1.Current quality status and management countermeasures of occupational health technical services in Zhejiang Province
Qiuliang XU ; Feng HAN ; Peng WANG ; Zhen ZHOU ; Fei LI ; Hongwei XIE ; Yong HU ; Weiming YUAN ; Lifang ZHOU ; Hua ZOU
Journal of Environmental and Occupational Medicine 2026;43(3):341-346
Background The quality of occupational health technical services is directly linked to the protection of workers' health rights and the efficacy of occupational disease prevention and control. However, the industry still faces critical challenges: sporadic instances of institutional non-compliance and persistent irregularities in professional practice continue to undermine overall service performance. Objective To assess the current quality status of occupational health technical services in Zhejiang Province and propose countermeasures for quality improvement, providing a scientific basis for policy optimization and service delivery quality enhancement. Methods A total of 69 occupational health technical service institutions in Zhejiang Province that obtained formal accreditation as of April 30, 2024, were sampled, including 3 public institutions and 66 private institutions (comprising 3 formerly Class-A, 28 formerly Class-B, 11 formerly Class-C, and 24 newly certified institutions). Following the Technical Protocol for Quality Monitoring of Occupational Health Technical Service in Zhejiang Province and the Technical Protocol for Proficiency Testing of Occupational Health Detection in Zhejiang Province, a quality assessment task force comprising national and provincial experts was established. Evaluation was conducted across four dimensions: qualification maintenance and compliance, standardization of technical services, authenticity of technical services, and proficiency testing, utilizing a combination of document review, on-site inspections, and technical skill assessments. Results The occupational health technical service institutions in Zhejiang Province were predominantly private entities (82.5%), with significant disparities in overall service quality. The pass rates for qualification maintenance and compliance, technical service standardization, technical service authenticity, and the excellence rate for laboratory proficiency testing were 81.5%, 80.7%, 97.3%, and 90.4%, respectively. Regarding qualification maintenance, the pass rates for "environmental conditions" (49.8%, 56.7%) and "instrumentation and equipment" (58.2%、65.6%) were significantly lower for formerly Class-C and newly certified institutions compared to other categories. In terms of technical standardization, "standardized on-site inspections" recorded the lowest pass rate (67.4%), with newly certified institutions at only 48.0%. Regarding technical service authenticity, formerly Class-C institutions exhibited issues such as missing raw chromatograms for blank samples (85.7% pass rate). In laboratory proficiency testing, public and formerly Class-A institutions achieved 100% excellence rates, but the performance of formerly Class-C and newly certified institutions was comparatively weak; specifically, the failure rate for organic analysis in formerly Class-C institutions reached 20%; the failure rate for dust testing items in newly certified institutions was 10.3%. Conclusion The overall quality of occupational health technical services in Zhejiang Province still requires significant improvement, particularly in basic institutional conditions, the standardization of on-site inspections, and laboratory proficiency in organic and dust analysis. Formerly Class-C and newly certified institutions should be the primary focus of quality management efforts. Differentiated regulatory strategies are recommended, alongside strengthening interim and ex-post supervision to gradually enhance the quality of occupational health technical services across all institutions.
