2.Eosinophilic Cholangitis Diagnosed in a Patient with Abnormal Liver Enzymes: A Case Report
Sung Hoon CHANG ; Jun Yeol KIM ; Yong Soo SONG ; Tae Seung LEE ; Jin Ho CHOI ; Woo Hyun PAIK ; Sang Hyub LEE ; Ji Kon RYU ; In Rae CHO
Korean Journal of Pancreas and Biliary Tract 2025;30(1):19-25
It is difficult to determine a cause of bile duct stricture and dilatation. Eosinophilic cholangitis, a rare benign condition, may be one cause of bile duct stricture and dilatation. It can be evaluated using various methods of histopathology, radiographs, endoscopy, and hematologic findings. Treatment generally involves steroid therapy which can lead to improvement. This case report will discuss eosinophilic cholangitis, emphasizing that while it can easily be overlooked but should be considered in differential diagnoses.
3.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Cost-effectiveness of Fractional Flow Reserve Versus Intravascular Ultrasound to Guide Percutaneous Coronary Intervention: Results From the FLAVOUR Study
Doyeon HWANG ; Hea-Lim KIM ; Jane KO ; HyunJin CHOI ; Hanna JEONG ; Sun-ae JANG ; Xinyang HU ; Jeehoon KANG ; Jinlong ZHANG ; Jun JIANG ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Sung Gyun AHN ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Hyo-Soo KIM ; Seung-Jea TAHK ; JianAn WANG ; Tae-Jin LEE ; Bon-Kwon KOO ;
Korean Circulation Journal 2025;55(1):34-46
Background and Objectives:
The Fractional Flow Reserve and Intravascular UltrasoundGuided Intervention Strategy for Clinical Outcomes in Patients with Intermediate Stenosis (FLAVOUR) trial demonstrated non-inferiority of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) compared with intravascular ultrasound (IVUS)-guided PCI. We sought to investigate the cost-effectiveness of FFR-guided PCI compared to IVUS-guided PCI in Korea.
Methods:
A 2-part cost-effectiveness model, composed of a short-term decision tree model and a long-term Markov model, was developed for patients who underwent PCI to treat intermediate stenosis (40% to 70% stenosis by visual estimation on coronary angiography).The lifetime healthcare costs and quality-adjusted life-years (QALYs) were estimated from the healthcare system perspective. Transition probabilities were mainly referred from the FLAVOUR trial, and healthcare costs were mainly obtained through analysis of Korean National Health Insurance claims data. Health utilities were mainly obtained from the Seattle Angina Questionnaire responses of FLAVOUR trial participants mapped to EQ-5D.
Results:
From the Korean healthcare system perspective, the base-case analysis showed that FFR-guided PCI was 2,451 U.S. dollar lower in lifetime healthcare costs and 0.178 higher in QALYs compared to IVUS-guided PCI. FFR-guided PCI remained more likely to be cost-effective over a wide range of willingness-to-pay thresholds in the probabilistic sensitivity analysis.
Conclusions
Based on the results from the FLAVOUR trial, FFR-guided PCI is projected to decrease lifetime healthcare costs and increase QALYs compared with IVUS-guided PCI in intermediate coronary lesion, and it is a dominant strategy in Korea.
6.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
7.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
8.Can It be Said that this Case Confirmed the Phenomenon of Subacromial Suture Knot Impingement after Arthroscopic Rotator Cuff Repair?: A Case Report
Sung Hwan KIM ; Seung Won CHOI ; Sin Hyung PARK ; Yong Bok PARK
The Korean Journal of Sports Medicine 2025;43(1):41-45
Rotator cuff tears are common shoulder injuries, particularly in older adults. Arthroscopic rotator cuff repair (ARCR) is the preferred treatment due to its successful outcomes, but complications like suture knot impingement may arise.Knot impingement, although rare, can lead to subacromial bone erosion and persistent pain. The condition remains under-reported, and direct evidence linking knot impingement to subacromial erosion is scarce. A 63-year-old woman presented with progressively worsening shoulder pain and restricted range of motion, 10 years after undergoing ARCR. Clinical assessment indicated subacromial impingement with positive Neer, Hawkins test results and reduced shoulder mobility. Arthroscopic evaluation revealed suture knots embedded in the subacromial bone, directly causing erosion. This is the first case to confirm through arthroscopy that subacromial bone erosion resulted from knot impingement. This case emphasizes the importance of follow-up and highlights the need to consider alternative suture techniques to avoid complications like knot impingement. Surgeons should be vigilant in minimizing risks associated with suture materials and techniques to improve long-term outcomes for patients undergoing ARCR.
