1.Technique and Application of Deep Learning-based EEG Denoising
Bao-Lian SHAN ; Hai-Qing YU ; Yong-Zhi HUANG ; Jia-Yuan MENG ; Min-Peng XU ; Tzyy-Ping JUNG ; Dong MING
Progress in Biochemistry and Biophysics 2026;53(8):2147-2160
Electroencephalography (EEG) is a non-invasive neurophysiological monitoring technique. It records the electrical activity of the cerebral cortex using electrodes placed on the scalp surface. Owing to its high safety, portability, and millisecond-level temporal resolution, EEG has been widely utilized in a variety of fields, including clinical diagnosis, brain-computer interfaces (BCIs), and cognitive neuroscience research. However, due to its microvolt-level amplitude, EEG is highly susceptible to various artifacts, including electrooculographic (EOG), electrocardiographic (ECG), electromyographic (EMG), and power line interference (PLI). These artifacts can obscure genuine neural activity and introduce spurious electrophysiological features. Consequently, they may compromise EEG signal quality, thereby reducing the reliability of downstream analyses. To address this issue, numerous EEG artifact removal methods have been developed, including both traditional denoising techniques and deep learning-based approaches. Traditional EEG denoising methods have long served as the primary solutions for artifact removal. Representative approaches include filtering, regression, and blind source separation. Although these methods have demonstrated effectiveness in specific scenarios, they suffer from several inherent limitations. Filtering assumes that artifacts and EEG signals can be separated in the frequency domain, but many artifacts, such as EOG and EMG, overlap with EEG spectra, which may lead to the loss of valuable neural information. Regression methods require high-quality artifact references to estimate and subtract contaminations, limiting their effectiveness in reference-free scenarios. Blind source separation can remove artifacts without external references, but it typically requires the number of EEG channels to exceed the number of sources, restricting its application in single- or low-channel EEG recordings. Deep learning-based EEG denoising methods address these limitations effectively. First, they learn the nonlinear mapping between contaminated and clean EEG directly from data in an end-to-end manner. This approach does not rely on assumptions about spectral separability, thereby preserving neural activity more completely. Second, the reference information is incorporated during the training phase, allowing the trained model to perform artifact removal independently without external references. Third, deep learning models can be flexibly designed to accommodate various recording setups, achieving robust denoising for both high-density and single-channel EEG. Collectively, these advantages enable deep learning-based methods to overcome the main challenges of traditional approaches, providing more accurate and reliable EEG signal recovery. The superior denoising performance of deep learning-based EEG denoising methods has attracted increasing attention in EEG artifact removal research. As a result, many deep learning-based denoising methods have been developed and successfully applied in neural engineering areas. However, a systematic review of the techniques and applications in this field is still lacking. To address this gap, this paper reviews recent advances in deep learning-based EEG denoising from four perspectives: technical principle, benchmark dataset, denoising model, and evaluation method. Representative applications in neural signal analysis and BCI decoding are also summarized. Furthermore, the advantage, existing challenge, and future research direction of deep learning-based EEG denoising are discussed. This review aims to provide valuable theoretical insights and technical guidance for researchers. It is also expected to promote further advances and broader applications of deep learning-based EEG denoising techniques.
