1.The multi-center mid-term clinical outcomes of combined complete preservation of chordal structure mitral valve replacement with total anatomic complete arterial myocardial revascularization for coronary patients with moderate-to-severe or severe ischemic mitral regurgitation
Ke GUO ; Xujun CHEN ; Baoshi ZHENG ; Chao SHI ; Keli HUANG ; Yong CAO ; Chengquan LIAO ; Jingwei CHEN ; Yu LIN ; Chengxin LIU ; Quansheng CAO ; Lin SHEN ; Zhendong WANG
Chinese Journal of Surgery 2025;63(1):58-67
Objective:To evaluate the clinical outcomes of combined complete preservation of chordal structure mitral valve replacement (C-MVR) with total anatomical arterial myocardial revascularization (TACR) in coronary patients with moderate-to-severe or severe ischemic mitral regurgitation (IMR).Methods:This is a retrospective multi-center case series study. Data were retrospectively collected from 127 patients with coronary artery disease with moderate to severe or severe IMR who received TACR with C-MVR from July 2015 to April 2024 in 13 hospitals in China. There were 90 males and 37 females, aged (56.5±10.7) years (range: 33 to 74 years). Perioperative data and follow-up data including left ventricular ejection fraction, left ventricular end-diastolic diameter, and patency rate of arterial grafts of patients were collected. Comparisons were made using paired sample t-test or χ2 test. Results:In this cohort of 127 patients, 67 underwent concurrent tricuspid valve repair. During surgery, 113 grafts of the left internal mammary artery (LIMA), 127 grafts of the left radial artery, 80 grafts of the right radial artery, and 110 grafts of the right internal mammary artery (RIMA) were harvested. The number of the distal anastomosis was 4.2±0.4 (range: 3 to 5). The aortic cross-clamp time and cardiopulmonary bypass time were (97.5±23.4) minutes (range: 90 to 161 minutes) and (145.4±19.2) minutes (range: 101 to 210 minutes), respectively. There was one operative death. Intraoperative placement of an intra-aortic balloon pump was performed in 21 patients to improve the left ventricular ejection. No sternal ischemic occurred. All patients completed follow-up, with a mean follow-up period of (64.3±7.5) months (range: 4 to 110 months). No major cerebrovascular events occurred during the follow-up period, and all patients survived. Left ventricular ejection fraction improved postoperatively (55.0%±5.3% vs. 41.0%±15.3%, t=17.23, P<0.01). The proportion of patients with New York Heart Association functional class ≤2 increased postoperatively (23.6% (30/127) vs. 87.3% (110/126), χ2=103.77, P<0.01). The proportion of patients with Canadian Cardiovascular Society Angina Classification ≤3 decreased postoperatively (4.8% (6/126) vs. 78.7% (100/127), χ2=142.19, P<0.01). The left ventricular end-diastolic diameter decreased postoperatively ((5.70±4.50) cm vs. (6.10±0.23) cm, t=12.15, P<0.01). Coronary multi-detector computed tomography angiography (MDCTA) follow-up was conducted for (60.5±11.7) months (range: 6 to 109 months) postoperatively. MDCTA confirmed the patency rates of the grafts: 96.4% (108/112) for the LIMA grafts, 88.9% (112/126) for the left radial artery grafts, 93.7% (74/79) for the right radial artery grafts, and 90.9% (100/110) for the free RIMA grafts. No significant differences in graft patency rates were observed between the arterial grafts ( χ2=5.24, P=0.155). Conclusion:The results of this multi-centre study demonstrate satisfactory mid-term results of C-MVR with TACR for the treatment of coronary artery disease with moderate to severe or severe IMR.
