1.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
2.The Impact of Hospital Volume and Region on Mortality, Medical Costs, and Length of Hospital Stay in Elderly Patients Following Hip Fracture:A Nationwide Claims Database Analysis
Seung Hoon KIM ; Suk-Yong JANG ; Yonghan CHA ; Hajun JANG ; Bo-Yeon KIM ; Hyo-Jung LEE ; Gui-Ok KIM
Clinics in Orthopedic Surgery 2025;17(1):80-90
Background:
The purpose of our study was to analyze the effects of hospital volume and region on in-hospital and long-term mortality, direct medical costs (DMCs), and length of hospital stay (LOS) in elderly patients following hip fracture, utilizing nationwide claims data.
Methods:
This retrospective nationwide study sourced its subjects from the Korean National Health Insurance Review and Assessment Service database spanning from January 2011 to December 2018. A generalized estimating equation model with a Poisson distribution and logarithmic link function was used to estimate adjusted odds ratios (aORs) and 95% CIs to assess the association of hospital volume with in-hospital and 1-year mortality, DMCs, and LOS .
Results:
A total of 172,144 patients were included. Comparing the risk of in-hospital death between high-volume and low-volume hospitals, the risk of in-hospital death was 1.2 times higher at low-volume hospitals (aOR, 1.20; 95% CI, 1.07–1.33; p = 0.002).Additionally, the risk of death at 1 year was 1.05 times higher at low-volume hospitals (aOR, 1.05; 95% CI, 1.01–1.09; p = 0.008) compared to high-volume hospitals. DMCs were 0.84 times lower at low-volume hospitals for in-hospital period (aOR, 0.84; 95% CI, 0.84–0.85; p < 0.001) and 0.87 times lower for 1 year (aOR, 0.87; 95% CI, 0.86–0.88; p < 0.001) compared to high-volume hospitals. In-hospital LOS was 1.21 times longer at low-volume hospitals (aOR, 1.21; 95% CI, 1.20–1.22; p < 0.001) than at high-volume hospitals. In addition, the risk of in-hospital death was 1.22 times higher (aOR, 1.22; 95% CI, 1.12–1.33; p < 0.001) and the risk of 1-year death was 1.07 times higher (aOR, 1.07; 95% CI, 1.04–1.10; p < 0.001) at rural hospitals compared to urban hospitals.
Conclusions
Clinicians should focus on improving clinical outcomes for hip fracture patients in low-volume and rural hospital settings, with a specific emphasis on reducing mortality rates.
3.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
4.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
5.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
6.The Impact of Hospital Volume and Region on Mortality, Medical Costs, and Length of Hospital Stay in Elderly Patients Following Hip Fracture:A Nationwide Claims Database Analysis
Seung Hoon KIM ; Suk-Yong JANG ; Yonghan CHA ; Hajun JANG ; Bo-Yeon KIM ; Hyo-Jung LEE ; Gui-Ok KIM
Clinics in Orthopedic Surgery 2025;17(1):80-90
Background:
The purpose of our study was to analyze the effects of hospital volume and region on in-hospital and long-term mortality, direct medical costs (DMCs), and length of hospital stay (LOS) in elderly patients following hip fracture, utilizing nationwide claims data.
Methods:
This retrospective nationwide study sourced its subjects from the Korean National Health Insurance Review and Assessment Service database spanning from January 2011 to December 2018. A generalized estimating equation model with a Poisson distribution and logarithmic link function was used to estimate adjusted odds ratios (aORs) and 95% CIs to assess the association of hospital volume with in-hospital and 1-year mortality, DMCs, and LOS .
Results:
A total of 172,144 patients were included. Comparing the risk of in-hospital death between high-volume and low-volume hospitals, the risk of in-hospital death was 1.2 times higher at low-volume hospitals (aOR, 1.20; 95% CI, 1.07–1.33; p = 0.002).Additionally, the risk of death at 1 year was 1.05 times higher at low-volume hospitals (aOR, 1.05; 95% CI, 1.01–1.09; p = 0.008) compared to high-volume hospitals. DMCs were 0.84 times lower at low-volume hospitals for in-hospital period (aOR, 0.84; 95% CI, 0.84–0.85; p < 0.001) and 0.87 times lower for 1 year (aOR, 0.87; 95% CI, 0.86–0.88; p < 0.001) compared to high-volume hospitals. In-hospital LOS was 1.21 times longer at low-volume hospitals (aOR, 1.21; 95% CI, 1.20–1.22; p < 0.001) than at high-volume hospitals. In addition, the risk of in-hospital death was 1.22 times higher (aOR, 1.22; 95% CI, 1.12–1.33; p < 0.001) and the risk of 1-year death was 1.07 times higher (aOR, 1.07; 95% CI, 1.04–1.10; p < 0.001) at rural hospitals compared to urban hospitals.
Conclusions
Clinicians should focus on improving clinical outcomes for hip fracture patients in low-volume and rural hospital settings, with a specific emphasis on reducing mortality rates.
7.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
8.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
9.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
10.The Impact of Hospital Volume and Region on Mortality, Medical Costs, and Length of Hospital Stay in Elderly Patients Following Hip Fracture:A Nationwide Claims Database Analysis
Seung Hoon KIM ; Suk-Yong JANG ; Yonghan CHA ; Hajun JANG ; Bo-Yeon KIM ; Hyo-Jung LEE ; Gui-Ok KIM
Clinics in Orthopedic Surgery 2025;17(1):80-90
Background:
The purpose of our study was to analyze the effects of hospital volume and region on in-hospital and long-term mortality, direct medical costs (DMCs), and length of hospital stay (LOS) in elderly patients following hip fracture, utilizing nationwide claims data.
Methods:
This retrospective nationwide study sourced its subjects from the Korean National Health Insurance Review and Assessment Service database spanning from January 2011 to December 2018. A generalized estimating equation model with a Poisson distribution and logarithmic link function was used to estimate adjusted odds ratios (aORs) and 95% CIs to assess the association of hospital volume with in-hospital and 1-year mortality, DMCs, and LOS .
Results:
A total of 172,144 patients were included. Comparing the risk of in-hospital death between high-volume and low-volume hospitals, the risk of in-hospital death was 1.2 times higher at low-volume hospitals (aOR, 1.20; 95% CI, 1.07–1.33; p = 0.002).Additionally, the risk of death at 1 year was 1.05 times higher at low-volume hospitals (aOR, 1.05; 95% CI, 1.01–1.09; p = 0.008) compared to high-volume hospitals. DMCs were 0.84 times lower at low-volume hospitals for in-hospital period (aOR, 0.84; 95% CI, 0.84–0.85; p < 0.001) and 0.87 times lower for 1 year (aOR, 0.87; 95% CI, 0.86–0.88; p < 0.001) compared to high-volume hospitals. In-hospital LOS was 1.21 times longer at low-volume hospitals (aOR, 1.21; 95% CI, 1.20–1.22; p < 0.001) than at high-volume hospitals. In addition, the risk of in-hospital death was 1.22 times higher (aOR, 1.22; 95% CI, 1.12–1.33; p < 0.001) and the risk of 1-year death was 1.07 times higher (aOR, 1.07; 95% CI, 1.04–1.10; p < 0.001) at rural hospitals compared to urban hospitals.
Conclusions
Clinicians should focus on improving clinical outcomes for hip fracture patients in low-volume and rural hospital settings, with a specific emphasis on reducing mortality rates.

Result Analysis
Print
Save
E-mail