1.The Valvular Heart Disease-specific Age-adjusted Comorbidity Index (VHD-ACI) score in patients with moderate or severe valvular heart disease.
Mu-Rong XIE ; Bin ZHANG ; Yun-Qing YE ; Zhe LI ; Qing-Rong LIU ; Zhen-Yan ZHAO ; Jun-Xing LV ; De-Jing FENG ; Qing-Hao ZHAO ; Hai-Tong ZHANG ; Zhen-Ya DUAN ; Bin-Cheng WANG ; Shuai GUO ; Yan-Yan ZHAO ; Run-Lin GAO ; Hai-Yan XU ; Yong-Jian WU
Journal of Geriatric Cardiology 2025;22(9):759-774
BACKGROUND:
Based on the China-VHD database, this study sought to develop and validate a Valvular Heart Disease- specific Age-adjusted Comorbidity Index (VHD-ACI) for predicting mortality risk in patients with VHD.
METHODS & RESULTS:
The China-VHD study was a nationwide, multi-centre multi-centre cohort study enrolling 13,917 patients with moderate or severe VHD across 46 medical centres in China between April-June 2018. After excluding cases with missing key variables, 11,459 patients were retained for final analysis. The primary endpoint was 2-year all-cause mortality, with 941 deaths (10.0%) observed during follow-up. The VHD-ACI was derived after identifying 13 independent mortality predictors: cardiomyopathy, myocardial infarction, chronic obstructive pulmonary disease, pulmonary artery hypertension, low body weight, anaemia, hypoalbuminaemia, renal insufficiency, moderate/severe hepatic dysfunction, heart failure, cancer, NYHA functional class and age. The index exhibited good discrimination (AUC, 0.79) and calibration (Brier score, 0.062) in the total cohort, outperforming both EuroSCORE II and ACCI (P < 0.001 for comparison). Internal validation through 100 bootstrap iterations yielded a C statistic of 0.694 (95% CI: 0.665-0.723) for 2-year mortality prediction. VHD-ACI scores, as a continuous variable (VHD-ACI score: adjusted HR (95% CI): 1.263 (1.245-1.282), P < 0.001) or categorized using thresholds determined by the Yoden index (VHD-ACI ≥ 9 vs. < 9, adjusted HR (95% CI): 6.216 (5.378-7.184), P < 0.001), were independently associated with mortality. The prognostic performance remained consistent across all VHD subtypes (aortic stenosis, aortic regurgitation, mitral stenosis, mitral regurgitation, tricuspid valve disease, mixed aortic/mitral valve disease and multiple VHD), and clinical subgroups stratified by therapeutic strategy, LVEF status (preserved vs. reduced), disease severity and etiology.
CONCLUSION
The VHD-ACI is a simple 13-comorbidity algorithm for the prediction of mortality in VHD patients and providing a simple and rapid tool for risk stratification.
2.The Impacts of Climate Change on the Environment and Human Health in China: A Call for more Ambitious Action.
Shi Lu TONG ; Yu WANG ; Yong Long LU ; Cun de XIAO ; Qi Yong LIU ; Qi ZHAO ; Cun Rui HUANG ; Jia Yu XU ; Ning KANG ; Tong ZHU ; Dahe QIN ; Ying XU ; Buda SU ; Xiao Ming SHI
Biomedical and Environmental Sciences 2025;38(2):127-143
As global greenhouse gases continue rising, the urgency of more ambitious action is clearer than ever before. China is the world's biggest emitter of greenhouse gases and one of the countries affected most by climate change. The evidence about the impacts of climate change on the environment and human health may encourage China to take more decisive action to mitigate greenhouse gas emissions and adapt to climate impacts. This article aimed to review the evidence of environmental damages and health risks posed by climate change and to provide a new science-based perspective for the delivery of sustainable development goals. Over recent decades, China has experienced a strong warming pattern with a growing frequency of extreme weather events, and the impacts of climate change on China's environment and human health have been consistently observed, with increasing O 3 air pollution, decreases in water resources and availability, land degradation, and increased risks for both communicable and non-communicable diseases. Therefore, China's climate policy should target the key factors driving climate change and scale up strategic measures to curb carbon emissions and adapt to inevitable increasing climate impacts. It provides new insights for not only China but also other countries, particularly developing and emerging economies, to ensure climate and environmental sustainability whilst pursuing economic growth.
