1.Early impact of robot-assisted total knee arthroplasty on the treatment of varus knee arthritis.
Xin YANG ; Qing-Hao CHENG ; Fu-Qiang ZHANG ; Hua FAN ; Fu-Kang ZHANG ; Zhuang-Zhuang ZHANG ; Yong-Ze YANG ; An-Ren ZHANG ; Hong-Zhang GUO
China Journal of Orthopaedics and Traumatology 2025;38(4):343-351
OBJECTIVE:
To investigate the clinical efficacy and advantages of robot-assisted total knee arthroplasty (TKA) in patients with varus knee osteoarthritis.
METHODS:
Between October 2022 and June 2023, a total of 59 patients with severe knee osteoarthritis resulting in varus were treated with total knee arthroplasty, aged from 59 to 81 years with an average (70.90±4.63) years, including 19 mals and 40 females. The patients were divided into two groups based on the surgical method used:28 patients in the robot group and 31 patients in the traditional group. The robot group consisted of 8 males and 20 femalse patients, with an average age of (70.54±4.80) years and an average disease duration of (14.89±8.72) months. The traditional group consisted of 11 males and 20 females patients, with an average age of (71.39±4.5) years and an average disease duration of (12.32±6.73) months. The operative duration, amount of bleeding during the operation, postoperative activity time after the operation, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and complications were compared between the two groups before and after the operation. Lateral tibia component (LTC), frontal tibia component (FTC), frontal femoral component (FFC) and lateral femoral component (LFC) were measured 6 months after operation Additionally, the degree of knee joint motility, American Knee Society score (KSS), and visual analogue scale(VAS) were compared before and after the operation.
RESULTS:
All patients had gradeⅠwound healing without any complications, and all patients were followed up for 6 to 8 months, with an average of (6.5±1.5) months. There were no significant differences preoperative imaging evaluation indexes (including HKA, LDFA, and MPTA), preoperative knee mobility, preoperative VAS, and preoperative KSS between the two groups (P>0.05). Comparing the operation time (109.11±7.16) min vs. (83.90±7.85) min, length of the incision (16.60±2.33) cm vs. (14.47±1.41) cm, intraoperative bleeding (106.93±6.15) ml vs. (147.97±7.62) ml, postoperative activity time (17.86±1.84) h vs. (21.77±2.68) h, between the two groups showed statistically significant differences (P<0.05). There were significant differences in FFC (88.96±0.84)° vs. (87.93±1.09)° and LFC (88.57±1.10)° vs. (87.16±1.2)° between the two groups at 6 months after operation (P<0.05). The robotic group 1, 3, 6 months after KSS (75.96±3.96), (81.53±3.78), (84.50±3.29) scores, VAS (3.68±0.67), (2.43±0.79), (0.54±0.64), knee joint mobility (113.32±4.72) °, (123.93±3.99) °, (135.36±2.34) °;Traditional group KSS (73.77±4.18), (76.48±3.60), (80.19±3.28) scores, VAS (4.16±1.04), (3.03±0.75), (1.42±0.76) scores, knee joint mobility (109.19±6.95) °, (119.94±6.08) °, (134.48±2.14) °. Compared to before surgery, both groups showed significant improvement in KSS, VAS and knee mobility during the three follow-up visits (P<0.001). Additionally, postoperative HKA (180.39±1.95)° vs. (178.52±2.23)°, LDFA (89.67±0.63) ° vs. (89.63±0.63)°, and MPTA (89.44±0.55)° vs. (89.29±0.60)° were significantly improved in both groups compared to before surgery (P<0.001). The robotic group had higher KSS than the traditional group at 1, 3, and 6 months after surgery (P<0.05). The robotic group also had lower VAS than the traditional group at 1, 3, and 6 months after surgery (P<0.05). Furthermore, knee mobility was higher in the robotic group than those in the traditional group at 1 and 6 months after surgery (P<0.05), but there was no significant difference between the two groups at 6 months after surgery.
