1.Research on ERPs Affecting Selective Attention Distraction Inhibition Function of College Students Due to Long Term Emotional Distress
Ruyuan CAO ; Yong LIU ; Junlin HOU ; Ziwei ZHAO ; Zhongpeng QIN ; Chuan ZHAO ; Zhuo CHEN ; Xianghong ZHAN
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(4):1105-1112
Objective Using event-related potentials(ERPs)technology to study the effect of long term emotional distress on selective attention distraction inhibition function in college students and its neuroelectrophysiological mechanism.Methods The Eysenck personality questionnaire(EPQ)adult version was used to screen the high and low neuroticism groups among college students,and 35 subjects in each group were included in the long term emotional distress group and the emotional smoothness control group,respectively,and the response time,correct rate,N2 and P3 amplitude and latency results of the participants to complete the negative priming paradigm task were collected and analyzed.Results Compared with the control group,① the long term emotional distress group showed a prolonged response trend(P=0.072).② the long term emotional distress group had a prolonged N2 and P3 latency(P<0.05).Conclusion Selective attention distraction inhibition in college students with long term emotional distress decreased,and the decline mechanism may be related to the decline of inhibition processing and attention resource allocation ability.
2.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
3.Problems and suggestions for minor purchasing of medical equipment
Xian-ju YUAN ; Fei-ba CHANG ; Yong CHEN ; Cheng-qun MA ; Jia TAN ; Xi GUO ; Jin-chuan HAN
Chinese Medical Equipment Journal 2025;46(8):91-95
The minor purchasing process and mode of some hospital were introduced,and the implementation of the hospital's minor purchasing projects in the past year was analyzed.The causes for high failure rate of purchasing were pointed out including long interval between project creation and procurement,unreasonable demand presentation,insufficient demand demonstration and lack of active participation of suppliers.Some suggestions were put forward such as timely adjustment of demands,strengthening of demand demonstration,improvement of supplier motivation and enhancement of procurement process management,which were of great significance for increasing the success rate of minor purchasing of the hospital.[Chinese Medical Equipment Journal,2025,46(8):91-95]
4.Effect of different layers of masseter on the bony structure of facial lateral area
Yu-Qi ZHAO ; Jin-Rui JIANG ; Jin-Ran CHEN ; Ze-Chuan WANG ; Hou-En ZHOU ; Wen-Di XU ; Liu-Jun YONG
Acta Anatomica Sinica 2025;56(2):208-213
Objective To observe the morphology of the superficial,middle,and deep layers of the masseter muscle and related bony structures in the lateral facial region of adults through gross anatomy,and to probe into the effects of these muscle layers on the bony structures of the lateral facial region.Methods The bilateral masseter muscles of 12 adult cadavers were exposed,and the superficial,middle,and deep layers were separated and measured for muscle length,tendon length,and muscle belly length.After the masseter muscles were stripped,the total thickness was measured,and the mandible and zygomatic arch were exposed to measure the angle of the mandibular angle,thickness of the zygomatic arch,and width of the zygomatic arch.Observations were made of the masseter tuberosities,and statistical analysis was conducted on their interrelations.Results The zygomatic arch thickness was positively correlated with the length of superficial,middle and deep masseter muscles and the length of superficial and middle masseter belly(r superficial masseter length=0.624,r middle masseter length=0.787,r deep masseter length=0.423,r superficial masseter belly length=0.493,r middle masseter belly length=0.548).The width of the zygomatic arch was positively correlated with the lengths of the superficial and middle muscle layers and the middle muscle belly length(r superficial masseter length=0.527,r middle masseter length=0.521,r middle masseterbelly length=0.437).The angle of the mandibular angle was only negatively correlated with the middle muscle belly length(r=-0.422).The tuberosities of the superficial and middle masseter muscles were not affected by the corresponding muscle layers;However,the tuberosity of the deep masseter was negatively correlated with the length of the deep muscle and the length of the deep tendon(r deep masseter length=-0.543,r deep masseter tendon length=-0.443).Conclusion In the masseter muscle layers of Chinese individuals,the superficial and middle layers have the most significant impact on the bony structures structures of the lateral facial region.These findings are of guiding significance for the remodeling of structures in the lateral facial region.
