1.Evaluation of the anticoagulant effect of nafamostat mesylate in continuous veno-venous hemofiltration with different dilution methods for uremic patients
Li SHEN ; Yao ZHANG ; Jun WANG ; Hong ZHU ; Yong QIN ; Yuewu TANG ; Ni DU
China Pharmacy 2026;37(3):350-355
OBJECTIVE To evaluate the anticoagulant efficacy and safety of nafamostat mesylate (NM) in the treatment of uremic patients at high risk of bleeding undergoing continuous veno-venous hemofiltration (CVVH) with different methods (pre- dilution and post-dilution). METHODS A total of 130 uremic patients at high risk of bleeding who underwent CVVH treatment in the nephrology department of Chongqing University Three Gorges Hospital from July 2023 to September 2024 were selected. They were divided into pre-dilution group and post-dilution group according to the random number table method, with 65 cases in each group. Both groups of patients received CVVH treatment under NM anticoagulation. The pre-dilution group adopted the pre-dilution replacement method, while the post-dilution group adopted the post-dilution replacement method. The coagulation, pressure, and usage duration of the filter and dialysis circuit venous reservoirs were compared between the two groups. The changes in prothrombin time (PT), prothrombin time-international normalized ratio (PT-INR), activated partial thromboplastin time (APTT), and fibrinogen (FIB) in the peripheral venous blood before the heparin pump and after the filter at 1, 4 and 7 h of CVVH treatment, as well as 20 min after the end of treatment, were compared between the two groups. The single-compartment urea clearance rate (spKt/V), β2-microglobulin (β2-MG) clearance rate and the incidence of adverse reactions were duni2007@foxmail.com compared between the two groups. RESULTS Both the pre-dilution and post-dilution groups had 60 patients who completed the study. The incidence of grade Ⅱ-Ⅲ coagulation of the filter and venous reservoirs, as well as the number of patients with transmembrane and venous pressure alarm intervention in the post- dilution group were significantly higher or more than those in the pre-dilution group (P<0.05), while usage time of the filter and the pipeline in the post-dilution group was significantly shorter than that in the pre-dilution group (P<0.05). The APTT values before the heparin pump as well as PT and APTT values after the filter at 1 h, 4 h, and 7 h of CVVH treatment in the post-dilution group were significantly higher than those in the pre-dilution group (P<0.001). There were no significant differences in PT, PT- INR, APTT and FIB between the two groups of patients 20 min after the end of treatment (P>0.05). The spKt/v and β2-MG clearance rates in the post-dilution group were significantly higher than those in the pre-dilution group (P<0.001). There was no significant difference in the incidence of adverse reactions between the two groups (P>0.05). CONCLUSIONS When NM is used as an anticoagulant in the CVVH treatment of uremic patients at high risk of bleeding, compared with the pre-dilution treatment method, the post-dilution treatment method has a higher incidence of filter and dialysis tubing venous reservoir, a shorter usage time of the filter and pipeline, and a greater impact on extracorporeal coagulation, but has a higher solute clearance rate. Clinically, different dilution methods can be selected according to the different treatment needs of patients.
2.The surgeon's crucial role in the era of transcatheter aortic valve replacement:lifetime management
Tong TAN ; En-jun ZHU ; Hao CUI ; Yong-qiang LAI
Chinese Journal of Interventional Cardiology 2025;33(4):227-230
Transcatheter aortic valve replacement(TAVR)is increasingly being applied in low-risk and younger patients.However,this trend necessitates that cardiac surgeons take on the responsibility of comprehensive lifetime management.This article explores three critical aspects of lifetime management,including the selection of the initial valve,the procedural success and the device success rates of TAVR,and the durability of the valve.Younger TAVR recipients require comprehensive lifetime management strategies,including the potential risk of reintervention.Improving TAVR's procedural and device success rates is the cornerstone of lifetime management,necessitating efforts in surgical strategy and operation to reduce complications.Valve durability is a key guarantee;current surgical bioprosthetic valves show good durability,but long-term data on TAVR valves'durability is still needed.Meanwhile,novel valves are being improved in durability,offering new directions for optimizing lifetime management in TAVR patients.
