1.Evaluation of the implementation of GBZ/T 201.5-2015 Radiation shielding requirements for radiotherapy rooms-Part 5: Radiotherapy room of proton accelerators
Zhibin ZHANG ; Bin BAI ; Hailiang LI ; Jie YAO ; Lantao LIU ; Jiayi MA ; Yongzhong MA
Chinese Journal of Radiological Health 2025;34(4):546-552
Objective To evaluate the current status in the implementation of GBZ/T 201.5-2015 Radiation shielding requirements for radiotherapy rooms-Part 5: Radiotherapy room of proton accelerators, identify issues in the application of its technical indicators, and provide a basis for the in-depth implementation and further revision of the standard. Methods In accordance with the Standardization Law of the People’s Republic of China and the Guidelines for Health Standards Tracking Evaluation (WS/T 536-2017), a combination of cluster sampling and stratified sampling methods was employed to select professionals involved in proton accelerator radiotherapy devices and facilities in three provinces (or municipalities directly under the central government) as the subjects of the survey. A questionnaire was developed to collect basic information about the subjects and their understanding and application of the technical indicators in the standard. A standard evaluation indicator system with a total score of 100 points was established to score the implementation of the standard (40 points), the technical content (30 points), and the effectiveness of the implementation (30 points). Results A total of 169 professionals from 107 institutions participated in the survey, with 79.88% of the respondents having at least 5 years of experience in radiation therapy and 74.56% holding intermediate or higher professional titles. The score of standard implementation was 18.3 points. The awareness rate exceeded 80%, indicating a high level of awareness about the standard. However, the scores for the dissemination and application of the standard were relatively low, accounting for 28% and 32% of their respective full marks. The technical content of the standard and the effectiveness of its implementation scored 27.0 and 26.6 points, respectively. The overall score in the evaluation of standard implementation was 72 points, with scores of 68.6, 72.3, and 75.0 for Beijing City, Shanghai City, and Jiangsu Province, respectively. Conclusion GBZ/T 201.5-2015 Radiation shielding requirements for radiotherapy rooms-Part 5: Radiotherapy room of proton accelerators is scientific and operable, and it is well-coordinated with relevant laws and standards. However, considering the development in FLASH technology and multi-chamber radiotherapy room, it is necessary to revise and improve the standard.
2.Assessment of the implementation of Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015)
Yuze YANG ; Hongfang WANG ; Haoxian YANG ; Quan WU ; Mingsheng LI ; Bala HARI ; Yongzhong MA ; Zechen FENG ; Bin BAI ; Jie GAO ; Wei ZHOU ; Weixu HUANG ; Zhengjie SHI ; Hezheng ZHAI
Chinese Journal of Radiological Health 2025;34(5):660-665
Objective To track and evaluate the implementation and application of the occupational health standard Radiation shielding requirements for radiotherapy room—Part 4: Radiotherapy room of 252Cf neutron afterloading (GBZ/T 201.4-2015) by radiation health technical service agencies, medical institutions, health supervision agencies, and radiotherapy facility design units, and to provide a scientific basis for the further revision and implementation of this standard. Methods Following the Guideline for health standards tracking evaluation (WS/T 536-2017) and the project implementation plan, relevant practitioners were randomly selected for a questionnaire survey. The survey primarily focused on their awareness, standard training, application, and revision suggestions of GBZ/T 201.4-2015. The results were summarized and analyzed. Results A total of 168 evaluation questionnaires were collected from relevant practitioners in 28 provinces. Only 31.6% of the respondents reported being “well familiar” or “ familiar” with the standard, 27.4% of the respondents believed that the standard was widely used, and 45.2% of the respondents believed that the standard could meet the needs of their work. Only 14.9% of the respondents had received relevant training on the standard, more than half of the respondents had not applied the standard within the past 10 years, and 45.2% of the respondents believed that the standard "needs to be revised". Conclusion Due to the small number of californium-252 neutron afterloading radiotherapy devices in operation on the market, the overall awareness of the standard is low, suggesting that relevant authorities need to strengthen training and publicity of the standard, and that certain sections of the standard need to be revised or merged.
