1.Development and accuracy evaluation of a photogrammetry-based extraoral scanning system for edentulous implant placement
Yongtao YANG ; Aonan WEN ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Zixiang GAO ; Yujia ZHU ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2025;60(8):863-870
Objective:To evaluate the accuracy of a self-developed extraoral scanning system based on photogrammetry technology, and to provide evidence for advancing the development and clinical application evaluation of domestically produced scanning devices.Methods:This research group developed a photogrammetry-based implant extraoral scanning system with customized scan bodies. Two distinct edentulous implant resin models were designed and three-dimensional (3D)-printed by Center of Digital Dentistry, Peking University School and Hospital of Stomatology, containing 6 (Model 1) and 8 (Model 2) abutment analogs respectively. Reference data acquisition was performed using a high-precision denture 3D scanner with scan caps mounted on the analogs. Specialized scan bodies were then mounted on the analogs for 3D positional data acquisition using both the self-developed system (experimental group) and the clinically established system (control group). Each system conducted 10 repeated scans per model. Trueness was assessed through root mean square error (RMSE), linear deviation (LD), and angular deviation (AD) relative to reference data, while precision was determined through intra-group RMSE analysis. Systematic comparisons included inter-group performance on identical models and intra-group variability across different models.Results:For Model 1, the experimental group showed statistically significant advantages over controls in intra-group RMSE [(3.10±0.71) μm vs (4.61±1.51) μm, P<0.001], reference-data RMSE [(21.48±0.60) μm vs (32.50±0.63) μm, P<0.001], linear deviation [23.64 (32.35) μm vs 44.86 (55.73) μm, P<0.001], and angular deviation [0.29° (0.29°) vs 0.23° (0.33°), P<0.001]. In Model 2, significant improvements were observed in intra-group RMSE [(4.47±1.58) μm vs (6.21±2.07) μm, P<0.001], reference-data RMSE [(38.84±0.86) μm vs (43.69±1.34) μm, P<0.001], and linear deviation [37.95 (50.68) μm vs 49.71 (58.89) μm, P<0.001]. Both groups exhibited model-dependent variability, with RMSE of precision and trueness of both groups, linear deviation of experimental group, angular deviation of control group showing statistically significant increases (all P<0.001) corresponding to abutment analog quantity. Conclusions:The self-developed scanning system demonstrates superior accuracy in 3D positional acquisition of abutment analogs compared to the contral group system, with implant number identified as a critical determinant of extraoral scanning accuracy.
2.Simultaneous detection of 16 cephalosporin drugs in blood by UPLC-MS/MS
Yunqian LI ; Mengmeng LI ; Jing QIAO ; Shiyang QIN ; Baihui CHEN ; Kongwen ZHU ; Juanna WEI ; Yongtao LIU ; Junlei ZHANG ; Chenghao WU ; Guobin XIN
Chinese Journal of Forensic Medicine 2025;40(3):324-329,337
Objective To establish a method for the simultaneous determination of 16 cephalosporin antibiotics of the fourth generation in whole blood by ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS),including representative drugs such as cefalexin,cefuroxime axetil,cefetamet pivoxil,ceftizoxime,cefodizime,cefteram pivoxil,cefpodoxime proxetil,cefditoren pivoxil,cefminox sodium,cefoperazone,cefpirome,cefoxitin,cefamandole nafate,cefquinome sulfate,cefpiramide,and ceftiofur.Methods Whole blood was pretreated with acetonitrile for protein precipitation and then determined by ultra-high performance liquid chromatography-triple quadrupole mass spectrometry.The liquid phase used a Hypersil GOLD? C18 column(2.1 mm ×100 mm,1.9 μm).The organic phase was 0.1%formic acid methanol solution,and the aqueous phase was 0.1%formic acid aqueous solution(containing 10 mmol/mL ammonium formate)for gradient elution.Detection was performed in electrospray positive ionization mode with selected reaction monitoring(SRM).Results The 16 drugs showed good linearity within their respective concentration ranges,with R2 values all greater than 0.99.Limits of detection for cefminox sodium and cefpiramide were 50 and 20 ng/mL,respectively,and for the remaining 14 drugs were all lower than 5 ng/mL.The relative standard deviations(RSDs)of intra-day and inter-day precisions at four spiked concentrations for the 16 drugs were all no higher than 10%(n=5).Accuracy ranged within±15%for mosg drugs,except for cefamandole nafate,ceftiofur,and cefetamet pivoxil at the lower limit of quantification,which showed accuracy within±20%.Extraction recoveries exceeded 80%for all compounds.Conclusion This method has high detection sensitivity,rapid speed,and good repeatability for the simultaneously determination of 16 cephalosporin antibiotics in whole blood.