2.The Dual Role and Clinical Potential of Core Fucosylation in Liver Diseases
Zi-Han LEI ; Hui-Min XU ; De-Zhi ZHAO ; Yong-Hong GUO ; Hao-Qi DU
Progress in Biochemistry and Biophysics 2026;53(8):2161-2178
Core fucosylation, catalyzed exclusively by fucosyltransferase 8 (FUT8), is an evolutionarily conserved post-translational modification that has emerged as a central regulatory hub linking liver homeostasis, chronic disease progression, and malignant transformation. Liver diseases, particularly hepatocellular carcinoma, remain a leading global health burden characterized by late diagnosis, limited therapeutic options, and poor overall survival. While aberrant glycosylation is now recognized as a hallmark of cancer and inflammatory disorders, existing research on FUT8-mediated core fucosylation in liver diseases remains fragmented: the dynamic functional switch of FUT8 from a homeostatic regulator to a pathological driver across the full disease continuum has not been systematically delineated, and the integrated mechanisms by which core fucosylation modulates oncogenic signaling, metabolic reprogramming, and immune evasion remain poorly understood. This review synthesizes recent advances to establish a unified framework for understanding the dual role of core fucosylation in liver physiology and pathology, and evaluates its translational potential for precision medicine. At the molecular level, FUT8’s unique catalytic specificity makes core fucosylation an irreplaceable modification, as evidenced by the perinatal lethality and severe organ dysfunction in Fut8 knockout mice. In hepatocellular carcinoma, genomic amplification of guanosine 5'-diphosphate-fucose biosynthetic enzymes provides metabolic support for aberrant core fucosylation. FUT8 expression is tightly regulated by a multi-layered network: transcriptional activation via Wnt/β‑catenin and wild-type p53, epigenetic upregulation by lncRNAs, post-transcriptional repression by miR-122-5p and miR-34a, and virus-specific induction by hepatitis B virus/hepatitis C virus. Physiologically, core fucosylation maintains liver homeostasis through four core mechanisms: it acts as a molecular switch for epidermal growth factor receptor/hepatocyte growth factor receptor signaling to enable liver regeneration; directs polarized secretion of hepatocyte-derived glycoproteins into bile ducts; modulates cholesterol metabolism via the hepatocyte nuclear factor 1α-proprotein convertase subtilisin/kexin type 9-low density lipoprotein receptor axis; and regulates aging through insulin‑like growth factor 1 receptor signaling. Pathologically, core fucosylation exhibits context-dependent dual functions: in liver fibrosis, FUT8 upregulation in hepatic stellate cells forms a negative feedback loop that limits excessive fibrogenesis; in hepatocellular carcinoma, however, aberrant FUT8 overexpression drives cell-autonomous malignancy by constitutively activating epidermal growth factor/hepatocyte growth factor receptor, transforming growth factor‑β/Smad, and Wnt/β‑catenin pathways, while simultaneously establishing a multi-layered immune evasion network by stabilizing programmed cell death ligand 1 and cluster of differentiation 47, and impairing natural killer cell homeostasis via interleukin‑2 receptor β glycosylation. Clinically, stage-specific core fucosylation biomarkers enable non-invasive monitoring of liver disease progression: low molecular mass kringle-Fc fusion protein outperforms conventional markers for early fibrosis detection, while alpha-fetoprotein-L3 and novel glycopeptides (α‑2‑macroglobulin N‑linked glycosylation site 1424, lumican core fucosylated peptide) significantly improve early hepatocellular carcinoma diagnosis, especially in alpha-fetoprotein-negative patients. Next-generation detection technologies (chemoenzymatic labeling, site-specific mass spectrometry) overcome the specificity limitations of traditional lectin assays. Therapeutically, four promising strategies are emerging: small-molecule FUT8 inhibitors, afucosylated antibodies with enhanced antibody‑dependent cellular cytotoxicity, Fuc-modified targeted drug delivery systems, and core fucose-specific lectins for NASH treatment. The core challenge for clinical translation lies in FUT8’s inherent “double-edged sword” effect, as systemic inhibition disrupts its essential physiological functions beyond pathological roles. Long-term systemic FUT8 blockade not only impairs post-injury liver regeneration by abrogating epidermal growth factor/hepatocyte growth factor receptor signaling but also disrupts cholesterol homeostasis via the hepatocyte nuclear factor 1α-proprotein convertase subtilisin/kexin type 9-low density lipoprotein receptor axis, leading to dyslipidemia and altered bile secretion. Critically, it compromises immune surveillance by destabilizing interleukin‑2 receptor β on natural killer cells, reducing their cytotoxic activity against malignant and virally infected cells, and impairs IgG Fc-mediated effector functions, increasing susceptibility to infections. This fundamental trade-off between therapeutic efficacy and systemic toxicity necessitates a paradigm shift from non-specific global inhibition to precision modulation of pathological core fucosylation. By addressing these critical challenges, FUT8-mediated core fucosylation has the potential to transform liver disease management from late-stage intervention to early detection and precision therapy, ultimately improving patient outcomes and reducing the global burden of liver diseases.
