1.Effect of Helicobacter pylori Eradication on Metabolic Parameters and Body Composition including Skeletal Muscle Mass: A Matched Case-Control Study
Suh Eun BAE ; Kee Don CHOI ; Jaewon CHOE ; Min Jung LEE ; Seonok KIM ; Ji Young CHOI ; Hana PARK ; Jaeil KIM ; Hye Won PARK ; Hye-Sook CHANG ; Hee Kyong NA ; Ji Yong AHN ; Kee Wook JUNG ; Jeong Hoon LEE ; Do Hoon KIM ; Ho June SONG ; Gin Hyug LEE ; Hwoon-Yong JUNG
Gut and Liver 2025;19(3):346-354
Background/Aims:
Findings on the impact of Helicobacter pylori eradication on metabolic parameters are inconsistent. This study aimed to evaluate the effects of H. pylori eradication on metabolic parameters and body composition, including body fat mass and skeletal muscle mass.
Methods:
We retrospectively reviewed the data of asymptomatic patients who underwent health screenings, including bioelectrical impedance analysis, before and after H. pylori eradication between 2005 and 2021. After matching individuals based on key factors, we compared lipid profiles, metabolic parameters, and body composition between 823 patients from the eradicated group and 823 patients from the non-eradicated groups.
Results:
Blood pressure, erythrocyte sedimentation rate, and glycated hemoglobin values were significantly lower in the eradicated group than in the non-eradicated group. However, changes in body mass index (BMI), body fat mass, appendicular skeletal muscle mass (ASM), waist circumference, and lipid profiles were not significantly different between the two groups. In a subgroup analysis of individuals aged >45 years, blood pressure, erythrocyte sedimentation rate, and glycated hemoglobin changes were significantly lower in the eradicated group than in the noneradicated group. BMI values were significantly higher in the eradicated group than in the noneradicated group; however, no significant differences were observed between the two groups regarding changes in body weight, body fat mass, ASM, or waist circumference. Total cholesterol and low-density lipoprotein cholesterol levels were significantly lower in the eradicated group than in non-eradicated group.
Conclusions
H. pylori eradication significantly reduced blood pressure, glucose levels, and systemic inflammation and improved lipid profiles in patients aged >45 years. BMI, body fat mass, ASM, and waist circumference did not significantly differ between patients in the eradicated group and those in the non-eradicated group.
2.Diagnosing Complete Response to Preoperative Chemoradiation in Esophageal Cancer Using Dynamic Contrast-Enhanced MRI Response Criteria
Yura AHN ; Jooae CHOE ; Hyun Joo LEE ; Sook Ryun PARK ; Jong-Hoon KIM ; Ho June SONG ; Min-Ju KIM ; Yong-Hee KIM
Korean Journal of Radiology 2025;26(3):269-280
Objective:
To assess the performance of novel qualitative diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to identify the pathologic complete response (pCR) of primary tumors in esophageal cancer after neoadjuvant chemoradiation (nCRT).
Materials and Methods:
Patients who underwent nCRT, subsequent MRI, positron emission tomography/computed tomography (PET/CT), endoscopy, or esophagectomy for esophageal cancer between October 2021 and October 2023 were retrospectively analyzed. The DCE-MRI response of primary tumors was interpreted using five grades by thoracic radiologists as follows: G1 (compatible with CR), G2 (probable CR), G3 (probable partial response [PR]), G4 (compatible with PR), and G5 (stable or progressive disease). The performances of MRI, PET/CT, endoscopy, and their combinations in diagnosing pCR in primary tumors were calculated.
Results:
A total of 52 patients (male:female, 46:6; age, 61.2 ± 8.0 years) were included. Surgical specimens revealed pCR (ypT0) in 34 patients. G1 as the MRI criterion for pCR of primary tumors yielded a positive predictive value (PPV), specificity of 100% (18/18), and low sensitivity (23.5% [8/34]). Combining G1 and G2 as the MRI criteria increased the sensitivity to 73.5% (25/34), with a specificity of 88.9% (16/18), accuracy of 78.8% (41/52), and PPV of 92.6% (25/27). Adding the DCEMRI results (G1-2) significantly improved accuracy for both PET/CT (from 65.4% [34/52] to 80.8% [42/52], P = 0.03) and endoscopy (from 55.8% [29/52] to 76.9% [40/52], P = 0.005), with increase in sensitivity (from 55.9% [19/34] to 82.4% [28/34] for PET/CT-based evaluation [P = 0.008] and from 47.1% [16/34] to 82.4% [28/34] for endoscopy-based evaluation [P = 0.001]).
Conclusion
DCE-MRI-based grading shows high diagnostic performance for identifying pCR in primary tumors, particularly in terms of PPV and specificity, and enhances response evaluation when combined with PET/CT and endoscopy.