2.Allogeneic lung transplantation in miniature pigs and postoperative monitoring
Yaobo ZHAO ; Ullah SALMAN ; Kaiyan BAO ; Hua KUI ; Taiyun WEI ; Hongfang ZHAO ; Xiaoting TAO ; Xinzhong NING ; Yong LIU ; Guimei ZHANG ; He XIAO ; Jiaoxiang WANG ; Chang YANG ; Feiyan ZHU ; Kaixiang XU ; Kun QIAO ; Hongjiang WEI
Organ Transplantation 2026;17(1):95-105
Objective To explore the feasibility and reference value of allogeneic lung transplantation and postoperative monitoring in miniature pigs for lung transplantation research. Methods Two miniature pigs (R1 and R2) underwent left lung allogeneic transplantation. Complement-dependent cytotoxicity tests and blood cross-matching were performed before surgery. The main operative times and partial pressure of arterial oxygen (PaO2) after opening the pulmonary artery were recorded during surgery. Postoperatively, routine blood tests, biochemical blood indicators and inflammatory factors were detected, and pathological examinations of multiple organs were conducted. Results The complement-dependent cytotoxicity test showed that the survival rate of lymphocytes between donors and recipients was 42.5%-47.3%, and no agglutination reaction occurred in the cross-matching. The first warm ischemia times of D1 and D2 were 17 min and 10 min, respectively, and the cold ischemia times were 246 min and 216 min, respectively. Ultimately, R1 and R2 survived for 1.5 h and 104 h, respectively. Postoperatively, in R1, albumin (ALB) and globulin (GLB) decreased, and alanine aminotransferase increased; in R2, ALB, GLB and aspartate aminotransferase all increased. Urea nitrogen and serum creatinine increased in both recipients. Pathological results showed that in R1, the transplanted lung had partial consolidation with inflammatory cell infiltration, and multiple organs were congested and damaged. In R2, the transplanted lung had severe necrosis with fibrosis, and multiple organs had mild to moderate damage. The expression levels of interleukin-1β and interleukin-6 increased in the transplanted lungs. Conclusions The allogeneic lung transplantation model in miniature pigs may systematically evaluate immunological compatibility, intraoperative function and postoperative organ damage. The data obtained may provide technical references for subsequent lung transplantation research.
3.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
4.Effect of Zhengan Xifengtang on Intestinal Mucosal Barrier in Spontaneously Hypertensive Rats via FXR-MLCK/p-MLC Pathway
Meilong SI ; Hua JIN ; Yu WANG ; Qiuju ZHANG ; Tao LIU ; Yun YONG ; Xuan BAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(21):1-10
ObjectiveTo investigate the repair effects of Zhengan Xifengtang on intestinal mucosal barrier in spontaneously hypertensive rats (SHRs) through the pathways of farnesoid X receptor (FXR)-myosin light chain kinase (MLCK)/phosphorylated myosin light chain (p-MLC) and its potential mechanism. MethodsForty 10-week-old male SHRs were randomly divided into model group, amlodipine besylate group (0.5 mg·kg-1·d-1), and high, middle and low dose groups of Zhengan Xifengtang (34.5, 17.25, 8.625 g·kg-1·d-1); eight age-matched male Wistar-Kyoto (WKY) rats of the same origin served as the normal control group. Drug intervention was carried out for 8 weeks, and the blood pressure of the rats was measured regularly. After the intervention, the rats were euthanized to collect tissue samples. Hematoxylin and eosin (HE) staining and Alcian blue-periodic acid-Schiff (AB-PAS) staining were used to evaluate the pathological morphology and the number of goblet cells in colonic mucosa. Enzyme-linked immunosorbent assay (ELISA) was employed to measure plasma lipopolysaccharide (LPS) and diamine oxidase (DAO) levels in each group of rats. Immunofluorescence (IF) assay was used to detect the relative fluorescence intensity of FXR and p-MLC in colonic tissue. Western blot was used to detect the zonula occludens-1 (ZO-1), Occludin, Claudin-1, junctional adhesion molecule-1 (JAM-1), mucin-2 (MUC2), FXR, MLCK, and p-MLC protein expression in colon tissue. Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) was used to detect mRNA expression levels of ZO-1, Occludin, Claudin-1, JAM-1, MUC2, FXR, MLCK, and MLC in colon tissue. ResultsCompared with the normal group, the blood pressure in the model group increased significantly (P<0.01), the colonic mucosal structure was seriously damaged, and the number of goblet cells decreased significantly. The contents of LPS and DAO increased significantly (P<0.01), the relative fluorescence intensity of FXR in colon decreased, while that of p-MLC increased (P<0.01). The protein and mRNA expressions of ZO-1, Claudin-1, JAM-1, Occludin, MUC2 and FXR decreased significantly (P<0.01), whereas the protein expression of MLCK and p-MLC increased significantly (P<0.01). Additionally, the mRNA expression of MLCK and MLC increased significantly (P<0.01). Compared with the model group, the Zhengan Xifengtang groups at various dosages and the amlodipine besylate group showed significantly reduced blood pressure (P<0.01). The damage of colonic mucosa structure was alleviated, the infiltration of inflammatory cells decreased, and the number of goblet cells increased. LPS and DAO levels were decreased (P<0.05, P<0.01). In the colon, the relative fluorescence intensity of FXR increased, while that of p-MLC decreased (P<0.05, P<0.01). The protein and mRNA expression levels of ZO-1, Claudin-1, JAM-1, Occludin, and FXR increased significantly (P<0.05, P<0.01), while the protein expression of MLCK and p-MLC decreased significantly (P<0.05, P<0.01). Furthermore, the mRNA expression of MLCK and MLC decreased significantly (P<0.05, P<0.01), and the protein expression of MUC2 increased significantly (P<0.05, P<0.01). The expression of MUC2 mRNA in each dose group of Zhengan Xifengtang increased significantly (P<0.05, P<0.01). ConclusionZhengan Xifengtang may regulate the FXR-MLCK/p-MLC signaling pathway and enhance the expression of tight junction protein, thereby reducing intestinal mucosal permeability, promoting mucosal barrier repair, decreasing LPS release into the blood, and ultimately lowering blood pressure.
