1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
3.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
4.Characteristics and influencing factors of occupational injuries among workers in a cable manufacturing enterprise
Ting XU ; Juan QIAN ; Yishuo GU ; Daozheng DING ; Jianjian QIAO ; Yong QIAN ; Xiaojun ZHU ; Jingguang FAN
Journal of Environmental and Occupational Medicine 2025;42(2):140-144
Background Workers in the cable manufacturing industry are exposed to high-speed machinery and equipment for a long time, coupled with heavy workload, which poses significant risks to their physical health. However, the issue of occupational injuries in this industry has not received enough attention yet. Objective To understand the incidence of occupational injury of workers in cable manufacturing industry and to analyze the influencing factors. Method A basic information questionnaire and an occupational injury questionnaire were developed to investigate the occupational injuries of 1 343 workers in a cable manufacturing enterprise in the past year, and a total of 1 225 valid questionnaires were recovered, with an effective rate of 91.2%. Descriptive statistics were used to characterize the causes, injury locations, injury types, and other characteristics of employees’ occupational injuries. Chi-square test was used to analyze the occupational injury status of groups with different demographic characteristics, occupational characteristics, lifestyles, and interpersonal relationships. Logistic regression was used to analyze the influencing factors of occupational injuries. Result The incidence of occupational injuries among workers in a cable manufacturing enterprise in the past year was 8.6%, which mainly happened in male workers (80.0%) and occurred from May to July in summer (45.7%). The main causes were mechanical injuries (32.4%) and object blows (27.6%). The main sources of damage were machinery and equipment (36.2%) as well as raw materials and products (15.2%). The main injuries were located in upper limbs (53.3%) and lower limbs (22.9%). The main types of injuries were fractures (33.3%) and abrasions/contusions/puncture wounds (19.0%). The results of univariate analysis showed that there were statistically significant variations in the incidence of occupational injuries by gender, overtime, pre-job training, years of service in current position, alcohol consumption, physical exercise per week, and co-worker relationship (P<0.05). The logistic regression model showed that workers who exercised less than twice a week, did not participate in pre-job training, worked overtime, and had fair/poor/very poor colleague relationship had a higher risk of occupational injury, while women had a lower risk of occupational injury. Conclusion The distribution of occupational injury population is mainly male, and the time distribution is mainly from May to July. Gender, physical exercise, pre-job training, overtime, and colleague relationship are the influencing factors of occupational injuries. We should strengthen pre-job training, arrange work hours reasonably, and create a good working atmosphere to reduce the occurrence of occupational injuries.
5.Relationship between occupational stress and occupational injury of workers in a cable manufacturing enterprise by decision tree model
Ting XU ; Juan QIAN ; Yishuo GU ; Daozheng DING ; Jianjian QIAO ; Yong QIAN ; Xiaojun ZHU ; Jingguang FAN
Journal of Environmental and Occupational Medicine 2025;42(2):145-150
Background Social psychological factors have emerged as a key area of research in occupational injury prevention. Occupational stress, a significant component of social psychology, has garnered widespread attention due to its potential impact on occupational injury. Objective To analyze the factors influencing occupational stress among cable manufacturing workers and explore the relationship between occupational stress and occupational injury, and to provide scientific evidence for reducing occupational stress and injury. Methods A questionnaire on basic demographics, occupational injury, and occupational stress (Effort-Reward Imbalance, ERI) was used to investigate
6.Controllability Analysis of Structural Brain Networks in Young Smokers
Jing-Jing DING ; Fang DONG ; Hong-De WANG ; Kai YUAN ; Yong-Xin CHENG ; Juan WANG ; Yu-Xin MA ; Ting XUE ; Da-Hua YU
Progress in Biochemistry and Biophysics 2025;52(1):182-193
