1.Effect of sodium-glucose cotransporter 2 inhibitor empagliflozin in alleviating uremic cardiomyopathy and related mechanism
Shi CHENG ; Yeqing XIE ; Wei LU ; Jiarui XU ; Yong YU ; Ruizhen CHEN ; Bo SHEN ; Xiaoqiang DING
Chinese Journal of Clinical Medicine 2025;32(2):248-258
Objective To investigate the effect of sodium-glucose cotransporter 2 inhibitor (empagliflozin, EMPA) on myocardial remodeling in a mouse uremic cardiomyopathy (UCM) model induced by 5/6 nephrectomy, through the phosphatidylinositol 3 kinase (PI3K)/protein kinase B (PKB/AKT)/p65 signaling pathway. Methods The animals were divided into three groups: Sham group (n=6), UCM group (n=8), and UCM+EMPA group (n=8). A UCM model was established in C57BL/6N mice using the 5/6 nephrectomy. Starting from 5 weeks post-surgery, EMPA or a placebo was administered. After 16 weeks, blood pressure, serum creatinine, blood urea nitrogen, 24-hour urine glucose and urine sodium were measured. Cardiac structure and function were assessed by echocardiography. Hematoxylin-eosin (HE) staining and Masson trichrome staining were used to observe pathological changes in the heart and kidneys. Wheat germ agglutinin (WGA) staining was used to evaluate myocardial hypertrophy. The real-time quantitative PCR (RT-qPCR) was used to detect the expression levels of myocardial hypertrophy- and fibrosis-related mRNAs. Western blotting was used to detect the expression levels of PI3K, AKT and p65 in myocardial tissues. Results After 16 weeks, UCM group exhibited significantly higher blood pressure, serum creatinine, blood urea nitrogen than sham group (P<0.01); UCM+EMPA group exhibited lower blood pressure, serum creatinine, blood urea nitrogen, and higher 24 h urine sodium and glucose than UCM group (P<0.05). Echocardiographic results showed ventricular remodeling in the UCM group, evidenced by left ventricular wall thickening, left ventricular enlargement, increased left ventricular mass, and decreased systolic function (P<0.05); ventricular remodeling was alleviated (P<0.05), though there was no significant improvement in systolic function in UCM+EMPA group. HE and Masson stainings revealed myocardial degeneration, necrosis, and interstitial fibrosis in UCM group (P<0.01); the myocardial pathology improved with reduced collagen deposition in UCM+EMPA group (P<0.01). WGA staining confirmed myocardial hypertrophy in UCM group (P<0.01), while myocardial hypertrophy was alleviated in UCM+EMPA group (P<0.01). RT-qPCR results showed myocardial hypertrophy- and fibrosis-related genes (NPPA, NPPB, MYH7, COL1A1, COL3A1, TGF-β1) were upregulated in UCM group (P<0.05), but downregulated in UCM+EMPA group. Western blotting showed PI3K, p-AKT/AKT ratio, and p-p65/p65 ratio were increased in UCM group, but decreased in UCM+EMPA group (P<0.05). Conclusion EMPA can improve myocardial hypertrophy and fibrosis in the UCM mouse model, and it may play the role through inhibiting the PI3K/AKT/p65 signaling pathway.
2.Effect of Modified Yiyi Fuzi Baijiang Powder on intestinal mucosal permeability and expression of AQP3, AQP4 in ulcerative colitis rats.
