1.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Novel carbazole attenuates vascular remodeling through STAT3/CIAPIN1 signaling in vascular smooth muscle cells.
Joo-Hui HAN ; Jong-Beom HEO ; Hyung-Won LEE ; Min-Ho PARK ; Jangmi CHOI ; Eun Joo YUN ; Seongpyo LEE ; Gyu Yong SONG ; Chang-Seon MYUNG
Acta Pharmaceutica Sinica B 2025;15(3):1463-1479
This study investigated the molecular mechanism of phenotypic switching of vascular smooth muscle cells (VSMCs), which play a crucial role in vascular remodeling using 9H-Carbazol-3-yl 4-aminobenzoate (CAB). CAB significantly attenuated platelet-derived growth factor (PDGF)-induced VSMC proliferation and migration. CAB suppressed PDGF-induced STAT3 activation by directly binding to the SH2 domain of STAT3. Downregulation of STAT3 phosphorylation by CAB attenuated CIAPIN1/JAK2/STAT3 axis through a decrease in CIAPIN1 transcription. Furthermore, abrogated CIAPIN1 decreased KLF4-mediated VSMC dedifferentiation and increased CDKN1B-induced cell cycle arrest and MMP9 suppression. CAB inhibited intimal hyperplasia in injury-induced neointima animal models by inhibition of the CIAPIN1/JAK2/STAT3 axis. However, CIAPIN1 overexpression attenuated CAB-mediated suppression of VSMC proliferation, migration, phenotypic switching, and intimal hyperplasia. Our study clarified the molecular mechanism underlying STAT3 inhibition of VSMC phenotypic switching and vascular remodeling and identified novel active CAB. These findings demonstrated that STAT3 can be a major regulator to control CIAPIN1/JAK2/STAT3 axis that may be a therapeutic target for treating vascular proliferative diseases.
4.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
5.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
6.Adjusted Global Antiphospholipid Syndrome Score Is Associated with End-Stage Kidney Disease in Patients with ANCA-Associated Vasculitis:A Single-Centre Pilot Study
Pil Gyu PARK ; Hyun Joon CHOI ; Yong-Beom PARK ; Sang-Won LEE
Yonsei Medical Journal 2025;66(6):337-345
Purpose:
The adjusted Global Antiphospholipid Syndrome (APS) Score (aGAPSS) was developed for assessing the probability of thrombotic events in APS patients. This study investigated whether the aGAPSS at diagnosis was associated with poor outcomes during follow-up in patients with antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV).
Materials and Methods:
This study included 170 AAV patients who had the results of APS-related antibodies at diagnosis but were not diagnosed with APS. All-cause mortality, end-stage kidney disease (ESKD), cerebrovascular accident, and acute coronary syndrome were considered poor AAV outcomes. The aGAPSS comprises five items, with 5, 4, 4, 3, and 1 points assigned to anticardiolipin antibodies, anti-β2-glycoprotein 1 antibodies, lupus anticoagulants, hyperlipidaemia, and arterial hypertension at AAV diagnosis, respectively.
Results:
The median age of the 170 patients [93 microscopic polyangiitis (MPA), 44 granulomatosis with polyangiitis (GPA), and 33 eosinophilic GPA (EGPA)] was 63.0 years. The optimal cut-off of the aGAPSS at diagnosis for ESKD during follow-up was set as two using the receiver operating characteristic curve. AAV patients with an aGAPSS ≥2 at diagnosis exhibited a significantly reduced ESKD-free survival rate compared to those with an aGAPSS <2 at diagnosis (p=0.045). Additionally, MPA and GPA patients, excluding EGPA patients for whom the median aGAPSS at diagnosis was close to 0, also showed similar patterns to the results among the 170 patients with AAV (p=0.021).
Conclusion
This study is the first to demonstrate that the aGAPSS at diagnosis was significantly associated with ESKD during follow-up in AAV patients without APS.