CONCLUSION
Robot-assisted total knee arthroplasty is a safe and effective method for total knee replacement. The use of robotics can improve the limb axis and prosthesis alignment for patients with preoperative varus deformity, resulting in better clinical and imaging outcomes compared to the conventional group.
Humans
;
Female
;
Male
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Middle Aged
;
Osteoarthritis, Knee/physiopathology*
;
Aged, 80 and over
;
Robotic Surgical Procedures/methods*
2.Effectiveness and safety of augmentative plating technique in managing nonunion following intramedullary nailing of long bones in the lower extremity: A systematic review and meta-analysis.
Cong-Xiao FU ; Hao GAO ; Jun REN ; Hu WANG ; Shuai-Kun LU ; Guo-Liang WANG ; Zhen-Feng ZHU ; Yun-Yan LIU ; Wen LUO ; Yong ZHANG ; Yun-Fei ZHANG
Chinese Journal of Traumatology 2025;28(3):164-174
PURPOSE:
To methodically assess the effectiveness of augmentative plating (AP) and exchange nailing (EN) in managing nonunion following intramedullary nailing for long bone fractures of the lower extremity.
METHODS:
PubMed, EMBASE, Web of Science, and the Cochrane Library were searched to gather clinical studies regarding the use of AP and EN techniques in the treatment of nonunion following intramedullary nailing of lower extremity long bones. The search was conducted up until May 2023. The original studies underwent an independent assessment of their quality, a process conducted utilizing the Newcastle-Ottawa scale. Data were retrieved from these studies, and meta-analysis was executed utilizing Review Manager 5.3.
RESULTS:
This meta-analysis included 8 studies involving 661 participants, with 305 in the AP group and 356 in the EN group. The results of the meta-analysis demonstrated that the AP group exhibited a higher rate of union (odds ratio: 8.61, 95% confidence intervals (CI): 4.12 - 17.99, p < 0.001), shorter union time (standardized mean difference (SMD): -1.08, 95% CI: -1.79 - -0.37, p = 0.003), reduced duration of the surgical procedure (SMD: -0.56, 95% CI: -0.93 - -0.19, p = 0.003), less bleeding (SMD: -1.5, 95% CI: -2.81 - -0.18, p = 0.03), and a lower incidence of complications (relative risk: -0.17, 95% CI: -0.27 - -0.06, p = 0.001). In the subgroup analysis, the time for union in the AP group in nonisthmal and isthmal nonunion of lower extremity long bones was shorter compared to the EN group (nonisthmal SMD: -1.94, 95% CI: -3.28 - -0.61, p < 0.001; isthmal SMD: -1.08, 95% CI: -1.64 - -0.52, p = 0.002).
CONCLUSION
In the treatment of nonunion in diaphyseal fractures of the long bones in the lower extremity, the AP approach is superior to EN, both intraoperatively (with reduced duration of the surgical procedure and diminished blood loss) and postoperatively (with an elevated union rate, shorter union time, and lower incidence of complications). Specifically, in the management of nonunion of lower extremity long bones with non-isthmal and isthmal intramedullary nails, AP demonstrated shorter union time in comparison to EN.
Humans
;
Bone Nails/adverse effects*
;
Bone Plates/adverse effects*
;
Femoral Fractures/surgery*
;
Fracture Fixation, Intramedullary/methods*
;
Fractures, Ununited/surgery*
;
Lower Extremity/injuries*
3.Analysis of risk factors, pathogenic bacteria characteristics, and drug resistance of postoperative surgical site infection in adults with limb fractures.
Yan-Jun WANG ; Zi-Hou ZHAO ; Shuai-Kun LU ; Guo-Liang WANG ; Shan-Jin MA ; Lin-Hu WANG ; Hao GAO ; Jun REN ; Zhong-Wei AN ; Cong-Xiao FU ; Yong ZHANG ; Wen LUO ; Yun-Fei ZHANG
Chinese Journal of Traumatology 2025;28(4):241-251
PURPOSE:
We carried out the study aiming to explore and analyze the risk factors, the distribution of pathogenic bacteria, and their antibiotic-resistance characteristics influencing the occurrence of surgical site infection (SSI), to provide valuable assistance for reducing the incidence of SSI after traumatic fracture surgery.