3.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
4.Environmental disease monitoring by regional Environmental Health Centers in Korea: a narrative review
Myung-Sook PARK ; Hwan-Cheol KIM ; Woo Jin KIM ; Yun-Chul HONG ; Won-Jun CHOI ; Seock-Yeon HWANG ; Jiho LEE ; Young-Seoub HONG ; Yong-Dae KIM ; Seong-Chul HONG ; Joo Hyun SUNG ; Inchul JEONG ; Kwan LEE ; Won-Ju PARK ; Hyun-Joo BAE ; Seong-Yong YOON ; Cheolmin LEE ; Kyoung Sook JEONG ; Sanghyuk BAE ; Jinhee CHOI ; Ho-Hyun KIM
The Ewha Medical Journal 2025;48(1):e3-
This study explores the development, roles, and key initiatives of the Regional Environmental Health Centers in Korea, detailing their evolution through four distinct phases and their impact on environmental health policy and local governance. It chronicles the establishment and transformation of these centers from their inception in May 2007, through four developmental stages. Originally named Environmental Disease Research Centers, they were subsequently renamed Environmental Health Centers following legislative changes. The analysis includes the expansion in the number of centers, the transfer of responsibilities to local governments, and the launch of significant projects such as the Korean Children’s Environmental Health Study (Ko-CHENS ). During the initial phase (May 2007–February 2009), the 10 centers concentrated on research-driven activities, shifting from a media-centered to a receptor-centered approach. In the second phase, prompted by the enactment of the Environmental Health Act, six additional centers were established, broadening their scope to address national environmental health issues. The third phase introduced Ko-CHENS, a 20-year national cohort project designed to influence environmental health policy by integrating research findings into policy frameworks. The fourth phase marked a decentralization of authority, empowering local governments and redefining the centers' roles to focus on regional environmental health challenges. The Regional Environmental Health Centers have significantly evolved and now play a crucial role in addressing local environmental health issues and supporting local government policies. Their capacity to adapt and respond to region-specific challenges is essential for the effective implementation of environmental health policies, reflecting geographical, socioeconomic, and demographic differences.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Fasting is not always good: perioperative fasting leads to pronounced ketone body production in patients treated with SGLT2 inhibitors: a case report
Jae Chan CHOI ; Yo Nam JANG ; Jong Hoon LEE ; Sang Wook PARK ; Jeong A PARK ; Hye Sook KIM ; Jae Won CHOI ; Joo Hyung LEE ; Yong Jae LEE
Korean Journal of Family Medicine 2025;46(3):204-209
Ketone bodies produced by sodium-glucose cotransporter 2 (SGLT2) inhibitors can be advantageous, providing an efficient and stable energy source for the brain and muscles. However, in patients with diabetes, ketogenesis induced by SGLT2 inhibitors may be harmful, potentially resulting in severe diabetic ketoacidosis (DKA). During fasting, ketone body production serves as an alternative and efficient energy source for the brain by utilizing stored fat, promoting mental clarity, and reducing dependence on glucose. The concurrent use of SGLT2 inhibitors during perioperative fasting may further elevate the risk of euglycemic DKA. We describe a case of DKA that occurred during perioperative fasting in a patient receiving empagliflozin, an SGLT2 inhibitor. This case underscores the importance of recognizing the potential risk of DKA in patients with diabetes using SGLT2 inhibitors during perioperative fasting.
7.Diagnosing Complete Response to Preoperative Chemoradiation in Esophageal Cancer Using Dynamic Contrast-Enhanced MRI Response Criteria
Yura AHN ; Jooae CHOE ; Hyun Joo LEE ; Sook Ryun PARK ; Jong-Hoon KIM ; Ho June SONG ; Min-Ju KIM ; Yong-Hee KIM
Korean Journal of Radiology 2025;26(3):269-280
Objective:
To assess the performance of novel qualitative diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to identify the pathologic complete response (pCR) of primary tumors in esophageal cancer after neoadjuvant chemoradiation (nCRT).
Materials and Methods:
Patients who underwent nCRT, subsequent MRI, positron emission tomography/computed tomography (PET/CT), endoscopy, or esophagectomy for esophageal cancer between October 2021 and October 2023 were retrospectively analyzed. The DCE-MRI response of primary tumors was interpreted using five grades by thoracic radiologists as follows: G1 (compatible with CR), G2 (probable CR), G3 (probable partial response [PR]), G4 (compatible with PR), and G5 (stable or progressive disease). The performances of MRI, PET/CT, endoscopy, and their combinations in diagnosing pCR in primary tumors were calculated.
Results:
A total of 52 patients (male:female, 46:6; age, 61.2 ± 8.0 years) were included. Surgical specimens revealed pCR (ypT0) in 34 patients. G1 as the MRI criterion for pCR of primary tumors yielded a positive predictive value (PPV), specificity of 100% (18/18), and low sensitivity (23.5% [8/34]). Combining G1 and G2 as the MRI criteria increased the sensitivity to 73.5% (25/34), with a specificity of 88.9% (16/18), accuracy of 78.8% (41/52), and PPV of 92.6% (25/27). Adding the DCEMRI results (G1-2) significantly improved accuracy for both PET/CT (from 65.4% [34/52] to 80.8% [42/52], P = 0.03) and endoscopy (from 55.8% [29/52] to 76.9% [40/52], P = 0.005), with increase in sensitivity (from 55.9% [19/34] to 82.4% [28/34] for PET/CT-based evaluation [P = 0.008] and from 47.1% [16/34] to 82.4% [28/34] for endoscopy-based evaluation [P = 0.001]).