7.Immunologic Response and Effects of COVID-19Vaccines in Patients with Antineutrophil Cytoplasmic Antibody-Associated Vasculitis
Ki Hyun LEE ; Hyunsue DO ; Jun Yong CHOI ; Yong-Beom PARK ; Sinyoung KIM ; Sang-Won LEE ; Su Jin JEONG
Yonsei Medical Journal 2025;66(5):259-268
Purpose:
The immunological response and adverse effects of antineutrophil cytoplasmic antibody-associated vasculitis (AAV) in patients receiving coronavirus disease-2019 (COVID-19) vaccines remain unclear. We aimed to evaluate the effects of these vaccines on AAV disease activity.
Materials and Methods:
We reviewed the medical records of 52 patients with AAV who had received at least second doses of the COVID-19 vaccine and evaluated their immunogenicity by measuring the anti-spike (S) antibody (Ab) titer levels using the Roche Elecsys® immunoassay. Responses to the Birmingham Vasculitis Activity Score (BVAS) tool and 36-Item Short Form Survey before and after vaccination were obtained to assess AAV disease activity. Vaccine reactivity was measured using a standardized questionnaire.
Results:
We enrolled 52 patients with AAV. No differences were found between those who received second and third doses of vaccination in terms of AAV type, disease activity, vaccine type, or the use of immunosuppressive agents, including steroids. The median anti-S Ab titer was 3967.0 after third doses compared to 419.0 after second doses (p=0.001). Except for mycophenolate mofetil (MMF), when immunosuppressants were administered in conjunction with steroids, the Ab titer was higher after the third vaccination than that after the second dose. The BVAS remained unchanged before and after second and third doses. No life-threatening adverse events were reported.
Conclusion
Although COVID-19 vaccine may not produce sufficient antibodies in patients taking MMF, the vaccine did not exacerbate disease activity or cause severe side effects. Therefore, COVID-19 vaccines should be considered in patients with AAV.
8.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
9.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
10.Adjusted Global Antiphospholipid Syndrome Score Is Associated with End-Stage Kidney Disease in Patients with ANCA-Associated Vasculitis:A Single-Centre Pilot Study
Pil Gyu PARK ; Hyun Joon CHOI ; Yong-Beom PARK ; Sang-Won LEE
Yonsei Medical Journal 2025;66(6):337-345
Purpose:
The adjusted Global Antiphospholipid Syndrome (APS) Score (aGAPSS) was developed for assessing the probability of thrombotic events in APS patients. This study investigated whether the aGAPSS at diagnosis was associated with poor outcomes during follow-up in patients with antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV).
Materials and Methods:
This study included 170 AAV patients who had the results of APS-related antibodies at diagnosis but were not diagnosed with APS. All-cause mortality, end-stage kidney disease (ESKD), cerebrovascular accident, and acute coronary syndrome were considered poor AAV outcomes. The aGAPSS comprises five items, with 5, 4, 4, 3, and 1 points assigned to anticardiolipin antibodies, anti-β2-glycoprotein 1 antibodies, lupus anticoagulants, hyperlipidaemia, and arterial hypertension at AAV diagnosis, respectively.
Results:
The median age of the 170 patients [93 microscopic polyangiitis (MPA), 44 granulomatosis with polyangiitis (GPA), and 33 eosinophilic GPA (EGPA)] was 63.0 years. The optimal cut-off of the aGAPSS at diagnosis for ESKD during follow-up was set as two using the receiver operating characteristic curve. AAV patients with an aGAPSS ≥2 at diagnosis exhibited a significantly reduced ESKD-free survival rate compared to those with an aGAPSS <2 at diagnosis (p=0.045). Additionally, MPA and GPA patients, excluding EGPA patients for whom the median aGAPSS at diagnosis was close to 0, also showed similar patterns to the results among the 170 patients with AAV (p=0.021).
Conclusion
This study is the first to demonstrate that the aGAPSS at diagnosis was significantly associated with ESKD during follow-up in AAV patients without APS.

Result Analysis
Print
Save
E-mail