3.Analysis of transurethral water vapor thermal therapy for the treatment of benign prostatic hyperplasia
Ming-yang PANG ; Yong WEI ; Jian-zhong LIN ; Jun WANG ; Ming-yu LIU ; Fu-yang LIU ; Yi-bo MA ; Tong ZHAO ; Qing-yi ZHU
National Journal of Andrology 2025;31(7):603-607
Objective:To investigate the efficacy and safety of transurethral water vapor thermal therapy(WVTT)using the Rezūm system for benign prostatic hyperplasia(BPH)in the real world.Methods:A total of 181 patients with BPH were recruited from the Second Affiliated Hospital of Nanjing Medical University from August 2022 to December 2023,of whom 173 patients were treated with WVTT using the Rezūm system,while 8 patients were treated with WVTT combined with TURP.They were followed up at 1,3,and 6 months postoperatively to assess changes in the IPSS,QoL,Qmax,IIEF-5,and the occurrence of any complications.Results:All 181 surgeries in this group were successfully completed.The operation time of the Rezūm system was(4.6±1.4)mi-nutes.The postoperative indwelling catheterization time was(8.0±2.1)days.With a follow-up of at least 6 months,there was a significant decrease in PV,IPSS and QoL,and a remarkable increase had been found in Qmax as well(P<0.05).There was no sig-nificant difference in IIEF-5 before and after the operation(P>0.05).In this groups of patients,postoperative complications mainly included 95 cases(52.5%)of gross hematuria,6 cases(3.3%)of retrograde ejaculation,5 cases(2.8%)of urethral stricture,4 cases(2.2%)of prostatitis,and 10 cases(5.5%)of urinary tract infection.Four cases(2.2%)underwent surgical retreatment for BPH after surgery.Conclusion:In the real world,the use of Rezūm thermal steam ablation system for the treatment of BPH has sat-isfactory short-term effect,short surgical time,and significant improvement in IPSS,QoL,Qmax,which does not adversely affect sexu-al function.
4.Distribution and source tracing analysis of drug-resistant bacteria in the environment at pig farms in Shandong Province
Shu-meng YOU ; Yong WANG ; Da-yang ZOU ; Hong-bin WANG ; Jun-zhu BAI ; Dan-jie ZHANG ; Liang WEN ; Yuan-yong XU ; Wen-yi ZHANG
Chinese Journal of Zoonoses 2025;41(6):623-628
This study investigated the drug resistance and genetic relationships among strains co-existing in animals,the environ-ment,and the living quarters of employees at large-scale pig farms in certain regions of Shandong Province,to provide a scientific ba-sis for elucidating the transmission mechanisms of drug-resistant bacteria through bacterial traceability analysis.Samples were col-lected from two pig farms,and bacteria were isolated and purified.The species of the isolated strains were identified via 16S rRNA gene sequencing.Antimicrobial susceptibility testing was conducted with a VITEK-2 Compact system and the disk diffusion method for strains present in pigs,the environment,and living areas.Furthermore,whole-genome sequencing was performed on the Illumina Miniseq platform to annotate drug resistance genes,and multilocus sequence typing(MLST)and core genome single nucleotide poly-morphism(cgSNP)analyses were used to trace the resistant strains.Three species—Staphylococcus aureus,Pseudomonas aeruginosa,and Bacillus cereus—were isolated and cultured from animals,the environment,and employee living areas,and their distributions were analyzed.These strains exhibited diverse drug resistance spectra and genetic diversity.Additionally,the strains displayed highly consistent resistance profiles,resistance genes,ST types,and SNP loci in pig urine,soil both inside and outside the facility,human drinking water,and the cafeteria and dormitories.Our findings indicated a potential risk of transmission of opportunistic pathogens be-tween the pig farming area and the living quarters.Particular attention should be paid to the environmental transmission of methicillin-resistant Staphylococcus aureus.
