1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
3.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
4.Percutaneous coronary intervention vs . medical therapy in patients on dialysis with coronary artery disease in China.
Enmin XIE ; Yaxin WU ; Zixiang YE ; Yong HE ; Hesong ZENG ; Jianfang LUO ; Mulei CHEN ; Wenyue PANG ; Yanmin XU ; Chuanyu GAO ; Xiaogang GUO ; Lin CAI ; Qingwei JI ; Yining YANG ; Di WU ; Yiqiang YUAN ; Jing WAN ; Yuliang MA ; Jun ZHANG ; Zhimin DU ; Qing YANG ; Jinsong CHENG ; Chunhua DING ; Xiang MA ; Chunlin YIN ; Zeyuan FAN ; Qiang TANG ; Yue LI ; Lihua SUN ; Chengzhi LU ; Jufang CHI ; Zhuhua YAO ; Yanxiang GAO ; Changan YU ; Jingyi REN ; Jingang ZHENG
Chinese Medical Journal 2025;138(3):301-310
BACKGROUND:
The available evidence regarding the benefits of percutaneous coronary intervention (PCI) on patients receiving dialysis with coronary artery disease (CAD) is limited and inconsistent. This study aimed to evaluate the association between PCI and clinical outcomes as compared with medical therapy alone in patients undergoing dialysis with CAD in China.
METHODS:
This multicenter, retrospective study was conducted in 30 tertiary medical centers across 12 provinces in China from January 2015 to June 2021 to include patients on dialysis with CAD. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, and non-fatal stroke. Secondary outcomes included all-cause death, the individual components of MACE, and Bleeding Academic Research Consortium criteria types 2, 3, or 5 bleeding. Multivariable Cox proportional hazard models were used to assess the association between PCI and outcomes. Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were performed to account for potential between-group differences.
RESULTS:
Of the 1146 patients on dialysis with significant CAD, 821 (71.6%) underwent PCI. After a median follow-up of 23.0 months, PCI was associated with a 43.0% significantly lower risk for MACE (33.9% [ n = 278] vs . 43.7% [ n = 142]; adjusted hazards ratio 0.57, 95% confidence interval 0.45-0.71), along with a slightly increased risk for bleeding outcomes that did not reach statistical significance (11.1% vs . 8.3%; adjusted hazards ratio 1.31, 95% confidence interval, 0.82-2.11). Furthermore, PCI was associated with a significant reduction in all-cause and cardiovascular mortalities. Subgroup analysis did not modify the association of PCI with patient outcomes. These primary findings were consistent across IPTW, PSM, and competing risk analyses.
CONCLUSION
This study indicated that PCI in patients on dialysis with CAD was significantly associated with lower MACE and mortality when comparing with those with medical therapy alone, albeit with a slightly increased risk for bleeding events that did not reach statistical significance.
Humans
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Artery Disease/drug therapy*
;
Retrospective Studies
;
Renal Dialysis/methods*
;
Middle Aged
;
Aged
;
China
;
Proportional Hazards Models
;
Treatment Outcome
5.Efficacy and safety of secukinumab in Chinese patients with psoriasis: Update of six-year real-world data and a meta-analysis.
He HUANG ; Yaohua ZHANG ; Caihong ZHU ; Zhengwei ZHU ; Yujun SHENG ; Min LI ; Huayang TANG ; Jinping GAO ; Dawei DUAN ; Hequn HUANG ; Weiran LI ; Tingting ZHU ; Yantao DING ; Wenjun WANG ; Yang LI ; Xianfa TANG ; Liangdan SUN ; Yanhua LIANG ; Xuejun ZHANG ; Yong CUI ; Bo ZHANG
Chinese Medical Journal 2025;138(23):3198-3200
6.Current status and suggestions on regulation of traditional Chinese medicine raw materials and preparations under regulatory system of drugs.