3.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
4.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
5.Efficacy and Safety of Blinatumomab in Adult Patients with B-Cell Acute Lymphoblastic Leukemia
Ya-Lei HU ; Yong-Feng SU ; Yang LI ; Xuan ZHENG ; An WANG ; Yi-Zhi WANG ; Lei XU ; Chun-Ji GAO ; Liang-Ding HU ; Dai-Hong LIU ; Xiao-Ning GAO
Journal of Experimental Hematology 2025;33(6):1571-1576
Objective:To evaluate the efficacy and safety of blinatumomab in adult patients with relapsed/refractory(R/R)or measurable residual disease(MRD)positive B-cell acute lymphoblastic leukemia(B-ALL)in the real world.Methods:The clinical data of 30 B-ALL patients received at least 1 course of blinatumomab therapy in the Chinese PLA General Hospital from January 1st,2021 to December 31st,2023 were retrospectively analyzed,including pre-treatment baseline clinical feature,post-treatment complete response(CR),CR with partial hematologic recovery(CRh),CR with incomplete hematologic recovery(CRi),complete MRD response rate,MRD response rate(MRD<10-4),overall survival(OS),and disease-free survival(DFS),as well as drug-related adverse reactions.Results:Among 5 patients who were not assessed 4 were MRD negative and 1 did not receive bone marrow biopsy.In the R/R B-ALL group(13 cases),11 patients achieved CR/CRh/CRi and 10 patients achieved complete MRD response.In MRD+group(12 cases),9 patients achieved overall MRD response and 7 patients achieved complete MRD response.The median follow-up time was 8.4(95%CI:6.3-10.4)months.The median OS was 15.5(95%CI:0.7-30.3)months in the R/R group,while not reached in the MRD+group.The median DFS of the two groups were not reached.Drug-related adverse reactions occurred in 22 patients,and pyrexia was the most common(13 cases).Grade ≥3 adverse reactions occurred in 15 patients,and neutropenia was the most common(9 cases).Cytokine release syndrome occurred in 6 patients,including 5 cases with grade 1 and 1 case with grade 3.No patients interrupted therapy or died due to drug-related adverse reactions.Conclusion:Blinatumomab is effective in the treatment of R/R or continuous MRD+B-ALL with acceptable adverse reactions.
6.Correlation between D-dimer, antithrombin Ⅲ levels and multiple organ dysfunction syndrome in patients with severe multiple trauma
Kang TOU ; Laifa KONG ; Zhi WANG ; Yong′an XU
Chinese Journal of Postgraduates of Medicine 2025;48(7):577-584
Objective:To explore the correlation between D-dimer (D-D), antithrombin Ⅲ (AT-Ⅲ) at admission, and multiple organ dysfunction syndrome (MODS) in patients with severe multiple trauma.Methods:A retrospective study was conducted to collect data from 80 patients with severe multiple trauma admitted to Jinhua Central Hospital from April 2021 to April 2024. According to the occurrence of MODS within 1 week of treatment, the patients were divided into an occurrence group with 25 cases and a non-occurrence group with 55 cases. The general data, plasma D-D, serum AT-Ⅲ levels and other laboratory indexes at admission were compared between the two groups. The correlation between D-D, AT-Ⅲ at admission and MODS in patients with severe multiple trauma was analyzed.Results:The injury severity rating score (ISS) in the occurrence group was higher than that in the non-occurrence group: (29.12 ± 3.84) points vs. (26.18 ± 3.12) points, the proportion of damage control surgery was lower than that in the non-occurrence group: 32.00% (8/25) vs. 65.45% (36/55), the platelet, AT-Ⅲ and albumin at admission were lower than those in the non-occurrence group: (112.28 ± 20.12) ×10 9/L vs. (123.56 ± 23.47) ×10 9/L, (133.79 ± 18.21) mg/L vs. (148.26 ± 19.57) mg/L, (35.12 ± 6.35) g/L vs. (38.47 ± 5.88) g/L, the D-D at admission was higher than that in the non-occurrence group: (11.36 ± 3.35) mg/L vs. (8.18 ± 2.83) mg/L, and there were statistical differences ( P<0.05). Multivariate Logistic regression analysis result showed that the occurrence of MODS in patients with severe multiple trauma may be related to the ISS at admission, the status of receiving damage control surgery, and the D-D, AT-Ⅲ, albumin at admission ( OR = 1.29, 0.14, 1.34, 0.95 and 0.87; P<0.05). Restrictive cubic spline analysis showed that the risk of MODS in patients with severe multiple trauma showed a non-linear dose-response relationship with D-D and AT-Ⅲ at admission ( P<0.05). When D-D at admission ≥ 9.25 mg/L, the risk of MODS increased with increasing levels, while when AT-Ⅲ at admission ≤ 143.49 mg/L, the risk of MODS increased with decreasing levels. The D-D and AT-Ⅲ at admission had a negative interactive effect on the occurrence of MODS in patients with severe multiple trauma. By drawing decision curves and column charts, it was found that D-D and AT-Ⅲ at admission, as well as other major indicators, had high predictive power for the occurrence of MODS in patients with severe multiple trauma. Conclusions:The occurrence of MODS in patients with severe multiple trauma may be related to the levels of D-D and AT-Ⅲ, and the risk of MODS increases with the increase of D-D and the decrease of AT-Ⅲ at admission. Both can effectively assist other indicators in predicting the risk of MODS in patients.
7.Design and verification of accurate measurement of human body mass in microgravity environment
Zhe ZHANG ; Weibo LIU ; Zhi XU ; Yan ZHANG ; Jianping GUO ; Yu ZHANG ; Sheng Yuan WANG ; Yong XUAN ; Yue GAO ; Mi JIANG
Space Medicine & Medical Engineering 2025;36(1):50-57
Traditional mass measurement methods are not applicable in microgravity environments,and the main challenge for in-orbit body mass measurement technology based on inertial principles is to address the random errors brought about by the weightless environment.These include additional torques due to shifts in the center of mass,nonlinear accelerations due to non-rigid human bodies,mechanical energy consumption due to organ vibrations,and random vibrations of the measurement device itself.To address the above difficulties,the project proposes a technical scheme based on the principle of linear acceleration,designs and constructs a ground-specific air-floating experimental and simulation platform,studies key data such as motion trajectory,acceleration change,and vibration frequency amplitude during the mass measurement process,and simulates the changes in the center of mass and random vibrations of the human body in a weightless environment.The project has designed an adjustable posture bracket to adapt to changes in the center of mass,enhance body restraint,and greatly reduce shaking;it has also developed an integrated four-bar linkage motion guidance mechanism,high-precision integrated photoelectric distance measurement,and modular motion constant force measurement device to ensure the accurate measurement of acceleration and constant force data.The product has undergone simulation calculations,ground human applicability tests,and in-orbit applicability verification in the space station.Ground test results show that the device achieves a body mass measurement accuracy better than 0.5%,and the dispersion is better than 0.38%;after flight mission verification and evaluation,the in-orbit body mass measurement dispersion is less than 0.4%,which is superior to the SLAMMD,a mass measurement device of the same principle on the International Space Station,and is at the forefront internationally,achieving accurate body mass measurement.
8.Electrocardiogram signal quality estimation by the similarity of heartbeat morphology and wave slope character
Yu ZHANG ; Zhi XU ; Xinming YU ; Jinzhong SONG ; Zhongping CAO ; Linghao XIONG ; Yong XUAN
Space Medicine & Medical Engineering 2025;36(3):225-229
Objective Electrocardiogram(ECG)signal quality degrades when the level of activity is high and motion artifacts are severe.Poor quality signals may result in false alarms,poor patient monitoring,imprecise measurement,and misleading diagnosis.The quantitative assessment of ECG signal quality forms the basis of automatic ECG noise reduction and heart disease diagnosis.Methods The ECG signal quality index(SQI)was obtained by statistically analyzing the heartbeat similarity and the slope character,respectively,namely rSQI and kSQI.Results Using MIT-BIH Noise Stress Test Database to test,both rSQI and kSQI decreased when the Signal Noise Ratio(SNR)decreased,which revealed the ECG signal quality.Based on the quasiperiodic property,the waveform similarity,as a beat-to-beat index,is obtained by cross correlation between two ECG cycles with high precision but heavy computation.Slope-based method dispenses with QRS detection and is very simple and real-time,but its sensitivity is lower than similarity-based method and it only get statistical data.Conclusion Both morphology similarity and slope character algorithms could provide objective estimation of ECG quality.Slope-based method is an attractive measure due to its simplicity and mathematical convenience,while similarity-based method is more accurate and robust for ECG quality assessment.
