1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Evaluation of cardiac involvement in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis using echocardiography combined with electrocardiography
Aiqing LU ; Ling CHEN ; Xiuyun SUN ; Xin DONG ; Xiaoyan LI ; Yongcun SUN ; Shaowen LYU ; Long YU ; Yong ZHANG
Chinese Journal of Radiological Health 2025;34(4):534-539
Objective To evaluate cardiac involvement in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis (AAV) using echocardiography combined with electrocardiography. Methods A retrospective analysis was performed on the detailed medical records of AAV patients treated in Jining First People’s Hospital between January 2020 and December 2024. Eighty patients were enrolled in the AAV group, and the risk of heart disease was compared between the AAV group and a control group with 80 subjects matched for age, sex, and cardiovascular disease risk factors. Results Electrocardiographic abnormalities were observed in 78.75% of patients in the AAV group, while significant electrocardiographic abnormalities only occurred in symptomatic patients in the control group. There were no differences in left atrial enlargement or interventricular septal thickening between the AAV group and the control group. The overall left ventricular systolic function in the AAV group was lower than that in the control group (8.75% vs. 0). The incidence of reduced diastolic function in the AAV group was significantly higher than that in the control group (37.5% vs. 15%). The incidence rates of tricuspid regurgitation, mitral regurgitation, aortic regurgitation, and pericardial effusion in the AAV group were significantly higher than those in the control group. Pericardial thickening, aortic stenosis, pulmonary hypertension, and rare periaortic granulomas were found in the AAV group, but not in the control group. Conclusion Echocardiography and electrocardiography are important examination methods for evaluating cardiac involvement in AAV. These methods have key roles in disease screening, diagnosis and treatment, follow-up, and prognosis judgment.
3.Qihuang needle therapy for autism spectrum disorder with sleep disorder: a multi-center randomized controlled trial.
Bingxu JIN ; Qizhen LIU ; Jiahao TANG ; Yong ZHAO ; Jing XIN ; Yuan ZHOU ; Haiyan CAI ; Zhanxin HUO ; Xiaohong CHEN ; Yan BAI
Chinese Acupuncture & Moxibustion 2025;45(3):322-326
OBJECTIVE:
To observe the clinical efficacy of Qihuang needle therapy for autism spectrum disorder (ASD) children with sleep disorder.
METHODS:
A total of 60 ASD children with sleep disorder were randomly divided into an observation group and a control group, 30 cases in each group. Both groups were treated with structured education intervention, 60 min each time, once a day, 6 times a week. Qihuang needle therapy was applied at Yintang (GV24+), Baihui (GV20) and bilateral Jueyinshu (BL14), Xinshu (BL15) in the observation group, multi-direction needling was delivered and without needle retaining. The treatment was given 2 times a week, each treatment was delivered at interval of 2 days at least. Behavioral intervention was adopted in the control group. Treatment for consecutive 12 weeks was required in both groups. Before and after treatment, the scores of children's sleep habits questionnaire (CSHQ), the autism behavior checklist (ABC), the childhood autism rating scale (CARS), and the childhood autism behavior scale (CABS) were observed in the two groups.
RESULTS:
After treatment, the scores of CSHQ, ABC, CARS and CABS were decreased compared with those before treatment (P<0.01), and the above scores in the observation group were lower than those in the control group (P<0.05).
CONCLUSION
Qihuang needle therapy can effectively treat ASD with sleep disorder, improve the core symptoms of ASD and the sleep quality.
Humans
;
Autism Spectrum Disorder/physiopathology*
;
Male
;
Female
;
Child
;
Sleep Wake Disorders/physiopathology*
;
Child, Preschool
;
Acupuncture Therapy
;
Acupuncture Points
;
Treatment Outcome
;
Sleep
;
Needles
4.Effect of miR-129-3p mimetic on bone loss in tail-suspended mice
Yi WU ; Zi-dong AN ; Yong-jie PANG ; Li-qiang WANG ; Xin-yang WANG ; Yu-hai GAO ; Xue-yan LI ; Ke-ming CHEN
Chinese Pharmacological Bulletin 2025;41(4):703-709
Aim To study whether intravenous injec-tion of miR-129-3p mimetic(agomir)can resist bone loss caused by hind limb disuse,and to provide new i-deas for preventing bone loss in microgravity environ-ment.Methods Forty-eight C57BL/6J male mice were randomly divided into the control group(CON),tail suspension model group(TS),tail suspension+miR-129-3p agomir administration group(miRNA)and tail suspension+miR-129-3p negative sequence agomir control group(NC).The miRNA group was given 4 mg·kg-1 miR-129-3p agomir by intravenous injection into the medial canthus twice a week.The NC agomir group were consistent with those in the miR-129-3p agomir group,and the CON and TS groups were given only equal volumes of normal saline.After four weeks,all mice were sacrificed and samples were collected.Micro-CT scan of femur,three-point femur bending test,serum bone metabolism index detection,oxidative stress index detection and osteogenesis-related protein expression analysis in bone tissue were per-formed.Results After four weeks,the number of tra-becular bone in the TS group was significantly re-duced,and Tb.BMD,Tb.Th,Tb.N,Tb.BS/TV and Tb.BV/TV were significantly lower than those in the CON group(P<0.01).While Tb.Sp TS group was significantly higher than the CON group(P<0.05),the maximum load and flexural strength of the femur significantly decreased(P<0.01),the content of ser-um bone formation index PINP was significantly lower than that of the CON group(P<0.01),and the con-tent of bone resorption index CTX-I was significantly higher than that of the CON group(P<0.01),the content of serum oxidative damage indexes 8-iso-PGF2α and 8-OHdG significantly increased(P<0.01),and the expression of osteogenesis-related pro-teins in bone tissue markedly decreased(P<0.01).However,the increase or decrease of all indexes in miRNA group was significantly lower than that in TS group.Conclusions miR-129-3p mimetic can signifi-cantly reduce bone loss caused by hind limb disuse.This experiment provides a new idea and method for preventing bone loss in microgravity environment.