Li-Ping QU ; Yong-Dan XU ; Wei-Jing HE ; Ding-Kun ZHANG ; Nan YANG ; Min-Xian SONG ; Zhi-Qiang MIN ; Ting-Mo ZHANG
China Journal of Chinese Materia Medica 2025;50(3):824-832
At present, the cause of traditional Chinese medicine(TCM) in China has entered a new period of high-quality development. How to strengthen the foundation for the TCM industry from the source is an important issue that deserves the attention of the authorities, industry, and academia. This study systematically analyzed the regulatory system of TCM raw materials and preparations. The study took the TCM industry chain and the product life cycle as a clue and focused on the dimensions of TCM resource protection and plant cultivation(farming), production and quality supervision of TCM raw materials and preparations, and their market access and distribution. It analyzed the current situation of the regulation of TCM raw materials and preparations under the regulatory system of drugs, discussed the main problems, and put forward corresponding suggestions. The results can provide an important reference value for the subsequent improvement of the regulatory system of drugs and the construction of a prominent regulatory system of drugs in accordance with TCM characteristics.
Drugs, Chinese Herbal/economics*
;
Medicine, Chinese Traditional/standards*
;
China
;
Quality Control
;
Humans
;
Plants, Medicinal/chemistry*
7.A new triterpenoid from Elephantopus scaber.
Zu-Xiao DING ; Hong-Xi XIE ; Lin CHEN ; Jun-Jie HAO ; Yan-Qiu LUO ; Zhi-Yong JIANG ; Shi-Kui XU
China Journal of Chinese Materia Medica 2025;50(5):1224-1230
The chemical constituents of the petroleum ether extract derived from the 90% ethanol extract of Elephantopus scaber were investigated. By silica gel column chromatography, C_(18), MCI column chromatography and semi-preparative high performance liquid chromatography, ten compounds were isolated. Their structures were identified as 3β-hydroxy-6β,7β-epoxytaraxeran-14-ene(1), 3β-hydroxyolean-12-en-28-oic acid(2), D-friedoolean-14-ene-3β,7α-diol(3), 3β-hydroxy-11α-methoxyolean-12-ene(4), 3β-hydroxyolean-11,13(18)-diene(5), 11α-hydroxy-β-amyrin(6), betulinic acid(7), 3β-hydroxy-30-norlupan-20-one(8), 6-acetonylchelerythrine(9), and 4',5'-dehydrodiodictyonema A(10) by analysis of the 1D NMR, 2D NMR, MS, and IR spectral data. Among them, compound 1 was a new triterpene and other compounds except compounds 2 and 7 were isolated from this plant for the first time.
Triterpenes/isolation & purification*
;
Drugs, Chinese Herbal/isolation & purification*
;
Molecular Structure
;
Asteraceae/chemistry*
;
Chromatography, High Pressure Liquid
;
Magnetic Resonance Spectroscopy
8.Advances in target-guided discovery technologies for active components in traditional Chinese medicine.
Meng DING ; Wang-Xiao TAN ; Xiao ZHANG ; Peng-Fei TU ; Yong JIANG
China Journal of Chinese Materia Medica 2025;50(13):3645-3656
Traditional Chinese medicine(TCM), with diverse structural types of active components and remarkable clinical efficacy, holds a significant position in the pharmacological research. As the key substances, active components of TCM are of great importance in revealing the material basis of TCM efficacy and mechanism of action. However, the conventional approaches of discovering active components in TCM are characterized by tedious procedures, lengthy cycles, and unclear mechanisms, which struggle to meet the current demands for drug development. In recent years, major breakthroughs have been made in target discovery technologies, and new drug targets are constantly being discovered, which has facilitated the development of target-driven approaches. The target-guided active component discovery strategy provides a new paradigm for discovering active components in TCM. This article systematically summarizes two mainstream target-based technologies-virtual screening and ligand fishing-for TCM active component discovery. By analyzing relevant application cases, this article evaluates the strengths and limitations of each technology. The review aims to provide frameworks for expediting bioactive component discovery in complex systems like TCM, so as to accelerate the development of innovative drugs based on the active components of TCM and promote the modernization and internationalization of TCM.
Drugs, Chinese Herbal/pharmacology*
;
Humans
;
Medicine, Chinese Traditional
;
Drug Discovery/methods*
;
Animals
9.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*

Result Analysis
Print
Save
E-mail