1.Clinical Effect and Imaging Evaluation of Tendon-Management and Patella-Movement Therapeutic Manipulation for Patellofemoral Arthritis:A Randomised Controlled Trial
Jinguang GU ; Guangcheng WEI ; Yong ZHAO ; Yongli DONG ; Zechuan ZHUO ; Aolin SUN ; Weikai QIN
Journal of Traditional Chinese Medicine 2025;66(13):1350-1356
ObjectiveTo evaluate the therapeutic effect and mechanism of tendon-management and patella-movement therapeutic manipulation in the treatment of patellofemoral arthritis based on imaging evaluation. MethodsTotally 126 patients with patellofemoral arthritis were recruited and divided into a treatment group and a control group according to a randomised numerical table. The control group received routine sodium hyaluronate injection once a week for a total of 5 times; the treatment group received tendon-management and patella-movement therapeutic manipulation three times a week for four weeks. We compared the Western Ontario and McMaster University osteoarthritis index score (WOMAC), visual analogue scale (VAS), imaging indicators including patellar external displacement distance, patellofemoral fit angle, lateral patellofemoral angle, and patellofemoral index, and overall effectiveness evaluation between the two groups before and one week after treatment. ResultsThe total effective rate of the treatment group (45/54, 83.33%) was significantly higher than that of the control group (36/54, 66.67%,P<0.05). One week after the end of treatment, the VAS scores and WOMAC scores of both groups were lower than those before treatment in the same group (P<0.01), and the patellofemoral index and patellofemoral fit angle of the treatment group decreased compared with that of the control group (P<0.05). Compared with the pre-treatment, the distance of patellar external displacement, patellofemoral index, and patellofemoral fit angle decreased in the treatment group 1 week after the end of treatment, and the patellofemoral fit angle decreased in the control group (P<0.05). ConclusionThe therapeutic manipulation of tendon-management and patella-movement can correct the degree of patellar external displacement, alleviate joint pain symptoms, improve joint function, and achieve the goal of treating patellofemoral arthritis.
2.Associations between statins and all-cause mortality and cardiovascular events among peritoneal dialysis patients: A multi-center large-scale cohort study.
Shuang GAO ; Lei NAN ; Xinqiu LI ; Shaomei LI ; Huaying PEI ; Jinghong ZHAO ; Ying ZHANG ; Zibo XIONG ; Yumei LIAO ; Ying LI ; Qiongzhen LIN ; Wenbo HU ; Yulin LI ; Liping DUAN ; Zhaoxia ZHENG ; Gang FU ; Shanshan GUO ; Beiru ZHANG ; Rui YU ; Fuyun SUN ; Xiaoying MA ; Li HAO ; Guiling LIU ; Zhanzheng ZHAO ; Jing XIAO ; Yulan SHEN ; Yong ZHANG ; Xuanyi DU ; Tianrong JI ; Yingli YUE ; Shanshan CHEN ; Zhigang MA ; Yingping LI ; Li ZUO ; Huiping ZHAO ; Xianchao ZHANG ; Xuejian WANG ; Yirong LIU ; Xinying GAO ; Xiaoli CHEN ; Hongyi LI ; Shutong DU ; Cui ZHAO ; Zhonggao XU ; Li ZHANG ; Hongyu CHEN ; Li LI ; Lihua WANG ; Yan YAN ; Yingchun MA ; Yuanyuan WEI ; Jingwei ZHOU ; Yan LI ; Caili WANG ; Jie DONG
Chinese Medical Journal 2025;138(21):2856-2858
3.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
4.Comparison of side-opening and front-opening approach bone cement injectors in percutaneous kyphoplasty for thoracolumbar osteoporotic vertebral compression fractures.
Wei-Xin DONG ; Zhen-Tao CHU ; Yong HU ; Ou-Jie LAI ; Zhen-Shan YUAN ; Xiao-Yang SUN
China Journal of Orthopaedics and Traumatology 2025;38(2):128-133
OBJECTIVE:
To compare clinical efficacy between side-opening and front-opening bone cement injectors in percutaneous kyphoplasty(PKP) for the management of thoracolumbar osteoporotic vertebral compression fractures(OVCFs).
