1.Early results and indications of Stand-alone oblique lateral interbody fusion in lumbar lesions.
Zhong-You ZENG ; Xing ZHAO ; Wei YU ; Yong-Xing SONG ; Shun-Wu FAN ; Xiang-Qian FANG ; Fei PEI ; Shi-Yang FAN ; Guo-Hao SONG
China Journal of Orthopaedics and Traumatology 2025;38(5):454-464
OBJECTIVE:
To summarize the early clinical results and safety of Stand-alone OLIF application of lumbar lesions, and explored its surgical indications.
METHODS:
Total of 92 cases of lumbar spine lesions treated with Stand-alone OLIF at two medical centers from October 2014 to December 2018 were retrospectively analyzed, including 30 males and 62 females with an average age of (61.20±12.94) years old ranged from 32 to 83 years old. There were 20 cases of lumbar spinal stenosis, 15 cases of lumbar disc degeneration, 11 cases of lumbar degenerative spondylolisthesis, 6 cases of discogenic low back pain, 7 cases of giant lumbar disc herniation, 13 cases of primary lumbar discitis, 6 cases of adjacent vertebral disease after lumbar internal fixation surgery, and 14 cases of degenerative lumbar scoliosis. Pre-operative dual energy X-ray bone density examination 31 cases' T-values ranged from -1 to -2.4, 8 cases' T-values ranged from -2.5 to -3.5, and the rest had normal bone density. The number of fusion segments: 68 cases of single segment, 9 cases of two segment, 12 cases of three segment , and 3 cases of four segment. Fusion site:L1,2 1 case, L2,3 4 cases, L3,4 10 cases, L4,5 53 cases, L2,3-L3,4 3 cases, L3,4-L4,5 6 cases, L1,2L2,3L3,4 1 case, L1,2L3,4L4,5 1 case, L2,3L3,4L4,5 10 cases, L1,2L2,3L3,4L4,5 3 cases. The clinical results and imaging results of this group of cases were observed, as well as the complications.
RESULTS:
The surgical time ranged from 40 to 140 minutes with an average of (60.92±27.40) minutes. The intraoperative bleeding volume was 20 to 720 ml with an average of (68.22±141.60) ml. The patients had a follow-up period of 6 to 84 months with an average of (38.50±12.75) months. The height of the intervertebral space recovered from (9.23±1.94) mm in preoperative to (12.68±2.01) mm in postoperative, and (9.11±1.72) mm at the last follow-up, there was a statistically significant difference(F=6.641, P=0.008);there was also a statistically significant difference between the postoperative and preoperative height of the intervertebral space(t=9.27, P<0.000 1);and there was also a statistically significant difference (t=10.06, P<0.000 1) between the last follow-up and postoperative height of the intervertebral space. At the last follow-up, cage subsidence grading was as follows:level 0 in 69 cases (76 segments), levelⅠin 17 cases (43 segments), level Ⅱin 5 cases (14 segments), and level Ⅲ in 1 case (1 segment);according to the number of segments, normal subsidence accounts for 56.72%, abnormal subsidence accounts for 43.28%. Bone mineral desity of normal subsidence groups was -0.50±0.07 whinch was better than that the abnormal subsidence groups -2.10±0.43, and the difference was statistically significant(χ2=2.275, P=0.014). As well as there was a statistically significant difference in the patient's VAS of backache from (6.28±2.11) in preoperative to (1.48±0.59) in last follow-up(t=8.56, P<0.05). The ODI recovered from (36.30±7.52)% before surgery to (10.20±2.50)% at the last follow-up, with a statistically significant difference (t=7.79, P<0.000 1). Complications involved 4 cases of intraoperative vascular injury, 21 cases of endplate injury, and 4 cases of combined vertebral fractures. The incision skin has no necrosis or infection. There were 4 cases of left sympathetic chain injury, 4 cases of transient left hip flexion weakness, 2 cases of left thigh anterolateral numbness with quadriceps femoris weakness, and 1 case of incomplete intestinal obstruction;8 cases were treated with posterior pedicle screw fixation due to fusion cage settlement accompanied by stubborn lower back pain, and 6 cases were treated with fusion cage settlement and lateral displacement. According to the actual number of cases, there were 38 complications, with an incidence rate of 41.3%.
CONCLUSION
The application of Stand alone OLIF in lumbar spine disease fusion has achieved good early results, with obvious clinical advantages, but also there are high probability of complications. It is recommended to choose carefully. It is necessary to continuously summarize and gradually clarify and complete the surgical indications and specific case selection criteria.