5.Effect of Zhengan Xifengtang on Intestinal Mucosal Barrier in Spontaneously Hypertensive Rats via FXR-MLCK/p-MLC Pathway
Meilong SI ; Hua JIN ; Yu WANG ; Qiuju ZHANG ; Tao LIU ; Yun YONG ; Xuan BAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(21):1-10
ObjectiveTo investigate the repair effects of Zhengan Xifengtang on intestinal mucosal barrier in spontaneously hypertensive rats (SHRs) through the pathways of farnesoid X receptor (FXR)-myosin light chain kinase (MLCK)/phosphorylated myosin light chain (p-MLC) and its potential mechanism. MethodsForty 10-week-old male SHRs were randomly divided into model group, amlodipine besylate group (0.5 mg·kg-1·d-1), and high, middle and low dose groups of Zhengan Xifengtang (34.5, 17.25, 8.625 g·kg-1·d-1); eight age-matched male Wistar-Kyoto (WKY) rats of the same origin served as the normal control group. Drug intervention was carried out for 8 weeks, and the blood pressure of the rats was measured regularly. After the intervention, the rats were euthanized to collect tissue samples. Hematoxylin and eosin (HE) staining and Alcian blue-periodic acid-Schiff (AB-PAS) staining were used to evaluate the pathological morphology and the number of goblet cells in colonic mucosa. Enzyme-linked immunosorbent assay (ELISA) was employed to measure plasma lipopolysaccharide (LPS) and diamine oxidase (DAO) levels in each group of rats. Immunofluorescence (IF) assay was used to detect the relative fluorescence intensity of FXR and p-MLC in colonic tissue. Western blot was used to detect the zonula occludens-1 (ZO-1), Occludin, Claudin-1, junctional adhesion molecule-1 (JAM-1), mucin-2 (MUC2), FXR, MLCK, and p-MLC protein expression in colon tissue. Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) was used to detect mRNA expression levels of ZO-1, Occludin, Claudin-1, JAM-1, MUC2, FXR, MLCK, and MLC in colon tissue. ResultsCompared with the normal group, the blood pressure in the model group increased significantly (P<0.01), the colonic mucosal structure was seriously damaged, and the number of goblet cells decreased significantly. The contents of LPS and DAO increased significantly (P<0.01), the relative fluorescence intensity of FXR in colon decreased, while that of p-MLC increased (P<0.01). The protein and mRNA expressions of ZO-1, Claudin-1, JAM-1, Occludin, MUC2 and FXR decreased significantly (P<0.01), whereas the protein expression of MLCK and p-MLC increased significantly (P<0.01). Additionally, the mRNA expression of MLCK and MLC increased significantly (P<0.01). Compared with the model group, the Zhengan Xifengtang groups at various dosages and the amlodipine besylate group showed significantly reduced blood pressure (P<0.01). The damage of colonic mucosa structure was alleviated, the infiltration of inflammatory cells decreased, and the number of goblet cells increased. LPS and DAO levels were decreased (P<0.05, P<0.01). In the colon, the relative fluorescence intensity of FXR increased, while that of p-MLC decreased (P<0.05, P<0.01). The protein and mRNA expression levels of ZO-1, Claudin-1, JAM-1, Occludin, and FXR increased significantly (P<0.05, P<0.01), while the protein expression of MLCK and p-MLC decreased significantly (P<0.05, P<0.01). Furthermore, the mRNA expression of MLCK and MLC decreased significantly (P<0.05, P<0.01), and the protein expression of MUC2 increased significantly (P<0.05, P<0.01). The expression of MUC2 mRNA in each dose group of Zhengan Xifengtang increased significantly (P<0.05, P<0.01). ConclusionZhengan Xifengtang may regulate the FXR-MLCK/p-MLC signaling pathway and enhance the expression of tight junction protein, thereby reducing intestinal mucosal permeability, promoting mucosal barrier repair, decreasing LPS release into the blood, and ultimately lowering blood pressure.