Wen-Xiao LI ; Jiang CHEN ; Zhi-Cheng HE ; Lu-Rong ZHANG ; Guo-Qiang LIANG ; Xing-Xing JIANG ; Yong-Na WEI ; Qin ZHOU
China Journal of Chinese Materia Medica 2025;50(14):3962-3968
This study investigated the therapeutic effects and mechanisms of Modified Yiyi Fuzi Baijiang Powder on ulcerative colitis(UC) in rats from the perspective of dampness. SD rats were randomly allocated into six groups(n=10): control, model, mesalazine, and Modified Yiyi Fuzi Baijiang Powder at low(3.96 g·kg~(-1)·d~(-1)), medium(7.92 g·kg~(-1)·d~(-1)), and high(15.84 g·kg~(-1)·d~(-1)) doses. UC was induced in all groups except the control by administration with 3% dextran sulfate sodium(DSS) solution for 7 days. The disease activity index(DAI) was recorded, and the colon tissue was collected for analysis. Histopathological changes were assessed by hematoxylin-eosin staining. Serum levels of D-lactic acid(D-LA) and diamine oxidase(DAO) were measured by ELISA. Immunohistochemistry and PCR were employed to evaluate the expression of aquaporins(AQP3, AQP4) and tight junction proteins [zonula occludens-1(ZO-1) and occludin] at both protein and mRNA levels. Compared with the control group, the model group showed an increased DAI scores(P<0.05), intestinal mucosal damage, elevated serum levels of DAO and D-LA(P<0.05), and decreased expression of AQP3, AQP4, ZO-1, and occludin(P<0.05). Treatment with Modified Yiyi Fuzi Baijiang Powder reduced the DAI scores(P<0.05), lowered the serum levels of D-LA and DAO(P<0.05), and upregulated the expression of AQP3, AQP4, ZO-1, and occludin at both protein and mRNA levels compared with the model group. These findings suggest that Modified Yiyi Fuzi Baijiang Powder exerts therapeutic effects on UC by reducing the intestinal mucosal permeability, promoting colonic mucosal repair, and regulating abnormal intestinal water metabolism, which may involve the upregulation of AQP3 and AQP4 expression.
Animals
;
Colitis, Ulcerative/genetics*
;
Drugs, Chinese Herbal/administration & dosage*
;
Rats, Sprague-Dawley
;
Rats
;
Intestinal Mucosa/metabolism*
;
Male
;
Aquaporin 3/metabolism*
;
Aquaporin 4/metabolism*
;
Permeability/drug effects*
;
Humans
;
Powders
;
Intestinal Barrier Function
3.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
4.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
5.Efficacy and safety of Compound Xuanju Capsules combined with Western medicine in the treatment of type Ш prostatitis with erectile dysfunction: A meta analysis.
Bin WANG ; Hao-Cheng LIN ; Yong-Zheng JIAO ; Jin-Ming JIA ; Wei-Guo MA
National Journal of Andrology 2025;31(1):61-68
OBJECTIVE:
To systematically evaluate the effect and safety of the combination of Compound Xuanju Capsules (CXC) and Western medicine (WM) in the treatment of type Ш prostatitis complicated by ED.
METHODS:
We searched for randomized controlled trials (RCT) on the treatment of type Ш prostatitis complicated by ED with CXC+WM or WM in the Chinese and English databases CNKI, VIP, Wanfang Digital, Duxiu Academic Search and Chaoxing Electronic Book Information Retrieval, Fangzheng Apabi Electronic Book, Google Scholar Search, Web of Science, Scopus, PubMed, and others from their establishment to April 2024. According to the Cochrane Handbook requirement, we subjected the identified RCTs to meta-analysis using the RevMan 5.3 software.
RESULTS:
A total of 16 eligible studies were identified, involving 742 cases treated by combination therapy of CXC+WM and another 742 with WM alone. The results of meta-analysis showed that the rate of clinical effectiveness was dramatically higher in the CXC+WM than in the WM group (P<0.01, MD = 6.19, 95% CI: 4.63-8.28), and so were the IIEF-5 scores (P < 0.004, MD = 2.90, 95% CI: 0.90-4.89), while the quality of life (QOL) scores were significantly lower in the former group than in the latter (P<0.01, MD = -1.94, 95% CI: -2.47--1.40), and so were the NIH-CPSI scores (P<0.01, MD = -3.92, 95% CI: -4.94--2.91). No statistically significant difference was reported in the adverse reactions between the two groups (P = 0.12, MD = 0.03, 95% CI: -0.01-0.08). Publication bias analysis on the effectiveness rate of the results revealed an incomplete symmetry between the two sides of the funnel plot, indicating the possibility of publication biases.
