2.Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia
Yong Hee KIM ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):134-144
Purpose:
To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development.
Methods:
Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development.
Results:
At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05).
Conclusions
This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.
3.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
4.Diagnosing Complete Response to Preoperative Chemoradiation in Esophageal Cancer Using Dynamic Contrast-Enhanced MRI Response Criteria
Yura AHN ; Jooae CHOE ; Hyun Joo LEE ; Sook Ryun PARK ; Jong-Hoon KIM ; Ho June SONG ; Min-Ju KIM ; Yong-Hee KIM
Korean Journal of Radiology 2025;26(3):269-280
Objective:
To assess the performance of novel qualitative diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to identify the pathologic complete response (pCR) of primary tumors in esophageal cancer after neoadjuvant chemoradiation (nCRT).
Materials and Methods:
Patients who underwent nCRT, subsequent MRI, positron emission tomography/computed tomography (PET/CT), endoscopy, or esophagectomy for esophageal cancer between October 2021 and October 2023 were retrospectively analyzed. The DCE-MRI response of primary tumors was interpreted using five grades by thoracic radiologists as follows: G1 (compatible with CR), G2 (probable CR), G3 (probable partial response [PR]), G4 (compatible with PR), and G5 (stable or progressive disease). The performances of MRI, PET/CT, endoscopy, and their combinations in diagnosing pCR in primary tumors were calculated.
Results:
A total of 52 patients (male:female, 46:6; age, 61.2 ± 8.0 years) were included. Surgical specimens revealed pCR (ypT0) in 34 patients. G1 as the MRI criterion for pCR of primary tumors yielded a positive predictive value (PPV), specificity of 100% (18/18), and low sensitivity (23.5% [8/34]). Combining G1 and G2 as the MRI criteria increased the sensitivity to 73.5% (25/34), with a specificity of 88.9% (16/18), accuracy of 78.8% (41/52), and PPV of 92.6% (25/27). Adding the DCEMRI results (G1-2) significantly improved accuracy for both PET/CT (from 65.4% [34/52] to 80.8% [42/52], P = 0.03) and endoscopy (from 55.8% [29/52] to 76.9% [40/52], P = 0.005), with increase in sensitivity (from 55.9% [19/34] to 82.4% [28/34] for PET/CT-based evaluation [P = 0.008] and from 47.1% [16/34] to 82.4% [28/34] for endoscopy-based evaluation [P = 0.001]).
Conclusion
DCE-MRI-based grading shows high diagnostic performance for identifying pCR in primary tumors, particularly in terms of PPV and specificity, and enhances response evaluation when combined with PET/CT and endoscopy.
6.Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia
Yong Hee KIM ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):134-144
Purpose:
To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development.
Methods:
Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development.
Results:
At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05).
Conclusions
This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.
7.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
8.Diagnosing Complete Response to Preoperative Chemoradiation in Esophageal Cancer Using Dynamic Contrast-Enhanced MRI Response Criteria
Yura AHN ; Jooae CHOE ; Hyun Joo LEE ; Sook Ryun PARK ; Jong-Hoon KIM ; Ho June SONG ; Min-Ju KIM ; Yong-Hee KIM
Korean Journal of Radiology 2025;26(3):269-280
Objective:
To assess the performance of novel qualitative diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to identify the pathologic complete response (pCR) of primary tumors in esophageal cancer after neoadjuvant chemoradiation (nCRT).
Materials and Methods:
Patients who underwent nCRT, subsequent MRI, positron emission tomography/computed tomography (PET/CT), endoscopy, or esophagectomy for esophageal cancer between October 2021 and October 2023 were retrospectively analyzed. The DCE-MRI response of primary tumors was interpreted using five grades by thoracic radiologists as follows: G1 (compatible with CR), G2 (probable CR), G3 (probable partial response [PR]), G4 (compatible with PR), and G5 (stable or progressive disease). The performances of MRI, PET/CT, endoscopy, and their combinations in diagnosing pCR in primary tumors were calculated.
Results:
A total of 52 patients (male:female, 46:6; age, 61.2 ± 8.0 years) were included. Surgical specimens revealed pCR (ypT0) in 34 patients. G1 as the MRI criterion for pCR of primary tumors yielded a positive predictive value (PPV), specificity of 100% (18/18), and low sensitivity (23.5% [8/34]). Combining G1 and G2 as the MRI criteria increased the sensitivity to 73.5% (25/34), with a specificity of 88.9% (16/18), accuracy of 78.8% (41/52), and PPV of 92.6% (25/27). Adding the DCEMRI results (G1-2) significantly improved accuracy for both PET/CT (from 65.4% [34/52] to 80.8% [42/52], P = 0.03) and endoscopy (from 55.8% [29/52] to 76.9% [40/52], P = 0.005), with increase in sensitivity (from 55.9% [19/34] to 82.4% [28/34] for PET/CT-based evaluation [P = 0.008] and from 47.1% [16/34] to 82.4% [28/34] for endoscopy-based evaluation [P = 0.001]).
Conclusion
DCE-MRI-based grading shows high diagnostic performance for identifying pCR in primary tumors, particularly in terms of PPV and specificity, and enhances response evaluation when combined with PET/CT and endoscopy.
9.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
10.Clinical evaluation and management of endometriosis: 2024 guideline for Korean patients from the Korean Society of Endometriosis
Hyun Joo LEE ; Sang-Hee YOON ; Jae Hoon LEE ; Youn-Jee CHUNG ; So Yun PARK ; Sung Woo KIM ; Yeon Hee HONG ; Sung Eun KIM ; Youjin KIM ; Sungwook CHUN ; Yong Jin NA
Obstetrics & Gynecology Science 2025;68(1):43-58
Endometriosis, a prevalent but debilitating condition affecting women, poses significant challenges in diagnosis and management. The current 2024 guideline, developed by the Korean Society of Endometriosis (KSE), builds upon the 2018 KSE guideline. This guideline aims to provide customized recommendations tailored to Korea’s unique clinical aspects and medical environment, and addresses key areas such as diagnosis, medical and surgical management, considerations for special populations, and its complex relationship with cancer.