3.Simultaneous detection of 16 cephalosporin drugs in blood by UPLC-MS/MS
Yunqian LI ; Mengmeng LI ; Jing QIAO ; Shiyang QIN ; Baihui CHEN ; Kongwen ZHU ; Juanna WEI ; Yongtao LIU ; Junlei ZHANG ; Chenghao WU ; Guobin XIN
Chinese Journal of Forensic Medicine 2025;40(3):324-329,337
Objective To establish a method for the simultaneous determination of 16 cephalosporin antibiotics of the fourth generation in whole blood by ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS),including representative drugs such as cefalexin,cefuroxime axetil,cefetamet pivoxil,ceftizoxime,cefodizime,cefteram pivoxil,cefpodoxime proxetil,cefditoren pivoxil,cefminox sodium,cefoperazone,cefpirome,cefoxitin,cefamandole nafate,cefquinome sulfate,cefpiramide,and ceftiofur.Methods Whole blood was pretreated with acetonitrile for protein precipitation and then determined by ultra-high performance liquid chromatography-triple quadrupole mass spectrometry.The liquid phase used a Hypersil GOLD? C18 column(2.1 mm ×100 mm,1.9 μm).The organic phase was 0.1%formic acid methanol solution,and the aqueous phase was 0.1%formic acid aqueous solution(containing 10 mmol/mL ammonium formate)for gradient elution.Detection was performed in electrospray positive ionization mode with selected reaction monitoring(SRM).Results The 16 drugs showed good linearity within their respective concentration ranges,with R2 values all greater than 0.99.Limits of detection for cefminox sodium and cefpiramide were 50 and 20 ng/mL,respectively,and for the remaining 14 drugs were all lower than 5 ng/mL.The relative standard deviations(RSDs)of intra-day and inter-day precisions at four spiked concentrations for the 16 drugs were all no higher than 10%(n=5).Accuracy ranged within±15%for mosg drugs,except for cefamandole nafate,ceftiofur,and cefetamet pivoxil at the lower limit of quantification,which showed accuracy within±20%.Extraction recoveries exceeded 80%for all compounds.Conclusion This method has high detection sensitivity,rapid speed,and good repeatability for the simultaneously determination of 16 cephalosporin antibiotics in whole blood.