CONCLUSION
The combination therapy of CXC+WM is superior to WM alone in the treatment of type Ш prostatitis complicated by ED for its high safety and effect of improving the patients' erectile function, but inferior to the latter in improving the QOL and NIH-CPSI scores of the patients.
Male
;
Humans
;
Prostatitis/complications*
;
Erectile Dysfunction/complications*
;
Drugs, Chinese Herbal/therapeutic use*
;
Capsules
;
Randomized Controlled Trials as Topic
;
Drug Therapy, Combination
;
Treatment Outcome
;
Quality of Life
;
Phytotherapy
6.Evolution-guided design of mini-protein for high-contrast in vivo imaging.
Nongyu HUANG ; Yang CAO ; Guangjun XIONG ; Suwen CHEN ; Juan CHENG ; Yifan ZHOU ; Chengxin ZHANG ; Xiaoqiong WEI ; Wenling WU ; Yawen HU ; Pei ZHOU ; Guolin LI ; Fulei ZHAO ; Fanlian ZENG ; Xiaoyan WANG ; Jiadong YU ; Chengcheng YUE ; Xinai CUI ; Kaijun CUI ; Huawei CAI ; Yuquan WEI ; Yang ZHANG ; Jiong LI
Acta Pharmaceutica Sinica B 2025;15(10):5327-5345
Traditional development of small protein scaffolds has relied on display technologies and mutation-based engineering, which limit sequence and functional diversity, thereby constraining their therapeutic and application potential. Protein design tools have significantly advanced the creation of novel protein sequences, structures, and functions. However, further improvements in design strategies are still needed to more efficiently optimize the functional performance of protein-based drugs and enhance their druggability. Here, we extended an evolution-based design protocol to create a novel minibinder, BindHer, against the human epidermal growth factor receptor 2 (HER2). It not only exhibits super stability and binding selectivity but also demonstrates remarkable properties in tissue specificity. Radiolabeling experiments with 99mTc, 68Ga, and 18F revealed that BindHer efficiently targets tumors in HER2-positive breast cancer mouse models, with minimal nonspecific liver absorption, outperforming scaffolds designed through traditional engineering. These findings highlight a new rational approach to automated protein design, offering significant potential for large-scale applications in therapeutic mini-protein development.
7.Diagnostic value of ultrasonography and CT in acute appendicitis
Kai LU ; Chong SUN ; Juan MIAO ; Kaibo ZHOU ; Wei WANG ; Hua YANG ; Yong CHENG
Journal of Practical Radiology 2024;40(4):586-589
Objective To compare the diagnostic value of ultrasonography and CT in acute appendicitis.Methods A retrospective analysis was conducted on 279 patients who were diagnosed with acute appendicitis and followed emergency surgery.Patients were divided into different subgroups based on postoperative pathological results and body mass index(BMI),and the pathological results were used as the gold standard to analyze whether there were differences in the diagnostic accuracy of ultrasonography and CT examination for acute appendicitis.Results A total of 279 patients with confirmed acute appendicitis,with 64 cases of simple appendicitis,127 cases of suppurative appendicitis,and 88 cases of gangrenous appendicitis according to pathological classification.The diagnostic accuracy of ultrasonography was 68.75%(44/64),73.22%(93/127),and 81.81%(72/88),respectively.The diagnostic accuracy of CT was 71.87%(46/64),82.67%(105/127),and 90.90%(80/88),respectively.There was no statistically significant difference in diagnostic accuracy between the two examinations(P>0.05).Subgroup analysis based on patient BMI showed that there was no difference in diagnostic accuracy of the two examinations for patients with normal BMI(P>0.05),while for overweight and obese patients,the diagnostic accuracy of CT was better than that of ultrasonography,with a statistical difference(P<0.05).Conclusion There is no difference in the diagnostic accuracy of ultrasonography and CT examinations for acute appendicitis of different pathological types.But for overweight and obese acute appendicitis patients,the diagnostic accuracy of CT examination is superior to ultrasonography.
