1.Shifting the Paradigm of Medical Dispute Resolution: From Individual Punishment to System Improvement and Public Compensation
Hee Gyung KANG ; Eun Kyung EO ; Duseop KWON ; Sung-ju KIM ; HaDa RYUOK ; Serng Bai PAK ; Junghee AHN ; Minsu OCK ; Mihwa YOO ; Sang-il LEE ; Eunyoung CHO ; Eun Jin HA ; DongSeok HAN ; Juhwan OH
Korean Journal of Family Practice 2026;16(1):25-32
Legal risks and liability issues in medical practice serve as a primary catalyst for the current collapse of essential healthcare services in Korea. Currently, medical disputes in Korea are disproportionately focused on criminal prosecutions and high-damages civil litigation. This punitive approach fosters a culture of concealment, encourages defensive medicine, and accelerates the exodus of medical professionals from essential fields. Ultimately, this cycle deprives the system of opportunities for improvement and poses a significant threat to patient safety. In contrast, many advanced nations have adopted principles of “Just Culture” and “Safe Space,” prioritizing non-punitive reporting and systemic root-cause analysis over individual retribution. To address these issues, this paper proposes four key strategies: First, the establishment of an independent “Patient Safety Investigation Agency” to objectively investigate incidents and identify systemic flaws. Second, a transition from criminal punishment to licensing board-led management, focusing on re-education and counseling to maintain quality of care. Third, the enactment of “Apology Laws” to ensure that expressions of regret or apologies cannot be used as legal evidence of liability, thereby fostering trust and psychological recovery. Finally, the creation of a “Patient Safety Fund” to provide prompt and sufficient public compensation to victims regardless of proven negligence. In conclusion, it is imperative to shift the paradigm by defining medical accidents as “system failures” rather than individual faults. Strengthening the social safety net will encourage medical professionals to return to essential care and build a sustainable healthcare environment centered on patient safety.
2.A comparative analysis of surgical outcomes after robotic gastrectomy with conventional multiport, single-site, and single-port surgical system for gastric cancer
Ki-Yoon KIM ; Jawon HWANG ; Sung Hyun PARK ; Minah CHO ; Yoo Min KIM ; Woo Jin HYUNG ; Hyoung-Il KIM
Annals of Surgical Treatment and Research 2026;110(4):216-224
Purpose:
Technological advancements have enabled reduced-port robotic systems, enhancing the benefits of robotic surgery. This study compared the surgical outcomes of conventional multiport (5 ports), single-site (2 ports), and singleport (2 ports) robotic gastrectomy for gastric cancer.
Methods:
A prospectively collected database was retrospectively reviewed for patients who underwent robotic distal subtotal gastrectomy between January 2010 and August 2022 at Severance Hospital, Yonsei University Health System. The initial 20 cases from each group (multiport, single-site, and SP) were analyzed, focusing on demographics, surgical procedures, pathological results, and postoperative outcomes. The “textbook outcome” metric was employed to assess surgical quality.
Results:
The SP group showed lower visual analog pain scale compared to the multiport and single-site groups (3.5, 4.4, and 4.3, respectively, P = 0.017), faster time to first flatus (2.0, 2.7, and 2.8 days, respectively; P < 0.001), and shorter hospital stays (3.5, 6.2, and 5.5 days, respectively; P < 0.001). No significant differences were observed in major complications, unplanned intensive care unit care, readmission, or mortality between the groups. The rate of patients achieving textbook outcomes were 85.0% for the multiport group, 100% for the single-site group, and 95.0% for the SP group (P = 0.310).
Conclusion
Reduced-port robotic gastrectomy, including single-site and SP, has shown surgical safety with a high proportion of patients meeting textbook outcomes. The SP system demonstrated less pain and faster recovery, aligning with minimally invasive surgical goals. Therefore, the SP system could be a reliable and safe option for robotic gastrectomy, offering enhanced recovery without compromising surgical quality.
3.Different Long-Term Outcomes According to Thrombus Histology in Patients With Acute Ischemic Stroke
Hyungwoo LEE ; JoonNyung HEO ; Jae Wook JUNG ; Hyo Suk NAM ; Ji Hoe HEO ; Minyoul BAIK ; Joonsang YOO ; Jinkwon KIM ; Tae-Jin SONG ; Gyu Sik KIM ; Kwon-Duk SEO ; Tae Dong OK ; Jin Kyo CHOI ; Il KWON ; Young Dae KIM ;
Journal of Stroke 2026;28(2):263-272
Background:
and Purpose The relationship between thrombus histology and long-term stroke patient outcomes remains unexplored. We aimed to determine whether the histological characteristics of thrombi are associated with long-term outcomes in stroke patients and to identify the thrombus features linked to these outcomes.