5.Establishment and preliminary testing of a double antibody sandwich ELISA method for Brucella detection
Meng-xin YAO ; Ze-yu PENG ; Wen-hao REN ; Yi-mei XU ; Wei GUO ; Chuang-fu CHEN ; Zhong-chen MA ; Yong WANG
Chinese Journal of Zoonoses 2025;41(3):255-262
This study was aimed at establishing a sensitive and specific sandwich ELISA detection method for Brucella.We screened monoclonal capture antibodies and detection antibodies for Brucella detection,and optimized and determined the opti-mal antibody coating time and concentration,as well as the optimal blocking solution,blocking time,and yin-yang critical val-ue.The specificity of this method was verified by examination of other bacteria prone to cross-reacting with Brucella.The sen-sitivity of the method was verified by detection of a gradient dilution of inactivated Brucella.Moreover,the sandwich ELISA detection results were compared with test tube agglutination and qPCR results.The selected capture antibody was 4A12,and the selected detection antibody was 6C12.Experimental analysis indicated that the optimal coating concentration for the 4A12 capture antibody was 5 μg/mL,and the optimal dilution ratio for the 6C12 detection antibody was 1∶2000.The optimal coating conditions were overnight at 4℃,and blocking with 5%skim milk powder for 2 hours.The established double antibody sand-wich ELISA method reacted with only Brucella but not other bacteria,thus demonstrating the method's good specificity.Inac-tivated Brucella solution was still detectable after dilution to 1 × 105 CFU/mL,thus demonstrating the method's good sensitiv-ity.The intra-and inter batch coefficients of variation were both below 10%,thus indicating the method's good repeatability.Thus,this study successfully established a dual antibody sandwich ELISA method for Brucella detection,which has good spe-cificity and sensitivity,and might provide an effective approach for the precise diagnosis and effective prevention and control of brucellosis.
6.Assessment of the severity of knee osteoarthritis based on the global fat fraction histogram of the infrapatellar fat pad
Baogen ZHAO ; Yujin ZHANG ; Xin CHEN ; Xiaoying WANG ; Gang JI ; Yong WANG ; Li ZHANG
Journal of Practical Radiology 2025;41(11):1838-1841,1856
Objective To investigate the relationship between quantitative parameters of the histogram of global fat fraction(FF)in the infrapatellar fat pad(IPFP)and the severity of knee osteoarthritis(KOA).Methods A total of 120 patients were prospectively selected and divided into the non-KOA group(KL grade 0-1),the mild KOA group(KL grade 2),and the severe KOA group(KL grade 3-4)based on the Kellgren-Lawrence(KL)classification criteria of knee X-rays.The FF maps of the IPFP were obtained based on the mDIXON-Quant technique.The region of interest(ROI)was delineated using 3D Slicer software,and global histogram analysis was performed to obtain quantitative parameters,including mean,median,10th percentile(10th),90th percentile(90th),skewness,kurtosis,and entropy.Pearson or Spearman correlation analysis was used to evaluate the correlation between each quanti-tative parameter and the severity of KOA.The diagnostic efficacy was analyzed using the receiver operating characteristic(ROC)curves.Results As the progression of KL classification,the mean,median,percentiles,and kurtosis of the global FF histogram quantitative parameters in the IPFP decreased,while skewness and entropy increased,with statistically significant among the three groups(P<0.001).The mean,median,10th,90th,and kurtosis showed negative correlations with the KL classification(r=-0.563,-0.448,-0.614,-0.294,-0.450),while skewness and entropy showed positive correlations with the KL classification(r=0.385,0.637),all of which were statistically significant(P<0.05).The area under the curve(AUC)for diagnosing KOA were 0.799,0.725,0.828,0.636,0.741,0.688,and 0.830,respectively.The sensitivity of the 10th and entropy were 74.4%and 77.9%,respectively,and the specificity were 85.3%and 88.2%,respectively.Conclusion The quantitative parameters of the histogram of global FF in the IPFP are correlated with the severity of KOA and can reflect the pathophysiological changes in the IPFP.They can serve as objective indicators for diagnosing KOA and assessing its severity.