Conclusion
DCE-MRI-based grading shows high diagnostic performance for identifying pCR in primary tumors, particularly in terms of PPV and specificity, and enhances response evaluation when combined with PET/CT and endoscopy.
8.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
9.Environmental disease monitoring by regional Environmental Health Centers in Korea: a narrative review
Myung-Sook PARK ; Hwan-Cheol KIM ; Woo Jin KIM ; Yun-Chul HONG ; Won-Jun CHOI ; Seock-Yeon HWANG ; Jiho LEE ; Young-Seoub HONG ; Yong-Dae KIM ; Seong-Chul HONG ; Joo Hyun SUNG ; Inchul JEONG ; Kwan LEE ; Won-Ju PARK ; Hyun-Joo BAE ; Seong-Yong YOON ; Cheolmin LEE ; Kyoung Sook JEONG ; Sanghyuk BAE ; Jinhee CHOI ; Ho-Hyun KIM
The Ewha Medical Journal 2025;48(1):e3-
This study explores the development, roles, and key initiatives of the Regional Environmental Health Centers in Korea, detailing their evolution through four distinct phases and their impact on environmental health policy and local governance. It chronicles the establishment and transformation of these centers from their inception in May 2007, through four developmental stages. Originally named Environmental Disease Research Centers, they were subsequently renamed Environmental Health Centers following legislative changes. The analysis includes the expansion in the number of centers, the transfer of responsibilities to local governments, and the launch of significant projects such as the Korean Children’s Environmental Health Study (Ko-CHENS ). During the initial phase (May 2007–February 2009), the 10 centers concentrated on research-driven activities, shifting from a media-centered to a receptor-centered approach. In the second phase, prompted by the enactment of the Environmental Health Act, six additional centers were established, broadening their scope to address national environmental health issues. The third phase introduced Ko-CHENS, a 20-year national cohort project designed to influence environmental health policy by integrating research findings into policy frameworks. The fourth phase marked a decentralization of authority, empowering local governments and redefining the centers' roles to focus on regional environmental health challenges. The Regional Environmental Health Centers have significantly evolved and now play a crucial role in addressing local environmental health issues and supporting local government policies. Their capacity to adapt and respond to region-specific challenges is essential for the effective implementation of environmental health policies, reflecting geographical, socioeconomic, and demographic differences.
10.Diagnosing Complete Response to Preoperative Chemoradiation in Esophageal Cancer Using Dynamic Contrast-Enhanced MRI Response Criteria
Yura AHN ; Jooae CHOE ; Hyun Joo LEE ; Sook Ryun PARK ; Jong-Hoon KIM ; Ho June SONG ; Min-Ju KIM ; Yong-Hee KIM
Korean Journal of Radiology 2025;26(3):269-280
Objective:
To assess the performance of novel qualitative diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to identify the pathologic complete response (pCR) of primary tumors in esophageal cancer after neoadjuvant chemoradiation (nCRT).
Materials and Methods:
Patients who underwent nCRT, subsequent MRI, positron emission tomography/computed tomography (PET/CT), endoscopy, or esophagectomy for esophageal cancer between October 2021 and October 2023 were retrospectively analyzed. The DCE-MRI response of primary tumors was interpreted using five grades by thoracic radiologists as follows: G1 (compatible with CR), G2 (probable CR), G3 (probable partial response [PR]), G4 (compatible with PR), and G5 (stable or progressive disease). The performances of MRI, PET/CT, endoscopy, and their combinations in diagnosing pCR in primary tumors were calculated.
Results:
A total of 52 patients (male:female, 46:6; age, 61.2 ± 8.0 years) were included. Surgical specimens revealed pCR (ypT0) in 34 patients. G1 as the MRI criterion for pCR of primary tumors yielded a positive predictive value (PPV), specificity of 100% (18/18), and low sensitivity (23.5% [8/34]). Combining G1 and G2 as the MRI criteria increased the sensitivity to 73.5% (25/34), with a specificity of 88.9% (16/18), accuracy of 78.8% (41/52), and PPV of 92.6% (25/27). Adding the DCEMRI results (G1-2) significantly improved accuracy for both PET/CT (from 65.4% [34/52] to 80.8% [42/52], P = 0.03) and endoscopy (from 55.8% [29/52] to 76.9% [40/52], P = 0.005), with increase in sensitivity (from 55.9% [19/34] to 82.4% [28/34] for PET/CT-based evaluation [P = 0.008] and from 47.1% [16/34] to 82.4% [28/34] for endoscopy-based evaluation [P = 0.001]).
Conclusion
DCE-MRI-based grading shows high diagnostic performance for identifying pCR in primary tumors, particularly in terms of PPV and specificity, and enhances response evaluation when combined with PET/CT and endoscopy.

Result Analysis
Print
Save
E-mail