8.Expert consensus on the diagnosis and treatment of osteoporotic proximal humeral fracture with integrated traditional Chinese and Western medicine (version 2024)
Xiao CHEN ; Hao ZHANG ; Man WANG ; Guangchao WANG ; Jin CUI ; Wencai ZHANG ; Fengjin ZHOU ; Qiang YANG ; Guohui LIU ; Zhongmin SHI ; Lili YANG ; Zhiwei WANG ; Guixin SUN ; Biao CHENG ; Ming CAI ; Haodong LIN ; Hongxing SHEN ; Hao SHEN ; Yunfei ZHANG ; Fuxin WEI ; Feng NIU ; Chao FANG ; Huiwen CHEN ; Shaojun SONG ; Yong WANG ; Jun LIN ; Yuhai MA ; Wei CHEN ; Nan CHEN ; Zhiyong HOU ; Xin WANG ; Aiyuan WANG ; Zhen GENG ; Kainan LI ; Dongliang WANG ; Fanfu FANG ; Jiacan SU
Chinese Journal of Trauma 2024;40(3):193-205
Osteoporotic proximal humeral fracture (OPHF) is one of the common osteoporotic fractures in the aged, with an incidence only lower than vertebral compression fracture, hip fracture, and distal radius fracture. OPHF, secondary to osteoporosis and characterized by poor bone quality, comminuted fracture pattern, slow healing, and severely impaired shoulder joint function, poses a big challenge to the current clinical diagnosis and treatment. In the field of diagnosis, treatment, and rehabilitation of OPHF, traditional Chinese and Western medicine have accumulated rich experience and evidence from evidence-based medicine and achieved favorable outcomes. However, there is still a lack of guidance from a relevant consensus as to how to integrate the advantages of the two medical systems and achieve the integrated diagnosis and treatment. To promote the diagnosis and treatment of OPHF with integrated traditional Chinese and Western medicine, relevant experts from Orthopedic Expert Committee of Geriatric Branch of Chinese Association of Gerontology and Geriatrics, Youth Osteoporosis Group of Orthopedic Branch of Chinese Medical Association, Osteoporosis Group of Orthopedic Surgeon Branch of Chinese Medical Doctor Association, and Osteoporosis Committee of Shanghai Association of Integrated Traditional Chinese and Western Medicine have been organized to formulate Expert consensus on the diagnosis and treatment of osteoporotic proximal humeral fracture with integrated traditional Chinese and Western medicine ( version 2024) by searching related literatures and based on the evidences from evidence-based medicine. This consensus consists of 13 recommendations about the diagnosis, treatment and rehabilitation of OPHF with integrated traditional Chinese medicine and Western medicine, aimed at standardizing, systematizing, and personalizing the diagnosis and treatment of OPHF with integrated traditional Chinse and Western medicine to improve the patients ′ function.