7.Discovery of FAM3 A-targeting Small Molecule Agents Using Integrated Virtual Screening and SPR Technology
Zi-Shuo XU ; Chao SHI ; Zhang-Xin CHEN ; Zhe-Yong XUE ; Li-Xin HUANG ; Zhen-Zhan CHANG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(11):1711-1718
Family with sequence similarity 3 member A(FAM3A),a novel mitochondrial protein,plays a pivotal role in hepatic glucose and lipid metabolism by enhancing ATP synthesis and secretion and mod-ulating the ATP-P2 receptor-Akt signaling pathway.Dysregulation of FAM3A is closely associated with the pathogenesis of non-alcoholic fatty liver disease(NAFLD)and type 2 diabetes mellitus(T2DM).In this study,targeting FAM3A as a therapeutic candidate,we conducted virtual screening to identify 47 small-molecule compounds with potential binding activity.Surface plasmon resonance(SPR)analysis re-vealed three compounds exhibiting high binding affinity to FAM3 A.Further structural characterization of the FAM3A-compound complexes,combined with intermolecular interaction analysis,elucidated the binding mode of the lead compound Index 2(taxifolin)to FAM3A at atomic resolution.These findings provide critical insights into the molecular mechanisms underlying ligand-FAM3A interactions and deliver valuable chemical scaffolds for the development of therapeutics targeting NAFLD and T2DM.This work establishes a foundation for advancing drug discovery efforts focused on FAM3A-mediated metabolic disor-ders.
8.Gastrointestinal hamartomatous inverted hyperplastic polyps: a clinicopathological analysis of ten cases
Lin MENG ; Yong GUO ; Xin ZHAO ; Ling CHEN ; Xuchun JIA ; Zengshan LI ; Liying ZHANG
Chinese Journal of Pathology 2025;54(2):142-148
Objective:To investigate the clinicopathological features, diagnosis, genetic alterations, and biological behaviors of hamartomatous inverted hyperplastic polyp (HIHP) in the gastrointestinal tract.Methods:The clinical, sonographic, endoscopic and pathologic data of 10 HIHP cases diagnosed at the First Affiliated Hospital of Air Force Medical University, Xi′an, China from January 2013 to March 2024 were collected. Their clinicopathological features and histological morphology were analyzed. The cases were further divided into 3 histologic subtypes. Follow-up information was collected to analyze the relationship between histological subtype and prognosis.Results:There were 5 males and 5 females in this cohort. The age of onset was 45-68 years, with a median age of 60.5 years. The polyp-involved sites included 2 cases in gastric fundus, 6 cases in gastric body, 1 case in gastric antrum, and 1 case in duodenum. Digestive endoscopy showed mucosal protrusion lesions in all cases, except 1 case (case 10) of shallow depression on the surface, with the maximum diameter ranging 0.5-2.5 cm. Endoscopic ultrasonography showed multilocular cystic low-density shadows, with septal enhancement (case 4). The preoperative clinical diagnosis was gastric polyp, ectopic pancreas or gastrointestinal stromal tumor. Two cases showed type 1 morphology (i.e., connected with the mucosa, with clear smooth muscle boundaries). One of them (case 10) had a clear opening to form a vase-like morphology, while the other (case 4) had no obvious opening with the surface mucosa. Three cases showed type 2 morphology (i.e., not connected with the mucosa, with clear smooth muscle boundaries). Five cases showed type 3 morphology (i.e., not connected with the mucosa, without clear smooth muscle boundaries or hyperplastic smooth muscle that separated hyperplastic glands showing lobular configuration). Among them, one case of duodenal lesions (case 9) showed gastric type gland hyperplasia and expansion, including gastric fossa, gastric fundic gland and pyloric gland, with various arrangement and combination, accompanied by smooth muscle hyperplasia. In case 10, there was leiomyomatous proliferation in the stroma. The cases 2 and 4 had atypical glandular structures and cell morphology, but immunohistochemistry showed wild-type expression pattern of p53 and a Ki-67 proliferation index of less than 1%, suggesting that it was reactive atypia secondary to inflammation. The results showed that 3 cases had different gene mutations, and no recurrent gene change was identified. All patients survived without disease during the follow-up period of 1-130 months.Conclusions:HIHP is a benign lesion and has no consistently detectable genetic alterations. The histological characteristics of gastrointestinal polyps are complex. Especially, the types 1 and 3 of HIHP have unique gross and microscopic features, which require combination of proper endoscopic sampling and histological examination to correctly classify them.