9.Application prospects of intelligent soft robots in specialized medicine
Yu ZHANG ; Zhi XU ; Yong XUAN ; Jianping GUO ; Yue GAO
Space Medicine & Medical Engineering 2025;36(5):505-512
As a comprehensive high technology,robotics has gained extensive attention from numerous researchers.Intelligent soft robots,representing a new direction in robotics research,are shining brightly in fields such as fragile objects manipulating,medical assistance,and environment exploration due to their unique advantages.In the field of specialized medicine,intelligent soft robots can adapt to the complex and extreme space working environment due to their small stiffness,strong variability and high flexibility,and have broad application prospects in specialized medicine like aerospace,navigation and diving.In this paper,the research status of intelligent soft robots is reviewed from four aspects:materials,structure,actuation modalities,modeling and simulation.Furthermore,the application of intelligent soft robots in the field of specialized medicine is summarized and prospected in this paper.
10.The value of total volume response and total mass response in the therapeutic evaluation of lung metastasis of hepatocarcinoma
Jun-cheng WAN ; Cai-hong YU ; Chang-yu LI ; Yong-jie ZHOU ; Wei ZHANG ; Jian-hua WANG ; Zhi-ping YAN ; Guo-wei YANG ; Zhuo-yang FAN ; Xu-dong QU
Fudan University Journal of Medical Sciences 2025;52(2):201-208,231
Objective To analyze the correlation between lesion volume,lesion mass,and maximum lesion diameter in the assessment of advanced hepatocarcinoma with lung metastasis,and to evaluate the application value of total volume response and total mass response of lung metastatic lesions in efficacy assessment.Methods A retrospective analysis was conducted on the CT imaging data of 20 patients clinically confirmed with hepatocarcinoma and lung metastases,followed by subsequent follow-up to monitor their survival outcomes.Volume measurement software was used to measure the volume of lesions before and after treatment.We recored lesion diameter,volume measurements and CT values,calculated the mass of the lesions.The correlation between lesion volume,mass and diameter was analyzed,as well as the correlation between the change rates of volume,mass and lesion diameter.Additionally,the total volume and total mass of all lesions were calculated.The correlation between the change rates of total volume/total mass and the change rate of pulmonary lesion diameter under the RECIST 1.1 criteria,as well as the correlation with changes in patients'tumor markers,were analyzed.Furthermore,the overall volume response and overall mass response of lesions were evaluated based on changes in total volume and total mass,and their consistencies with the RECIST 1.1 criteria for efficacy evaluation were analyzed.Finally,univariate Cox regression analysis was performed to explore the association between these variables and patient survival outcomes.Results There was strong correlation between lesion volume,mass and tumor diameter(r=0.771,0.775),between the rate of change in mass and the rate of change in lesion diameter(r=0.846),and between the rates of change in total volume/total mass and the rate of change in pulmonary lesion diameter under the RECIST 1.1 criteria(r=0.800,0.896).The correlation between the rates of change in total volume/total mass and patients'tumor markers was not statistically significant.There was moderate correlation between the rate of change in volume and the rate of change in lesion diameter(r=0.692).The evaluation results of total volume response and total mass response for pulmonary lesions in advanced hepatocarcinoma with lung metastasis were generally consistent with the RECIST 1.1 criteria(Kappa=0.486,0.426).Univariate Cox regression analysis revealed that total lesion volume(P=0.047)and total lesion mass(P=0.049)were independent prognostic factors for survival outcomes.Conclusion Lesion volume,mass,and diameter,as well as their respective change rates,were found to be interrelated.Furthermore,total lesion volume and total lesion mass were identified as independent prognostic factors for survival outcomes.The total volume response and total mass response are promising evaluation methods in evaluating the efficacy of lung metastasis of hepatocarcinoma,which are different from the RECIST 1.1 evaluation criteria.

Result Analysis
Print
Save
E-mail