1.The Invariant Neural Representation of Neurons in Pigeon’s Ventrolateral Mesopallium to Stereoscopic Shadow Shapes
Xiao-Ke NIU ; Meng-Bo ZHANG ; Yan-Yan PENG ; Yong-Hao HAN ; Qing-Yu WANG ; Yi-Xin DENG ; Zhi-Hui LI
Progress in Biochemistry and Biophysics 2025;52(10):2614-2626
ObjectiveIn nature, objects cast shadows due to illumination, forming the basis for stereoscopic perception. Birds need to adapt to changes in lighting (meaning they can recognize stereoscopic shapes even when shadows look different) to accurately perceive different three-dimensional forms. However, how neurons in the key visual brain area in birds handle these lighting changes remains largely unreported. In this study, pigeons (Columba livia) were used as subjects to investigate how neurons in pigeon’s ventrolateral mesopallium (MVL) represent stereoscopic shapes consistently, regardless of changes in lighting. MethodsVisual cognitive training combined with neuronal recording was employed. Pigeons were first trained to discriminate different stereoscopic shapes (concave/convex). We then tested whether and how light luminance angle and surface appearance of the stereoscopic shapes affect their recognition accuracy, and further verify whether the results rely on specify luminance color. Simultaneously, neuronal firing activity of neurons was recorded with multiple electrode array implanted from the MVL during the presentation of difference shapes. The response was finally analyzed how selectively they responded to different stereoscopic shapes and whether their selectivity was affected by the changes of luminance condition (like lighting angle) or surface look. Support vector machine (SVM) models were trained on neuronal population responses recorded under one condition (light luminance angle of 45°) and used to decode responses under other conditions (light luminance angle of 135°, 225°, 315°) to verify the invariance of responses to different luminance conditions. ResultsBehavioral results from 6 pigeons consistently showed that the pigeons could reliably identify the core 3D shape (over 80% accuracy), and this ability wasn’t affected by changes in light angle or surface appearance. Statistical analysis of 88 recorded neurons from 6 pigeons revealed that 83% (73/88) showed strong selectivity for specific 3D shapes (selectivity index>0.3), and responses to convex shapes were consistently stronger than to concave shapes. These shape-selective responses remained stable across changes in light angle and surface appearance. Neural patterns were consistent under both blue and orange lighting. The decoding accuracy achieves above 70%, suggesting stable responses under different conditions (e.g., different lighting angles or surface appearance). ConclusionNeurons in the pigeon MVL maintain a consistent neural encoding pattern for different stereoscopic shapes, unaffected by illumination or surface appearance. This ensures stable object recognition by pigeons in changing visual environments. Our findings provide new physiological evidence for understanding how birds achieve stable perception (“invariant neural representations”) while coping with variations in the visual field.
2.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
3.Redo-Bentall surgery for aortic root lesions:a report of case series
Xiaobo PENG ; Fan LI ; Tianbo LI ; Chencheng LIU ; Bo XU ; Han XIA ; Yingbin XIAO ; Yong WANG
Journal of Army Medical University 2024;46(10):1158-1163
Objective To observe the clinical efficacy of Redo-Bentall surgery in the reoperation of aortic root lesions.Methods A retrospective analysis was performed on 46 patients who underwent Redo-Bentall surgery for aortic root lesions in our department from June 2010 to April 2022.They were 35 males and 11 females,at a mean age of 43.37±12.79 years,in 4.96±6.76 years since the last operation.General clinical data in perioperative period and during follow-up were collected and analyzed.Kaplan-Meier survival analysis was used to compare the survival rates of each etiological group.Results There were 9 cases of central end otitis,12 cases of Behset's disease,and 25 cases of other causes.After operation,4 cases(8.70%)experienced cardiac arrest,4 cases(8.70%)renal failure,2 cases(4.35%)gastrointestinal bleeding,2 cases(4.35%)new third-degree atrioventricular block and 2 cases(4.35%)permanent pacemaker placement.In perioperative period,3 cases(6.52%)died in hospital.During a mean follow-up of 5.03±3.27 years after discharge,5 cases(11.63%)were lost to follow-up,1 case died(2.33%),1 case had lacunar infarction(2.33%),and no severe bleeding or embolism complications was observed in the rest patients.The long-term survival rate was significantly lower in the endocarditis group(62.3%)and the Behcet's disease group(70%)than the other etiological groups(80%,P<0.05).Conclusion The application of Redo-Bentall in the reoperation of aortic root lesions is safe and effective,but the survival rate is quite lower in the patients with infective endocarditis and Behcet's disease.