4.Development and accuracy evaluation of a photogrammetry-based extraoral scanning system for edentulous implant placement
Yongtao YANG ; Aonan WEN ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Zixiang GAO ; Yujia ZHU ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2025;60(8):863-870
Objective:To evaluate the accuracy of a self-developed extraoral scanning system based on photogrammetry technology, and to provide evidence for advancing the development and clinical application evaluation of domestically produced scanning devices.Methods:This research group developed a photogrammetry-based implant extraoral scanning system with customized scan bodies. Two distinct edentulous implant resin models were designed and three-dimensional (3D)-printed by Center of Digital Dentistry, Peking University School and Hospital of Stomatology, containing 6 (Model 1) and 8 (Model 2) abutment analogs respectively. Reference data acquisition was performed using a high-precision denture 3D scanner with scan caps mounted on the analogs. Specialized scan bodies were then mounted on the analogs for 3D positional data acquisition using both the self-developed system (experimental group) and the clinically established system (control group). Each system conducted 10 repeated scans per model. Trueness was assessed through root mean square error (RMSE), linear deviation (LD), and angular deviation (AD) relative to reference data, while precision was determined through intra-group RMSE analysis. Systematic comparisons included inter-group performance on identical models and intra-group variability across different models.Results:For Model 1, the experimental group showed statistically significant advantages over controls in intra-group RMSE [(3.10±0.71) μm vs (4.61±1.51) μm, P<0.001], reference-data RMSE [(21.48±0.60) μm vs (32.50±0.63) μm, P<0.001], linear deviation [23.64 (32.35) μm vs 44.86 (55.73) μm, P<0.001], and angular deviation [0.29° (0.29°) vs 0.23° (0.33°), P<0.001]. In Model 2, significant improvements were observed in intra-group RMSE [(4.47±1.58) μm vs (6.21±2.07) μm, P<0.001], reference-data RMSE [(38.84±0.86) μm vs (43.69±1.34) μm, P<0.001], and linear deviation [37.95 (50.68) μm vs 49.71 (58.89) μm, P<0.001]. Both groups exhibited model-dependent variability, with RMSE of precision and trueness of both groups, linear deviation of experimental group, angular deviation of control group showing statistically significant increases (all P<0.001) corresponding to abutment analog quantity. Conclusions:The self-developed scanning system demonstrates superior accuracy in 3D positional acquisition of abutment analogs compared to the contral group system, with implant number identified as a critical determinant of extraoral scanning accuracy.
5.Endovascular therapy for patients with acute ischemic stroke due to anterior circulation large vessel occlusion with early neurological deterioration: a retrospective case series study
Yongtao GUO ; Xiaofeng ZHU ; Mingchao LI
International Journal of Cerebrovascular Diseases 2024;32(7):487-494
Objective:To investigate the effectiveness and safety of endovascular therapy for patients with acute ischemic stroke (AIS) due to anterior circulation large vessel occlusion with early neurological deterioration (END).Methods:Patients with AIS due to anterior circulation large vessel occlusion with END underwent endovascular therapy under the multimodal imaging guidance in the Department of Neurology, Huai'an First Hospital Affiliated to Nanjing Medical University from June 2019 to April 2023 were collected retrospectively. The modified Thrombolysis in Cerebral Infarction (mTICI) grading was used to evaluate the vascular recanalization, and grade 2b or 3 was defined as successful recanalization. At 90 days after onset, the modified Rankin Scale (mRS) was used to evaluate the functional outcome, and 0-2 was defined as a good outcome. The patients with onset to femoral artery puncture time ≤24 hours and >24 hours were compared.Results:A total of 19 patients were enrolled, including 13 males, aged 61.16±11.75 years. The median baseline National Institutes of Health Stroke Scale (NIHSS) score was 4 (interquartile range, 2-5), and the median NIHSS score at END was 13 (interquartile range, 10-20). Twelve patients (63.2%) received intravenous thrombolysis before END. Median baseline Alberta Stroke Project Early CT Score (ASPECTS) was 8 (interquartile range, 7-9); 18 patients (94.7%) achieved successful recanalization, and 2 (10.5%) experienced symptomatic intracranial hemorrhage (sICH). At 90 days after onset, the mRS scores: 0-2 in 12 cases (63.2%), 3 in 4 cases (21.1%), 5 in 1 case (5.2%), and 6 (death) in 2 cases (10.5%). There were 10 patients (52.6%) in the group with onset time to femoral artery puncture ≤24 hours, and 9 patients (47.4%) in the group with onset time >24 hours. There was significant difference between the two groups only in the ASPECTS ( P=0.035), but there were no significant differences in the postprocedural recanalization rate, sICH incidence rate, and good outcome rate at 90 days. Conclusion:Endovascular therapy under the guidance of multimodal imaging is safe and feasible for AIS patients with END due to anterior circulation occlusion.