5.Surgical efficacy evaluation of NF1-related dystrophic lumbosacral deformity: comparative analysis between pelvic and non-pelvic fixation
Song LI ; Zezhang ZHU ; Jie ZHOU ; Saihu MAO ; Shuqi SUN ; Zhen LIU ; Benlong SHI ; Xu SUN ; Jun QIAO ; Yong QIU
Chinese Journal of Orthopaedics 2025;45(9):604-612
Objective:To analyze the selection of internal fixation methods, surgical outcomes, and complications in patients with Neurofibromatosis Type 1 (NF1) accompanied by dystrophic lumbosacral deformities, and to evaluate the indications for pelvic fixation.Methods:A retrospective analysis was conducted on 21 patients with NF1 and associated dystrophic lumbosacral malformations (L 4 to sacrum) who underwent spinal deformity correction surgery at Nanjing Drum Tower Hospital from January 2009 to November 2022. The cohort included 11 males and 10 females, with a mean surgical age of 15.4±4.7 years (range, 7-24 years). Patients were divided into two groups based on whether pelvic fixation was performed: 10 patients in the non-pelvic fixation group (NP group) and 11 in the pelvic fixation group (P group), where fixation involved second sacral alar-iliac (S 2AI) screws or iliac screws. Radiographic parameters, including the Cobb angle of the lumbosacral fractional curve, main curve, and focal kyphosis, were compared preoperatively, postoperatively, and at the last follow-up. Results:The NP group had a significantly lower mean age (13.2±4.9 years) compared to the P group (17.5±3.5 years; t=2.287, P=0.034). Spinal instability (rotational subluxation or spondylolisthesis) due to dystrophic changes was observed in 2 patients in the NP group and 8 in the P group, a statistically significant difference (χ 2=5.838, P=0.030). In the P group, five patients underwent unilateral fixation and six underwent bilateral fixation. Implant types included 2 cases with iliac screws, 1 case with iliac screws plus S 2AI, and 8 cases with S 2AI screws alone. The utilization rate of hooks was significantly higher in the NP group (12.6%±11.5%) compared to the P group (3.5%±6.9%; t=2.230, P=0.038). The preoperative Cobb angle of the lumbosacral fractional curve was significantly smaller in the NP group (13.8°±9.0°) than in the P group (25.5°±13.9°; t=2.228, P=0.039). Postoperatively, the angles were corrected to 6.3°±6.1° and 6.4°±5.3°, respectively ( t=0.901, P=0.969), with correction rates of 57.3%±13.6% and 74.1%±17.8% ( t=2.369, P=0.029). At final follow-up, the angles remained stable (6.6°±6.6° vs. 6.3°±4.8°; t=0.116, P=0.909). For the main curve, preoperative Cobb angles were 52.5°±15.1° (NP) and 61.1°±16.9° (P; t=1.200, P=0.246), corrected to 31.3°±13.8° and 28.0°±8.4°, respectively ( t=0.646, P=0.526). Correction rates were 41.3%±13.0% in the NP group and 53.2%±11.6% in the P group ( t=2.206, P=0.037). At the final follow-up, these values were 32.4°±14.2° and 31.7°±10.3° ( t=0.133, P=0.896). Focal kyphosis, seen in 9 patients, was corrected from 19.7°±10.9° preoperatively to -13.6°±9.5° postoperatively, and remained at -14.1°±9.6° at the final follow-up ( F=33.547, P<0.001). Multi-rod systems were used in 6 cases (NP group) and 7 cases (P group), with no significant difference (χ 2=0.153, P=0.926). Two patients in the NP group developed coronal decompensation three years postoperatively, and one required revision surgery. In the P group, rod breakage occurred in 3 patients, two of whom underwent revision. Conclusions:Dystrophic rotational subluxation or spondylolisthesis of the lumbosacral spine is a primary indication for pelvic fixation in patients with NF1-associated deformities. However, complications related to internal fixation remain common. The combined use of a multi-rod screw-hook hybrid system, particularly when extending across the lumbosacral region, may reduce the risk of instrumentation failure.