ObjectiveThe controllability changes of structural brain network were explored based on the control and brain network theory in young smokers, this may reveal that the controllability indicators can serve as a powerful factor to predict the sleep status in young smokers. MethodsFifty young smokers and 51 healthy controls from Inner Mongolia University of Science and Technology were enrolled. Diffusion tensor imaging (DTI) was used to construct structural brain network based on fractional anisotropy (FA) weight matrix. According to the control and brain network theory, the average controllability and the modal controllability were calculated. Two-sample t-test was used to compare the differences between the groups and Pearson correlation analysis to examine the correlation between significant average controllability and modal controllability with Fagerström Test of Nicotine Dependence (FTND) in young smokers. The nodes with the controllability score in the top 10% were selected as the super-controllers. Finally, we used BP neural network to predict the Pittsburgh Sleep Quality Index (PSQI) in young smokers. ResultsThe average controllability of dorsolateral superior frontal gyrus, supplementary motor area, lenticular nucleus putamen, and lenticular nucleus pallidum, and the modal controllability of orbital inferior frontal gyrus, supplementary motor area, gyrus rectus, and posterior cingulate gyrus in the young smokers’ group, were all significantly different from those of the healthy controls group (P<0.05). The average controllability of the right supplementary motor area (SMA.R) in the young smokers group was positively correlated with FTND (r=0.393 0, P=0.004 8), while modal controllability was negatively correlated with FTND (r=-0.330 1, P=0.019 2). ConclusionThe controllability of structural brain network in young smokers is abnormal. which may serve as an indicator to predict sleep condition. It may provide the imaging evidence for evaluating the cognitive function impairment in young smokers.
7.Effect of central positioning techniques for anterior capsulotomy in femtosecond laser-assisted cataract surgery on intraocular placement and visual quality
Shuaishuai LIU ; Wei ZHOU ; Xiaochen DING ; Shuang ZHANG ; Qiangqiang CHI ; Yong LIU
International Eye Science 2025;25(4):523-529
AIM: To examine how three distinct central positioning techniques for anterior capsulotomy-pupil center, limbus center, and lens apex-affect intraocular lens(IOL)placement and visual quality following femtosecond laser-assisted cataract surgery(FLACS).METHODS: A total of 36 patients(72 eyes)with age-related cataracts who underwent FLACS and ZCB00 aspherical IOL implantation at Aier Eye Hospital Medical Center, Anhui Medical University between January and December 2023 were included in this prospective study. Patients were divided into three groups based on the central positioning mode for anterior capsulotomy: pupil center, limbus center, and lens apex center groups. IOL alignment and displacement were evaluated using the Casia2 device, and the postoperative visual quality was assessed.RESULTS: At 1 d postoperatively, the IOL tilt for the pupil, limbus, and apex groups were 3.96°±1.51°, 4.63°±1.87°, and 3.90°±2.24°, respectively(F=1.07, P=0.35); IOL decentration values were 0.21±0.10 mm, 0.23±0.16 mm, and 0.21±0.12 mm, respectively(F=0.14, P=0.87); total higher-order aberrations were 0.32±0.40 μm, 0.56±0.61 μm, and 0.53±0.60 μm, respectively(F=1.38, P=0.26); and coma aberrations values were 0.13±0.10 μm, 0.16±0.15 μm, and 0.14±0.15 μm, respectively(F=0.3, P=0.74). All results obtained postoperative day 1 did not differ significantly. At 3 mo postoperatively, IOL tilt values were 5.42°±2.00°, 3.96°±1.44°, and 3.20°±1.19°, respectively(F=12.40, P<0.001); IOL decentration values were 0.33±0.07 mm, 0.23±0.11 mm, and 0.21±0.11 mm, respectively(F=4.99, P=0.008); total higher-order aberrations were 0.67±0.29 μm, 0.44±0.37 μm, and 0.42±0.19 μm, respectively(F=5.50, P=0.006); and coma aberrations values were 0.21±0.12 μm, 0.19±0.12 μm, and 0.12±0.11 μm, respectively(F=3.87, P=0.03). All results obtained 3 mo postoperatively were statistically significant.CONCLUSION: Using the lens apex as the central positioning mode for anterior capsulotomy in FLACS improves postoperative IOL stability and reduces postoperative IOL tilt and decentration. If the lens apex cannot be determined intraoperatively, the limbus center-positioning mode is recommended.