METHODS:
A retrospective case-control study enrolling 3978 participants from January 2015 to December 2019 receiving surgical treatment for traumatic fractures was conducted at Tangdu Hospital of Air Force Medical University. Baseline data, demographic characteristics, lifestyles, variables related to surgical treatment, and pathogen culture were harvested and analyzed. Univariate analyses and multivariate logistic regression analyses were used to reveal the independent risk factors of SSI. A bacterial distribution histogram and drug-sensitive heat map were drawn to describe the pathogenic characteristics.
RESULTS:
Included 3978 patients 138 of them developed SSI with an incidence rate of 3.47% postoperatively. By logistic regression analysis, we found that variables such as gender (males) (odds ratio (OR) = 2.012, 95% confidence interval (CI): 1.235 - 3.278, p = 0.005), diabetes mellitus (OR = 5.848, 95% CI: 3.513 - 9.736, p < 0.001), hypoproteinemia (OR = 3.400, 95% CI: 1.280 - 9.031, p = 0.014), underlying disease (OR = 5.398, 95% CI: 2.343 - 12.438, p < 0.001), hormonotherapy (OR = 11.718, 95% CI: 6.269 - 21.903, p < 0.001), open fracture (OR = 29.377, 95% CI: 9.944 - 86.784, p < 0.001), and intraoperative transfusion (OR = 2.664, 95% CI: 1.572 - 4.515, p < 0.001) were independent risk factors for SSI, while, aged over 59 years (OR = 0.132, 95% CI: 0.059 - 0.296, p < 0.001), prophylactic antibiotics use (OR = 0.082, 95% CI: 0.042 - 0.164, p < 0.001) and vacuum sealing drainage use (OR = 0.036, 95% CI: 0.010 - 0.129, p < 0.001) were protective factors. Pathogens results showed that 301 strains of 38 species of bacteria were harvested, among which 178 (59.1%) strains were Gram-positive bacteria, and 123 (40.9%) strains were Gram-negative bacteria. Staphylococcus aureus (108, 60.7%) and Enterobacter cloacae (38, 30.9%) accounted for the largest proportion. The susceptibility of Gram-positive bacteria to Vancomycin and Linezolid was almost 100%. The susceptibility of Gram-negative bacteria to Imipenem, Amikacin, and Meropenem exceeded 73%.
CONCLUSION
Orthopedic surgeons need to develop appropriate surgical plans based on the risk factors and protective factors associated with postoperative SSI to reduce its occurrence. Meanwhile, it is recommended to strengthen blood glucose control in the early stage of admission and for surgeons to be cautious and scientific when choosing antibiotic therapy in clinical practice.
Humans
;
Surgical Wound Infection/epidemiology*
;
Male
;
Female
;
Risk Factors
;
Retrospective Studies
;
Middle Aged
;
Adult
;
Case-Control Studies
;
Fractures, Bone/surgery*
;
Aged
;
Drug Resistance, Bacterial
;
Logistic Models
;
Anti-Bacterial Agents/therapeutic use*
;
Incidence
;
Bacteria/drug effects*
4.Diagnostic value of ultrasonic shear wave elastography for clinically significant prostate cancer.
Fang-Rui YANG ; Yong-Hao JI ; Li-Tao RUAN ; Jian-Xue LIU ; Yao-Ren ZHANG ; Xiao ZHANG ; Qin-Yun WAN ; Si-Fan REN
National Journal of Andrology 2025;31(6):505-511
OBJECTIVE:
To explore the diagnostic value of shear wave elastography (SWE) for clinically significant prostate cancer (csPCa).