4.Development and Application of Portable Multi-wavelength Spectroscopic Rapid Detector for Organic Pollutants
Yu-Ping CHEN ; Jia-Chuan PAN ; Yong-Qian LEI ; Chang-Yu LIU ; Jian-Bo JIA ; Peng-Ran GUO
Chinese Journal of Analytical Chemistry 2024;52(5):653-663,中插1-中插9
A portable multi-wavelength spectral detector was developed for on-site,rapid and accurate detection of organic pollutants in surface water using ultraviolet light-emitting diodes(UV-LEDs)and the corresponding spectral detection method was built.By measuring the fluorescence spectrum and absorption light intensity and combining with the multi-wavelength spectral correlation calculation method to analyze the target,the developed detector was able to qualitatively and quantitatively detect organic pollutants that responded in the UV-light range of 260-370 nm.The proposed detector was used to detect polycyclic aromatic hydrocarbons(PAHs)and Rhodamine B.The linear ranges of anthracene and Rhodamine B in absorption mode were 10-100 and 8.5-100 mg/L,respectively.In fluorescence mode,the linear ranges for anthracene and Rhodamine B were 0.006-50 and 0.02-0.781 mg/L,correspondingly.The absorption/fluorescence concurrent mode could extend the detection ranges of anthracene and Rhodamine B to 0.006-100 and 0.02-100 mg/L,respectively.The recoveries of PAHs in surface water ranged from 97.4%to 105.1%for anthracene and 84.5%to 91.2%for anthracene,naphthalene,and pyrene in absorption and fluorescence modes,respectively.The method was accurate in both modes.The mixtures containing PAHs were identified by the proposed method under the optimized multi-wavelength spectral correlation calculation.The results demonstrated that the method could achieve a similarity of 75%or more when identifying two different concentrations of solutions containing a single or a mixture of targets within the linear concentration range of the targets.However,the similarity dropped to less than 25%when identifying two solutions of different substances.The proposed method had excellent recognition abilityof targets.The proposed detector and method combined fluorescence and absorption spectroscopy,which could expand the application of spectroscopy in the in situ rapid identification and detection of pollutants such as PAHs in surface water.
5.CHEN Bo-Lai's Experience in Treating Low Back Pain of Kidney Deficiency and Phlegm Obstruction Type Based on the Theory of Kidney Being the Root of Phlegm
Wen-Xi SUN ; Qi PENG ; Yu-Fu HUANG ; Jiang-Nan YE ; Hong-Mei LI ; Yong-Peng LIN ; Hong-Shen WANG ; Bo-Lai CHEN
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(6):1616-1620
The kidney governs water and is the congenital foundation.The kidney plays an important role in the transportation and distribution of body fluid,has the interior-exterior relationship with the waterffu-organ bladder,and has the meridian connection with the stomach,the reservoir of water and food,through the thoroughfare vessel.Therefore,the kidney plays a key role in the formation of phlegm.Professor CHEN Bo-Lai believes that low back pain of kidney deficiency and phlegm obstruction type is characterized by deficiency in the origin and excess in the superficiality.Excess in the superficiality is manifested as phlegm obstruction,and deficiency in the origin is manifested as kidney deficiency.Clinically,the patients with low back pain of kidney deficiency and phlegm obstruction type mainly have the manifestations of lumbosacral dull pain and fixed pain,stiffness in the waist,limb numbness or hemiplegia,accompanied by soreness and weakness of waist and knees,and preference for pressing and kneading.The treatment of low back pain of kidney deficiency and phlegm obstruction type can be based on theory of kidney being the root of phlegm,follows the therapy of tonifying kidney and eliminating phlegm,and can be performed by the modified use of basic prescription of Litan Decoction(mainly composed of Euryales Semen,Pinelliae Rhizoma,Sesami Semen Nigrum,Platycladi Semen,Paeoniae Radix Alba,Citri Reticulatae Pericarpium and Poria)together with the assistance of herbs for strengthening spleen and dispersing lung based on the differentiation of the complicated symptoms.The thoughts of Professor CHEN Bo-Lai for the differentiation and treatment of low back pain of kidney deficiency and phlegm obstruction type can be used as a reference for the treatment of low back pain with Chinese medicine.
6.Utilization of endoclip papilloplasty in endoscopic retrograde cholangiopancreatography
Duoqiang ZHANG ; Bo PENG ; Jing LIU ; Guojun XIN ; Xiaojun HU ; Yong YANG ; Chengqiang HAO ; Xiaoyan ZHANG
China Journal of Endoscopy 2024;30(6):1-7
Objective To explore the clinical utility of endoclip papilloplasty in endoscopic retrograde cholangiopancreatography(ERCP).Methods A prospective study was conducted and selected 62 patients who underwent ERCP from November 2021 to November 2022.30 out of 32 patients who randomly underwent endoclip papilloplasty were successful.These patients were assigned to successful endoclip papilloplasty group(group A,n=30)or the duodenal papilla unclamping group(group B,n=30).The aim was to compare the difference in short-term and long-term complications between the two groups.Results The success rate of papillary plasty was 93.8%(30/32),with no statistically significant differences observed in the incidence of postoperative pancreatitis,postoperative hemorrhage after ERCP,and postoperative cholangitis between the two groups(P>0.05).The duodenal perforation rate was 0.There were no significant differences between the two groups in terms of total cholangitis incidence and recurrence rate of calculus of common bile duct within 1 year(P>0.05).However,there was a statistical difference in terms of total the incidence of cholangitis+calculus of common bile duct recurrence within 1 year(P<0.05).Conclusion The endoclip papilloplasty exhibits a high success rate and safety and feasibility procedure reducing long-term recurrence rate of cholangitis and calculus of common bile duct in endoscopic papillary large balloon dilation(EPLBD)procedure.
7.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
Objective:
Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS.
Methods:
An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model.
Results:
The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model.
Conclusion
The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence.
8.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
Objective:
Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS.
Methods:
An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model.
Results:
The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model.
Conclusion
The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence.
9.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
Objective:
Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS.
Methods:
An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model.
Results:
The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model.
Conclusion
The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence.
10.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
Objective:
Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS.
Methods:
An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model.
Results:
The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model.
Conclusion
The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence.

Result Analysis
Print
Save
E-mail