1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Controllability Analysis of Structural Brain Networks in Young Smokers
Jing-Jing DING ; Fang DONG ; Hong-De WANG ; Kai YUAN ; Yong-Xin CHENG ; Juan WANG ; Yu-Xin MA ; Ting XUE ; Da-Hua YU
Progress in Biochemistry and Biophysics 2025;52(1):182-193
ObjectiveThe controllability changes of structural brain network were explored based on the control and brain network theory in young smokers, this may reveal that the controllability indicators can serve as a powerful factor to predict the sleep status in young smokers. MethodsFifty young smokers and 51 healthy controls from Inner Mongolia University of Science and Technology were enrolled. Diffusion tensor imaging (DTI) was used to construct structural brain network based on fractional anisotropy (FA) weight matrix. According to the control and brain network theory, the average controllability and the modal controllability were calculated. Two-sample t-test was used to compare the differences between the groups and Pearson correlation analysis to examine the correlation between significant average controllability and modal controllability with Fagerström Test of Nicotine Dependence (FTND) in young smokers. The nodes with the controllability score in the top 10% were selected as the super-controllers. Finally, we used BP neural network to predict the Pittsburgh Sleep Quality Index (PSQI) in young smokers. ResultsThe average controllability of dorsolateral superior frontal gyrus, supplementary motor area, lenticular nucleus putamen, and lenticular nucleus pallidum, and the modal controllability of orbital inferior frontal gyrus, supplementary motor area, gyrus rectus, and posterior cingulate gyrus in the young smokers’ group, were all significantly different from those of the healthy controls group (P<0.05). The average controllability of the right supplementary motor area (SMA.R) in the young smokers group was positively correlated with FTND (r=0.393 0, P=0.004 8), while modal controllability was negatively correlated with FTND (r=-0.330 1, P=0.019 2). ConclusionThe controllability of structural brain network in young smokers is abnormal. which may serve as an indicator to predict sleep condition. It may provide the imaging evidence for evaluating the cognitive function impairment in young smokers.
3.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
4.Analysis and application thinking of standards for 500 kinds of traditional Chinese medicine formula granules on base of industrial practice.
Yong LIU ; Jun ZHANG ; Xin-Hai DONG ; Lin ZHOU ; Dong-Mei SUN ; Fu-Lin MAO ; Zhen-Yu LI ; Lei HUANG ; Jin-Lai LIU
China Journal of Chinese Materia Medica 2025;50(5):1427-1436
Following the release of the Technical Requirements on Quality Control and Standard Establishment of Traditional Chinese Medicine Formula Granules by the National Medical Products Administration in 2021, Chinese Pharmacopoeia Commission has promulgated 296 national drug standards so far, and most provinces have started the work of establishing provincial standards as supplements. The promulgation of standards fostered high-quality development of the industry. Since the implementation of national and provincial standards for more than three years, enterprises have gained deep understanding and hands-on experiences on the characteristics, technical requirements, production process, and quality control of traditional Chinese medicine(TCM) formula granules. Meanwhile, challenges have emerged restricting the high-quality development of this industry, including how to formulate quality control strategies for medicinal materials and decoction pieces, how to reduce manufacturing costs, and how to improve the pass rate and product stability under high standards. Based on the work experiences from standard management and process research, this article analyzed the distribution of sources, processing methods, dry extract rate ranges, process requirements for volatile oil-containing decoction pieces, control measures of safety indices, characteristics and trends of setting characteristic chromatograms or fingerprints, characteristics and trends of setting content ranges, and main differences between national standards and provincial standards. On the one hand, this article aims to present main characteristics for deeply understanding different indicators in standards and provide basic ideas for establishing quality and process control systems. On the other hand, from the perspective of industrial practice, suggestions are put forward on the important aspects that need to be focused on in the quality and process control of TCM formula granules.
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Medicine, Chinese Traditional/standards*
;
China
;
Drug Industry/standards*
5.Phenylpropanoids from roots of Berberis polyantha.
Dong-Mei SHA ; Shuai-Cong NI ; Li-Niu SHA-MA ; Hai-Xiao-Lin-Mo MA ; Xiao-Yong HE ; Bin HE ; Shao-Shan ZHANG ; Ying LI ; Jing WEN ; Yuan LIU ; Xin-Jia YAN
China Journal of Chinese Materia Medica 2025;50(6):1564-1568
The chemical constituents were systematically separated from the roots of Berberis polyantha by various chromatographic methods, including silica gel column chromatography, HP20 column chromatography, polyamide column chromatography, reversed-phase C_(18) column chromatography, and preparative high-performance liquid chromatography. The structures of the compounds were identified by physicochemical properties and spectroscopic techniques(1D NMR, 2D NMR, UV, MS, and CD). Four phenylpropanoids were isolated from the methanol extract of the roots of B. polyantha, and they were identified as(2R)-1-(4-hydroxy-3,5-dimethoxyphenyl)-1-propanone-O-β-D-glucopyranoside(1), methyl 4-hydroxy-3,5-dimethoxybenzoate(2),(+)-syringaresinol(3), and syringaresinol-4-O-β-D-glucopyranoside(4). Compound 1 was a new compound, and other compounds were isolated from this plant for the first time. The anti-inflammatory activity of these compounds was evaluated based on the release of nitric oxide(NO) in the culture of lipopolysaccharide(LPS)-induced RAW264.7 macrophages. At a concentration of 10 μmol·L~(-1), all the four compounds inhibited the LPS-induced release of NO in RAW264.7 cells, demonstrating potential anti-inflammatory properties.