METHODS:
We retrospectively analyzed the clinical data of 359 cases with suspected prostate cancer (PCa) in Baoji Central Hospital from June 2017 to July 2023. All the patients underwent the following examinations in the order of serum prostate-specific antigen (PSA) testing, transrectal ultrasonography (TRUS), measurement of the stiffness of the entire prostate gland by SWE, and TRUS-guided prostate puncture biopsy. The stiffness of the entire prostate gland was defined as the average of Young's modulus at both sides of the base, middle, and apex of the prostate, including the maximum Young's modulus (Emax), mean Young's modulus (Emean), and minimum Young's modulus (Emin). We analyzed the correlation of the parameters of the stiffness of the entire prostate gland with the pathological results, focusing on their diagnostic performance for csPCa.
RESULTS:
Of the 359 cases, 189 were diagnosed by pathological puncture biopsy as BPH, 26 as non-csPCa, and 144 as csPCa. The PSA level, Emax, Emean and Emin were significantly higher in the csPCa than those in the BPH and non-csPCa groups (all P < 0.01), but showed no statistically significant difference between the BPH and non-csPCa groups (all P > 0.05). The area under the receiver operating characteristic curve (AUC), optimal cut-off value, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of Emax in the diagnosis of csPCa were 0.852, 143.92 kPa, 72.22%, 84.65%, 75.91%, 81.98% and 79.67%; those of Emean were 0.868, 82.42 kPa, 67.36%, 91.16%, 83.62%, 80.66% and 81.62%; and those of Emin were 0.682, 32.73 kPa, 47.22%, 89.30%, 73.91%, 71.54% and 72.14%, respectively. In the non-csPCa group, Emax, Emean and Emin were found below the optimal cut-off value in 73.08% (19/26), 92.31% (24/26) and 88.46% (23/26), respectively.
CONCLUSION
The stiffness of the entire prostate gland measured by SWE contributes to the diagnosis of csPCa, reduces unnecessary detection of non-csPCa, and provides some reference for its active surveillance.
Humans
;
Male
;
Prostatic Neoplasms/diagnosis*
;
Elasticity Imaging Techniques
;
Retrospective Studies
;
Prostate/pathology*
;
Prostate-Specific Antigen/blood*
;
Aged
;
Middle Aged
5.Research report of living donor kidney harvesting in Bama miniature pigs with six gene modified
Yong XU ; Xiangyu SONG ; Heng’en WANG ; Shujun YANG ; Zhibo JIA ; Hao WEI ; Shengfeng CHEN ; Mengyi CUI ; Yanling REN ; Jiang PENG ; Shengkun SUN
Organ Transplantation 2024;15(2):229-235
Objective To summarize the experience and practical value of living donor kidney harvesting in Bama miniature pigs with six gene modified. Methods The left kidney of Bama miniature pigs with six gene modified was obtained by living donor kidney harvesting technique. First, the ureter was occluded, and then the inferior vena cava and abdominal aorta were freed. During the harvesting process, the ureter, renal vein and renal artery were exposed and freed in sequence. The vascular forceps were used at the abdominal aorta and inferior vena cava, and the renal artery and vein were immediately perfused with 4℃ renal preservation solution, and stored in ice normal saline for subsequent transplantation. Simultaneously, the donor abdominal aorta and inferior vena cava gap were sutured. The operation time, blood loss, warm and cold ischemia time, postoperative complications and the survival of donors and recipients were recorded. Results The left kidney of the genetically modified pig was successfully harvested. Intraoperative bleeding was 5 mL, warm ischemia time was 45 s, and cold ischemia time was 2.5 h. Neither donor nor recipient pig received blood transfusion, and urinary function of the kidney transplanted into the recipient was recovered. The donor survived for more than 8 months after the left kidney was resected. Conclusions Living donor kidney harvesting is safe and reliable in genetically modified pigs. Branch blood vessels could be processed during kidney harvesting, which shortens the process of kidney repair and the time of cold ischemia. Living donor kidney harvesting contributes to subsequent survival of donors and other scientific researches.
