1.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
2.Localization of the sternocleidomastoid muscle in cervical vestibular evoked myogenic potential experiments in mice
Zhong-cheng XING ; Yong-chao XING ; Xuan-yi LI ; Wen LIU
Journal of Regional Anatomy and Operative Surgery 2025;34(2):163-165
Objective The experimental method of cervical vestibular evoked myogenic potential(cVEMP)with high retest reliability was designed to verify the accuracy of locating sternocleidomastoid muscle in mice.Methods Three 2-month-old ICR male mice were selected,one of which was dissected to locate the sternocleidomastoid muscle,while the other two were used to design the experimental plan to verify the accuracy of localization.Results The recording electrode positioned on the sternocleidomastoid muscle of mice can repeatedly elicit clear cVEMP waveform.Conclusion The cVEMP waveform with high retest reliability can be measured in both experimental mice,suggesting that the localization of sternocleidomastoid muscle in this research is accurate.
3.2024 annual report of interventional treatment for heart failure
Chang-dong ZHANG ; Yu-cheng ZHONG ; Geng LI ; Jie WU ; Jun TIAN ; Zhi-cheng JING ; Wei MA ; Nian-guo DONG ; Yong-jian WU ; Da-xin ZHOU ; Xiao-ke SHANG
Chinese Journal of Interventional Cardiology 2025;33(10):581-587
China has become the country with the highest global burden of heart failure(HF).Despite the widespread use of prognostic-improving medications today,the mortality rate of HF remains high,reaching 13.7%at one year-particularly among patients with heart failure with reduced ejection fraction(HFrEF).HF interventional device therapy(structural intervention)targets the structural factors underlying HF,including atrial pressure,ventricular remodeling,and valvular intervention.It leverages the heart's intrinsic physiological properties and pathological progression mechanisms to deliver treatments through interventions without external active forces,achieving anatomical or functional repair.This field has emerged as a rapidly growing area and plays an increasingly critical role in HF management.This article provides a comprehensive review and summary of the latest advancements in HF and cardiomyopathy interventional therapy over the past year.It covers various novel technologies and products currently in the research phase,aiming to provide an in-depth analysis of the current status and future directions of HF interventional therapy,and further advance the development of this discipline.
4.Research progress in reactivation factors and prevention of retinopathy of prematurity after anti-VEGF therapy
Yusheng ZHONG ; Jianhong LIANG ; Xiaoxin LI ; Yong CHENG
Chinese Journal of Experimental Ophthalmology 2025;43(8):761-765
The intravitreal injection of anti-vascular endothelial growth factor (VEGF) agents is currently the first-line therapy for retinopathy of prematurity (ROP) in clinical practice.This therapy has several advantages, including ease of operation, rapid onset of action, and minimal adverse reactions.However, the high reactivation rate observed in clinical applications limits its utility.Understanding reactivation characteristics is crucial for patient management and clinical trial design.The International Classification of Retinopathy of Prematurity (Third edition) updated the definition of reactivation and related concepts.This article summarizes the clinical manifestations and mechanisms of ROP reactivation after anti-VEGF therapy in recent studies and analyzes high-risk factors associated with reactivation, including those related to the infant, the disease, and the medication.The goal is to provide guidance for the early identification, prevention, and intervention in clinical practice.Nevertheless, significant clinical controversies remain regarding the prevention and retreatment of ROP reactivation.Future research should accumulate more evidence-based medical data and conduct large-scale prospective studies to further standardize diagnostic and treatment processes.
5.2024 annual report of interventional treatment for heart failure
Chang-dong ZHANG ; Yu-cheng ZHONG ; Geng LI ; Jie WU ; Jun TIAN ; Zhi-cheng JING ; Wei MA ; Nian-guo DONG ; Yong-jian WU ; Da-xin ZHOU ; Xiao-ke SHANG
Chinese Journal of Interventional Cardiology 2025;33(10):581-587
China has become the country with the highest global burden of heart failure(HF).Despite the widespread use of prognostic-improving medications today,the mortality rate of HF remains high,reaching 13.7%at one year-particularly among patients with heart failure with reduced ejection fraction(HFrEF).HF interventional device therapy(structural intervention)targets the structural factors underlying HF,including atrial pressure,ventricular remodeling,and valvular intervention.It leverages the heart's intrinsic physiological properties and pathological progression mechanisms to deliver treatments through interventions without external active forces,achieving anatomical or functional repair.This field has emerged as a rapidly growing area and plays an increasingly critical role in HF management.This article provides a comprehensive review and summary of the latest advancements in HF and cardiomyopathy interventional therapy over the past year.It covers various novel technologies and products currently in the research phase,aiming to provide an in-depth analysis of the current status and future directions of HF interventional therapy,and further advance the development of this discipline.
7.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
8.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
9.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
10.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures

Result Analysis
Print
Save
E-mail