6.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
7.Quality evaluation of Gegen Formula Granules
Dai-liang ZHANG ; Chun-xia WANG ; Lei SHI ; Yu-kang LIU ; Yong-qiang LIN ; Yu-zhuo WANG ; Jing-hua ZHANG ; Jin-xin LI ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(5):1421-1431
AIM To evaluate the quality of Gegen Formula Granules.METHODS Linear calibration with two reference substances(LCTRS)was adopted in the predicting of retention time with puerarin and daidzein as internal standards.UPLC characteristic chromatograms were established.The contents of 3'-hydroxy puerarin,puerarin(internal standard),3'-methoxy puerarin,puerarin 6"-O-xyloside,puerarin apioside and daidzin were determined by quantitative determination analysis multi-components by a single marker(QAMS),after which their transfer rates were calculated.RESULTS Compared with relative retention time method,LCTRS demonstrated higher positional accuracy for characteristic peaks and wider application range for columns.There were 9 characteristic peaks in the characteristic chromatograms for 14 batches of formula granules and 15 batches of standard decoctions with the similarities of more than 0.95.The contents and transfer rates of various constituents in formula granules and standard decoctions were basically consistent.CONCLUSION The chemical constituents in formula granules and their standard decoctions of Puerariae lobatae Radix display good consistency,reliable preparation process is observable in the former.
8.Construction of a Competency Evaluation Model for Forensic Practitioners
Jing-Chun BAO ; Jing-Jing ZHAO ; Jiao-Yong LI ; Jing-Hua MENG ; Xiao-Long WANG ; Xiao-Ni ZHAN ; Jun YAO ; Xu WU
Journal of Forensic Medicine 2025;41(4):371-379
Objective To construct a competency evaluation model for forensic practitioners,providing a reference for their training and assessment.Methods Based on the iceberg and onion models of com-petency,and with reference to Spencer's Competency Dictionary,literature research was conducted and focus group interviews were employed to preliminarily construct core indices and measurement items for evaluating the competency of forensic practitioners.The Delphi method was applied for two rounds of expert consultation to further refine the competency evaluation index system.The analytic hierarchy process(AHP)was used to calculate the weights of the indices.Results A competency evaluation model for forensic practitioners was constructed,consisting of 7 core indices,encompassing forensic skills,identification service capabilities,and the ability to apply relevant legal knowledge and 49 mea-surement items.The weights of the core indices and measurement items were determined.Conclusion The constructed competency evaluation model for forensic practitioners is scientifically sound and inno-vative,and has unique characteristics of forensic medicine compared with other medical models.