Humans
;
Male
;
Female
;
Middle Aged
;
Spinal Fusion/methods*
;
Lumbar Vertebrae/injuries*
;
Aged
;
Adult
;
Retrospective Studies
;
Aged, 80 and over
2.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
3.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]
4.CatLet(Hexu)angiographic scoring system
Xue-cheng SONG ; Yang HE ; Xing-hong LIN ; Cai-yun SONG ; Xiu WANG ; Ming-xing XU ; Yong-ming HE
Chinese Journal of Interventional Cardiology 2025;33(4):231-235
This review has introduced the Coronary Artery Tree description and Lesion EvaluaTion(CatLet or Hexu)angiographic scoring system,which,based solely on coronary angiography results,has characterized 6 types of right coronary artery,3 types of left descending artery,and 3 types of diagonal size,together resulting in 54 types of coronary circulation pattern.This novel angiographic scoring system can be utilized to account for coronary anatomy in its diversity,severity and complexity of diseased coronary arteries,and their subtended myocardial territories in jeopardy.The CatLet angiographic scoring system is unique in that the importance of a coronary artery is weighted according to its subtended myocardial segments,by which the variability of coronary artery has been accounted for and measured.Researchers at home and abroad have increasingly paid attention to its clinical utilities,which warrant further validation in the context of large sample size,prospective,and randomized controlled trials.The CatLet angiographic scoring system is accessible at www.catletscore.com.
5.CatLet(Hexu)angiographic scoring system
Xue-cheng SONG ; Yang HE ; Xing-hong LIN ; Cai-yun SONG ; Xiu WANG ; Ming-xing XU ; Yong-ming HE
Chinese Journal of Interventional Cardiology 2025;33(4):231-235
This review has introduced the Coronary Artery Tree description and Lesion EvaluaTion(CatLet or Hexu)angiographic scoring system,which,based solely on coronary angiography results,has characterized 6 types of right coronary artery,3 types of left descending artery,and 3 types of diagonal size,together resulting in 54 types of coronary circulation pattern.This novel angiographic scoring system can be utilized to account for coronary anatomy in its diversity,severity and complexity of diseased coronary arteries,and their subtended myocardial territories in jeopardy.The CatLet angiographic scoring system is unique in that the importance of a coronary artery is weighted according to its subtended myocardial segments,by which the variability of coronary artery has been accounted for and measured.Researchers at home and abroad have increasingly paid attention to its clinical utilities,which warrant further validation in the context of large sample size,prospective,and randomized controlled trials.The CatLet angiographic scoring system is accessible at www.catletscore.com.
6.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]
7.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
8.Characteristics and treatment measures of cages displacement after oblique lateral interbody fusion.
Zhong-You ZENG ; Xing ZHAO ; Deng-Wei HE ; Yu ZHANG ; Ping-Quan CHEN ; Hong-Fei WU ; Wei YU ; Yong-Xing SONG ; Shun-Wu FAN ; Fei PEI ; Shi-Yang FAN ; Guo-Hao SONG ; Hai-Feng WANG
China Journal of Orthopaedics and Traumatology 2024;37(12):1164-1172
OBJECTIVE:
To explore characteristics, management strategies and preventive measures of fusion device displacement after oblique lateral interbody fusion (OLIF) in treating lumbar lesions.
METHODS:
The clinical data of 12 patients with fusion device displacement after OLIF for lumbar lesions in 4 medical centers from October 2014 to December 2018 were retrospectively analyzed, including 4 males and 8 females, aged from 53 to 81 years old;2 patients with lumbar disc degeneration, 4 patients with lumbar spinal stenosis, 3 patients with lumbar degenerative spondylolisthesis and 3 patients with lumbar degenerative kyphosis;preoperative dual-energy X-ray bone mineral density (BMD) was detected in 1 patient with T-value > -1 SD, 5 patients with T-value >-1~-2.5 SD, and 6 patients with T-value <-2.5 SD;9 patients with single-segment fusion, 1 patient with 2-segment fusion, and 2 patients with 3-segment fusion;standalone OLIF was performed in 9 patients and OLIF combined with posterior pedicle screws in 3 patients. Visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate low back pain and lumbar function recovery at the time of fusion graft displacement and at the latest follow-up, respectively. In addition, according to imaging results during follow-up, the fusion device subsidence or redisplacement, loosening or fracture of internal fixation, and interbody fusion were observed, and the changes in the height of interbody space on the segment with fusion device displacement were measured and compared.
RESULTS:
There were no necrosis or infection in skin incision of 10 patients after reoperation, and 12 patients were followed up for 12 to 48 months. VAS for low back pain decreased from 3 to 8 points at the time of fusion device displacement to 0 to 2 points at the latest follow-up. ODI recovered from 31% to 51% at the time of fusion transfer to 5% to 13% at the latest follow-up. There was no loosening or fracture of the pedicle screw system during follow-up. All 11 patients with bone grafting with fusion apparatus had fusion apparatus subsidence and no further displacement of fusion apparatus. The vertebral space height recovered from 9.0 to 12.7 mm at the time of fusion graft displacement to 8.0 to 11.8 mm at the latest follow-up. Interbody fusion was obtained in all patients except 1 with no imaging results at the latest follow-up.