6.Development of a visualizable machine learning model for mechanical complication risk in adult spinal deformity surgery
Jie LI ; Zhen TIAN ; Zhong HE ; Xiaodong QIN ; Jun QIAO ; Saihu MAO ; Benlong SHI ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Chinese Journal of Orthopaedics 2025;45(17):1137-1146
Objective:To predict mechanical complications (MC) following spinal deformity surgery for adult spine deformity (ASD) using machine learning models, identify key risk factors, and develop a visualizable tool for individualized risk assessment.Methods:Clinical and radiological data from 525 patients with ASD who underwent surgery in our hospital between January 2017 and December 2021 were collected. Patients were randomly assigned to a training set (70%) and a test set (30%) for model development. The cohort included 88 males and 437 females, with a mean age of 42.2±18.1 years. Variables included demographic data, comorbidities, local and systemic radiological parameters, paraspinal muscle fat infiltration (FI), and vertebral bone quality (VBQ) scores. Multiple machine learning algorithms: Random Forest (RF), Gaussian Naive Bayes (GNB), Light GBM, Support Vector Machine (SVM), XGBoost (XGB), and Logistic Regression (LR) were trained and evaluated. Model performance was compared using the receiver operating characteristic curve (ROC) and precision-recall curve (PRC). SHAP (Shapley Additive Explanations) was used to rank risk factors, while LIME (Local Interpretable Model-Agnostic Explanations) was applied to visualize MC risk in individual cases.Results:Of the 525 patients, 135 (25.7%) developed postoperative MC. Among these, 80 (59.3%) experienced proximal junction kyphosis or failure (PJK/PJF), 7 (5.2%) had distal junction kyphosis or failure (DJK/DJF), 28 (20.7%) sustained rod fractures, and 29 (21.5%) showed significant loss of correction. In the validation cohort, the RF model achieved the highest area under the curve (AUC=0.80), followed by GNB (0.77), XGB (0.76), LR (0.74), LightGBM (0.73), and SVM (0.66). The RF model also demonstrated the best PRC value (0.58), highest sensitivity (0.65), and lowest Brier score (0.20). GNB, Light GBM, and LR models achieved the highest accuracy (0.78 each), while LightGBM exhibited the highest specificity (0.93). SHAP analysis identified higher preoperative VBQ scores, larger T 1 pelvic angle (TPA), and higher paraspinal muscle FI as the main risk factors for MC. Based on the RF model, a LIME-based tool was successfully constructed for individualized MC risk estimation. Conclusion:The RF model demonstrated the best overall predictive performance for MC. A machine learning-based prediction model has the potential to provide valuable guidance for surgical decision-making in ASD patients.
7.Expression and significance of circular RNA hsa_circ_0001766 in tissues and serum of gastric cancer patients
Yong ZHOU ; Zhixiang XU ; Yazhen WANG ; Xiaoming LEI ; Yahui FAN ; Juan ZHANG ; Weilong WANG ; Xin ZHU ; Jun YAO
Chinese Journal of Clinical Laboratory Science 2025;43(7):500-504
Objective To investigate the expression level and clinical application value of circular RNA hsa_circ_0001766 in gastric cancer(GC)tissues and serum of patients with GC.Methods The PCR amplification products from GES-1 cells of normal gastric mucosa were analyzed for the cyclic sites of hsa_circ_0001766 by the Sanger sequencing technique.The expression levels of hsa_circ_0001766 in GES-1 cells treated or untreated with RNase R(RNase R)were detected by real-time fluorescence quantitative PCR(qRT-PCR).The expression levels of hsa_circ_0001766 in GC and adjacent tissues of 73 GC patients and serum samples of 34 GC patients were also detected by qRT-PCR.The receiver operating characteristics(ROC)curve was used to evaluate the clinical diag-nostic value of hsa_circ_0001766 in GC.The correlations between hsa_circ_0001766 and clinicopathological