Methods:
This retrospective multicenter cohort study included 512 patients with ischemic stroke who underwent endovascular thrombectomy between July 2017 and July 2023. Patients were followed up for long-term major adverse cardiovascular events occurrence. Thrombus histology was assessed using immunohistochemistry, including the proportion of fibrin, red blood cells, and platelets, as well as the distribution patterns categorized as layered, erythrocytic, diffuse platelet, and mixed.
Results:
During a median follow-up of 38.1 months, 164 patients experienced major adverse cardiovascular events, with an incidence rate of 3.02 per 100 person-years. Major adverse cardiovascular events occurrence was associated with the diffuse platelet pattern and proportion of platelets and red blood cells within the thrombus. After adjusting for confounders, the diffuse platelet pattern independently predicted major adverse cardiovascular events, including mortality and stroke recurrence. Subgroup analysis also demonstrated that the association between the diffuse platelet pattern and major adverse cardiovascular events was consistent across key clinical subgroups based on age (≥65 vs. <65 yr), atrial fibrillation, cancer status, and discharge medications.
Conclusions
Thrombus histology could provide predictive value for long-term prognosis. In particular, histological distribution patterns may be more important than simple composition in thrombus research, including in the prediction of prognosis.
4.Cross-Calibration of Bone Mineral Density and Body Composition between GE Lunar Prodigy and Hologic Horizon W Dual Energy X-Ray Absorptiometry Systems
Sujin KIM ; Guen Young LEE ; Jun-Il YOO ; Sang-Wook LEE ; Yong-Chan HA
Journal of Bone Metabolism 2026;33(1):84-93
Background:
Dual energy X-ray absorptiometry (DXA) measurements vary among instruments from different manufacturers. This study aimed to assess the correlation between bone mineral density (BMD) and body composition measured by the GE Lunar Prodigy and Hologic Horizon W DXA systems and to develop conversion equations.
Methods:
A total of 120 healthy volunteers (59 males, 61 females) aged 20 to 70 years were scanned on both DXA systems on the same day. BMD was measured at the lumbar spine (L1-L4) and bilateral femurs. Body composition parameters were measured for the whole body and regional sites. Bland-Altman analysis, Pearson correlation, and concordance correlation coefficient (CCC) were used to assess agreement. Linear regression was performed to derive conversion equations.
Results:
The Hologic system measured BMD values 14% to 20% lower at the lumbar spine and 8% to 17% lower at femoral sites compared to the GE Lunar system (all P<0.0001). Lean mass values were 4% to 10% lower on the Hologic system. Very strong correlations were observed for both BMD (r=0.944-0.980) and lean mass (r=0.963-0.984). Cross-calibration equations were developed for all measurement sites.
Conclusions
Despite significant systematic differences, there was very high correlation between the two DXA systems. The conversion equations can facilitate comparison of measurements between these systems in clinical practice and research.
5.A Real-World Efficacy and Safety of KEYNOTE-522 Regimen in Patients With Early Triple-Negative Breast Cancer
Shinyoung LEE ; Hyehyun JEONG ; Yeokyeong SHIN ; Jae Ho JEONG ; Kyung Hae JUNG ; Sung-Bae KIM ; Byung-Kwan JEONG ; Hee Jin LEE ; Gyungyub GONG ; Hee Jung SHIN ; Hye Joung EOM ; Young-Jin LEE ; Tae-Kyung YOO ; Sae Byul LEE ; Jisun KIM ; Il-Yong CHUNG ; Beom-Seok KO ; Hee Jeong KIM ; Jong Won LEE ; Byung Ho SON ; Jin-Hee AHN
Journal of Breast Cancer 2026;29(2):141-153
Purpose:
Based on the KEYNOTE-522 study, neoadjuvant pembrolizumab plus chemotherapy has become the standard treatment for early-stage triple-negative breast cancer (TNBC).This study evaluated the real-world efficacy, safety, and predictors of pathologic complete response (pCR) in Korean patients.
Methods:
We conducted a retrospective cohort study of 174 patients with early-stage TNBC who received the KEYNOTE-522 regimen (neoadjuvant pembrolizumab plus paclitaxel and carboplatin, followed by doxorubicin and cyclophosphamide) at a tertiary cancer center between August 2022 and July 2024. We assessed the primary endpoints, including pCR rate and event-free survival (EFS). We performed univariable and multivariable logistic regression analyses to identify independent predictors of pCR.