Climate Change
;
China
;
Humans
;
Greenhouse Gases
;
Air Pollution
;
Sustainable Development
;
Environment
3.Application characteristics and modern research progress of "bone-approaching" acupuncture.
De-Hui ZOU ; Kai-Xin FENG ; Hong-Wen LIANG ; Xu-Hao TANG ; Shan ZHAO ; Zi-Jian QIU ; Peng-Yong BAI ; Jia-Mu LIU ; Tong LIU
Chinese Acupuncture & Moxibustion 2023;43(9):1094-1098
The paper explores the evolution of "bone-approaching" acupuncture, its effect target and mechanism. The concrete operation procedure of "bone-approaching" method is recorded originally in Huangdi Neijing (Inner Canon of Yellow Emperor) as short needling and Shu needling (referring to the category of the five needling technique). The periosteum is the most effective stimulation target of "bone-approaching" acupuncture for analgesia, regaining consciousness and regulating spirit. The "bone-approaching" acupuncture is not only prominently effective on bone bi syndrome, but also has the unique effect on painful, encephalogenic and emotional diseases. The paper summarizes and improves "bone-approaching" acupuncture, i.e. "touching bone surface" with needle tip by slow insertion, "touching bone surface" without pain by swift insertion and "touching bone" with needle body by oblique insertion. It contributes to the inheritance, development and supplementation to the bone needling techniques in Huangdi Neijing and is significant for broadening the clinical application range of acupuncture.
Humans
;
Acupuncture Therapy
;
Periosteum
;
Analgesia
;
Pain Management
;
Consciousness
;
Pain
4.Development and validation of a score predicting mortality for older patients with mitral regurgitation.
De-Jing FENG ; Yun-Qing YE ; Zhe LI ; Bin ZHANG ; Qing-Rong LIU ; Wei-Wei WANG ; Zhen-Yan ZHAO ; Zheng ZHOU ; Qing-Hao ZHAO ; Zi-Kai YU ; Hai-Tong ZHANG ; Zhen-Ya DUAN ; Bin-Cheng WANG ; Jun-Xing LV ; Shuai GUO ; Run-Lin GAO ; Hai-Yan XU ; Yong-Jian WU
Journal of Geriatric Cardiology 2023;20(8):577-585
OBJECTIVE:
To develop and validate a user-friendly risk score for older mitral regurgitation (MR) patients, referred to as the Elder-MR score.
METHODS:
The China Senile Valvular Heart Disease (China-DVD) Cohort Study functioned as the development cohort, while the China Valvular Heart Disease (China-VHD) Study was employed for external validation. We included patients aged 60 years and above receiving medical treatment for moderate or severe MR (2274 patients in the development cohort and 1929 patients in the validation cohort). Candidate predictors were chosen using Cox's proportional hazards model and stepwise selection with Akaike's information criterion.
RESULTS:
Eight predictors were identified: age ≥ 75 years, body mass index < 20 kg/m2, NYHA class III/IV, secondary MR, anemia, estimated glomerular filtration rate < 60 mL/min per 1.73 m2, albumin < 35 g/L, and left ventricular ejection fraction < 60%. The model displayed satisfactory performance in predicting one-year mortality in both the development cohort (C-statistic = 0.73, 95% CI: 0.69-0.77, Brier score = 0.06) and the validation cohort (C-statistic = 0.73, 95% CI: 0.68-0.78, Brier score = 0.06). The Elder-MR score ranges from 0 to 15 points. At a one-year follow-up, each point increase in the Elder-MR score represents a 1.27-fold risk of death (HR = 1.27, 95% CI: 1.21-1.34, P < 0.001) in the development cohort and a 1.24-fold risk of death (HR = 1.24, 95% CI: 1.17-1.30, P < 0.001) in the validation cohort. Compared to EuroSCORE II, the Elder-MR score demonstrated superior predictive accuracy for one-year mortality in the validation cohort (C-statistic = 0.71 vs. 0.70, net reclassification improvement = 0.320, P < 0.01; integrated discrimination improvement = 0.029, P < 0.01).
