1.Clinical Practice Guideline for the Prehospital Stage of Acute Stroke : III. Initial Decision for Primary Treatment in Subarachnoid Hemorrhage
Jae Sang OH ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Yuna JO ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Dae-Won KIM ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):35-50
Subarachnoid hemorrhage (SAH) is a stroke subtype with high mortality and poor functional outcomes. Prompt occlusion of a ruptured aneurysm at an early stage is crucial to prevent rebleeding, which can result in even higher mortality and more severe disabilities. The most critical initial decision in SAH management is the choice of treatment method with surgical clipping or endovascular coiling. We aimed to develop an evidence-based clinical guideline to select the optimal initial treatment in patients with SAH. We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer two population, intervention, comparison, outcome questions comparing clipping and coiling. The risk of bias was assessed using ROB 2.0 and the Newcastle-Ottawa Scale. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcome and mortality. We included six randomized control trials (RCTs) and 58 observational studies. Meta-analysis of RCTs showed that coiling improved functional outcomes compared to clipping (odds ratio [OR], 0.91; 95% confidence interval [CI], 0.86–0.97). No significant mortality difference was observed in RCTs (OR, 1.38; 95% CI, 0.91–2.09), but non-RCTs favored clipping for reduced mortality (OR, 0.77; 95% CI, 0.69–0.86). However, it is difficult to generalize these findings to all clinical situations, as patients with SAH have a highly variable clinical course. Final treatment decision should be tailored to the individual patient’s status, including aneurysm location, morphology, and the expertise available at the treatment center. Such decisions are best made by specialists such as a board-certified physician and should be explained to the patient and their caregivers, along with the rationale for selecting the most appropriate treatment at the given hospital. Korea has many certified endovascular neurosurgeons, cerebrovascular surgeons, and certified cerebrovascular centers. Proper selection of the most suitable treatment method by certified physicians and centers would greatly benefit patient outcomes and healthcare professionals.
2.Clinical Practice Guidelines for the Prehospital Stage of Acute Stroke in Korea II : Transport Decisions for Patients with Acute Ischemic Stroke
Jae Sang OH ; Yuna JO ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):23-34
The mothership (MS) model, where patients are directly transferred to a thrombectomy-capable center, and the drip-and-ship (DS) model, where thrombolysis is initiated at the nearest primary stroke center before transfer for thrombectomy, are the primary transport modes for patients with stroke. We aimed to establish guidelines for selecting the appropriate transfer strategy based on emergent large vessel occlusion (LVO). We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer three Population, Intervention, Comparison, and Outcome questions comparing MS and DS models. The risk of bias was assessed using the Newcastle-Ottawa Scale. Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcomes, mortality, and successful recanalization. Twenty-six non-randomized controlled studies showed that the MS model improved good functional outcomes by approximately 14% compared with the DS model (odds ratio [OR], 1.14; 95% confidence interval [CI], 1.00–1.30). Fifteen studies reported that mortality in the MS and DS models showed no significant differences (OR, 0.97; 95% CI, 0.84–1.11). Twenty-four studies revealed no significant difference in successful recanalization between the MS and DS models (OR, 0.87; 95% CI, 0.68–1.10). The MS model should be considered first to improve the functional outcome of patients with LVO. However, if thrombectomy cannot be performed immediately after thrombolysis, or if a thrombectomy-enabled hospital is not nearby, the DS model should be considered by stroke specialists depending on transportation time and regional factors. We suggest a mixed approach with the DS model based on specific circumstances or regions to ensure the optimum treatment of patients with acute ischemic stroke (AIS). Appropriate transport for patients with LVO improves the prognosis of AIS.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System
Hyewon PARK ; Yu-Whan OH ; Ki Yeol LEE ; Hwan Seok YONG ; Cherry KIM ; Sung Ho HWANG
Journal of the Korean Society of Radiology 2024;85(2):297-307
Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.
8.Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System
Hyewon PARK ; Yu-Whan OH ; Ki Yeol LEE ; Hwan Seok YONG ; Cherry KIM ; Sung Ho HWANG
Journal of the Korean Society of Radiology 2024;85(2):297-307
Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.
9.Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System
Hyewon PARK ; Yu-Whan OH ; Ki Yeol LEE ; Hwan Seok YONG ; Cherry KIM ; Sung Ho HWANG
Journal of the Korean Society of Radiology 2024;85(2):297-307
Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.
10.JAK2 Loss Arising From Tumor-SpreadThrough-Air-Spaces (STAS) Promotes Tumor Progression by Suppressing CD8+ T Cells in Lung Adenocarcinoma:A Machine Learning Approach
Soohwan CHOI ; Hyung Suk KIM ; Kyueng-Whan MIN ; Yung-Kyun NOH ; Jeong-Yeon LEE ; Ji-Yong MOON ; Un Suk JUNG ; Mi Jung KWON ; Dong-Hoon KIM ; Byoung Kwan SON ; Jung Soo PYO ; Sun Kyun RO
Journal of Korean Medical Science 2024;39(2):e16-
Background:
Tumor spread through air spaces (STAS) is a recently discovered risk factor for lung adenocarcinoma (LUAD). The aim of this study was to investigate specific genetic alterations and anticancer immune responses related to STAS. By using a machine learning algorithm and drug screening in lung cancer cell lines, we analyzed the effect of Janus kinase 2 (JAK2) on the survival of patients with LUAD and possible drug candidates.
Methods:
This study included 566 patients with LUAD corresponding to clinicopathological and genetic data. For analyses of LUAD, we applied gene set enrichment analysis (GSEA), in silico cytometry, pathway network analysis, in vitro drug screening, and gradient boosting machine (GBM) analysis.
Results:
The patients with STAS had a shorter survival time than those without STAS (P < 0.001). We detected gene set-related downregulation of JAK2 associated with STAS using GSEA. Low JAK2 expression was related to poor prognosis and a low CD8+ T-cell fraction. In GBM, JAK2 showed improved survival prediction performance when it was added to other parameters (T stage, N stage, lymphovascular invasion, pleural invasion, tumor size). In drug screening, mirin, CCT007093, dihydroretenone, and ABT737 suppressed the growth of lung cancer cell lines with low JAK2 expression.
Conclusion
In LUAD, low JAK2 expression linked to the presence of STAS might serve as an unfavorable prognostic factor. A relationship between JAK2 and CD8+ T cells suggests that STAS is indirectly related to the anticancer immune response. These results may contribute to the design of future experimental research and drug development programs for LUAD with STAS.

Result Analysis
Print
Save
E-mail