METHODS:
A retrospective cohort study was conducted, comprising 62 patients with single-segment thoracolumbar OVCFs (T11-L2), who underwent bilateral PKP at our department during the period from June 2020 to October 2021. Patients were categorized into two groups based on the specific bone cement injector employed during the surgical procedure: the side-opening group (n=29) and the front-opening group (n=33). Among them, the side-opening group consisted of 6 male and 23 female patients, with a mean age of (73.32±9.11) years. The front-opening group included 7 male and 26 female patients, with a mean age of (71.29±10.39) years. The variables encompassed essential patient characteristics were recorded, such as gender, age, bone mineral density (BMD), and fracture level (T11-L2), as well as procedural aspects, including operation duration, cement injection volume, cement distribution type (lobular or diffuse), occurrence of cement leakage, pre-and post-operative visual analogue scale (VAS) pain scores, and vertebral compression ratio.
RESULTS:
All patients underwent successful surgery, with a mean follow-up duration of (15.37±3.03) months. There were no statistically significant differences in gender, age, BMD, fracture level, preoperative vertebral compression degree, and VAS scores between the side-opening group and the front-opening group (P>0.05). The operation time, the mean cement injection volumes, the distribution of bone cement within the vertebrae has no statistically significant difference between two groups(P>0.05). Both the side-opening and front-opening groups showed significant improvements in VAS scores at 3 days and 6 months after operation (P<0.05). However, there was no significant difference in VAS scores between the two groups at both 3 days and 6 months after the operation (P>0.05).
CONCLUSION
Side-opening bone cement injectors in bilateral PKP surgery for single-segment thoracolumbar OVCF achieve similar clinical efficacy as front-opening injectors, without significant improvement in cement distribution and containment.
Humans
;
Female
;
Male
;
Kyphoplasty/instrumentation*
;
Aged
;
Bone Cements
;
Fractures, Compression/surgery*
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Thoracic Vertebrae/injuries*
;
Lumbar Vertebrae/injuries*
;
Osteoporotic Fractures/surgery*
;
Middle Aged
;
Aged, 80 and over
5.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
6.Analysis of Positive Results of Anti-M Unexpected Antibody in Pediatric Inpatients in Central China.
Dong-Dong TIAN ; Ding ZHAO ; Wei LI ; Yong-Jun WANG ; Hong-Bing HU ; Yuan-Qing YANG ; Zheng-Feng LI
Journal of Experimental Hematology 2025;33(4):1155-1160
OBJECTIVE:
To analyze the positive rate and distribution of anti-M unexpected antibody in pediatric inpatients aged 0 to 14 years in central China.
METHODS:
A total of 30 049 pediatric inpatients admitted to the Second Xiangya Hospital of Central South University, Wuhan Children's Hospital and Children's Hospital Affiliated of Zhengzhou University from May 2020 to August 2022 were enrolled in this study, and relevant clinical data were collected. Blood samples from the patients were tested for blood typing and screened for unexpected antibodies. For samples that screened positive for unexpected antibodies, identification was conducted using the identification panel to determine the specificity of the antibodies. The distribution and differences of anti-M antibodies in pediatric patients of different sexes, ages, blood groups, disease types, with or without a history of blood transfusion, and across different regions were analyzed.
