1.Process of developing basic veterinary clinical performance guidelines based on common clinical manifestations in Korea
Kichang LEE ; Heungshik S. LEE ; Yong Jun KIM ; Incheol PARK ; Kangmoon SEO ; Seong Mok JEONG ; Kyu-Woan CHO ; Jin Young CHUNG ; Dongbin LEE ; Chun-Sik BAE ; Sung-Lim LEE ; Ki-Jeong NA ; Sooyoung CHOI ; Inseong JEONG ; Pan Dong RYU ; Sang-Soep NAHM
Journal of Veterinary Science 2026;27(2):e24-
Objective:
To explain process of developing basic veterinary clinical performance guidelines, based on frequently observable clinical manifestations, thereby supporting competencybased veterinary education in Korea.
Methods:
A structured review of learning outcomes established by Korean Association of Veterinary Medical Colleges (KAVMC) was conducted by a planning committee including veterinary educators, practitioners, and advisory members. Owner-oriented descriptions were used to frame each performance task, and each was mapped to corresponding learning outcomes. These tasks were aligned with learning outcomes recommended by the KAVMC to support the development of communication, clinical reasoning, and performance-related competencies among veterinary students, thereby enhancing day-one clinical readiness.
Results:
In total, 63 clinical manifestations for a guidebook format that can be used for clinical education were identified and categorized by organ systems that are described in language understandable to animal owners.
Conclusions
and Relevance: The basic veterinary clinical performance guidelines based on common clinical manifestations would serve as a vital component in veterinary education to reinforce core graduation competencies.
2.Corrigendum: Correction of Funding in the Article “List of occupational diseases among farmers in Korea: a literature review”
Hansoo SONG ; Seok-Ju YOO ; Won-Ju PARK ; Seunghyeon CHO ; Ki Soo PARK ; Joo Hyun SUNG ; Sang Jin PARK ; Seong-yong YOON ; Kyeongsoo KIM ; Dong-phil CHOI ; Hye-min KIM ; Bounggyun JU ; Kanwoo YOUN
Annals of Occupational and Environmental Medicine 2025;37(1):e16-
3.List of occupational diseases among farmers in Korea: a literature review
Hansoo SONG ; Seok-Ju YOO ; Won-Ju PARK ; Seunghyeon CHO ; Ki Soo PARK ; Joo Hyun SUNG ; Sang Jin PARK ; Seong-yong YOON ; Kyeongsoo KIM ; Dong-phil CHOI ; Hye-min KIM ; Bounggyun JU ; Kanwoo YOUN
Annals of Occupational and Environmental Medicine 2025;37(1):e2-
A comprehensive list of occupational diseases among farmers is crucial for both compensation and prevention efforts. In Korea, most farmers are self-employed, and some occupational diseases are compensated through farmer safety insurance. However, it is not harmonized with industrial accident compensation insurance and does not adequately reflect the true burden of occupational diseases among farmers. To address this gap, the authors compiled a list of occupational diseases tailored to Korean farmers by reviewing the International Labor Organization’s list of occupational diseases, the Korean Industrial Accident Compensation Insurance List, the occupational disease lists of other countries, and relevant literature on farmers’ work-related diseases.
4.Reinjection in Patients with Intraocular Inflammation Development after Intravitreal Brolucizumab Injection
Myung Ae KIM ; Soon Il CHOI ; Jong Min KIM ; Hyun Sub OH ; Yong Sung YOU ; Won Ki LEE ; Soon Hyun KIM ; Oh Woong KWON ; Ju Young KIM
Korean Journal of Ophthalmology 2025;39(3):213-221
Purpose:
To investigate the outcomes of brolucizumab reinjection after intraocular inflammation (IOI) development.
Methods:
This retrospective study analyzed patients with brolucizumab injections from April 2021 to January 2024. Patients who developed IOI after brolucizumab were included and categorized into subgroups depending on reinjection, discontinuation, and further IOI development.
