1.Interpretation and thoughts on the formulation and revision of the standards for exogenous harmful residues in traditional Chinese medicinal materials in the Chinese Pharmacopoeia 2025 Edition
WANG Ying ; SHEN Mingrui ; LIU Yuanxi ; ZUO Tiantian ; WANG Dandan ; HE Yi ; CHENG Xianlong ; JIN Hongyu ; LIU Yongli ; WEI Feng ; MA Shuangcheng
Drug Standards of China 2025;26(1):083-092
As people’s attention to health continues to increase, the market demand for traditional Chinese medicine (TCM) is growing steadily. The quality and safety of Chinese medicinal materials have attracted unprecedented social attention. In particular, the issue of exogenous harmful residue pollution in TCM has become a hot topic of concern for both regulatory authorities and society. The Chinese Pharmacopoeia 2025 Edition further refines the detection methods and limit standards for exogenous harmful residues in TCM. This not only reflects China’s high-level emphasis on the quality and safety of TCM but also demonstrates the continuous progress made by China in the field of TCM safety supervision. Basis on this study, by systematically reviewing the development history of the detection standards for exogenous harmful residues in TCM and analyzing the revisions and updates of these detection standards in the Chinese Pharmacopoeia 2025 Edition, deeply explores the key points of the changes in the monitoring standards for exogenous harmful residues in TCM in the Chinese Pharmacopoeia 2025 Edition. Moreover, it interprets the future development directions of the detection of exogenous residues in TCM, aiming to provide a reference for the formulation of TCM safety supervision policies.
2.Effect of GLP-1R gene polymorphism on the efficacy of Lirglutide in type 2 diabetes mellitus patients with metabolic associated fatty liver disease
Beibei WANG ; Yongli YAO ; Lingling ZHAO ; Shuqiong WANG ; Kang SONG ; Yanan LI ; Xiaoxia FAN ; Lijun LIN ; Yanling XIE ; Yanping JIANG ; Jingyuan WANG ; Ying QU ; Wei LUO
Chinese Journal of Diabetes 2025;33(6):414-418
Objective To investigate the effect of the rs3765467 polymorphism of glucagon-like peptide-1 receptor(GLP-1R)gene on the efficacy of Liraglutide(Lir)in patients with type 2 diabetes mellitus(T2DM)and metabolic associated fatty liver disease(MAFLD).Methods A total of 281 patients with T2DM from May 2022 to May 2023 were selected,including 125 patients with simple T2DM(T2DM group)and 156 patients with T2DM combined with MAFLD(T2DM+MAFLD group).120 healthy individuals during the same period were selected as the control(NC)group.The related indexes of glucose and lipid metabolism were detected.The polymorphism of GLP-1R gene rs3765467 was detected.Results BMI,FPG,HbA1c,HOMA-IR and TG in each group increased in turn(P<0.05),while the distribution frequency of genotype GG and allele G decreased in turn(P<0.05).TC and LDL-C in T2DM and T2DM+MAFLD groups were higher than those in NC group(P<0.05).TC and TG levels in genotype GA/AA patients were significantly higher than those in genotype GG patients(P<0.05).Compared with before treatment,the levels of BMI,FPG,HbA1c,HOMA-IR,TC,TG and LDL-C in T2DM patients with MAFLD were significantly decreased after Lir treatment(P<0.05).There was no significant difference in BMI and related indexes of glucose and lipid metabolism in GG and GA/AA patients before and after Lir treatment(P>0.05).Conclusions The distribution frequency of GG and G allele at rs3765467 of GLP-1R gene is reduced in T2DM patients with MAFLD.The carrying of allele A was associated with increased TC and TG levels,but did not affect the efficacy of Lir in reducing weight and improving glycolipid metabolism.
3.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
4.Prognostic analysis of double primary breast cancer and endometrial cancer patients based on SEER database
Shuyan SHI ; Xiaocan JIA ; Yongli YANG ; Na SUN ; Ying ZHANG ; Wei WANG
Chinese Journal of Oncology 2025;47(8):734-744
Objective:To investigate the survival outcomes and prognostic factors of patients with double primary breast cancer (BC) and endometrial cancer (EC).Methods:A retrospective cohort study was conducted using data for the period 1992-2018 from the Surveillance, Epidemiology, and End Results (SEER) database. There were 3 465 patients with BC as the first primary cancer (BC-EC group) and 2 804 patients with EC as the first primary cancer (EC-BC group). Kaplan-Meier analysis and cumulative incidence function were used to estimate overall mortality, breast cancer-specific mortality, and endometrial cancer-specific mortality, respectively. Cox regression and Fine-Gray regression were used to analyze the prognostic factors of overall mortality, breast cancer-specific mortality, and endometrial cancer-specific mortality, respectively.Results:During a median follow-up of 160 months, 1 616 deaths occurred in the BC-EC group, with EC being the leading cause of death (37.69%); 994 deaths occurred in the EC-BC group, with BC being the leading cause of death (28.77%). Cox regression identified patients with older ages at first primary cancer diagnosis (54-61 years: HR=1.46, 95% CI: 1.26-1.69; 62-68 years: HR=2.64, 95% CI: 2.29-3.03; ≥69 years: HR=4.89, 95% CI: 4.27-5.60), shorter time interval between the diagnoses (0-5 months: HR=6.13, 95% CI: 5.21-7.21; 6-23 months: HR=5.69, 95% CI: 4.95-6.55; 24-59 months: HR=3.44, 95% CI: 3.04-3.89; 60-119 months: HR=2.32, 95% CI: 2.07-2.59), mixed ductal-lobular BC ( HR=1.29, 95% CI: 1.11-1.48), endometrial mixed cell adenocarcinoma ( HR=1.23, 95% CI: 1.01-1.50), advanced tumor grade (grade Ⅱ BC: HR=1.13, 95% CI: 1.01-1.27; grade Ⅲ BC: HR=1.24, 95% CI: 1.10-1.41; grade Ⅱ EC: HR=1.19, 95% CI: 1.06-1.33; grade Ⅲ EC: HR=1.68, 95% CI: 1.48-1.90), advanced tumor stage of the two cancers (distant BC: HR=3.14, 95% CI: 2.50-3.94; regional EC: HR=1.53, 95% CI: 1.36-1.71; distant EC: HR=3.00, 95% CI: 2.59-3.47) had increased risk of overall mortality. Fine-Gray regression showed that compared with BC-EC patients, EC-BC patients had a higher risk of breast cancer-specific mortality [sub-distribution hazard ratio (s HR=1.24, 95% CI: 1.04-1.47], but a lower risk of endometrial cancer-specific mortality (s HR=0.37, 95% CI: 0.30-0.46). Older ages at first cancer diagnosis, shorter intervals between the diagnoses, negative ER and PR status, and advanced BC grades/stages were associated with increased breast cancer-specific mortality ( P<0.05). Similarly, older ages, shorter intervals, endometrial serous carcinoma/mixed cell adenocarcinoma, and advanced EC grades/stages correlated with elevated endometrial cancer-specific mortality ( P<0.05). Conclusion:The management of double primary BC and EC patients requires multidisciplinary strategies, with particular attention to patients presenting older ages at first cancer diagnosis, shorter intervals between the diagnoses, and unfavorable tumor characteristics.
5.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
6.Interpretation and thoughts on the formulation and revision of the standards for exogenous harmful residues in traditional Chinese medicinal materials in the Chinese Pharmacopoeia 2025 Edition
Ying WANG ; Mingrui SHEN ; Yuanxi LIU ; Tiantian ZUO ; Dandan WANG ; Yi HE ; Xianlong CHENG ; Hongyu JIN ; Yongli LIU ; Feng WEI ; Shuangcheng MA
Drug Standards of China 2025;26(1):83-92
As people's attention to health continues to increase,the market demand for traditional Chinese medi-cine(TCM)is growing steadily.The quality and safety of Chinese medicinal materials have attracted unprecedent-ed social attention.In particular,the issue of exogenous harmful residue pollution in TCM has become a hot topic of concern for both regulatory authorities and society.The Chinese Pharmacopoeia 2025 Edition further refines the detection methods and limit standards for exogenous harmful residues in TCM .This not only reflects China's high-level emphasis on the quality and safety of TCM but also demonstrates the continuous progress made by China in the field of TCM safety supervision.Basis on this study,by systematically reviewing the development history of the detection standards for exogenous harmful residues in TCM and analyzing the revisions and updates of these detec-tion standards in the Chinese Pharmacopoeia 2025 Edition,deeply explores the key points of the changes in the monitoring standards for exogenous harmful residues in TCM in the Chinese Pharmacopoeia 2025 Edition.Moreo-ver,it interprets the future development directions of the detection of exogenous residues in TCM ,aiming to provide a reference for the formulation of TCM safety supervision policies.