9.Effect of neutrophil elastase inhibitor on acute respiratory distress syndrome in children
Hua ZHANG ; Weikai WANG ; Zhangyan GUO ; Yanqiang DU ; Yong ZHOU ; Yi WANG
International Journal of Pediatrics 2025;52(1):55-60
Objective:To investigate the efficacy of neutrophil elastase inhibitor in children with acute respiratory distress syndrome(ARDS).Methods:A total of 168 children with moderate to severe ARDS who were hospitalized in the Department of Pediatric Intensive Care Unit,the Affiliated Children′s Hospital of Xi′an Jiaotong University and Children's Emergency Center of Gansu Provincial Central Hospital from January 2022 to December 2023 were selected. Eighty-seven children receiving neutrophil elastase inhibitors were treated as the treatment group and 81 children receiving conventional treatment as the control group. The dynamic changes of general data,clinical indicators and ventilator parameters at 24 h,48 h and 72 h were compared between the two groups. Mortality at 28 days was the primary endpoint. Kaplan-Meier curve and Log-Rank test were used to evaluate cumulative survival.Results:There was no significant difference in general information and clinical characteristics between the two groups.Compared with the control group,arterial partial pressure of oxygen(PaO 2)/fraction of inspired oxygen(FiO 2)in the treatment group increased significantly at 48 h[(160.28±5.90)mmHg(1 mmHg=0.133 kPa)vs(141.04±4.01)mmHg, P<0.05]and 72 h[(227.58±6.85)mmHg vs(180.86±4.08)mmHg, P<0.05],and the differences were statistically significant.The platform pressure in the treatment group were lower than that of the control group at 24 h[(28.18±3.95)cmH 2O(1cmH 2O=0.098 kPa)vs(30.15±7.75)cmH 2O, P<0.05],48 h[(25.56±4.06)cmH 2O vs(29.07±5.01)cmH 2O, P<0.05],72 h[(24.95±2.82)cmH 2O vs(27.12±6.51)cmH 2O, P<0.05],and the differences were statistically significant. IL-8 in the treatment group were lower than that of the control group at 48 h[(78.26±14.05)ng/L vs(86.02±15.01)ng/L, P<0.05]and 72 h[(58.38±15.56)ng/L vs(68.68±18.05)ng/L, P<0.05],and the differences were statistically significant.The survival curve showed that the cumulative survival rate of the treatment group was higher than that of the control group,the difference between the two groups was statistically significant( χ2=4.549, P=0.033). Conclusion:Neutrophil elastase inhibitors can reduce the lung injury of ARDS patients by inhibiting the inflammatory response induced by neutrophils,and ultimately improve the prognosis of the disease.
10.Prediction of testicular histology in azoospermia patients through deep learning-enabled two-dimensional grayscale ultrasound.
Jia-Ying HU ; Zhen-Zhe LIN ; Li DING ; Zhi-Xing ZHANG ; Wan-Ling HUANG ; Sha-Sha HUANG ; Bin LI ; Xiao-Yan XIE ; Ming-De LU ; Chun-Hua DENG ; Hao-Tian LIN ; Yong GAO ; Zhu WANG
Asian Journal of Andrology 2025;27(2):254-260
Testicular histology based on testicular biopsy is an important factor for determining appropriate testicular sperm extraction surgery and predicting sperm retrieval outcomes in patients with azoospermia. Therefore, we developed a deep learning (DL) model to establish the associations between testicular grayscale ultrasound images and testicular histology. We retrospectively included two-dimensional testicular grayscale ultrasound from patients with azoospermia (353 men with 4357 images between July 2017 and December 2021 in The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China) to develop a DL model. We obtained testicular histology during conventional testicular sperm extraction. Our DL model was trained based on ultrasound images or fusion data (ultrasound images fused with the corresponding testicular volume) to distinguish spermatozoa presence in pathology (SPP) and spermatozoa absence in pathology (SAP) and to classify maturation arrest (MA) and Sertoli cell-only syndrome (SCOS) in patients with SAP. Areas under the receiver operating characteristic curve (AUCs), accuracy, sensitivity, and specificity were used to analyze model performance. DL based on images achieved an AUC of 0.922 (95% confidence interval [CI]: 0.908-0.935), a sensitivity of 80.9%, a specificity of 84.6%, and an accuracy of 83.5% in predicting SPP (including normal spermatogenesis and hypospermatogenesis) and SAP (including MA and SCOS). In the identification of SCOS and MA, DL on fusion data yielded better diagnostic performance with an AUC of 0.979 (95% CI: 0.969-0.989), a sensitivity of 89.7%, a specificity of 97.1%, and an accuracy of 92.1%. Our study provides a noninvasive method to predict testicular histology for patients with azoospermia, which would avoid unnecessary testicular biopsy.
Humans
;
Male
;
Azoospermia/diagnostic imaging*
;
Deep Learning
;
Testis/pathology*
;
Retrospective Studies
;
Adult
;
Ultrasonography/methods*
;
Sperm Retrieval
;
Sertoli Cell-Only Syndrome/diagnostic imaging*

Result Analysis
Print
Save
E-mail