Plant Roots/chemistry*
;
Animals
;
Mice
;
Berberis/chemistry*
;
RAW 264.7 Cells
;
Macrophages/immunology*
;
Drugs, Chinese Herbal/isolation & purification*
;
Nitric Oxide/metabolism*
;
Molecular Structure
;
Anti-Inflammatory Agents/isolation & purification*
6.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
7.Comparison of side-opening and front-opening approach bone cement injectors in percutaneous kyphoplasty for thoracolumbar osteoporotic vertebral compression fractures.
Wei-Xin DONG ; Zhen-Tao CHU ; Yong HU ; Ou-Jie LAI ; Zhen-Shan YUAN ; Xiao-Yang SUN
China Journal of Orthopaedics and Traumatology 2025;38(2):128-133
OBJECTIVE:
To compare clinical efficacy between side-opening and front-opening bone cement injectors in percutaneous kyphoplasty(PKP) for the management of thoracolumbar osteoporotic vertebral compression fractures(OVCFs).
METHODS:
A retrospective cohort study was conducted, comprising 62 patients with single-segment thoracolumbar OVCFs (T11-L2), who underwent bilateral PKP at our department during the period from June 2020 to October 2021. Patients were categorized into two groups based on the specific bone cement injector employed during the surgical procedure: the side-opening group (n=29) and the front-opening group (n=33). Among them, the side-opening group consisted of 6 male and 23 female patients, with a mean age of (73.32±9.11) years. The front-opening group included 7 male and 26 female patients, with a mean age of (71.29±10.39) years. The variables encompassed essential patient characteristics were recorded, such as gender, age, bone mineral density (BMD), and fracture level (T11-L2), as well as procedural aspects, including operation duration, cement injection volume, cement distribution type (lobular or diffuse), occurrence of cement leakage, pre-and post-operative visual analogue scale (VAS) pain scores, and vertebral compression ratio.
RESULTS:
All patients underwent successful surgery, with a mean follow-up duration of (15.37±3.03) months. There were no statistically significant differences in gender, age, BMD, fracture level, preoperative vertebral compression degree, and VAS scores between the side-opening group and the front-opening group (P>0.05). The operation time, the mean cement injection volumes, the distribution of bone cement within the vertebrae has no statistically significant difference between two groups(P>0.05). Both the side-opening and front-opening groups showed significant improvements in VAS scores at 3 days and 6 months after operation (P<0.05). However, there was no significant difference in VAS scores between the two groups at both 3 days and 6 months after the operation (P>0.05).
CONCLUSION
Side-opening bone cement injectors in bilateral PKP surgery for single-segment thoracolumbar OVCF achieve similar clinical efficacy as front-opening injectors, without significant improvement in cement distribution and containment.
Humans
;
Female
;
Male
;
Kyphoplasty/instrumentation*
;
Aged
;
Bone Cements
;
Fractures, Compression/surgery*
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Thoracic Vertebrae/injuries*
;
Lumbar Vertebrae/injuries*
;
Osteoporotic Fractures/surgery*
;
Middle Aged
;
Aged, 80 and over
8.Molecular Biological Analysis of ABO Blood Group Ael and Bel Subtype.
Xin LIU ; Ying XIE ; Shu-Ling DONG ; Shu-Ya WANG ; Yong-Kui KONG
Journal of Experimental Hematology 2025;33(5):1422-1428
OBJECTIVE:
The molecular biology of alleles of ABO blood group Ael and Bel subtype from two samples was analyzed to explore the effect of mutations on the structure of glycosyltransferase.
METHODS:
The ABO phenotypes were identified by serological techniques, then exons 6 and 7 of ABO gene were amplified and sequenced, combined with haplotype analysis to determine the genotypes. Finally, homology modeling of the mutated A/B glycosyltransferase were conducted by Modeller software and the effect of mutations on the spatial structure was analyzed by PyMol software.
RESULTS:
The serological phenotypes of the two samples were Ael and Bel, and their genotypes were ABO*AW.37/ABO*O.01.01 and ABO*BEL.03/ABO*O.01.01, respectively. The three-dimensional structure modeling of the protein showed that, compared to the wild-type glycosyltransferase, two hydrogen bonds between the side chain of p.Glu314 and surrounding amino acid disappeared in the p.Lys314Glu mutant GTA; the hydrogen bonds between the side chain of p.Trp168 and surrounding amino acid also disappeared, and the hydrogen bond between the main chain of p.Trp168 and p.Gly165 was shortened to 3.3 Å in the p.Arg168Trp mutant GTB.