Results:
A total of 472 eyes of 432 patients received brolucizumab injections. Thirty-eight cases developed IOI at least once, and 25 continued brolucizumab. Sixteen cases had no more IOI events, and nine experienced a second or more IOI events. Among the nine cases, three maintained brolucizumab injections despite IOI recurrence. The incidence of IOI was 8.1% based on the number of eyes (38 of 472 eyes) and 2.0% based on the number of brolucizumab injections (50 of 2,468 injections). The incidence of occlusive retinal vasculitis was 0.2% (1 of 472 eyes). The recurrence rate was 23.7% (9 of 38 eyes). The average number of injections between the first brolucizumab injection and the injection date on which IOI first developed was 2.15 times in the no-reinjection group, 3.44 times in the no-IOI-recurrence group, and 2.0 times in the second-IOI-episode group. Time to IOI occurrence in cases with first IOI episode was 18.60 ± 16.73 days, with 15 cases developing IOI within 1 week.
Conclusions
This study elucidates the real-world incidence of brolucizumab associated IOIs, with a description of information related to reinjections after the IOI episodes. A comprehensive understanding of brolucizumab reinjection is essential for its optimal utilization.
5.How to Achieve Diversity, Equity, and Inclusion in The Korean Society of Gastroenterology?
Nayoung KIM ; Kwangwoo NAM ; Ki-Nam SHIM ; Hyo Jung KIM ; Su Youn NAM ; Sae Kyung JOO ; Seun Ja PARK ; Yonghoon CHOI ; Yoon Ju JUNG ; Yong Sung KIM ; Ja Kyung KIM ; Seon Mee PARK
The Korean Journal of Gastroenterology 2025;85(1):22-30
With the increasing emphasis on diversity, equity, and inclusion (DEI) in organizations and institutions, academic societies in gastroenterology and hepatology are beginning to take actionable steps toward achieving DEI. The successful implementation of DEI initiatives leads to excellence in the field, improved patient outcomes, particularly in areas where health disparities are prevalent, and advances in the gastrointestinal discipline. Such implementation also results in a workforce that better reflects the growing diversity of the population. This review defines DEI and introduces the DEI policies and strategies adopted by the academic societies of gastroenterology in other countries. This paper proposes strategies to integrate DEI better into the Korean Society of Gastroenterology, emphasizing the importance of embedding DEI into the culture and strategic framework. The key strategies include establishing a DEI committee, setting clear targets, and conducting formal assessments to measure DEI progress. This study focused on enhancing workforce diversity, particularly among women and young doctors, and advocates for the need to support their academic development through male allyship and the promotion of equitable and inclusive academic cultures.
6.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
8.Immunologic Response and Effects of COVID-19Vaccines in Patients with Antineutrophil Cytoplasmic Antibody-Associated Vasculitis
Ki Hyun LEE ; Hyunsue DO ; Jun Yong CHOI ; Yong-Beom PARK ; Sinyoung KIM ; Sang-Won LEE ; Su Jin JEONG
Yonsei Medical Journal 2025;66(5):259-268
Purpose:
The immunological response and adverse effects of antineutrophil cytoplasmic antibody-associated vasculitis (AAV) in patients receiving coronavirus disease-2019 (COVID-19) vaccines remain unclear. We aimed to evaluate the effects of these vaccines on AAV disease activity.
Materials and Methods:
We reviewed the medical records of 52 patients with AAV who had received at least second doses of the COVID-19 vaccine and evaluated their immunogenicity by measuring the anti-spike (S) antibody (Ab) titer levels using the Roche Elecsys® immunoassay. Responses to the Birmingham Vasculitis Activity Score (BVAS) tool and 36-Item Short Form Survey before and after vaccination were obtained to assess AAV disease activity. Vaccine reactivity was measured using a standardized questionnaire.
Results:
We enrolled 52 patients with AAV. No differences were found between those who received second and third doses of vaccination in terms of AAV type, disease activity, vaccine type, or the use of immunosuppressive agents, including steroids. The median anti-S Ab titer was 3967.0 after third doses compared to 419.0 after second doses (p=0.001). Except for mycophenolate mofetil (MMF), when immunosuppressants were administered in conjunction with steroids, the Ab titer was higher after the third vaccination than that after the second dose. The BVAS remained unchanged before and after second and third doses. No life-threatening adverse events were reported.
Conclusion
Although COVID-19 vaccine may not produce sufficient antibodies in patients taking MMF, the vaccine did not exacerbate disease activity or cause severe side effects. Therefore, COVID-19 vaccines should be considered in patients with AAV.
9.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail