1.Pre-operative risk assessment of hepatocellular carcinoma recurrence in liver transplant recipients by non-invasive detection of pre-existing genetic lesions
Suqin YANG ; Sunbin LING ; Jianhua LI ; Yan WANG ; Jiapei WANG ; Qiwei HUANG ; Fanming LIU ; Yiqi ZHUANG ; Yingyu ZHENG ; Rui WANG ; Zhe YANG ; Xiaoping ZHENG ; Kai WANG ; Zhikun LIU ; Jun CHEN ; Jianguo WANG ; Haiyang XIE ; Lin ZHOU ; Leiming CHEN ; Guoqiang CAO ; Dandan CHEN ; Junfang JI ; Bin ZHAO ; Chao JIANG ; Di LU ; Xuyong WEI ; Hangjin JIANG ; Qiaonan SHAN ; Hengbo SHI ; Yong-Zhen XU ; Shusen ZHENG ; Zhengxin WANG ; Shengda LIN ; Xiao XU
Clinical and Molecular Hepatology 2026;32(2):884-903
Background/Aims:
Liver transplantation (LT) following total hepatectomy is a life-saving treatment for hepatocellular carcinoma (HCC). The HCC recurrence after LT hinders the effectiveness of the procedure. The objective of this study is to develop a pre-operative risk stratification model based on a liquid biopsy.
Methods:
We conducted a comprehensive multi-omics study of 260 HCC patients from three centers, including clinical data, low-coverage whole-genome sequencing of cell-free DNA (cfDNA) from plasma, as well as whole-exome, single-nucleus RNA, and spatial transcriptomics from matched tumor and non-tumor tissues.
Results:
We identified cfDNA-derived copy number alteration (CNA) signatures associated with post-transplant recurrence. By integrating cfDNA-derived CNA profiles with single-cell transcriptomic data, we traced recurrence-associated cfDNA to a distinct subpopulation of malignant cells within the primary tumor. These cells were embedded in a pro-metastatic microenvironment of specialized endothelial subtypes and cancer-associated fibroblasts. Notably, most recurrence-associated lesions were detectable in cfDNA prior to liver transplantation (LT). Building on these insights, we developed the ZJU Criteria based on CNA fragments and tumor markers, a pre-LT risk prediction tool that integrates conventional clinical factors with cfDNA-derived CNA signatures, and validated it using internal and independent external cohorts.
Conclusion
Our findings suggest that post-transplant recurrence commonly originates from advanced subclones that emerge late during tumor evolution. The ZJU Criteria provides an accurate, non-invasive strategy that significantly improves pre-LT risk stratification and clinical decision-making for patients with HCC.
2.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
3.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
4.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
5.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
6.Surgical outcomes and prognostic analysis of congenital cervicothoracic scoliosis with Klippel-Feil syndrome
Kai SUN ; Saihu MAO ; Song LI ; Jie ZHOU ; Benlong SHI ; Jun QIAO ; Zhen LIU ; Yong QIU ; Zezhang ZHU ; Xu SUN
Chinese Journal of Surgery 2025;63(5):396-405
Objective:To investigate the surgical outcomes of congenital cervicothoracic scoliosis (CTS) patients with Klippel-Feil syndrome (KFS) and prognostic characteristics across different subtypes.Methods:A retrospective case series study is conducted. Clinical and radiographic data of 41 CTS patients with KFS who underwent hemivertebra resection with instrumentation at Department of Orthopedic Surgery, Nanjing Drum Tower Hospital from March 2012 to September 2022, with a minimum follow-up of two years, were analyzed. The cohort included 16 males and 25 females, aged (8.6±3.7) years (range: 3 to 15 years). Preoperative, immediate postoperative, and final follow-up cervicothoracic deformity parameters were compared. Patients were classified into three subtypes based on preoperative coronal alignment: shoulder-neck type (type A, 16 cases), trunk-tilt type (type B, 16 cases), and thoracic compensatory curve type (type C, 9 cases). The severity of KFS and the incidence of distal curve progression among subtypes were analyzed. Repeated measurement data were compared by repeated measurement ANOVA, pairwise comparison within groups was performed by Bonferroni method, and categorical variables were compared by Chi-square test or Fisher exact probability method.Results:All patients underwent successful surgery. Twenty-one patients (53.7%) had cervical fusion of ≥3 segments, and 63.1% (82/130) of fused cervical segments were located proximally to the instrumentation. Postoperative cervicothoracic Cobb angle, head tilt, head shift, neck tilt, and clavicle angle significantly improved (all P<0.05). The proportion of patients with cervical fusion of ≥3 segments was higher in types B and C (17/25) than that in type A (5/16) ( χ2=5.299, P=0.021). Four type B (4/16) and 5 type C (5/9) patients underwent long-segment fixation, with stable coronal alignment postoperatively. The remaining patients received short-segment fixation. In the short-segment group, the incidence of distal curve progression was significantly higher in types B and C (8/16) than that in type A (1/16) ( P=0.015). Ultimately, 3 type B patients underwent revision surgery, and 1 type C patient met the criteria for revision (distal compensatory thoracic or lumbar curve>40°). Conclusions:CTS patients with KFS are predisposed to develop significant coronal malalignment involving trunk tilt (type B) or thoracic compensatory curve (type C) before surgery. Following hemivertebra resection with short-segment fixation, such patients have a high risk of distal curve progression and potential need for revision surgery.
7.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
8.International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025).