8.Five new triterpenoid saponins from the kernels of Momordica cochinchinensis
Ru DING ; Jia-qi WANG ; Yi-yang LUO ; Yong-long HAN ; Xiao-bo LI ; Meng-yue WANG
Acta Pharmaceutica Sinica 2025;60(2):442-448
Five saponins were isolated from the kernels of
9.Antimicrobial resistance surveillance in the bacterial strains isolated from pediatric intensive care units in China:results from 2020 to 2022
Jing LIU ; Huiyuan YAN ; Gangfeng YAN ; Guoping LU ; Pan FU ; Chuanqing WANG ; Danqun JIN ; Wenjia TONG ; Chenyu ZHANG ; Jianli CHEN ; Yi LIN ; Jia LEI ; Yibing CHENG ; Qunqun ZHANG ; Kaijie GAO ; Yuanyuan CHEN ; Shufang XIAO ; Juan HE ; Li JIANG ; Huimin XU ; Yuxia LI ; Hanghai DING ; Hehe CHEN ; Yao ZHENG ; Qunying CHEN ; Ying WANG ; Hong REN ; Chenmei ZHANG ; Zhenjie CHEN ; Mingming ZHOU ; Yucai ZHANG ; Yiping ZHOU ; Zhenjiang BAI ; Saihu HUANG ; Lili HUANG ; Weiguo YANG ; Weike MA ; Qing MENG ; Pengwei ZHU ; Yong LI ; Yan XU ; Yi WANG ; Yanqiang DU ; Huijun CAI ; Bizhen ZHU ; Huixuan SHI ; Shaoxian HONG ; Yukun HUANG ; Meilian HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(3):303-311
Objective This study aimed to investigate the antimicrobial resistance profiles of bacterial strains isolated from pediatric intensive care units(PICU)in China for better antimicrobial therapy.Methods Clinical isolates were collected from 17 institutions,including tertiary care children's hospitals and pediatric department of tertiary general hospitals in China from January 1,2020 to December 31,2022.Antimicrobial susceptibility testing was carried out according to a unified protocol using Kirby-Bauer method or automated systems.Results were interpreted according to the breakpoints released by the Clinical and Laboratory Standards Institute(CLSI)in 2020.Results A total of 10 688 isolates were collected,including gram-positive organisms(39.2%)and gram-negative organisms(60.8%).The top three organisms were S.aureus(13.6%,1 453/10 688),A.baumannii(10.0%,1 067/10 688),and coagulase-negative Staphylococcus(9.9%,1 058/10 688).Multi-drug resistant organisms(MDROs)were very common in children.The prevalence of methicillin-resistant Staphylococcus aureus(MRSA),carbapenem-resistant Enterobacterales(CRE),carbapenem-resistant E.coli,carbapenem-resistant K.pneumoniae(CRKP),carbapenem-resistant A.baumannii(CRAB),and carbapenem-resistant P.aeruginosa(CRPA)was 41.1%,19.4%,8.8%,30.9%,67.4%,and 28.8%,respectively.Overall,more than 50%of Enterobacteriales isolates were resistant to cephalosporins,while nearly 25%of Enterobacteriales isolates were resistant to carbapenems.MDROs were highly resistant to commonly used antibiotics.More than 80%of CRE and CRAB strains were resistant to all beta-lactam antibiotics.CRE and CRAB showed low resistance rates to tigecycline and polymyxin.CRPA showed lower resistance rates to piperacillin,beta-lactamase inhibitor combinations than the resistance rates to third and fourth generation cephalosporins.All of the Staphylococcus and Enterococcus isolates were susceptible to vancomycin and tigecycline.None of PRSP strains isolated from meningitis and nonmeningitis samples were resistant to rifampicin,vancomycin,or linezolid.The prevalence of β-lactamase-negative ampicillin-resistant(BLNAR)strains was 43.3%in Haemophilus influenzae.Conclusions MDROs were prevalent in PICU.It is necessary to establish an effective multidisciplinary team(MDT)to control the antimicrobial resistance.