2.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
3.The multi-center mid-term clinical outcomes of combined complete preservation of chordal structure mitral valve replacement with total anatomic complete arterial myocardial revascularization for coronary patients with moderate-to-severe or severe ischemic mitral regurgitation
Ke GUO ; Xujun CHEN ; Baoshi ZHENG ; Chao SHI ; Keli HUANG ; Yong CAO ; Chengquan LIAO ; Jingwei CHEN ; Yu LIN ; Chengxin LIU ; Quansheng CAO ; Lin SHEN ; Zhendong WANG
Chinese Journal of Surgery 2025;63(1):58-67
Objective:To evaluate the clinical outcomes of combined complete preservation of chordal structure mitral valve replacement (C-MVR) with total anatomical arterial myocardial revascularization (TACR) in coronary patients with moderate-to-severe or severe ischemic mitral regurgitation (IMR).Methods:This is a retrospective multi-center case series study. Data were retrospectively collected from 127 patients with coronary artery disease with moderate to severe or severe IMR who received TACR with C-MVR from July 2015 to April 2024 in 13 hospitals in China. There were 90 males and 37 females, aged (56.5±10.7) years (range: 33 to 74 years). Perioperative data and follow-up data including left ventricular ejection fraction, left ventricular end-diastolic diameter, and patency rate of arterial grafts of patients were collected. Comparisons were made using paired sample t-test or χ2 test. Results:In this cohort of 127 patients, 67 underwent concurrent tricuspid valve repair. During surgery, 113 grafts of the left internal mammary artery (LIMA), 127 grafts of the left radial artery, 80 grafts of the right radial artery, and 110 grafts of the right internal mammary artery (RIMA) were harvested. The number of the distal anastomosis was 4.2±0.4 (range: 3 to 5). The aortic cross-clamp time and cardiopulmonary bypass time were (97.5±23.4) minutes (range: 90 to 161 minutes) and (145.4±19.2) minutes (range: 101 to 210 minutes), respectively. There was one operative death. Intraoperative placement of an intra-aortic balloon pump was performed in 21 patients to improve the left ventricular ejection. No sternal ischemic occurred. All patients completed follow-up, with a mean follow-up period of (64.3±7.5) months (range: 4 to 110 months). No major cerebrovascular events occurred during the follow-up period, and all patients survived. Left ventricular ejection fraction improved postoperatively (55.0%±5.3% vs. 41.0%±15.3%, t=17.23, P<0.01). The proportion of patients with New York Heart Association functional class ≤2 increased postoperatively (23.6% (30/127) vs. 87.3% (110/126), χ2=103.77, P<0.01). The proportion of patients with Canadian Cardiovascular Society Angina Classification ≤3 decreased postoperatively (4.8% (6/126) vs. 78.7% (100/127), χ2=142.19, P<0.01). The left ventricular end-diastolic diameter decreased postoperatively ((5.70±4.50) cm vs. (6.10±0.23) cm, t=12.15, P<0.01). Coronary multi-detector computed tomography angiography (MDCTA) follow-up was conducted for (60.5±11.7) months (range: 6 to 109 months) postoperatively. MDCTA confirmed the patency rates of the grafts: 96.4% (108/112) for the LIMA grafts, 88.9% (112/126) for the left radial artery grafts, 93.7% (74/79) for the right radial artery grafts, and 90.9% (100/110) for the free RIMA grafts. No significant differences in graft patency rates were observed between the arterial grafts ( χ2=5.24, P=0.155). Conclusion:The results of this multi-centre study demonstrate satisfactory mid-term results of C-MVR with TACR for the treatment of coronary artery disease with moderate to severe or severe IMR.
4.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
5.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
6.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
7.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
8.Identification strategy of cold and hot properties of Chinese herbal medicines based on artificial intelligence and biological experiments.
Lin LIN ; Pengcheng ZHAO ; Zhao CHEN ; Bin LIU ; Yuexi WANG ; Qi GENG ; Li LI ; Yong TAN ; Xiaojuan HE ; Li LI ; Jianyu SHI ; Cheng LU
Chinese Medical Journal 2025;138(6):745-747
9.A new triterpenoid from Elephantopus scaber.
Zu-Xiao DING ; Hong-Xi XIE ; Lin CHEN ; Jun-Jie HAO ; Yan-Qiu LUO ; Zhi-Yong JIANG ; Shi-Kui XU
China Journal of Chinese Materia Medica 2025;50(5):1224-1230
The chemical constituents of the petroleum ether extract derived from the 90% ethanol extract of Elephantopus scaber were investigated. By silica gel column chromatography, C_(18), MCI column chromatography and semi-preparative high performance liquid chromatography, ten compounds were isolated. Their structures were identified as 3β-hydroxy-6β,7β-epoxytaraxeran-14-ene(1), 3β-hydroxyolean-12-en-28-oic acid(2), D-friedoolean-14-ene-3β,7α-diol(3), 3β-hydroxy-11α-methoxyolean-12-ene(4), 3β-hydroxyolean-11,13(18)-diene(5), 11α-hydroxy-β-amyrin(6), betulinic acid(7), 3β-hydroxy-30-norlupan-20-one(8), 6-acetonylchelerythrine(9), and 4',5'-dehydrodiodictyonema A(10) by analysis of the 1D NMR, 2D NMR, MS, and IR spectral data. Among them, compound 1 was a new triterpene and other compounds except compounds 2 and 7 were isolated from this plant for the first time.
Triterpenes/isolation & purification*
;
Drugs, Chinese Herbal/isolation & purification*
;
Molecular Structure
;
Asteraceae/chemistry*
;
Chromatography, High Pressure Liquid
;
Magnetic Resonance Spectroscopy
10.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures

Result Analysis
Print
Save
E-mail