6.Value of serum leucine-rich-alpha-2-glycoprotein1,neopterin,and virus antibody in evaluating the condition and predicting the prognosis of viral meningitis in children
Hong ZHAO ; Yongtao MA ; Tao ZHANG ; Wei ZHU
Journal of Xinxiang Medical College 2024;41(9):884-889,894
Objective To explore the role of serum leucine-rich-alpha-2-glycoprotein1(LRG1),neopterin(NPT)and virus antibodies during the progression of viral meningitis(VM)and their value in evaluating the condition and predicting the prognosis of VM in children.Methods A total of 130 pediatric patients with VM admitted to Kaifeng Children's Hospital from August 2020 to February 2023 were selected as the observation group,and at the same time,another 130 pediatric patients with VM symptoms who were diagnosed as non central nervous system infectious diseases by lumbar puncture cerebrospinal fluid examination were selected as the control group.After admission,2 mL peripheral venous blood of children in the two groups was collected,and the levels of serum LRG1 and NPT were assessed by enzyme-linked immunosorbent assay.Before treatment,1 mL cerebrospinal fluid sample of children in the two groups was collected by lumbar puncture,and the host specific immuno-globulin G(IgG)against herpes simplex virus-I(HSV-I),cytomegalovirus(CMV),Epstein-Barr virus(EBV),and parain-fluenza virus(PIV)in cerebrospinal fluid was detected by enzyme-linked immunosorbent assay.The levels of serum LRG1 and NPT,as well as the positive rate of virus antibody IgG were compared between the two groups.The VM children were then divided into the severe group(n=54)and mild group(n=76)according to the disease severity,and they were divided into the good prognosis group(n=37)and poor prognosis group(n=93)based on the prognosis.The levels of serum IRG1 and NPT and the positive rate of virus antibody IgG were compared in children with different disease severity and prognosis.The correlation of serum LRG1,NPT and virus antibody with the disease severity or disease progression for pediatric VM was analyzed,and their interactive effects on the disease progression of children with VM were analyzed.The predictive value of serum LRG1,NPT and virus antibody for pediatric VM outcome was analyzed by the receiver operating characteristic(ROC)curve.Results The levels of serum LRG1 and NPT,as well as the positive rate of virus antibody IgG of children in the obser-vation group were significantly higher than those in the control group(P<0.05);the levels of serum LRG1 and NPT,as well as the positive rate of virus antibody IgG of children in the severe group were significantly higher than those in the mild group(P<0.05);the levels of serum LRG1 and NPT,as well as the positive rate of virus antibody IgG of children in the poor prognosis group were significantly higher than those in the good prognosis group(P<0.05).High level of serum LRG1 with high positive rate of virus antibody IgG and high level of serum NPT with high positive rate of virus antibody IgG showed positive interactions in leading to poor prognosis in children with VM odds ratio(OR)=15.238,9.684).The submultiplicative models were applied for the high levels of serum LRG1 with high positive rate of virus antibody IgG(OR=15.238)and high levels of serum NPT with high positive rate of virus antibody IgG(OR=9.684).The area under the curve(AUC)for predicting poor prognosis in children with VM after 2 weeks of treatment by serum LRG1,NPT and virus antibody IgG were 0.786,0.794 and 0.919,respectively,and the AUC for the combined prediction of the three was 0.933;the AUC of LRG1,NPT and positive rate of virus antibody IgG for predicting poor prognosis in children with VM after 2 weeks of treatment was greater than that of the three alone(P<0.05).Conclusion NPT and LRG1 may be involved in the development of VM.The levels of serum LRG1 and NPT are positively correlated with the severity and progression of VM.The levels of serum NPT and LRG1 and the positive rate of virus antibody IgG have certain value in the disease evaluation and prognosis prediction of VM,and the combination of the three has a higher predictive value for the prognosis of VM.There is a positive interaction between high LRG1 with high positive rate of virus antibody IgG,and high NPT with high positive rate of virus antibody IgG in children with VM.
7.Efficacy of joint replacement versus closed reduction and internal fixation in treatment of unstable intertrochanteric fractures combined with osteoporosis
Ruizhi ZHU ; Qiang QU ; Pengfei CUI ; Dong LIU ; Yongtao ZHANG ; Changyao WANG
Chinese Journal of Tissue Engineering Research 2024;28(12):1869-1874
BACKGROUND:Stable intertrochanteric fractures can be treated by closed reduction and internal fixation,but there is no absolute advantage for unstable intertrochanteric fractures with osteoporosis. OBJECTIVE:To investigate the efficacy of arthroplasty in the treatment of unstable intertrochanteric fractures in the elderly with osteoporosis by comparing the indexes related to closed reduction internal fixation and arthroplasty. METHODS:Clinical data of 102 elderly patients with unstable intertrochanteric fractures of the femur treated in Affiliated Hospital of Qingdao University from January 2017 to January 2020 were retrospectively analyzed.Patients were divided into two groups according to the surgical method.In the Gamma3 group,62 cases received Gamma3 internal fixation system.In the joint replacement group,40 cases received an artificial femoral head replacement or total hip replacement.Surgical information,hospitalization,hip function,and postoperative complications were compared between the two groups. RESULTS AND CONCLUSION:(1)There were statistical differences between the Gamma3 group and the joint replacement group in weight-bearing time(P<0.001),hospital stay(P<0.05),intraoperative bleeding(P<0.001),and length of surgery(P<0.001).The mean weight-bearing time and hospital stay were shorter in the joint replacement group than in the Gamma3 group.Intraoperative bleeding and duration of surgery were better in the Gamma3 group than in the joint replacement group.(2)There was no significant difference in Harris hip score,subitem centesimal hip score,and postoperative complications 12 months after surgery in both groups(P=0.526,0.788,0.228).(3)It is indicated that arthroplasty has achieved better outcomes in the treatment of elderly unstable intertrochanteric fractures combined with osteoporosis,enabling early weight bearing and functional exercise.Careful selection of the appropriate patient and prosthesis type for arthroplasty will result in greater patient benefit.
8.Experiences in construction of wound repair discipline in Zibo, Shandong Province
Yongtao SU ; Guoming GU ; Ying SUI ; Bo ZHANG ; Chunlei WANG ; Junhui ZHU ; Yibing WANG ; Ran HUO ; Xiaobing FU
Chinese Journal of Trauma 2020;36(10):872-875
The construction of wound repair discipline in China is still at the initial stage of exploration, and there is no systematic and mature experiences to learn from. The Luzhong Hospital of Beijing University established a professional committee for wound repair, opened a mobile workstation for wound repair, established a wound repair alliance and quality control center, advocated a medical-care integrated treatment model, and carried out academic exchanges and scientific research, the discipline of wound repair in Shandong Province got a rapid development and the pattern of "Zibo mode" of wound repair emerged. The authors introduce the experiences in construction of the discipline of wound repair in Zibo city, in order to provide some references for the grass-roots counterparts.
9.Short-term outcomes of modified load-sharing rip-stop repair compared with suture-bridge repair for large rotator cuff tears
Zheng WANG ; Lei ZHANG ; Jia MA ; Yan LI ; Xiaohua LIU ; Ling GUO ; Yongtao ZHU ; Qingxin HAN ; Dingyuan FAN
Chinese Journal of Surgery 2020;58(8):631-635
Objective:To examine the short-term outcomes of modified load-sharing rip-stop repair (mLSRS) and suture-bridge repair (SB) for large rotator cuff tear.Methods:The clinical data of patients who underwent shoulder arthroscopy for large rotator cuff repair at Department of Orthopedic, China Academy of Chinese Medical Sciences Wang Jing Hospital from January 2017 to December 2018 were collected. Totally 111 patients (39 in mLSRS group and 72 in SB group) were included in the study. There were 45 males and 66 females, aged (58.0±6.9)years (range: 40 to 72 years).A total of 39 pairs of patients were successfully matched by propensity score matching. The pain of shoulder joint was assessed by visual analogy score (VAS) , the shoulder function was assessed by Constant-Murley score, the abduction strength of bilateral shoulder joint was assessed by 90? force assessment method of upper limb on the plane of scapula, and the healing of rotator cuff on the operative side was assessed by sugaya ultrasonic classification standard. The difference of short-term outcome between the two groups were compared using t test, χ 2 test, Mann-Whitney U test, repeated measures design anova and multivariate analysis of variance. Results:At the 4th week after surgery, the VAS of mLSRS group was significantly lower than SB group(1 (2) vs. 2 (2) , F=5.32, P=0.02). One year after surgery, Constant-Murley score of two groups were significantly higher than those before surgery, but there was no significant difference between two groups(89.1±5.7 vs. 87.6±7.3, t=1.00, P=0.32). Abductor strength of affected limbs were lower than that of the opposite side, but there were no statistically significant differences between two groups(4.28±1.61 vs. 4.54±1.64, t=-0.70, P=0.49). According to the Sugaya classification, 32 cases in mLSRS group were healed while 7 cases were not healed,30 cases in SB group were healed while 9 cases were not healed(χ 2=0.32, P=0.58). Conclusion:The use of mLSRS fixation construct on large rotator cuff tear can reduce pain and the short-term outcome is reliable.
10.Short-term outcomes of modified load-sharing rip-stop repair compared with suture-bridge repair for large rotator cuff tears
Zheng WANG ; Lei ZHANG ; Jia MA ; Yan LI ; Xiaohua LIU ; Ling GUO ; Yongtao ZHU ; Qingxin HAN ; Dingyuan FAN
Chinese Journal of Surgery 2020;58(8):631-635
Objective:To examine the short-term outcomes of modified load-sharing rip-stop repair (mLSRS) and suture-bridge repair (SB) for large rotator cuff tear.Methods:The clinical data of patients who underwent shoulder arthroscopy for large rotator cuff repair at Department of Orthopedic, China Academy of Chinese Medical Sciences Wang Jing Hospital from January 2017 to December 2018 were collected. Totally 111 patients (39 in mLSRS group and 72 in SB group) were included in the study. There were 45 males and 66 females, aged (58.0±6.9)years (range: 40 to 72 years).A total of 39 pairs of patients were successfully matched by propensity score matching. The pain of shoulder joint was assessed by visual analogy score (VAS) , the shoulder function was assessed by Constant-Murley score, the abduction strength of bilateral shoulder joint was assessed by 90? force assessment method of upper limb on the plane of scapula, and the healing of rotator cuff on the operative side was assessed by sugaya ultrasonic classification standard. The difference of short-term outcome between the two groups were compared using t test, χ 2 test, Mann-Whitney U test, repeated measures design anova and multivariate analysis of variance. Results:At the 4th week after surgery, the VAS of mLSRS group was significantly lower than SB group(1 (2) vs. 2 (2) , F=5.32, P=0.02). One year after surgery, Constant-Murley score of two groups were significantly higher than those before surgery, but there was no significant difference between two groups(89.1±5.7 vs. 87.6±7.3, t=1.00, P=0.32). Abductor strength of affected limbs were lower than that of the opposite side, but there were no statistically significant differences between two groups(4.28±1.61 vs. 4.54±1.64, t=-0.70, P=0.49). According to the Sugaya classification, 32 cases in mLSRS group were healed while 7 cases were not healed,30 cases in SB group were healed while 9 cases were not healed(χ 2=0.32, P=0.58). Conclusion:The use of mLSRS fixation construct on large rotator cuff tear can reduce pain and the short-term outcome is reliable.

Result Analysis
Print
Save
E-mail