5.Problems and suggestions for minor purchasing of medical equipment
Xian-ju YUAN ; Fei-ba CHANG ; Yong CHEN ; Cheng-qun MA ; Jia TAN ; Xi GUO ; Jin-chuan HAN
Chinese Medical Equipment Journal 2025;46(8):91-95
The minor purchasing process and mode of some hospital were introduced,and the implementation of the hospital's minor purchasing projects in the past year was analyzed.The causes for high failure rate of purchasing were pointed out including long interval between project creation and procurement,unreasonable demand presentation,insufficient demand demonstration and lack of active participation of suppliers.Some suggestions were put forward such as timely adjustment of demands,strengthening of demand demonstration,improvement of supplier motivation and enhancement of procurement process management,which were of great significance for increasing the success rate of minor purchasing of the hospital.[Chinese Medical Equipment Journal,2025,46(8):91-95]
6.Research on ERPs Affecting Selective Attention Distraction Inhibition Function of College Students Due to Long Term Emotional Distress
Ruyuan CAO ; Yong LIU ; Junlin HOU ; Ziwei ZHAO ; Zhongpeng QIN ; Chuan ZHAO ; Zhuo CHEN ; Xianghong ZHAN
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(4):1105-1112
Objective Using event-related potentials(ERPs)technology to study the effect of long term emotional distress on selective attention distraction inhibition function in college students and its neuroelectrophysiological mechanism.Methods The Eysenck personality questionnaire(EPQ)adult version was used to screen the high and low neuroticism groups among college students,and 35 subjects in each group were included in the long term emotional distress group and the emotional smoothness control group,respectively,and the response time,correct rate,N2 and P3 amplitude and latency results of the participants to complete the negative priming paradigm task were collected and analyzed.Results Compared with the control group,① the long term emotional distress group showed a prolonged response trend(P=0.072).② the long term emotional distress group had a prolonged N2 and P3 latency(P<0.05).Conclusion Selective attention distraction inhibition in college students with long term emotional distress decreased,and the decline mechanism may be related to the decline of inhibition processing and attention resource allocation ability.
7.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
8.Development and Application of a Micro-device for Rapid Detection of Ammonia Nitrogen in Environmental Water
Peng WANG ; Yong TIAN ; Chuan-Yu LIU ; Wei-Liang WANG ; Xu-Wei CHEN ; Yan-Feng ZHANG ; Ming-Li CHEN ; Jian-Hua WANG
Chinese Journal of Analytical Chemistry 2024;52(2):178-186,中插1-中插3
The analysis of ammonia nitrogen in real water samples is challenging due to matrix interferences and difficulties for rapid on-site analysis.On the basis of the standard method,i.e.water quality-determination of ammonia nitrogen-salicylic acid spectrophotometry(HJ 536-2009),a simple device for online detecting ammonia nitrogen was developed using a sequential injection analysis(SIA)system in this work.The ammonia nitrogen transformation system,color reaction system,and detection system were built in compatible with the SIA system,respectively.In particular,the detection system was assembled by employing light-emitting diode as the light source,photodiode as the detector,and polyvinylchloride tube as the cuvette,thus significantly reducing the volume,energy consumption and fabricating cost of the detection system.As a result,the accurate analysis of ammonia nitrogen in complex water samples was achieved.A quantitative detection of ammonia nitrogen in water sample was obtained in 12 min,along with linear range extending to 1000 μmol/L,precisions(Relative standard deviation,RSD)of 4.3%(C=10 μmol/L,n=7)and 4.2%(C=500 μmol/L,n=7),and limit of detection(LOD)of 0.65 μmol/L(S/N=3,n=7).The results of interfering experiments showed that the detection of ammonia nitrogen by the developed device was not interfered by the common coexisting ions and components,therefore the environmental water could be directly analyzed,such as reservoir water,domestic sewage,sea water and leachate of waste landfill.The analytical results were consistent with those obtained by the environmental protection standard method(Water quality determination of ammonia nitrogen-salicylic acid spectrophotometry,HJ 536-2009).In addition,the spiking recoveries were in the range of 92.3%-98.1%,further confirming the accuracy and practicality of the developed device.