parameters in GC patients were also analyzed.Results There was cyclic sites in hsa_circ_0001766 and RNase R had no significant impact on the expression lev-el of hsa_circ_0001766 in GES-1 cells(t=1.678,P=0.169).Compared with adjacent tissues,the expression levels of hsa_circ_0001766 in GC tissues were significantly up-regulated(U=1 360,P<0.001).Compared with healthy controls,the expres-sion levels of hsa_circ_0001766 in serum of GC patients were significantly up-regulated(U=375,P<0.001).The area under the ROC curve(AUCROC),sensitivity,and specificity of hsa_circ_0001766 in GC tissues for diagnosing GC were 0.759(95%CI:0.682-0.837,P<0.000 1),79.45%,and 68.49%,respectively.The AUCROC,sensitivity,and specificity of serum hsa_circ_0001766 in diagnosing GC were 0.773(95%CI:0.662-0.884,P<0.000 1),73.53%,and 72.12%,respectively.The expression levels of hsa_circ_0001766 in GC tissues were correlated with lymph node metastasis(x2=5.509,P=0.019)and TNM staging(x2=5.161,P=0.023).The 3-year survival rate of GC patients with high expression of hsa_circ_0001766 in GC tissues was significantly lower than that with low ex-pression(x2=3.700,P=0.037).Conclusion The hsa_circ_0001766 in GC tissues and serum of GC patients is highly expressed,and its change in the expression level is of great significance for the diagnosis and prognostic evaluation of GC patients.
8.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
9.Lymph node metastasis in the prostatic anterior fat pad and prognosis after robot-assisted radical prostatectomy
Zhou-jie YE ; Yong SONG ; Jin-peng SHAO ; Wen-zheng CHEN ; Guo-qiang YANG ; Qing-shan DU ; Kan LIU ; Jie ZHU ; Bao-jun WANG ; Jiang-ping GAO ; Wei-jun FU
National Journal of Andrology 2025;31(3):216-221
Objective:To investigate lymph node metastasis(LNM)in the prostatic anterior fat pad(PAFP)of PCa patients after robot-assisted radical prostatectomy(RARP),and analyze the clinicopathological features and prognosis of LNM in the PAFP.Methods:We retrospectively analyzed the clinicopathological data on 1 003 cases of PCa treated by RARP in the Department of Urolo-gy of PLA General Hospital from January 2017 to December 2022.All the patients underwent routine removal of the PAFP during RARP and pathological examination,with the results of all the specimens examined and reported by pathologists.Based on the pres-ence and locations of LNM,we grouped the patients for statistical analysis,compared the clinicopathological features between different groups using the Student's t,Mann-Whitney U and Chi-square tests,and conducted survival analyses using the Kaplan-Meier and Log-rank methods and survival curves generated by Rstudio.Results:Lymph nodes were detected in 77(7.7%)of the 1 003 PAFP samples,and LNM in 11(14.3%)of the 77 cases,with a positive rate of 1.1%(11/1 003).Of the 11 positive cases,9 were found in the upgraded pathological N stage,and the other 2 complicated by pelvic LNM.The patients with postoperative pathological stage≥T3 constituted a significantly higher proportion in the PAFP LNM than in the non-PAFP LNM group(81.8%[9/11]vs 36.2%[359/992],P=0.005),and so did the cases with Gleason score ≥8(87.5%[7/8]vs 35.5%[279/786],P=0.009).No statisti-cally significant differences were observed in the clinicopathological features and biochemical recurrence-free survival between the pa-tients with PAFP LNM only and those with pelvic LNM only.Conclusion:The PAFP is a potential route to LNM,and patients with LNM in the PAFP are characterized by poor pathological features.There is no statistically significant difference in biochemical recur-rence-free survival between the patients with PAFP LNM only and those with pelvic LNM only.Routine removal of the PAFP and inde-pendent pathological examination of the specimen during RARP is of great clinical significance.
10.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.

Result Analysis
Print
Save
E-mail