CONCLUSIONS
The Elder-MR score may serve as an effective risk stratification tool to assist clinical decision-making in older MR patients.
5.Catheter ablation versus medical therapy for atrial fibrillation with prior stroke history: a prospective propensity score-matched cohort study.
Wen-Li DAI ; Zi-Xu ZHAO ; Chao JIANG ; Liu HE ; Ke-Xin YAO ; Yu-Feng WANG ; Ming-Yang GAO ; Yi-Wei LAI ; Jing-Rui ZHANG ; Ming-Xiao LI ; Song ZUO ; Xue-Yuan GUO ; Ri-Bo TANG ; Song-Nan LI ; Chen-Xi JIANG ; Nian LIU ; De-Yong LONG ; Xin DU ; Cai-Hua SANG ; Jian-Zeng DONG ; Chang-Sheng MA
Journal of Geriatric Cardiology 2023;20(10):707-715
BACKGROUND:
Patients with atrial fibrillation (AF) and prior stroke history have a high risk of cardiovascular events despite anticoagulation therapy. It is unclear whether catheter ablation (CA) has further benefits in these patients.
METHODS:
AF patients with a previous history of stroke or systemic embolism (SE) from the prospective Chinese Atrial Fibrillation Registry study between August 2011 and December 2020 were included in the analysis. Patients were matched in a 1:1 ratio to CA or medical treatment (MT) based on propensity score. The primary outcome was a composite of all-cause death or ischemic stroke (IS)/SE.
RESULTS:
During a total of 4.1 ± 2.3 years of follow-up, the primary outcome occurred in 111 patients in the CA group (3.3 per 100 person-years) and in 229 patients in the MT group (5.7 per 100 person-years). The CA group had a lower risk of the primary outcome compared to the MT group [hazard ratio (HR) = 0.59, 95% CI: 0.47-0.74, P < 0.001]. There was a significant decreasing risk of all-cause mortality (HR = 0.43, 95% CI: 0.31-0.61, P < 0.001), IS/SE (HR = 0.73, 95% CI: 0.54-0.97, P = 0.033), cardiovascular mortality (HR = 0.32, 95% CI: 0.19-0.54, P < 0.001) and AF recurrence (HR = 0.33, 95% CI: 0.30-0.37, P < 0.001) in the CA group compared to that in the MT group. Sensitivity analysis generated consistent results when adjusting for time-dependent usage of anticoagulants.
CONCLUSIONS
In AF patients with a prior stroke history, CA was associated with a lower combined risk of all-cause death or IS/SE. Further clinical trials are warranted to confirm the benefits of CA in these patients.
6.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
7.Establishment of an animal model of Sparganum mansoni infection and study on therapeutic methods II Establishment of a mouse model of sparganosis mansoni via oral administration of procercoids
Xian-shi TANG ; Yong-liang XU ; Qiang WANG ; Ying ZHANG ; De-sheng TONG
Chinese Journal of Schistosomiasis Control 2022;34(4):400-403
Objective To establish an animal model of sparganosis mansoni through oral administration of Cyclops infected with procercoids. Methods Domestic cats were infected with Sparganum mansoni under laboratory conditions, and fresh cat stool samples were collected, washed in dechlorinated water, and filtered. Spirometra mansoni eggs were collected and prepared into suspensions. Twenty C57BL/6j mice were randomly divided into the experimental group (n = 15) and the control group (n = 5). Wild Cyclops were infected with Spirometra mansoni coracidia to allow 3 to 5 procercoids in each Cyclop. Then, each mouse in the experimental group was given 15 Cyclops infected with procercoids by gavage, while mice in the control group were orally administered with the same volume of dechlorinated water. All mice were sacrificed after 5 months, and dissected, and suspicious Sparganum mansoni worms were collected. The serum specific IgG antibody against Sparganum mansoni was measured in mice using enzyme-linked immunosorbent assay (ELISA). Genomic DNA was isolated from suspicious Sparganum mansoni worms, and the specific Sparganum mansoni cytochrome oxidase I (COI) gene was amplified using PCR assay. Results Among the 15 mice in the experimental group, six were positive for the serum specific IgG antibody against Sparganum mansoni, and milky white worms were found and collected from the subcutaneous regions of 4 out of 6 mice. Only one worm was detected in each mouse, and the worm morphology was similar to Sparganum mansoni. Capillary electrophoresis of the PCR amplification products of COI gene presented a specific band with 151 bp in size, and sequencing analysis revealed 100% homology with Sparganum mansoni. Conclusions A mouse model of sparganosis mansoni is successfully created through oral administration of Cyclops infected with Spirometra mansoni procercoids.
8.Expert consensus on rational usage of nebulization treatment on childhood respiratory system diseases.
Han Min LIU ; Zhou FU ; Xiao Bo ZHANG ; Hai Lin ZHANG ; Yi Xiao BAO ; Xing Dong WU ; Yun Xiao SHANG ; De Yu ZHAO ; Shun Ying ZHAO ; Jian Hua ZHANG ; Zhi Min CHEN ; En Mei LIU ; Li DENG ; Chuan He LIU ; Li XIANG ; Ling CAO ; Ying Xue ZOU ; Bao Ping XU ; Xiao Yan DONG ; Yong YIN ; Chuang Li HAO ; Jian Guo HONG
Chinese Journal of Pediatrics 2022;60(4):283-290
9.Naoxintong Capsule for Secondary Prevention of Ischemic Stroke: A Multicenter, Randomized, and Placebo-Controlled Trial.
Xiao-Fei YU ; Xu-Ying ZHU ; Can-Xing YUAN ; Dan-Hong WU ; Yu-Wu ZHAO ; Jia-Jun YANG ; Chang-de WANG ; Wei-Wen WU ; Xue-Yuan LIU ; Zhen-Guo LIU ; Zhi-Yu NIE ; Ben-Qiang DENG ; Huan BAO ; Long-Xuan LI ; Chun-Yan WANG ; Hong-Zhi ZHANG ; Jing-Si ZHANG ; Ji-Han HUANG ; Fan GONG ; Ming-Zhe WANG ; Yong-Mei GUO ; Yan SUN ; Ding-Fang CAI
Chinese journal of integrative medicine 2022;28(12):1063-1071
OBJECTIVE:
To examine whether the combination of Naoxintong Capsule with standard care could further reduce the recurrence of ischemic stroke without increasing the risk of severe bleeding.
METHODS:
A total of 23 Chinese medical centers participated in this trial. Adult patients with a history of ischemic stroke were randomly assigned in a 1:1 ratio using a block design to receive either Naoxintong Capsule (1.2 g orally, twice a day) or placebo in addition to standard care. The primary endpoint was recurrence of ischemic stroke within 2 years. Secondary outcomes included myocardial infarction, death due to recurrent ischemic stroke, and all-cause mortality. The safety of drugs was monitored. Results were analyzed using the intention-to-treat principle.
RESULTS:
A total of 2,200 patients were enrolled from March 2015 to March 2016, of whom 143 and 158 in the Naoxintong and placebo groups were lost to follow-up, respectively. Compared with the placebo group, the recurrence rate of ischemic stroke within 2 years was significantly lower in the Naoxintong group [6.5% vs. 9.5%, hazard ratio (HR): 0.665, 95% confidence interval (CI): 0.492-0.899, P=0.008]. The two groups showed no significant differences in the secondary outcomes and safety, including rates of severe hemorrhage, cerebral hemorrhage and subarachnoid hemorrhage (P>0.05).
CONCLUSION
The combination of Naoxintong Capsule with standard care reduced the 2-year stroke recurrence rate in patients with ischemic stroke without increasing the risk of severe hemorrhage in high-risk patients. (Trial registration No. NCT02334969).