9.Bisphenol Analogs Downregulate the Self-Renewal Potential of Spermatogonial Stem Cells
Seo-Hee KIM ; Seung Hee SHIN ; Seok-Man KIM ; Sang-Eun JUNG ; Beom-Jin SHIN ; Jin Seop AHN ; Kyoung Taek LIM ; Dong-Hwan KIM ; Kichoon LEE ; Buom-Yong RYU
The World Journal of Men's Health 2025;43(1):154-165
Purpose:
In this study, we investigated the effect of bisphenol-A (BPA) and its major analogs, bisphenol-F (BPF), and bisphenol-S (BPS), on spermatogonial stem cells (SSCs) populations using in vitro SSC culture and in vivo transplantation models.
Materials and Methods:
SSCs enriched from 6- to 8-day-old C57BL/6-eGFP+ male mice testes were treated with varying concentrations of bisphenols for 7 days to examine bisphenol-derived cytotoxicity and changes in SSC characteristics. We utilized flow cytometry, immunocytochemistry, real-time quantitative reverse transcription-PCR, and western blot analysis. The functional alteration of SSCs was further investigated by examining donor SSC-derived spermatogenesis evaluation through in vivo transplantation and subsequent testis analysis.
Results:
BPF exhibited a similar inhibitory effect on SSCs as BPA, demonstrating a significant decrease in SSC survival, inhibition of proliferation, and induction of apoptosis. On the other hand, while BPS was comparatively weaker than BPA and BPF, it still showed significant SSC cytotoxicity. Importantly, SSCs exposed to BPA, BPF, and BPS exhibited a significant reduction in donor SSC-derived germ cell colonies per total number of cultured cells, indicating that, like BPA, BPF, and BPS can induce a comparable reduction in functional SSCs in the recipient animals. However, the progress of spermatogenesis, as evidenced by histochemistry and the expressions of PCNA and SSC specific markers, collectively indicates that BPA, BPF, and BPS may not adversely affect the spermatogenesis.
Conclusions
Our findings indicate that the major BPA substitutes, BPF and BPS, have significant cytotoxic effects on SSCs, similar to BPA. These effects may lead to a reduction in the functional self-renewal stem cell population and potential impacts on male fertility.
10.Establishment of an In Vitro Embryo-Endometrium Model Using Alginate-Embedded Mouse Embryos and Human Embryoid Body
Yoon Young KIM ; Yong Jin KIM ; Jung Woo KIM ; Jiyeon KIM ; Sung Woo KIM ; Seung-Yup KU
Tissue Engineering and Regenerative Medicine 2025;22(1):77-89
BACKGROUND:
Embryo-endometrium cross-talk is one of the critical processes for implantation, and unsuccessful cross-talk leads to infertility. We established an endometrium-embryo (or embryoid bodies, hEBs) in vitro model in 2D and 3D conditions and assessed its potential through the fusion of embryos and the expression of specific markers.
METHODS:
C57BL/6 mouse embryos and human embryoid body (hEB) derived from embryonic stem cells were prepared as embryo models. Mouse endometrium (EM) and human endometrium cell line, HEC-1-A, were prepared, and 2D or 3D EMs were generated. The viability of the 3D endometrium was analyzed, and the optimal ratio of the gelation was revealed. The invasion of the embryos or hEBs was examined by immunostaining and 3D image rendering.
RESULTS:
The embryos and the alternative hEBs were effectively fused into 2D or 3D vitro EM models in both mouse and human models. The fused embryos and hEBs exhibited migration and further development. Notably, the established in vitro model expressed Oct4 and E-Cadherin, markers for early embryonic development; human CG Receptor and Progesterone Receptor, critical for implantation and pregnancy maintenance; and TSH Receptor, Epiregulin, and Prolactin, indicators of endometrial receptivity and embryo implantation.
CONCLUSION
This study marks a significant advancement in the field, as we have successfully established a novel in vitro model for studying embryo-endometrium cross-talk. This model, a crucial tool for understanding fertility and the causes of miscarriage due to failed implantation, provides a unique platform for investigating the complex processes of successful implantation and pregnancy, underscoring its potential impact on reproductive health.

Result Analysis
Print
Save
E-mail