1.Delayed Retroperitoneal Hematoma Following Intradiscal Electrothermal Therapy: A Case Report of a Rare Complication
Jun-Yong CHA ; Yun-Young PARK ; Jin-Uk KIM ; Jun-Ho LEE ; Seong-Hwan MUN ; Gun AHN ; Il-Tae JANG
The Nerve 2026;12(1):36-40
Intradiscal electrothermal therapy (IDET) is a minimally invasive procedure used to treat discogenic back pain and offers an alternative to surgical intervention in selected patients. Although it is generally considered safe, rare but significant complications can occur and may be difficult to diagnose because their symptoms overlap with those of other spinal conditions. We describe the case of a 69-year-old woman who presented with severe lower back and left buttock pain that was unresponsive to conservative treatment. Magnetic resonance imaging revealed disc bulging with a high-intensity zone at the L4–5 and L5–S1 levels. IDET was performed at the L4–5 level, resulting in initial pain relief. However, the patient returned 7 days later with recurrent pain. Despite undergoing percutaneous epidural neuroplasty at the left L5–S1 level, a medial branch block, and a piriformis muscle block, her symptoms persisted. Further evaluation with spinal computed tomography revealed a retroperitoneal hematoma near the left psoas muscle. Referred pain from the hematoma mimicked discogenic pain, resulting in delayed diagnosis and unnecessary interventions. The patient remained hemodynamically stable and gradually improved with conservative management alone. This case highlights retroperitoneal hematoma as a rare complication of IDET and emphasizes the importance of accurate and timely diagnosis in patients with persistent or worsening symptoms after spinal procedures. Clinicians should consider non-discogenic sources of pain when treatment outcomes deviate from expected patterns.
2.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
3.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
4.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
5.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
6.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
7.Evidence‑based Korean guidelines for the clinical management of multiple myeloma: addressing 12 key clinical questions
Sung‑Hoon JUNG ; Youngil KOH ; Min Kyoung KIM ; Jin Seok KIM ; Joon Ho MOON ; Chang‑Ki MIN ; Dok Hyun YOON ; Sung‑Soo YOON ; Je‑Jung LEE ; Chae Moon HONG ; Ka‑Won KANG ; Jihyun KWON ; Kyoung Ha KIM ; Dae Sik KIM ; Sung Yong KIM ; Sung‑Hyun KIM ; Yu Ri KIM ; Young Rok DO ; Yeung‑Chul MUN ; Sung‑Soo PARK ; Young Hoon PARK ; Ho Jin SHIN ; Hyeon‑Seok EOM ; Sang Eun YOON ; Sang Mee HWANG ; Won Sik LEE ; Myung‑won LEE ; Jun Ho YI ; Ji Yun LEE ; Ji Hyun LEE ; Ho Sup LEE ; Sung‑Nam LIM ; Jihyang LIM ; Ho‑Young YHIM ; Yoon Hwan CHANG ; Jae‑Cheol JO ; Jinhyun CHO ; Hyungwoo CHO ; Yoon Seok CHOI ; Hee jeong CHO ; Ari AHN ; Jong Han CHOI ; Hyun Jung KIM ; Kihyun KIM
Blood Research 2025;60():9-
Multiple myeloma (MM), a hematological malignancy, is characterized by malignant plasma cell proliferation in the bone marrow. Recent treatment advances have significantly improved patient outcomes associated with MM.In this study, we aimed to develop comprehensive, evidence-based guidelines for the diagnosis, prognosis, and treat‑ ment of MM. We identified 12 key clinical questions essential for MM management, guiding the extensive literature review and meta-analysis of the study. Our guidelines provide evidence-based recommendations by integrating patient preferences with survey data. These recommendations include current and emerging diagnostic tools, thera‑ peutic agents, and treatment strategies. By prioritizing a patient-centered approach and rigorous data analysis, these guidelines were developed to enhance MM management, both in Korea and globally.