3.Determination of radionuclide levels in food and assessment of effective dose in Beijing, China
Huan WANG ; Yaru SUN ; Meinan YAO ; Yongzhong MA ; Shuchang YAN ; Hui ZHANG ; Zhen WU ; Bin BAI
Chinese Journal of Radiological Health 2025;34(5):733-739
Objective To investigate the levels of radionuclides in food in Beijing, China, and assess the committed effective dose to local residents from food intake. Methods From 2021 to 2022, a total of 65 food samples across 7 categories were collected in Beijing. The activity concentrations of radionuclides, including 137Cs, 210Pb, 238U, 228Ra, 226Ra, 40K, 90Sr, 210Po, 3H and 14C, were measured using gamma spectrometry and radiochemical methods. By combining the monitoring results with dietary consumption data of Beijing residents and the internal dose coefficients for Chinese reference adult phantom, the committed effective dose was estimated. Results The levels of radionuclides in food in Beijing were within the normal background range, consistent with related surveys in China and abroad, with activity concentrations below national standard limits. No significant differences were found in the activity concentrations of 137Cs, 238U, 228Ra, 226Ra and 40K between food samples collected from key areas and those from control areas (P > 0.05). The committed effective doses calculated according to internal dose coefficients for Chinese reference adult male phantom and GB 18871-2002 were 0.26 mSv and 0.19 mSv, respectively. Based on the Chinese reference adult male phantom, the majority of the committed effective dose was attributed to 210Pb (45.1%), 228Ra (37.1%), 210Po (12.3%), and 226Ra (4.7%). Conclusion The levels of radionuclides in food in Beijing fluctuated within the background range, resulting in a low radiation dose burden to the population.
4.Measurement and analysis of radiation dose for 125I seed source production radiation workers in an enterprise
Qinghua MENG ; Yuxia KONG ; Bin BAI ; Yongzhong MA
Chinese Journal of Radiological Medicine and Protection 2025;45(1):49-55
Objective:To investigate the doses received by radiation workers from external and internal exposures during the production of 125I seed source, and to provide scientific basis for accurate evaluation of the annual doses of radiation workers. Methods:The production site and radiation workers of a 125I seed source production enterprise were determined as the survey objects. An AT1121 X/γ dosimeter was used to measure the ambient dose equivalent rate on the operation site such as welding and cleaning of the seed source, and the dose received by workers from external exposure was estimated. LiF (Mg, Cu, P) TLD dosimeters were used to measure the external doses to workers in a specific period. The doses obtained by the two method were compared and analyzed. The RG-50 air sampler and TC-30 iodine box were used to collect the workplace air, The activity concentration of 125I in the air was measured by using of the BE5030 high-purity germanium gamma spectrometer to estimate the internal dose to workers. The evaluation of doses was performed in accordance with the national standards GBZ 128-2019 and GBZ 129-2016. Results:The estimated annual dose to the worker′ hands is 24.5 mSv/year. The estimated maximum dose was 2.61 mSv/year. The maximum value of individual dose monitored was 2.42 mSv/year, basically consistent with the measured value on the basis of considering the actual work rotation. The maximum estimate of committed effective dose from internal exposure was 1.55 mSv, by a factor of up to 17 times the estimated external dose at the corresponding post.Conclusions:The radiation dose to the radiation workers’ hands is relatively high in the production of 125I seed source, so the protective measures for hands should be effectively strengthened. Meanwhile, the internal dose to the workers in the production process of 125I seed source should not be negelected. The ventilation of the site should be strengthened, the air flow direction should be planned, and the 125I activity concentration in the air should be regularly monitored.