9.Analysis on positioning errors and adverse reactions of breast cancer
Tingting TANG ; Yong ZHONG ; Ping TANG ; Lin HU ; Xuerui ZHENG ; Chuan CHEN
Chongqing Medicine 2024;53(22):3469-3472
Objective To investigate the factors influencing the positioning error of conical beam CT(CBCT)radiotherapy and the occurrence of acute radiation dermatitis in breast cancer fixed by cervical and thoracic integrated membrane in order to provide a basis for personalized out-target external boundary,selec-tion of fixed mode and guidance of radiodermatitis clinical practice work.Methods A total of 147 patients with breast cancer in this hospital from June 2022 to October 2023 were selected as the study subjects,inclu-ding 74 cases of breast conserving operation and 73 cases of modified radical(excision)operation.During the treatment period,CBCT scanning once a week obtained the image and conducted the grey match with the planned CT images to acquire the translational error of X(left and right),Y(head and foot)and Z(abdominal and dorsal)and the rotational posing error of X(pitch),Y(roll)and Z(yaw)axis,and at the same time,the acute radiodermatitis in nearly 3 months during radiotherapeutic period was recorded.Results Compared with the Z axis,the translation error of X axis and Y axis was greater,the rotation error was smaller,and the differ-ences were statistically significant(P<0.05).The PTV external boundary of X,Y and Z axis calculated by the formula was 0.70,0.76,0.46 cm respectively.There was no statistically significant difference in the posi-tioning error of each direction of left and right breast between breast conservation operation and breast resec-tion operation(P>0.05).The correlation between the age with X,Y and Z axis translation errors was-0.14,0.18 and 0.10 respectively,which of the age with X,Y and Z axis rotation errors was 0.12,<0.01,0.02 respectively.The occurrence of grade 1 acute radiodermatitis in the patients with breast conserving oper-ation was 100.0%(74/74),which in the patients with excision operation was 13.7%(10/73),the occurrence of grade 2 was 82.2%,which of grade 3 was 4.1%(3/73),and the difference between them was statistically significant(P<0.05).Conclusion In the every day positioning and target area external expansion,particular attention should be paid to the X and Y axis translational directions and the Z axis rotation direction.Using the integrated cervicothoracic thermoplastic membrane for fixing breast cancer is not affected by the operation mode,affected side position and age.
10.Development and Application of Portable Multi-wavelength Spectroscopic Rapid Detector for Organic Pollutants
Yu-Ping CHEN ; Jia-Chuan PAN ; Yong-Qian LEI ; Chang-Yu LIU ; Jian-Bo JIA ; Peng-Ran GUO
Chinese Journal of Analytical Chemistry 2024;52(5):653-663,中插1-中插9
A portable multi-wavelength spectral detector was developed for on-site,rapid and accurate detection of organic pollutants in surface water using ultraviolet light-emitting diodes(UV-LEDs)and the corresponding spectral detection method was built.By measuring the fluorescence spectrum and absorption light intensity and combining with the multi-wavelength spectral correlation calculation method to analyze the target,the developed detector was able to qualitatively and quantitatively detect organic pollutants that responded in the UV-light range of 260-370 nm.The proposed detector was used to detect polycyclic aromatic hydrocarbons(PAHs)and Rhodamine B.The linear ranges of anthracene and Rhodamine B in absorption mode were 10-100 and 8.5-100 mg/L,respectively.In fluorescence mode,the linear ranges for anthracene and Rhodamine B were 0.006-50 and 0.02-0.781 mg/L,correspondingly.The absorption/fluorescence concurrent mode could extend the detection ranges of anthracene and Rhodamine B to 0.006-100 and 0.02-100 mg/L,respectively.The recoveries of PAHs in surface water ranged from 97.4%to 105.1%for anthracene and 84.5%to 91.2%for anthracene,naphthalene,and pyrene in absorption and fluorescence modes,respectively.The method was accurate in both modes.The mixtures containing PAHs were identified by the proposed method under the optimized multi-wavelength spectral correlation calculation.The results demonstrated that the method could achieve a similarity of 75%or more when identifying two different concentrations of solutions containing a single or a mixture of targets within the linear concentration range of the targets.However,the similarity dropped to less than 25%when identifying two solutions of different substances.The proposed method had excellent recognition abilityof targets.The proposed detector and method combined fluorescence and absorption spectroscopy,which could expand the application of spectroscopy in the in situ rapid identification and detection of pollutants such as PAHs in surface water.

Result Analysis
Print
Save
E-mail