RESULTS:
Among 30 049 inpatients, the positive rate of unexpected antibodies was 0.91% (273/30 049), of which the positive rate of anti-M antibodies was 0.44% (131/30 049). The positive rate of anti-M antibodies in the neonates aged 0 to < 1 month was 0.10% (5/4 881), and all of them were IgG antibodies from their mothers; The positive rate of anti-M antibodies for the group aged from 1 month to < 1 year old was 0.23% (7/3 108), with no anti-M antibodies detected in patients aged 1-6 months; The positive rates of anti-M antibodies in the 1-4 years old group, 5-9 years old group, and 10-14 years old group were 0.87% (88/10 064), 0.38% (27/7 190), and 0.08% (4/4 806), respectively. The positive rate of anti-M antibodies in the 1-4 years old group was significantly higher than that of the other groups ( P <0.001), and there were also statistical differences in the positive rate between the 5-9 years old group and the 0-< 1 month and 10-14 years old groups ( P <0.001). The prevalences of anti-M antibodies in ABO blood group A, B, O and AB were 0.32% (30/9 482), 0.70% (58/8 293), 0.32% (31/9 595) and 0.45% (12/2 679), respectively. The prevalence of anti-M antibodies in patients with blood group B was significantly higher than that in patients with blood groups A and O ( P <0.05). The prevalences of anti-M antibodies in Hunan, Hubei and Henan was 0.18%, 0.32% and 0.71%, respectively. The prevalence of anti-M antibodies in Henan was significantly higher than that in Hunan and Hubei ( P <0.05), and the distribution showed obvious regional differences between the north and the south. There were no significant differences in the positive rate of anti-M antibodies between the children with different sexes, disease types, and with or without a history of blood transfusion (P >0.05).
CONCLUSION
This study reveals the distribution pattern of anti-M antibodies in pediatric inpatients aged 0-14 years in central China, which has reference value for the research on unexpected red blood cell antibodies in Chinese children.
Humans
;
Child
;
China
;
Infant
;
Child, Preschool
;
Adolescent
;
Female
;
Male
;
Inpatients
;
Infant, Newborn
;
Blood Grouping and Crossmatching
;
Antibodies/blood*
7.Plasma club cell secretory protein reflects early lung injury: comprehensive epidemiological evidence.
Jiajun WEI ; Jinyu WU ; Hongyue KONG ; Liuquan JIANG ; Yong WANG ; Ying GUO ; Quan FENG ; Jisheng NIE ; Yiwei SHI ; Xinri ZHANG ; Xiaomei KONG ; Xiao YU ; Gaisheng LIU ; Fan YANG ; Jun DONG ; Jin YANG
Environmental Health and Preventive Medicine 2025;30():26-26
BACKGROUND:
It is inaccurate to reflect the level of dust exposure through working years. Furthermore, identifying a predictive indicator for lung function decline is significant for coal miners. The study aimed to explored whether club cell secretory protein (CC16) levels can reflect early lung function changes.
METHODS:
The cumulative respiratory dust exposure (CDE) levels of 1,461 coal miners were retrospectively assessed by constructed a job-exposure matrix to replace working years. Important factors affecting lung function and CC16 were selected by establishing random forest models. Subsequently, the potential of CC16 to reflect lung injury was explored from multiple perspectives. First, restricted cubic spline (RCS) models were used to compare the trends of changes in lung function indicators and plasma CC16 levels after dust exposure. Then mediating analysis was performed to investigate the role of CC16 in the association between dust exposure and lung function decline. Finally, the association between baseline CC16 levels and follow-up lung function was explored.
RESULTS:
The median CDE were 35.13 mg/m3-years. RCS models revealed a rapid decline in forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and their percentages of predicted values when CDE exceeded 25 mg/m3-years. The dust exposure level (<5 mg/m3-years) causing significant changes in CC16 was much lower than the level (25 mg/m3-years) that caused changes in lung function indicators. CC16 mediated 11.1% to 26.0% of dust-related lung function decline. Additionally, workers with low baseline CC16 levels experienced greater reductions in lung function in the future.
CONCLUSIONS
CC16 levels are more sensitive than lung indicators in reflecting early lung function injury and plays mediating role in lung function decline induced by dust exposure. Low baseline CC16 levels predict poor future lung function.
Uteroglobin/blood*
;
Humans
;
Dust/analysis*
;
Occupational Exposure/analysis*
;
Male
;
Middle Aged
;
Adult
;
Retrospective Studies
;
Lung Injury/chemically induced*
;
Coal Mining
;
Biomarkers/blood*
;
China/epidemiology*
;
Air Pollutants, Occupational
;
Female
8.Performance assessment of computed tomographic angiography fractional flow reserve using deep learning: SMART trial summary.
