification
;
Female
;
Follow-Up Studies
;
Humans
;
Male
;
Multivariate Analysis
;
Neoplasm Metastasis*
;
Risk Factors*
;
Survival Rate
;
Thyroid Gland
7.Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging.
Yeon Hwa YOO ; Choon Sik YOON ; Na Lae EUN ; Moon Jung HWANG ; Hanna YOO ; Robert D PETERS ; Tae Sub CHUNG ; Young Han LEE ; Jin Suck SUH ; Sungjun KIM
Korean Journal of Radiology 2016;17(6):903-911
OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1–2 through L5–S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05. RESULTS: The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001). CONCLUSION: The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs.
Humans
;
Intervertebral Disc Degeneration
;
Intervertebral Disc*
;
Magnetic Resonance Imaging*
;
Male
;
Spine
;
Volunteers
8.Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?.
Hee Woo CHO ; Jin Oh PARK ; Young Han LEE ; Soo Yoon CHUNG ; Jin Suck SUH
Investigative Magnetic Resonance Imaging 2015;19(4):224-230
PURPOSE: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). MATERIALS AND METHODS: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. RESULTS: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. CONCLUSION: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.
Humans
;
Magnetic Resonance Imaging*
;
Research Personnel
;
Retrospective Studies
;
Spine*
;
Thyroid Gland*
;
Thyroid Nodule*
;
Ultrasonography*
9.Accuracy of Diffusion Tensor Imaging for Diagnosing Cervical Spondylotic Myelopathy in Patients Showing Spinal Cord Compression.
Seungbo LEE ; Young Han LEE ; Tae Sub CHUNG ; Eun Kee JEONG ; Sungjun KIM ; Yeon Hwa YOO ; In Seong KIM ; Choon Sik YOON ; Jin Suck SUH ; Jung Hyun PARK
Korean Journal of Radiology 2015;16(6):1303-1312
OBJECTIVE: To assess the performance of diffusion tensor imaging (DTI) for the diagnosis of cervical spondylotic myelopathy (CSM) in patients with deformed spinal cord but otherwise unremarkable conventional magnetic resonance imaging (MRI) findings. MATERIALS AND METHODS: A total of 33 patients who underwent MRI of the cervical spine including DTI using two-dimensional single-shot interleaved multi-section inner volume diffusion-weighted echo-planar imaging and whose spinal cords were deformed but showed no signal changes on conventional MRI were the subjects of this study. Mean diffusivity (MD), longitudinal diffusivity (LD), radial diffusivity (RD), and fractional anisotropy (FA) were measured at the most stenotic level. The calculated performance of MD, FA, MD∩FA (considered positive when both the MD and FA results were positive), LD∩FA (considered positive when both the LD and FA results were positive), and RD∩FA (considered positive when both the RD and FA results were positive) in diagnosing CSM were compared with each other based on the estimated cut-off values of MD, LD, RD, and FA from receiver operating characteristic curve analysis with the clinical diagnosis of CSM from medical records as the reference standard. RESULTS: The MD, LD, and RD cut-off values were 1.079 × 10⁻³, 1.719 × 10⁻³, and 0.749 × 10⁻³ mm²/sec, respectively, and that of FA was 0.475. Sensitivity, specificity, positive predictive value and negative predictive value were: 100 (4/4), 44.8 (13/29), 20 (4/20), and 100 (13/13) for MD; 100 (4/4), 27.6 (8/29), 16 (4/25), and 100 (8/8) for FA; 100 (4/4), 58.6 (17/29), 25 (4/16), and 100 (17/17) for MD∩FA; 100 (4/4), 68.9 (20/29), 30.8 (4/13), and 100 (20/20) for LD∩FA; and 75 (3/4), 68.9 (20/29), 25 (3/12), and 95.2 (20/21) for RD∩FA in percentage value. Diagnostic performance comparisons revealed significant differences only in specificity between FA and MD∩FA (p = 0.003), FA and LD∩FA (p < 0.001), FA and RD∩FA (p < 0.001), MD and LD∩FA (p = 0.024) and MD and RD∩FA (p = 0.024). CONCLUSION: Fractional anisotropy combined with MD, RD, or LD is expected to be more useful than FA and MD for diagnosing CSM in patients who show deformed spinal cords without signal changes on MRI.
Adult
;
Aged
;
Aged, 80 and over
;
Cervical Vertebrae
;
*Diffusion Tensor Imaging
;
Echo-Planar Imaging
;
Female
;
Humans
;
Male
;
Middle Aged
;
ROC Curve
;
Sensitivity and Specificity
;
Severity of Illness Index
;
Spinal Cord Compression/*diagnosis/pathology/radiography
;
Spinal Cord Diseases/*diagnosis/pathology/radiography
10.Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle.
Yeon Hwa YOO ; Hak Sun KIM ; Young Han LEE ; Choon Sik YOON ; Mun Young PAEK ; Hanna YOO ; Stephan KANNENGIESSER ; Tae Sub CHUNG ; Ho Taek SONG ; Jin Suck SUH ; Sungjun KIM
Korean Journal of Radiology 2015;16(5):1086-1095
OBJECTIVE: To assess whether multi-echo Dixon magnetic resonance (MR) imaging with simultaneous T2* estimation and correction yields more accurate fat-signal fraction (FF) measurement of the lumbar paravertebral muscles, in comparison with non-T2*-corrected two-echo Dixon or T2*-corrected three-echo Dixon, using the FF measurements from single-voxel MR spectroscopy as the reference standard. MATERIALS AND METHODS: Sixty patients with low back pain underwent MR imaging with a 1.5T scanner. FF mapping images automatically obtained using T2*-corrected Dixon technique with two (non-T2*-corrected), three, and six echoes, were compared with images from single-voxel MR spectroscopy at the paravertebral muscles on levels L4 through L5. FFs were measured directly by two radiologists, who independently drew the region of interest on the mapping images from the three sequences. RESULTS: A total of 117 spectroscopic measurements were performed either bilaterally (57 of 60 subjects) or unilaterally (3 of 60 subjects). The mean spectroscopic FF was 14.3 +/- 11.7% (range, 1.9-63.7%). Interobserver agreement was excellent between the two radiologists. Lin's concordance correlation between the spectroscopic findings and all the imaging-based FFs were statistically significant (p < 0.001). FFs obtained from the T2*-corrected six-echo Dixon sequences showed a significantly better concordance with the spectroscopic data, with its concordance correlation coefficient being 0.99 and 0.98 (p < 0.001), as compared with two- or three-echo methods. CONCLUSION: T2*-corrected six-echo Dixon sequence would be a better option than two- or three-echo methods for noninvasive quantification of lumbar muscle fat quantification.
Adult
;
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Image Processing, Computer-Assisted
;
Low Back Pain/*radiography
;
Magnetic Resonance Imaging/instrumentation/*methods
;
Male
;
Middle Aged
;
Muscles/radiography
;
Spinal Cord

Result Analysis
Print
Save
E-mail