9.Interpretation of the Standard for Plastic Bottle Systems and Components for Eye Drops in the 2025 Edition of the Pharmacopoeia of the People's Republic of China
Yong SHEN ; Xiaowen BO ; Xueting LIU ; Changshuai ZHAO ; Xin WANG ; Lei CHEN
Herald of Medicine 2025;44(7):1040-1044
To provide an in-depth interpretation of the background and rationale behind the development of the standard for plastic bottle systems and components for eye drops as outlined in the 2025 edition of the Pharmacopoeia of the People's Republic of China(referred as the Chinese Pharmacopoeia),to facilitate stakeholders thorough understanding of the standard content,and to offer a strong support for its subsequent smooth implementation.Starting from the background of standard construction,an in-depth exploration was conducted into the quality control requirements for plastic bottle systems and components used for eye drops,and a detailed analysis was provided of the logic and rationale behind the establishment of quality control items.Related parties should develop product quality standards based on the general requirements of the guidelines for plastic materials and containers used in pharmaceutical packaging,taking into account the specific characteristics and practical application scenarios of plastic bottle systems and components for eye drops.The standard for plastic bottle systems and components for eye drops in the 2025 edition of the Chinese Pharmacopoeia are more scientific and flexible,which will help improve the quality of eye drop products in our country while also promoting innovation and development in the eye drop packaging industry.
10.Compensatory alignment changes of cervical and thoracic spine after correction of lumbar degenerative scoliosis
Yong CAO ; Xin LI ; Zhigang CHEN ; Honglin GU ; Shujun LYU
Chinese Journal of Tissue Engineering Research 2025;29(33):7196-7202
BACKGROUND:Compensatory changes in sagittal parameters of the cervicothoracic spine after orthopedic surgery in patients with lumbar degenerative scoliosis and their intrinsic relationship,as well as the impact of these changes on quality of life,are still lacking.OBJECTIVE:To evaluate the compensatory alignment of cervical and thoracic vertebrae after correction of lumbar degenerative scoliosis.METHODS:103 patients who underwent surgical correction of lumbar degenerative scoliosis were included in this study.Patients'demographic characteristics and spinal sagittal parameters were assessed,and prediction equations between changes in cervical sagittal parameters and lumbar deformity correction were attempted.Simultaneously,the SRS-22 scale was used to assess the quality of life of patients and to explore the relationship between the compensatory changes of the cervical and thoracic spine after correction and the patients'health-related quality of life.RESULTS AND CONCLUSION:(1)At 3 months and 2 years after surgery,all indicators of the cervical spine and thoracic spine were significantly improved compared with those before surgery(P<0.05),but there was no significant change at 3 months after surgery compared with 2 years after surgery(P>0.05).At 3 months and 2 years after surgery,the lumbar spine parameters including lumbar lordosis,C7-S1 sagittal vertical axis,and pelvic incident-lumbar lordosis had significant changes compared with those before surgery(P<0.05),but the change was not significant at 3 months after surgery compared with 2 years after surgery(P>0.05).(2)Correlation analysis showed that the lumbar lordosis was highly correlated with the C3-C7 cervical lordosis,C1-C7 cervical lordosis,C2-7 sagittal vertical axis,thoracic inlet angle,and C7-S1 sagittal vertical axis(|r|≥ 0.5,P<0.000 1).The lumbar lordosis was correlated with the thoracic kyphosis(r=-0.280).(3)Two prediction formulas were established for compensatory changes in cervical spine:cervical lordosis=0.524x,lumbar lordosis=-6.612,C2-7 sagittal vertical axis=-0.263x,and lumbar lordosis=-5.436(P<0.05,R2>0.6).(4)When postoperative C2-7 sagittal vertical axis was between 14.4 and 26.8 mm;cervical lordosis was between 9° and 41°,lumbar lordosis was between 42.7° and 68.7°,and sagittal vertical axis was between-40 and 40 mm,patients had better quality of life recovery.(5)It is indicated that significant compensatory changes in the sagittal plane of the cervical spine can be observed after correction of lumbar degenerative scoliosis.We found that each 1° increase in lumbar lordosis was associated with a corresponding increase of about 0.5° in cervical lordosis and a corresponding decrease of about 0.3 mm in the vertical axis of the C2-7 sagittal plane.Patient satisfaction was higher if compensatory changes were closer to normal sagittal plane.

Result Analysis
Print
Save
E-mail