9.Finite element analysis of absorbable screws in Bernese periacetabular osteotomy
Hui CHENG ; Xiaoying MA ; Ningtao REN ; Zhendong ZHANG ; Haigang JIA ; Yong LI ; Jianli ZHANG ; Dianzhong LUO ; Hong ZHANG ; Wei CHAI
Chinese Journal of Orthopaedics 2024;44(6):419-426
Objective:To investigate the stability and feasibility of using absorbable screws during Bernese periacetabular osteotomy.Methods:A retrospective analysis was conducted on a 36 year-old woman diagnosed with developmental dysplasia of the hip, who had undergone Bernese periacetabular osteotomy. Finite element analysis was used to simulate the stability of the acetabulum under loads of 10%, 20%, 50%, and 100% of the patient's weight. The structural stiffness of the pelvis and the maximum equivalent stress on the absorbable screws were observed under different conditions, including whether the acetabular bone block and the ilium were in contact, whether 3 or 4 screws were used, and whether a graft (including fibular cortical bone and PEEK grafts) was used.Results:The structural stiffness of the pelvis fixed with four screws increased by 67%-94% compared to that with three screws. After using a graft, the structural stiffness of the pelvis increased by 50%-83%. As the load increased, the maximum equivalent stress on the screws also increased. When the acetabular bone block and the ilium had no contact, no graft was used, and only three screws were used for fixation, the maximum equivalent stress could reach 518.9 MPa, while this value dropped to 61% when four screws were used (318.7 MPa). When the acetabular bone block and the ilium were in contact, the maximum equivalent stress was about 12% of that when there was no contact, regardless of the number of screws used. When a cortical bone graft or a PEEK graft was used, the maximum equivalent stress could drop to 21%-26% of that without a graft. When the screw strength was 130 MPa, a load of 20% of body weight was applied, and only three screws were used without a graft, the equivalent stress could exceed the strength of the screw; if four screws were used, the equivalent stress was slightly higher than the strength of the screw when a load of 50% of body weight was applied. However, when a graft was used (either cortical bone or PEEK), even when a load of 100% of body weight was applied, the equivalent stress was slightly lower than the strength of the screw.Conclusion:Absorbable screws can provide sufficient stability for Bernese periacetabular osteotomy. The contact between the acetabular bone block and the ilium, an increase in the number of screws, and the use of grafts (cortical bone and PEEK grafts) can further improve stability. Therefore, absorbable screws have broad application prospects in Bernese periacetabular osteotomy.
10.Clinical efficacy of closure operation guided by transthoracic echocardiography with simply delivery sheath for patent foramen ovale
Yong-Quan GONG ; Chao-Rong CHEN ; Wei NONG ; Tian-Cheng LU ; Cheng-Xin WEI ; Xian-Qiu WU
Journal of Regional Anatomy and Operative Surgery 2024;33(2):129-132
Objective To investigate the clinical efficacy of percutaneous closure of foramen ovale guided by transthoracic echocardio-graphy with simply delivery sheath.Methods The clinical data of patients with patent foramen ovale underwent interventional closure and percutaneous closure guided by transthoracic echocardiography with simply delivery sheath in our hospital from January 2020 to December 2022 were analyzed retrospectively,the patients were divided into interventional closure group(40 cases)and simply delivery sheath group(39 cases).The operation time,incidence of surgical complications,and surgical success rates of patients in the two groups were compared.The closure effect were evaluated by ultrasound immediately after surgery.All the patients were followed up for 6 months after surgery to evaluate remission of the symptoms.Results The surgical success rate of simply delivery sheath group(100%)was higher than that of interventional closure group(90.0%),with statistically significant difference(P<0.05).The operation time of simply delivery sheath group was longer than that of interventional closure group,with statistically significant difference(P<0.05).One patient in the interventional closure group had small amount of pericardial effusion during the operation.Two patients had decreased blood pressure and slowed heart rate in simply delivery sheath group,and symptoms disappeared after treatment.There was no significant difference in the incidence of complications between the two groups(P>0.05).After 6-month follow-up,all occluders were in good position and no residual leakage was found.The symptoms of headache or dizziness disappeared in 28 patients in interventional closure group,significantly relieved in 8 patients;the symptoms of headache or dizziness disappeared in 30 patients in simply delivery sheath group,and significantly relieved in 9 patients.Conclusion Percutaneous closure for patent foramen ovale under the guidence of transthoracic echocardiography with simply delivery sheath is safe and feasible with satisfactory efficacy and higher successful rate without radiation hazard.It is worthy of clinical promotion.

Result Analysis
Print
Save
E-mail