5.Study on protective effect of medical X-ray diagnosis equipment based on risk analysis of correlation
Lin SONG ; Jun HAN ; Weijie ZHU ; Bin BAI ; Debiao YAO ; Yongzhong MA
China Medical Equipment 2025;22(5):99-104
Objective:To formulate refined management strategies to improve the operation quality and protective effect of medical X-ray diagnosis equipment based on the risk analysis of the correlation of medical X-ray diagnostic equipment.Methods:The used 41 medical X-ray diagnosis equipment in Fuwai Hospital,Chinese Academy of Medical Sciences from January 2022 to December 2023 were selected.According to different management modes for equipment,they were managed respectively by the conventional management mode(20 units)and the management mode with risk analysis of the correlation(21 units).The risk grades of correlation of management mode with risk analysis of the correlation were classified on the basis of the probability of risk and the degree of harm in medical X-ray diagnosis equipment.The protection management of equipment was conducted from three aspects included the location of equipment,the staffs and subjects.A self-made questionnaire was used to investigate the satisfactions of engineers of using management for equipment,operators,and staffs of operating and maintaining equipment for the two kinds of management modes.The protection quality,failure rate of equipment,and qualification rate of protection of medical X-ray diagnosis equipment under different management modes were compared.Results:The quality scores of operation safety,regular inspection,maintenance and repair,and shielding protection for radiation of medical X-ray diagnosis equipment that adopted the management mode with risk analysis of the correlation were respectively(92.14±3.36),(91.47±2.41),(92.54±3.32)and(91.69±3.57)points,all of which were higher than those of the conventional management mode,and the differences of them were statistically significant(t=16.396,17.368,19.688,14.401,P<0.05).The failure rate of the 21 medical X-ray diagnosis equipment that adopted the management mode with risk analysis of correlation was 0,which was lower than 20.00%of the conventional management mode.The qualified rate of protection was 95.23%,which was higher than 70.00%of the conventional management mode,and the differences of them were statistically significant(x2=4.654,4.608,P<0.05).The satisfaction scores of engineers of using equipment,operators and staffs of operating and maintaining equipment for the protective effect of adopting the management mode with risk analysis of correlation were respectively(94.69±4.02),(93.21±4.36)and(92.54±3.47)points,all of which were higher than those of the conventional management mode,and the differences were statistically significant(t=16.902,11.291,12.020,P<0.05).Conclusion:The process-based protection management strategy on the basis of risk analysis of correlation for medical X-ray diagnosis equipment can prevent risks of medical X-ray diagnostic equipment,and improve the operation quality of the equipment,and reduce the operation risks of the equipment,and maximize the enhancement for management quality of medical X-ray diagnosis equipment.
6.Textual Research on Key Information of Tibetan Medicine Classic Prescription Sanwei Qiangwei Powder
Ma BAI ; Chunqiao SHI ; Yizhen LANGKA ; Jiangling LUO ; Rangji CAI ; Erjiang HUA ; Yongzhong ZEWENG ; Qingji REN ; Silang JIANGYONG ; Yi ZHANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(9):2493-2502
Objective To systematically explore the prescription source,prescription composition,drug origin and processing,functional indications and clinical application of the classic Tibetan medicine Sanwei Qiangwei Powder,so as to provide scientific basis for its in-depth development,rational utilization and follow-up research.Methods By using methods of literature review,the ancient and modern Tibetan medical classics and modern literature such as'Ocha Jinmai' sporadic secret collection 'Zhigong Yi Suan Ji' were retrieved,and the prescription origin,medicinal material origin,processing technology,prescription solution,usage and dosage were studied and analyzed.Results The Sanwei Qiangwei Powder originated from the 'Ocha Jinmai'(《()》)written by Qiangba Minimatongwatundan in the 15th century.The book was written much earlier than the literature included in the 'Catalogue of Ancient Classic Prescriptions(Second Batch)'-the 'Selection of Tibetan Medicine Prescriptions·Longevity Baoru' in the 19th century.The prescription consists of 15 copies of Rosa rugosa,7 copies of Herpetospermum caudigerum,and 3 copies of Terminalia chebula Retz.It plays a significant effect on hepatobiliary diseases such as biliary fever,liver fever,primary headache,and headache after drinking in clinical practice.It is the core prescription for the treatment of Chiba-type diseases and has high development value.There are differences in the use site,dosage ratio,usage and dosage of medicinal materials in different literatures,and the dosage has been clarified by textual research and expert consultation.Conclusion This study sorted out and clarified the key information of Sanwei Qiangwei Powder,which laid a theoretical foundation for the inheritance and development,innovative application and modernization research of the prescription.