CONCLUSION
OLIF could be used for fusion of lumbar lesions, and there is a risk of fusion organ displacement after operation, especially in cases of bone loss or osteoporosis before surgery, end-plate injury during surgery, and Stand-alone mode, and most of them occur within 3 months after operation. Surgery is required for the transposition of the fusion apparatus in the Stand-alone OLIF mode during the primary operation. Although good clinical results could be obtained by timely detection and accurate treatment, it is still necessary to emphasize the precise selection of cases before operation, the appropriate application of OLIF, and precise operation during operation to prevent displacement of fusion device.
Humans
;
Spinal Fusion/instrumentation*
;
Female
;
Male
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Lumbar Vertebrae/surgery*
;
Retrospective Studies
;
Pedicle Screws
9.A case of pelvic arteriovenous malformation
Zhannan SI ; Gang SONG ; Yong ZHANG ; Nianzeng XING
Chinese Journal of Urology 2024;45(9):716-717
Pelvic arteriovenous malformation (pAVM) is rare. Generally the internal circulatory connections of pAVM are complex and the diagnosis is usually established by angiography showing the main blood supplying arteries and other blood supplying arteries. In this article, we reported a case of a pelvic mass. The patient was admitted to the hospital because of a pelvic mass was found for 4 years. A definitive diagnosis cannot be made based on preoperative imaging results. and a robot-assisted laparoscopic pelvic mass resection was performed. Postoperative pathology revealed a completely occlusive arteriovenous malformation. There was no recurrence or metastasis during 10 months of follow-up.
10.Reasons and strategies of reoperation after oblique lateral interbody fusion
Zhong-You ZENG ; Deng-Wei HE ; Wen-Fei NI ; Ping-Quan CHEN ; Wei YU ; Yong-Xing SONG ; Hong-Fei WU ; Shi-Yang FAN ; Guo-Hao SONG ; Hai-Feng WANG ; Fei PEI
China Journal of Orthopaedics and Traumatology 2024;37(8):756-764
Objective To summarize the reasons and management strategies of reoperation after oblique lateral interbody fusion(OLIF),and put forward preventive measures.Methods From October 2015 to December 2019,23 patients who under-went reoperation after OLIF in four spine surgery centers were retrospectively analyzed.There were 9 males and 14 females with an average age of(61.89±8.80)years old ranging from 44 to 81 years old.The index diagnosis was degenerative lumbar intervertebral dics diseases in 3 cases,discogenie low back pain in 1 case,degenerative lumbar spondylolisthesis in 6 cases,lumbar spinal stenosis in 9 cases and degenerative lumbar spinal kyphoscoliosis in 4 cases.Sixteen patients were primarily treated with Stand-alone OLIF procedures and 7 cases were primarily treated with OLIF combined with posterior pedicle screw fixation.There were 17 cases of single fusion segment,2 of 2 fusion segments,4 of 3 fusion segments.All the cases underwent reoperation within 3 months after the initial surgery.The strategies of reoperation included supplementary posterior pedicle screw instrumentation in 16 cases;posterior laminectomy,cage adjustment and neurolysis in 2 cases,arthroplasty and neuroly-sis under endoscope in 1 case,posterior laminectomy and neurolysis in 1 case,pedicle screw adjustment in 1 case,exploration and decompression under percutaneous endoscopic in 1 case,interbody fusion cage and pedicle screw revision in 1 case.Visu-al analogue scale(VAS)and Oswestry disability index(ODI)index were used to evaluate and compare the recovery of low back pain and lumbar function before reoperation and at the last follow-up.During the follow-up process,the phenomenon of fusion cage settlement or re-displacement,as well as the condition of intervertebral fusion,were observed.The changes in in-tervertebral space height before the first operation,after the first operation,before the second operation,3 to 5 days after the second operation,6 months after the second operation,and at the latest follow-up were measured and compared.Results There was no skin necrosis and infection.All patients were followed up from 12 to 48 months with an average of(28.1±7.3)months.Nerve root injury symptoms were relieved within 3 to 6 months.No cage transverse shifting and no dislodgement,loosening or breakage of the instrumentation was observed in any patient during the follow-up period.Though the intervertebral disc height was obviously increased at the first postoperative,there was a rapid loss in the early stage,and still partially lost after reopera-tion.The VAS for back pain recovered from(6.20±1.69)points preoperatively to(1.60±0.71)points postoperatively(P<0.05).The ODI recovered from(40.60±7.01)%preoperatively to(9.14±2.66)%postoperatively(P<0.05).Conclusion There is a risk of reoperation due to failure after OLIF surgery.The reasons for reoperation include preoperative bone loss or osteoporosis the initial surgery was performed by Stand-alone,intraoperative endplate injury,significant subsidence of the fusion cage after surgery,postoperative fusion cage displacement,nerve damage,etc.As long as it is discovered in a timely manner and handled properly,further surgery after OLIF surgery can achieve better clinical results,but prevention still needs to be strengthened.

Result Analysis
Print
Save
E-mail