6.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
7.Theoretical Reaction Model Combined with Characteristic MS2 Information for Systematical Detection and Annotation of Novel Theaflavins in Yunnan Black Tea
Yong-Lin LI ; Jie GUO ; Zhi-Hao YU ; Si-Yu LI ; Yong-Dan HU ; Lun-Zhao YI ; Da-Bing REN
Chinese Journal of Analytical Chemistry 2024;52(6):846-855,中插24-中插35
In black tea,theaflavins (TFs) are one important class of substances that determine sensory quality and have significant medicinal activities. In addition to the four kinds of common TFs,there may be many other theaflavin analogues (TFAs) with similar chemical structures in tea,but the study on them is very limited. Based on the characteristic sub-structure,mass spectrometry (MS) and MS/MS information,a method for screening and annotation of TFAs from the complex ultra high performance liquid chromatography-high-resolution mass spectrometry (UPLC-HRMS) data was proposed in this work. By analyzing the oxidation and polymerization process of a few TFs,the theoretical reaction model of TFs were summarized,which was used to calculate the precursor ion values of potential TFAs. Meanwhile,the diagnostic fragmentation ions and neutral loss of TFAs according to the fragmentation pathways obtained from chemical standards or documented in literatures were summarized. As a result,36 kinds of compounds were successfully annotated based on the calculated precursor ion values and the MS fragmentation patterns,among which 6 kinds of compounds were reported for the first time in tea. In vitro synthesis experiments were carried out to verified the annotation results. Based on the results of quantitation of 36 kinds of TFAs,a partial least squares-discriminant analysis model was used to investigate the changes of these components during black tea manufacturing. The results indicated that these novel TFAs could be used to effectively distinguish the black tea samples before and after fermentation.
8.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
9.Moving Epidemic Method for Surveillance and Early Warning of Hand, Foot, and Mouth Disease in Beijing, China.
Shuai Bing DONG ; Yu WANG ; Da HUO ; Hao ZHAO ; Bai Wei LIU ; Ren Qing LI ; Zhi Yong GAO ; Xiao Li WANG ; Dai Tao ZHANG ; Quan Yi WANG ; Lei JIA ; Peng YANG
Biomedical and Environmental Sciences 2023;36(12):1162-1166
10.Research progress of functional alignment robot assisted knee replacement.
Yong-Ze YANG ; Qing-Hao CHENG ; An-Ren ZHANG ; Yi QIU ; Hong-Zhang GUO
China Journal of Orthopaedics and Traumatology 2023;36(11):1106-1110
The correct alignment of the knee joint is considered to be one of the most influential factors in determining the long-term prognosis after total knee arthroplasty(TKA). In order to achieve the correct alignment goal, many different alignment concepts and surgical techniques have been established. For example, mechanical alignment(MA), kinematic alignment(KA) and functional alignment(FA) have their own characteristics. MA focuses on achieving neutral alignment of the limbs, parallel and equal bone gaps during stretching and flexion. KA aims to restore the patient 's natural joint line, make the joint level and angle normal and improve the physiological soft tissue balance, and strive to reproduce the normal knee function;among them, functional alignment(FA) developed with robot-assisted surgery technology is a relatively new alignment concept. It not only considers the alignment of the body, but also aims to achieve flexion and extension balance, while respecting the native soft tissue capsule. It not only restores the plane and slope of the in situ joint line accurately during the operation, but also takes into account the balance of soft tissue, which is a better alignment method. Therefore, it is of great significance to correctly construct the lower limb force line of patients, which is helpful to restore knee joint function, relieve pain symptoms and prolong the service life of prosthesi. However, compared with traditional TKA, the operation time of robot-assisted FA-TKA is prolonged, which means that the probability of postoperative infection will be greater. At present, most studies of FA technology report short-term results, and the long-term efficacy of patients is not clear. Therefore, long-term research results are needed to support the application of this technology. Therefore, the author makes a review on the research status of functional alignment.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Robotics
;
Knee Joint/surgery*
;
Osteoarthritis, Knee/surgery*
;
Knee
;
Knee Prosthesis
;
Biomechanical Phenomena

Result Analysis
Print
Save
E-mail