CONCLUSION
Mutations in exon 7 of ABO gene c.940A>G and c.502C>T are keys to the formation of AW.37 and BEL.03 alleles, resulting in decreased expression of A and B antigens, respectively.
ABO Blood-Group System/classification*
;
Humans
;
Genotype
;
Mutation
;
Alleles
;
Glycosyltransferases/genetics*
;
Exons
;
Haplotypes
;
Phenotype
;
Models, Molecular
9.Performance assessment of computed tomographic angiography fractional flow reserve using deep learning: SMART trial summary.
Wei ZHANG ; You-Bing YIN ; Zhi-Qiang WANG ; Ying-Xin ZHAO ; Dong-Mei SHI ; Yong-He GUO ; Zhi-Ming ZHOU ; Zhi-Jian WANG ; Shi-Wei YANG ; De-An JIA ; Li-Xia YANG ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(9):793-801
BACKGROUND:
Non-invasive computed tomography angiography (CTA)-based fractional flow reserve (CT-FFR) could become a gatekeeper to invasive coronary angiography. Deep learning (DL)-based CT-FFR has shown promise when compared to invasive FFR. To evaluate the performance of a DL-based CT-FFR technique, DeepVessel FFR (DVFFR).
METHODS:
This retrospective study was designed for iScheMia Assessment based on a Retrospective, single-center Trial of CT-FFR (SMART). Patients suspected of stable coronary artery disease (CAD) and undergoing both CTA and invasive FFR examinations were consecutively selected from the Beijing Anzhen Hospital between January 1, 2016 to December 30, 2018. FFR obtained during invasive coronary angiography was used as the reference standard. DVFFR was calculated blindly using a DL-based CT-FFR approach that utilized the complete tree structure of the coronary arteries.
RESULTS:
Three hundred and thirty nine patients (60.5 ±10.0 years and 209 men) and 414 vessels with direct invasive FFR were included in the analysis. At per-vessel level, sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of DVFFR were 94.7%, 88.6%, 90.8%, 82.7%, and 96.7%, respectively. The area under the receiver operating characteristics curve (AUC) was 0.95 for DVFFR and 0.56 for CTA-based assessment with a significant difference (P < 0.0001). At patient level, sensitivity, specificity, accuracy, PPV and NPV of DVFFR were 93.8%, 88.0%, 90.3%, 83.0%, and 95.8%, respectively. The computation for DVFFR was fast with the average time of 22.5 ± 1.9 s.
CONCLUSIONS
The results demonstrate that DVFFR was able to evaluate lesion hemodynamic significance accurately and effectively with improved diagnostic performance over CTA alone. Coronary artery disease (CAD) is a critical disease in which coronary artery luminal narrowing may result in myocardial ischemia. Early and effective assessment of myocardial ischemia is essential for optimal treatment planning so as to improve the quality of life and reduce medical costs.
10.Prediction of gastric cancer T staging using oral contrast-enhanced ultrasonography combined with contrast-enhanced CT
Aiqing LU ; Fei QIU ; Xin DONG ; Xiaoyan LI ; Xiuyun SUN ; Xuefeng LI ; Zhaoxin JIN ; Xiankai WANG ; Yong ZHANG
Chinese Journal of Radiological Health 2025;34(3):368-372
Objective To explore the value of oral contrast-enhanced ultrasonography (OCEUS) combined with contrast-enhanced CT in predicting preoperative T staging in patients with gastric cancer. Methods A retrospective analysis was conducted on 80 patients with gastric cancer confirmed via endoscopic biopsy or postoperative pathology at the First People’s Hospital of Jining from January 2021 to November 2024. The cohort included 56 males and 24 females, aged 38-79 years, with a median age of 55.9 years. All patients underwent both OCEUS and contrast-enhanced CT within one week prior to surgery. T staging of gastric cancer was determined using OCEUS, contrast-enhanced CT, or their combination. The results were compared with pathological T staging, and statistical differences in accuracy were analyzed. Results Pathological T staging identified T1 in 9 cases, T2 in 16 cases, T3 in 42 cases, and T4 in 13 cases. OCEUS indicated T1 in 6 cases, T2 in 14 cases, T3 in 50 cases, and T4 in 10 cases, with an accuracy rate of 80.0%. Contrast-enhanced CT indicated T1 in 4 cases, T2 in 12 cases, T3 in 52 cases, and T4 in 12 cases, with an accuracy rate of 75.0%. The combination of OCEUS and contrast-enhanced CT indicated T1 in 6 cases, T2 in 15 cases, T3 in 47 cases, and T4 in 12 cases, with an accuracy rate of 87.5%. The combined approach demonstrated significantly higher accuracy in preoperative T staging compared to either method alone (P < 0.05). Conclusion The combination of OCEUS and contrast-enhanced CT improves the accuracy of preoperative T staging in gastric cancer patients, providing valuable support for their diagnosis and treatment.

Result Analysis
Print
Save
E-mail