7.Measurement and analysis of radiation dose for 125I seed source production radiation workers in an enterprise
Qinghua MENG ; Yuxia KONG ; Bin BAI ; Yongzhong MA
Chinese Journal of Radiological Medicine and Protection 2025;45(1):49-55
Objective:To investigate the doses received by radiation workers from external and internal exposures during the production of 125I seed source, and to provide scientific basis for accurate evaluation of the annual doses of radiation workers. Methods:The production site and radiation workers of a 125I seed source production enterprise were determined as the survey objects. An AT1121 X/γ dosimeter was used to measure the ambient dose equivalent rate on the operation site such as welding and cleaning of the seed source, and the dose received by workers from external exposure was estimated. LiF (Mg, Cu, P) TLD dosimeters were used to measure the external doses to workers in a specific period. The doses obtained by the two method were compared and analyzed. The RG-50 air sampler and TC-30 iodine box were used to collect the workplace air, The activity concentration of 125I in the air was measured by using of the BE5030 high-purity germanium gamma spectrometer to estimate the internal dose to workers. The evaluation of doses was performed in accordance with the national standards GBZ 128-2019 and GBZ 129-2016. Results:The estimated annual dose to the worker′ hands is 24.5 mSv/year. The estimated maximum dose was 2.61 mSv/year. The maximum value of individual dose monitored was 2.42 mSv/year, basically consistent with the measured value on the basis of considering the actual work rotation. The maximum estimate of committed effective dose from internal exposure was 1.55 mSv, by a factor of up to 17 times the estimated external dose at the corresponding post.Conclusions:The radiation dose to the radiation workers’ hands is relatively high in the production of 125I seed source, so the protective measures for hands should be effectively strengthened. Meanwhile, the internal dose to the workers in the production process of 125I seed source should not be negelected. The ventilation of the site should be strengthened, the air flow direction should be planned, and the 125I activity concentration in the air should be regularly monitored.
8.Textual Research on Key Information of Tibetan Medicine Classic Prescription Sanwei Qiangwei Powder
Ma BAI ; Chunqiao SHI ; Yizhen LANGKA ; Jiangling LUO ; Rangji CAI ; Erjiang HUA ; Yongzhong ZEWENG ; Qingji REN ; Silang JIANGYONG ; Yi ZHANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(9):2493-2502
Objective To systematically explore the prescription source,prescription composition,drug origin and processing,functional indications and clinical application of the classic Tibetan medicine Sanwei Qiangwei Powder,so as to provide scientific basis for its in-depth development,rational utilization and follow-up research.Methods By using methods of literature review,the ancient and modern Tibetan medical classics and modern literature such as'Ocha Jinmai' sporadic secret collection 'Zhigong Yi Suan Ji' were retrieved,and the prescription origin,medicinal material origin,processing technology,prescription solution,usage and dosage were studied and analyzed.Results The Sanwei Qiangwei Powder originated from the 'Ocha Jinmai'(《()》)written by Qiangba Minimatongwatundan in the 15th century.The book was written much earlier than the literature included in the 'Catalogue of Ancient Classic Prescriptions(Second Batch)'-the 'Selection of Tibetan Medicine Prescriptions·Longevity Baoru' in the 19th century.The prescription consists of 15 copies of Rosa rugosa,7 copies of Herpetospermum caudigerum,and 3 copies of Terminalia chebula Retz.It plays a significant effect on hepatobiliary diseases such as biliary fever,liver fever,primary headache,and headache after drinking in clinical practice.It is the core prescription for the treatment of Chiba-type diseases and has high development value.There are differences in the use site,dosage ratio,usage and dosage of medicinal materials in different literatures,and the dosage has been clarified by textual research and expert consultation.Conclusion This study sorted out and clarified the key information of Sanwei Qiangwei Powder,which laid a theoretical foundation for the inheritance and development,innovative application and modernization research of the prescription.
9.Study on protective effect of medical X-ray diagnosis equipment based on risk analysis of correlation
Lin SONG ; Jun HAN ; Weijie ZHU ; Bin BAI ; Debiao YAO ; Yongzhong MA
China Medical Equipment 2025;22(5):99-104
Objective:To formulate refined management strategies to improve the operation quality and protective effect of medical X-ray diagnosis equipment based on the risk analysis of the correlation of medical X-ray diagnostic equipment.Methods:The used 41 medical X-ray diagnosis equipment in Fuwai Hospital,Chinese Academy of Medical Sciences from January 2022 to December 2023 were selected.According to different management modes for equipment,they were managed respectively by the conventional management mode(20 units)and the management mode with risk analysis of the correlation(21 units).The risk grades of correlation of management mode with risk analysis of the correlation were classified on the basis of the probability of risk and the degree of harm in medical X-ray diagnosis equipment.The protection management of equipment was conducted from three aspects included the location of equipment,the staffs and subjects.A self-made questionnaire was used to investigate the satisfactions of engineers of using management for equipment,operators,and staffs of operating and maintaining equipment for the two kinds of management modes.The protection quality,failure rate of equipment,and qualification rate of protection of medical X-ray diagnosis equipment under different management modes were compared.Results:The quality scores of operation safety,regular inspection,maintenance and repair,and shielding protection for radiation of medical X-ray diagnosis equipment that adopted the management mode with risk analysis of the correlation were respectively(92.14±3.36),(91.47±2.41),(92.54±3.32)and(91.69±3.57)points,all of which were higher than those of the conventional management mode,and the differences of them were statistically significant(t=16.396,17.368,19.688,14.401,P<0.05).The failure rate of the 21 medical X-ray diagnosis equipment that adopted the management mode with risk analysis of correlation was 0,which was lower than 20.00%of the conventional management mode.The qualified rate of protection was 95.23%,which was higher than 70.00%of the conventional management mode,and the differences of them were statistically significant(x2=4.654,4.608,P<0.05).The satisfaction scores of engineers of using equipment,operators and staffs of operating and maintaining equipment for the protective effect of adopting the management mode with risk analysis of correlation were respectively(94.69±4.02),(93.21±4.36)and(92.54±3.47)points,all of which were higher than those of the conventional management mode,and the differences were statistically significant(t=16.902,11.291,12.020,P<0.05).Conclusion:The process-based protection management strategy on the basis of risk analysis of correlation for medical X-ray diagnosis equipment can prevent risks of medical X-ray diagnostic equipment,and improve the operation quality of the equipment,and reduce the operation risks of the equipment,and maximize the enhancement for management quality of medical X-ray diagnosis equipment.
10.Analysis of uranium concentration in surface water and drinking water in Beijing, China
Huan WANG ; Yaru SUN ; Meinan YAO ; Bin BAI ; Qinghua MENG ; Yongzhong MA
Chinese Journal of Radiological Health 2024;33(1):51-55
Objective To explore the uranium concentration in surface water and drinking water in Beijing, China and the relationship between uranium concentration and gross α activity concentration. Methods Water samples were collected from 16 districts in Beijing. Uranium concentration and gross α activity concentration were measured with WGJ-III trace uranium analyzer and LB6008 six-channel α/β counter using the ultraviolet fluorescence and thick source methods. Results The uranium concentrations in surface water and drinking water were 1.131 and 1.572 μg/L, respectively. The gross α activity concentrations in surface water and drinking water were 0.059 and 0.074 Bq/L, respectively. There were no significant differences in uranium concentration and gross α activity concentration between surface water and drinking water (P > 0.05). The uranium concentration was positively correlated with the gross α activity concentration, with a correlation coefficient of 0.700 (P < 0.05). The gross α activity concentration was determined by the uranium concentration with a determination coefficient of 48%. The committed effective dose of 238U in drinking water was between 3.284 × 10−5 and 1.640 × 10−3 mSv, with an average value of 5.400 × 10−4 mSv. Conclusion The uranium concentration and gross α activity in the surface water and drinking water in Beijing fluctuate and remain in the background range. These values are much lower than the recommended limits of 0.03 mg/L and 0.5 Bq/L stipulated in the GB 5749-2021 Standard for Drinking Water Quality. The annual committed effective dose of 238U through drinking water ingestion is very small.

Result Analysis
Print
Save
E-mail