Results:
The median patient age was 50 years (range, 24–74 years). The clinical stages were II and III in 79.3% and 20.1% of patients, respectively, and 10.9% had clinical N3 disease. The overall pCR rate was 62.1%, and the N3 subgroup had a pCR rate of 47.4%. On multivariable analysis, high baseline Ki-67 expression (≥ median, 75%) was significantly associated with pCR (odds ratio, 2.84; 95% confidence interval, 1.45 to 5.66; p = 0.002). At a median followup of 18.4 months, the 12-month EFS rate was 97.4%, with significantly superior outcomes observed in patients who achieved pCR compared with those who did not achieve pCR (100% vs. 93.1%, p = 0.007). The treatment completion rate was 92.0%, and immune-related adverse events occurred in 13.8% of patients.
Conclusion
In this real-world analysis of one of the largest Asian cohorts of patients with earlystage TNBC treated with neoadjuvant pembrolizumab, the KEYNOTE-522 regimen demonstrated substantial efficacy and manageable toxicity, consistent with the original trial findings.
6.Proximal Gastrectomy Is Associated with Lower Incidence of Anemia and Vitamin B12 Deficiency Compared to Total Gastrectomy in Patients with Upper Gastric Cancer
Jeong Ho SONG ; Sung Hyun PARK ; Minah CHO ; Yoo Min KIM ; Woo Jin HYUNG ; Hyoung-Il KIM
Cancer Research and Treatment 2025;57(1):174-185
Purpose:
Proximal gastrectomy is an alternative to total gastrectomy (TG) for early gastric cancer (EGC) treatment in the upper stomach. However, its benefits in terms of perioperative and long-term outcomes remain controversial. The aim of this study was to compare the perioperative, body compositional, nutritional, and survival outcomes of patients undergoing proximal gastrectomy with double-tract reconstruction (PG-DTR) and TG for pathological stage I gastric cancer in upper stomach.
Materials and Methods:
The study included 506 patients who underwent gastrectomy for pathological stage I gastric cancer in the upper stomach between 2015 and 2019. Clinicopathological, perioperative, body compositional, nutritional, and survival outcomes were compared between the PG-DTR and TG groups.
Results:
The PG-DTR and TG groups included 197 (38.9%) and 309 (61.1%) patients, respectively. The PG-DTR group had a lower rate of early complications (p=0.041), lower diagnosis rate of anemia and vitamin B12 deficiency (all p < 0.001), and lower replacement rate of iron and vitamin B12 compared to TG group (all p < 0.001). The PG-DTR group showed reduced incidence of sarcopenia at 6-months postoperatively, preserved higher amount of visceral fat after surgery (p=0.032 and p=0.040, respectively), and showed a higher hemoglobin level (p=0.007). Oncologic outcomes were comparable between the groups.
Conclusion
The PG-DTR for EGC located in the upper stomach offered advantages of fewer complications, lower incidence of anemia and vitamin B12 deficiency, less decrease in visceral fat volume, and similar survival compared to TG. Consequently, PG-DTR may be considered a superior alternative treatment option to TG.
7.Educational Level Modifies the Relationship between Standard Deviation of NN Intervals and Post-traumatic Stress Disorder Development over Two-years
Ji Min YOO ; Ju-Wan KIM ; Hee-Ju KANG ; Hyunseok JANG ; Jung-Chul KIM ; Ju-Yeon LEE ; Sung-Wan KIM ; Il-Seon SHIN ; Jae-Min KIM
Clinical Psychopharmacology and Neuroscience 2025;23(1):155-160
Objective:
This study investigated how educational levels modify the relationship between the standard deviation of NN intervals (SDNN) of heart rate variability and the development of post-traumatic stress disorder (PTSD).
Methods:
Participants with physical injuries were enrolled from a trauma center and monitored over two years. Initial assessments included SDNN and educational attainment, along with socio-demographic and clinical variables. PTSD diagnoses were made at 3, 6, 12, and 24 months post-injury using the Clinician-Administered PTSD Scale for DSM-5.Logistic regression analyses were conducted.
Results:
Of the 538 participants, 58 (10.8%) developed PTSD during the follow-up period. A significant interaction effect was observed: lower SDNN was significantly linked to PTSD in individuals with higher education, but not in those with lower education.
Conclusion
The study identified education-dependent associations between SDNN and PTSD development, emphasizing the importance of tailored PTSD prevention strategies that consider both SDNN and educational levels.
8.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
9.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
10.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.

Result Analysis
Print
Save
E-mail