8.Introduction to the forensic research via omics markers in environmental health vulnerable areas (FROM) study
Jung-Yeon KWON ; Woo Jin KIM ; Yong Min CHO ; Byoung-gwon KIM ; Seungho LEE ; Jee Hyun RHO ; Sang-Yong EOM ; Dahee HAN ; Kyung-Hwa CHOI ; Jang-Hee LEE ; Jeeyoung KIM ; Sungho WON ; Hee-Gyoo KANG ; Sora MUN ; Hyun Ju YOO ; Jung-Woong KIM ; Kwan LEE ; Won-Ju PARK ; Seongchul HONG ; Young-Seoub HONG
Epidemiology and Health 2024;46(1):e2024062-
This research group (forensic research via omics markers in environmental health vulnerable areas: FROM) aimed to develop biomarkers for exposure to environmental hazards and diseases, assess environmental diseases, and apply and verify these biomarkers in environmentally vulnerable areas. Environmentally vulnerable areas—including refineries, abandoned metal mines, coal-fired power plants, waste incinerators, cement factories, and areas with high exposure to particulate matter—along with control areas, were selected for epidemiological investigations. A total of 1,157 adults, who had resided in these areas for over 10 years, were recruited between June 2021 and September 2023. Personal characteristics of the study participants were gathered through a survey. Biological samples, specifically blood and urine, were collected during the field investigations, separated under refrigerated conditions, and then transported to the laboratory for biomarker analysis. Analyses of heavy metals, environmental hazards, and adducts were conducted on these blood and urine samples. Additionally, omics analyses of epigenomes, proteomes, and metabolomes were performed using the blood samples. The biomarkers identified in this study will be utilized to assess the risk of environmental disease occurrence and to evaluate the impact on the health of residents in environmentally vulnerable areas, following the validation of diagnostic accuracy for these diseases.
9.Treatment Outcomes of Olfactory Neuroblastoma: A Multicenter Study by the Korean Sinonasal Tumor and Skull Base Surgery Study Group
Sang Duk HONG ; Song I PARK ; Ji Heui KIM ; Sung Jae HEO ; Sung-Woo CHO ; Tae-Bin WON ; Hyun-Jin CHO ; Dong Hoon LEE ; Sue Jean MUN ; Soo Kyoung PARK ; Yong-Wan KIM ; Dong-Young KIM
Clinical and Experimental Otorhinolaryngology 2024;17(2):137-146
Objectives:
. Due to the rarity of olfactory neuroblastoma (ONB), there is ongoing debate about optimal treatment strategies, especially for early-stage or locally advanced cases. Therefore, our study aimed to explore experiences from multiple centers to identify factors that influence the oncological outcomes of ONB.
Methods:
. We retrospectively analyzed 195 ONB patients treated at nine tertiary hospitals in South Korea between December 1992 and December 2019. Kaplan-Meier survival analysis was used to evaluate oncological outcomes, and a Cox proportional hazards regression model was employed to analyze prognostic factors for survival outcomes. Furthermore, we conducted 1:1 nearest-neighbor matching to investigate differences in clinical outcomes according to the use of neoadjuvant chemotherapy.
Results:
. In our cohort, the 5-year overall survival (OS) rate was 78.6%, and the 5-year disease-free survival (DFS) rate was 62.4%. The Cox proportional hazards model revealed that the modified Kadish (mKadish) stage and Dulguerov T status were significantly associated with DFS, while the mKadish stage and Hyams grade were identified as prognostic factors for OS. The subgroup analyses indicated a trend toward improved 5-year DFS with dural resection in mKadish A and B cases, even though the result was statistically insignificant. Induction chemotherapy did not provide a survival benefit in this study after matching for the mKadish stage and nodal status.
Conclusion
. Clinical staging and pathologic grading are important prognostic factors in ONB. Dural resection in mKadish A and B did not show a significant survival benefit. Similarly, induction chemotherapy also did not show a survival benefit, even after stage matching.
10.Subjective Visual Floaters after Intravitreal Injection and Effect of the Inverse Tapping Technique
Junho MUN ; Yong-Kyu KIM ; Sung Pyo PARK ; Kyoung Lae KIM
Journal of the Korean Ophthalmological Society 2024;65(2):125-131
Purpose:
To analyze the incidence of vitreous floaters after intravitreal antivascular endothelial growth factor injection and the effectiveness of the inverse tapping technique, which involves tapping the syringe with the needle downwards to prevent the entry of air bubbles during injection.
Methods:
The study enrolled patients undergoing their first intravitreal injection for exudative age-related macular degeneration or diabetic macular edema. The patients were divided into two groups: those who received an injection after inverse tapping (IT group) and controls who received the injection without tapping. Patients who consented to the study were randomly assigned to the IT group and the control group through block randomization. One week after injection, a questionnaire was used to assess the presence of vitreous floaters; those who reported them were examined via optical coherence tomography and wide fundus photography.
Results:
Of the 39 patients in the IT group, two (5.1%) reported floaters 1 week after injection. By contrast, eight (20.5%) of the 39 controls reported them, with a significant difference (p = 0.042). Patients with floaters were significantly younger. Posterior vitreous detachment, as evaluated by pre-injection optical coherence tomography, was observed in 10.0% of those with floaters and 76.5% of those without them.
Conclusions
The occurrence of vitreous floaters after intravitreal injection is related to age and the presence of posterior vitreous detachment. The use of the inverse tapping technique may help reduce these after intravitreal injection.

Result Analysis