Adult
;
Humans
;
Secondary Prevention/methods*
;
Ischemic Stroke
;
Stroke/prevention & control*
;
Cerebral Hemorrhage/complications*
;
Double-Blind Method
;
Platelet Aggregation Inhibitors
10.A comparison of CAS risk model and CHA2DS2-VASc risk model in guiding anticoagulation treatment in Chinese patients with non-valvular atrial fibrillation.
Jia Long DENG ; Liu HE ; Chao JIANG ; Yi Wei LAI ; De Yong LONG ; Cai Hua SANG ; Chang Qi JIA ; Li FENG ; Xu LI ; Man NING ; Rong HU ; Jian Zeng DONG ; Xin DU ; Ri Bo TANG ; Chang Sheng MA
Chinese Journal of Cardiology 2022;50(9):888-894
Objective: To compare the differences between CAS risk model and CHA2DS2-VASc risk score in predicting all cause death, thromboembolic events, major bleeding events and composite endpoint in patients with nonvalvular atrial fibrillation. Methods: This is a retrospective cohort study. From the China Atrial Fibrillation Registry cohort study, the patients with atrial fibrillation who were>18 years old were randomly divided into CAS risk score group and CHA2DS2-VASc risk score group respectively. According to the anticoagulant status at baseline and follow-up, patients in the 2 groups who complied with the scoring specifications for anticoagulation were selected for inclusion in this study. Baseline information such as age and gender in the two groups were collected and compared. Follow-up was performed periodically to collect information on anticoagulant therapy and endpoints. The endpoints were all-cause death, thromboembolism events and major bleeding, the composite endpoint events were all-cause death and thromboembolism events. The incidence of endpoints in CAS group and CHA2DS2-VASc group was analyzed, and multivariate Cox proportional risk model was used to analyze whether the incidence of the endpoints was statistically different between the two groups. Results: A total of 5 206 patients with AF were enrolled, average aged (63.6±12.2) years, and 2092 (40.2%) women. There were 2 447 cases (47.0%) in CAS risk score group and 2 759 cases (53.0%) in CHA2DS2-VASc risk score group. In the clinical baseline data of the two groups, the proportion of left ventricular ejection fraction<55%, non-paroxysmal atrial fibrillation, oral warfarin and HAS BLED score in the CAS group were lower than those in the CHA2DS2-VASc group, while the proportion of previous diabetes history and history of antiplatelet drugs in the CAS group was higher than that in the CHA2DS2-VASc group, and there was no statistical difference in other baseline data. Patients were followed up for (82.8±40.8) months. In CAS risk score group, 225(9.2%) had all-cause death, 186 (7.6%) had thromboembolic events, 81(3.3%) had major bleeding, and 368 (15.0%) had composite endpoint. In CHA2DS2-VASc risk score group, 261(9.5%) had all-cause death 209(7.6%) had thromboembolic events, 112(4.1%) had major bleeding, and 424 (15.4%) had composite endpoint. There were no significant differences in the occurrence of all-cause death, thromboembolic events, major bleeding and composite endpoint between anticoagulation in CAS risk score group and anticoagulation in CHA2DS2-VASc risk score group (log-rank P =0.643, 0.904, 0.126, 0.599, respectively). Compared with CAS risk score, multivariable Cox proportional hazards regression models showed no significant differences for all-cause death, thromboembolic events, major bleeding and composite endpoint between the two groups with HR(95%CI) 0.95(0.80-1.14), 1.00(0.82-1.22), 0.83(0.62-1.10), 0.96(0.84-1.11), respectively. All P>0.05. Conclusions: There were no significant differences between CAS risk model and CHA2DS2-VASc risk score in predicting all-cause death, thromboembolic events, and major bleeding events in Chinese patients with non-valvular atrial fibrillation.
Adolescent
;
Anticoagulants
;
Atrial Fibrillation/drug therapy*
;
Cohort Studies
;
Female
;
Hemorrhage/complications*
;
Humans
;
Male
;
Retrospective Studies
;
Risk Assessment
;
Stroke/epidemiology*
;
Stroke Volume
;
Thromboembolism/etiology*
;
Ventricular Function, Left

Result Analysis