Sheng-Sheng ZHANG ; Lu-Qing ZHAO ; Xiao-Hua HOU ; Zhao-Xiang BIAN ; Jian-Hua ZHENG ; Hai-He TIAN ; Guan-Hu YANG ; Won-Sook HONG ; Yu-Ying HE ; Li LIU ; Hong SHEN ; Yan-Ping LI ; Sheng XIE ; Jin SHU ; Bin-Fang ZENG ; Jun-Xiang LI ; Zhen LIU ; Zheng-Hua XIAO ; Jing-Dong XIAO ; Pei-Yong ZHENG ; Shao-Gang HUANG ; Sheng-Liang CHEN ; Gui-Jun FEI
Journal of Integrative Medicine 2025;23(5):502-518
Functional dyspepsia (FD), characterized by persistent or recurrent dyspeptic symptoms without identifiable organic, systemic or metabolic causes, is an increasingly recognized global health issue. The objective of this guideline is to equip clinicians and nursing professionals with evidence-based strategies for the management and treatment of adult patients with FD using traditional Chinese medicine (TCM). The Guideline Development Group consulted existing TCM consensus documents on FD and convened a panel of 35 clinicians to generate initial clinical queries. To address these queries, a systematic literature search was conducted across PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), VIP Database, China Biology Medicine (SinoMed) Database, Wanfang Database, Traditional Medicine Research Data Expanded (TMRDE), and the Traditional Chinese Medical Literature Analysis and Retrieval System (TCMLARS). The evidence from the literature was critically appraised using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. The strength of the recommendations was ascertained through a consensus-building process involving TCM and allopathic medicine experts, methodologists, pharmacologists, nursing specialists, and health economists, leveraging their collective expertise and empirical knowledge. The guideline comprises a total of 43 evidence-informed recommendations that span a range of clinical aspects, including the pathogenesis according to TCM, diagnostic approaches, therapeutic interventions, efficacy assessments, and prognostic considerations. Please cite this article as: Zhang SS, Zhao LQ, Hou XH, Bian ZX, Zheng JH, Tian HH, Yang GH, Hong WS, He YY, Liu L, Shen H, Li YP, Xie S, Shu J, Zeng BF, Li JX, Liu Z, Xiao ZH, Xiao JD, Zheng PY, Huang SG, Chen SL, Fei GJ. International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025). J Integr Med. 2025; 23(5):502-518.
Dyspepsia/drug therapy*
;
Humans
;
Medicine, Chinese Traditional/methods*
;
Practice Guidelines as Topic
;
Drugs, Chinese Herbal/therapeutic use*
9.Associations between Pesticide Metabolites and Decreased Estimated Glomerular Filtration Rate Among Solar Greenhouse Workers: A Specialized Farmer Group.
Teng Long YAN ; Xin SONG ; Xiao Dong LIU ; Wu LIU ; Yong Lan CHEN ; Xiao Mei ZHANG ; Xiang Juan MENG ; Bin Shuo HU ; Zhen Xia KOU ; Tian CHEN ; Xiao Jun ZHU
Biomedical and Environmental Sciences 2025;38(2):265-269
10.Risk prediction of Reduning Injection batches by near-infrared spectroscopy combined with multiple machine learning algorithms.
Wen-Yu JIA ; Feng TONG ; Heng-Xu LIU ; Shu-Qin JIN ; Yong-Chao ZHANG ; Chen-Feng ZHANG ; Zhen-Zhong WANG ; Xin ZHANG ; Wei XIAO
China Journal of Chinese Materia Medica 2025;50(2):430-438
In this paper, near-infrared spectroscopy(NIRS) was employed to analyze 129 batches of commercial products of Reduning Injection. The batch reporting rate was estimated according to the report of Reduning Injection in the direct adverse drug reaction(ADR) reporting system of the drug marketing authorization holder of the Center for Drug Reevaluation of the National Medical Products Administration(National Center for ADR Monitoring) from August 2021 to August 2022. According to the batch reporting rate, the samples of Reduning Injection were classified into those with potential risks and those being safe. No processing, random oversampling(ROS), random undersampling(RUS), and synthetic minority over-sampling technique(SMOTE) were then employed to balance the unbalanced data. After the samples were classified according to appropriate sampling methods, competitive adaptive reweighted sampling(CARS), successive projections algorithm(SPA), uninformative variables elimination(UVE), and genetic algorithm(GA) were respectively adopted to screen the features of spectral data. Then, support vector machine(SVM), logistic regression(LR), k-nearest neighbors(KNN), naive bayes(NB), random forest(RF), and artificial neural network(ANN) were adopted to establish the risk prediction models. The effects of the four feature extraction methods on the accuracy of the models were compared. The optimal method was selected, and bayesian optimization was performned to optimize the model parameters to improve the accuracy and robustness of model prediction. To explore the correlations between potential risks of clinical use and quality test data, TreeNet was employed to identify potential quality parameters affecting the clinical safety of Reduning Injection. The results showed that the models established with the SVM, LR, KNN, NB, RF, and ANN algorithms had the F1 scores of 0.85, 0.85, 0.86, 0.80, 0.88, and 0.85 and the accuracy of 88%, 88%, 88%, 85%, 91%, and 88%, respectively, and the prediction time was less than 5 s. The results indicated that the established models were accurate and efficient. Therefore, near infrared spectroscopy combined with machine learning algorithms can quickly predict the potential risks of clinical use of Reduning Injection in batches. Three key quality parameters that may affect clinical safety were identified by TreeNet, which provided a scientific basis for improving the safety standards of Reduning Injection.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/administration & dosage*
;
Machine Learning
;
Algorithms
;
Humans
;
Quality Control

Result Analysis
Print
Save
E-mail