Wei ZHANG ; You-Bing YIN ; Zhi-Qiang WANG ; Ying-Xin ZHAO ; Dong-Mei SHI ; Yong-He GUO ; Zhi-Ming ZHOU ; Zhi-Jian WANG ; Shi-Wei YANG ; De-An JIA ; Li-Xia YANG ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(9):793-801
BACKGROUND:
Non-invasive computed tomography angiography (CTA)-based fractional flow reserve (CT-FFR) could become a gatekeeper to invasive coronary angiography. Deep learning (DL)-based CT-FFR has shown promise when compared to invasive FFR. To evaluate the performance of a DL-based CT-FFR technique, DeepVessel FFR (DVFFR).
METHODS:
This retrospective study was designed for iScheMia Assessment based on a Retrospective, single-center Trial of CT-FFR (SMART). Patients suspected of stable coronary artery disease (CAD) and undergoing both CTA and invasive FFR examinations were consecutively selected from the Beijing Anzhen Hospital between January 1, 2016 to December 30, 2018. FFR obtained during invasive coronary angiography was used as the reference standard. DVFFR was calculated blindly using a DL-based CT-FFR approach that utilized the complete tree structure of the coronary arteries.
RESULTS:
Three hundred and thirty nine patients (60.5 ±10.0 years and 209 men) and 414 vessels with direct invasive FFR were included in the analysis. At per-vessel level, sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of DVFFR were 94.7%, 88.6%, 90.8%, 82.7%, and 96.7%, respectively. The area under the receiver operating characteristics curve (AUC) was 0.95 for DVFFR and 0.56 for CTA-based assessment with a significant difference (P < 0.0001). At patient level, sensitivity, specificity, accuracy, PPV and NPV of DVFFR were 93.8%, 88.0%, 90.3%, 83.0%, and 95.8%, respectively. The computation for DVFFR was fast with the average time of 22.5 ± 1.9 s.
CONCLUSIONS
The results demonstrate that DVFFR was able to evaluate lesion hemodynamic significance accurately and effectively with improved diagnostic performance over CTA alone. Coronary artery disease (CAD) is a critical disease in which coronary artery luminal narrowing may result in myocardial ischemia. Early and effective assessment of myocardial ischemia is essential for optimal treatment planning so as to improve the quality of life and reduce medical costs.
9.Buccal Acupuncture Alleviates Postoperative Pain in Patients Undergoing Radical Resection of Gastrointestinal Cancers: A Randomized Controlled Pilot Study.
Zhi-Xin ZHU ; Chen CHEN ; Yong-Feng ZHENG ; Wei-Li GONG ; Zheng CHEN ; Shi-Lei FANG ; Dong-Hua SHAO ; Cai-Xia SUN
Chinese journal of integrative medicine 2025;31(6):558-565
OBJECTIVE:
To preliminarily investigate the effect of buccal acupuncture therapy on ameliorating postoperative pain and enhancing recovery quality among patients undergoing radical resection of gastrointestinal cancers.
METHODS:
Fifty-two participants were randomized at a 1:1 ratio to either the buccal acupuncture or the control group. The acupuncture protocol entailed targeting 5 predetermined acupoints [CA-2 (Upper jiao), CA-3 (Middle jiao), CA-4 (Lower jiao), CA-6 (back), and CA-7 (waist) and two adjustable acupoints [CA-1 (head) and CA-8 (sacrum)] on each side of the face. The outcomes included the Numeric Rating Scale (NRS) scores for each day within 7 days postoperatively, 15-Item Quality of Recovery Scale (QoR-15) scores, analgesics consumption during and after surgery, incidences of postoperative nausea and vomiting, and perioperative levels of interleukin-6 and glucose. Adverse events related to acupuncture were recorded.