10.Dosimetric differences between 6 MV flatten-filter free MC and CCC algorithms for the same machine model
Yong SANG ; Jian'an WU ; Man ZHAO ; Zhen DING ; Jiajun CAI
Chinese Journal of Medical Physics 2025;42(5):571-576
Objective To analyze the dosimetric differences between Monaco Monte Carlo(MC)algorithm and Pinnacle collapse cone convolution(CCC)algorithm for the same machine model using the 6 MV flatten-filter free(FFF)mode,thus providing a reference for the clinical application of these two treatment planning systems.Methods According to the MPPG5 and TRS430 reports,the acceptance and commissioning of Monaco MC algorithm model and Pinnacle CCC algorithm model in Department of Radiation Oncology,Shenzhen Hospital,Cancer Hospital of Chinese Academy of Medical Sciences were performed.A retrospectively analysis was conducted on 30 cases,including 10 cases of nasopharyngeal cancer,6 cases of lung cancer,4 cases of esophageal cancer,and 10 cases of cervical cancer.For each case,a 6 MV FFF plan was designed in Pinnacle using CCC algorithm.A 2.5 mm dose grid was selected for plan optimization and dose calculation.The plan was then exported to Monaco,where dose to medium was calculated using MC algorithm and a 2.5 mm dose grid with a 1%uncertainty for each control point.Both calculations in Pinnacle and Monaco took into account the impact of the treatment couch and immobilization devices on dose attenuation.The dose differences to the target volumes and major organs at risk between Pinnacle and Monaco for 3 different body parts including the head,chest and abdomen were compared.Results(1)For nasopharyngeal cancer,compared with Pinnacle CCC algorithm,Monaco MC algorithm lowered the Vpd of PTVp,PTVn,PTVrpn,PTV1 and PTV2 by 9.98%,2.64%,15.0%,1.93%and 8.01%,elevated the Dmax of PTVp,PTVn and PTVrpn by 2.98%,5.62%and 2.39%,increased the Dmean of PTVn and PTV1 by 1.87%and 0.72%,respectively;and the Dmax of the brainstem,the Dmax of the optic chiasm,and the Dmean of the right parotid gland were 3.83%lower,7.03%higher and 1.32%higher in Monaco MC algorithm as compared with Pinnacle CCC algorithm,respectively.(2)For lung cancer and esophageal cancer,Monaco MC algorithm showed increases of 2.37%,4.18%,15.30%,6.36%and 1.04%in the Dmax of PGTV,the V20,V5 and Dmean of lungs,and the V30 of heart as compared with Pinnacle CCC algorithm,respectively.(3)For cervical cancer,the Vpd of PTV_LR,Dmax of PTV_LR,the V40 of the rectum,the Dmax of the small intestine,and the Dmean of humeral head were 7.70%lower,3.70%higher,4.31%lower,3.05%higher and 2.07%higher in Monaco MC algorithm than in Pinnacle CCC algorithm,respectively.These differences were statistically significant(P<0.05).Conclusion For the above 3 treatment sites,significant differences are found in dose calculations for target areas and organs at risk between Monaco MC algorithm and Pinnacle CCC algorithm for the same treatment plan.Attention should be paid to the differences in dose algorithms for different treatment planning systems in clinical applications,which may have impacts on patient survival rates and organ toxicity.

Result Analysis
Print
Save
E-mail