7.Effect of GLP-1R gene polymorphism on the efficacy of Lirglutide in type 2 diabetes mellitus patients with metabolic associated fatty liver disease
Beibei WANG ; Yongli YAO ; Lingling ZHAO ; Shuqiong WANG ; Kang SONG ; Yanan LI ; Xiaoxia FAN ; Lijun LIN ; Yanling XIE ; Yanping JIANG ; Jingyuan WANG ; Ying QU ; Wei LUO
Chinese Journal of Diabetes 2025;33(6):414-418
Objective To investigate the effect of the rs3765467 polymorphism of glucagon-like peptide-1 receptor(GLP-1R)gene on the efficacy of Liraglutide(Lir)in patients with type 2 diabetes mellitus(T2DM)and metabolic associated fatty liver disease(MAFLD).Methods A total of 281 patients with T2DM from May 2022 to May 2023 were selected,including 125 patients with simple T2DM(T2DM group)and 156 patients with T2DM combined with MAFLD(T2DM+MAFLD group).120 healthy individuals during the same period were selected as the control(NC)group.The related indexes of glucose and lipid metabolism were detected.The polymorphism of GLP-1R gene rs3765467 was detected.Results BMI,FPG,HbA1c,HOMA-IR and TG in each group increased in turn(P<0.05),while the distribution frequency of genotype GG and allele G decreased in turn(P<0.05).TC and LDL-C in T2DM and T2DM+MAFLD groups were higher than those in NC group(P<0.05).TC and TG levels in genotype GA/AA patients were significantly higher than those in genotype GG patients(P<0.05).Compared with before treatment,the levels of BMI,FPG,HbA1c,HOMA-IR,TC,TG and LDL-C in T2DM patients with MAFLD were significantly decreased after Lir treatment(P<0.05).There was no significant difference in BMI and related indexes of glucose and lipid metabolism in GG and GA/AA patients before and after Lir treatment(P>0.05).Conclusions The distribution frequency of GG and G allele at rs3765467 of GLP-1R gene is reduced in T2DM patients with MAFLD.The carrying of allele A was associated with increased TC and TG levels,but did not affect the efficacy of Lir in reducing weight and improving glycolipid metabolism.
8.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
9.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
10.Prognostic analysis of double primary breast cancer and endometrial cancer patients based on SEER database
Shuyan SHI ; Xiaocan JIA ; Yongli YANG ; Na SUN ; Ying ZHANG ; Wei WANG
Chinese Journal of Oncology 2025;47(8):734-744
Objective:To investigate the survival outcomes and prognostic factors of patients with double primary breast cancer (BC) and endometrial cancer (EC).Methods:A retrospective cohort study was conducted using data for the period 1992-2018 from the Surveillance, Epidemiology, and End Results (SEER) database. There were 3 465 patients with BC as the first primary cancer (BC-EC group) and 2 804 patients with EC as the first primary cancer (EC-BC group). Kaplan-Meier analysis and cumulative incidence function were used to estimate overall mortality, breast cancer-specific mortality, and endometrial cancer-specific mortality, respectively. Cox regression and Fine-Gray regression were used to analyze the prognostic factors of overall mortality, breast cancer-specific mortality, and endometrial cancer-specific mortality, respectively.Results:During a median follow-up of 160 months, 1 616 deaths occurred in the BC-EC group, with EC being the leading cause of death (37.69%); 994 deaths occurred in the EC-BC group, with BC being the leading cause of death (28.77%). Cox regression identified patients with older ages at first primary cancer diagnosis (54-61 years: HR=1.46, 95% CI: 1.26-1.69; 62-68 years: HR=2.64, 95% CI: 2.29-3.03; ≥69 years: HR=4.89, 95% CI: 4.27-5.60), shorter time interval between the diagnoses (0-5 months: HR=6.13, 95% CI: 5.21-7.21; 6-23 months: HR=5.69, 95% CI: 4.95-6.55; 24-59 months: HR=3.44, 95% CI: 3.04-3.89; 60-119 months: HR=2.32, 95% CI: 2.07-2.59), mixed ductal-lobular BC ( HR=1.29, 95% CI: 1.11-1.48), endometrial mixed cell adenocarcinoma ( HR=1.23, 95% CI: 1.01-1.50), advanced tumor grade (grade Ⅱ BC: HR=1.13, 95% CI: 1.01-1.27; grade Ⅲ BC: HR=1.24, 95% CI: 1.10-1.41; grade Ⅱ EC: HR=1.19, 95% CI: 1.06-1.33; grade Ⅲ EC: HR=1.68, 95% CI: 1.48-1.90), advanced tumor stage of the two cancers (distant BC: HR=3.14, 95% CI: 2.50-3.94; regional EC: HR=1.53, 95% CI: 1.36-1.71; distant EC: HR=3.00, 95% CI: 2.59-3.47) had increased risk of overall mortality. Fine-Gray regression showed that compared with BC-EC patients, EC-BC patients had a higher risk of breast cancer-specific mortality [sub-distribution hazard ratio (s HR=1.24, 95% CI: 1.04-1.47], but a lower risk of endometrial cancer-specific mortality (s HR=0.37, 95% CI: 0.30-0.46). Older ages at first cancer diagnosis, shorter intervals between the diagnoses, negative ER and PR status, and advanced BC grades/stages were associated with increased breast cancer-specific mortality ( P<0.05). Similarly, older ages, shorter intervals, endometrial serous carcinoma/mixed cell adenocarcinoma, and advanced EC grades/stages correlated with elevated endometrial cancer-specific mortality ( P<0.05). Conclusion:The management of double primary BC and EC patients requires multidisciplinary strategies, with particular attention to patients presenting older ages at first cancer diagnosis, shorter intervals between the diagnoses, and unfavorable tumor characteristics.

Result Analysis
Print
Save
E-mail