RESULTS:
Of the initial 52 participants, 46 completed the study and were included in the analysis. Findings indicated that the buccal acupuncture group experienced significantly reduced resting NRS scores in post-anesthesia care unit and throughout the postoperative phase (P=0.001 and P=0.003, respectively), along with enhanced QoR-15 scores on the 3rd postoperative day (P=0.008), compared to the control group. No notable differences were identified in the remaining indicators (P>0.05).
CONCLUSION
Buccal acupuncture therapy demonstrated significant effectiveness in reducing postoperative pain and improving recovery quality for patients undergoing radical resection of gastrointestinal cancers, presenting a viable intervention without associated adverse outcomes. (Trial registration No. ChiCTR2200060441).
Humans
;
Male
;
Pilot Projects
;
Female
;
Acupuncture Therapy/methods*
;
Pain, Postoperative/therapy*
;
Middle Aged
;
Gastrointestinal Neoplasms/surgery*
;
Aged
;
Acupuncture Points
;
Adult
10.Shexiang Tongxin Dropping Pill Improves Stable Angina Patients with Phlegm-Heat and Blood-Stasis Syndrome: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial.
Ying-Qiang ZHAO ; Yong-Fa XING ; Ke-Yong ZOU ; Wei-Dong JIANG ; Ting-Hai DU ; Bo CHEN ; Bao-Ping YANG ; Bai-Ming QU ; Li-Yue WANG ; Gui-Hong GONG ; Yan-Ling SUN ; Li-Qi WANG ; Gao-Feng ZHOU ; Yu-Gang DONG ; Min CHEN ; Xue-Juan ZHANG ; Tian-Lun YANG ; Min-Zhou ZHANG ; Ming-Jun ZHAO ; Yue DENG ; Chang-Jiang XIAO ; Lin WANG ; Bao-He WANG
Chinese journal of integrative medicine 2025;31(8):685-693
OBJECTIVE:
To evaluate the efficacy and safety of Shexiang Tongxin Dropping Pill (STDP) in treating stable angina patients with phlegm-heat and blood-stasis syndrome by exercise duration and metabolic equivalents.
METHODS:
This multicenter, randomized, double-blind, placebo-controlled clinical trial enrolled stable angina patients with phlegm-heat and blood-stasis syndrome from 22 hospitals. They were randomized 1:1 to STDP (35 mg/pill, 6 pills per day) or placebo for 56 days. The primary outcome was the exercise duration and metabolic equivalents (METs) assessed by the standard Bruce exercise treadmill test after 56 days of treatment. The secondary outcomes included the total angina symptom score, Chinese medicine (CM) symptom scores, Seattle Angina Questionnaire (SAQ) scores, changes in ST-T on electrocardiogram and adverse events (AEs).
RESULTS:
This trial enrolled 309 patients, including 155 and 154 in the STDP and placebo groups, respectively. STDP significantly prolonged exercise duration with an increase of 51.0 s, compared to a decrease of 12.0 s with placebo (change rate: -11.1% vs. 3.2%, P<0.01). The increase in METs was significantly greater in the STDP group than in the placebo group (change: -0.4 vs. 0.0, change rate: -5.0% vs. 0.0%, P<0.01). The improvement of total angina symptom scores (25.0% vs. 0.0%), CM symptom scores (38.7% vs. 11.8%), reduction of nitroglycerin consumption (100.0% vs. 11.3%), and all domains of SAQ, were significantly greater with STDP than placebo (all P<0.01). The changes in Q-T intervals at 28 and 56 days from baseline were similar between the two groups (both P>0.05). Twenty-five participants (16.3%) with STDP and 16 (10.5%) with placebo experienced AEs (P=0.131), with no serious AEs observed.
CONCLUSION
STDP could improve exercise tolerance in patients with stable angina and phlegm-heat and blood stasis syndrome, with a favorable safety profile. (Registration No. ChiCTR-IPR-15006020).
Humans
;
Double-Blind Method
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Middle Aged
;
Angina, Stable/physiopathology*
;
Aged
;
Syndrome
;
Treatment Outcome
;
Placebos
;
Tablets

Result Analysis
Print
Save
E-mail