1.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
2.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
3.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
4.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
6.Evaluation of the application value of simple foot immobilization device in rectal cancer radiotherapy based on CBCT image-guided technology
Chinese Journal of Clinical Medicine 2025;32(4):654-658
Objective To explore the application value of the simple foot immobilization device in radiotherapy for rectal cancer based on the inter-fractional setup error acquired by image-guided technology of cone beam computed tomography (CBCT). Methods A total of 49 rectal cancer patients received volumetric modulated arc therapy (VMAT) in Zhongshan Hospital, Fudan University from February 2021 to February 2023 were included. Inter-fractional setup errors of each patient were analyzed. Any situation where the inter-fractional setup error exceeded 7 mm in any three-dimensional direction during the inter-fractional treatment course (the first treatment was excluded) was defined as a failed positioning reproducibility. Binary logistic regression was used for independent factor analysis of the failed positioning reproducibility. Results In the X-axis, Y-axis, and Z-axis directions, the patients’ inter-fractional setup errors were (2.50±1.97) mm, (2.18±1.73) mm, and (1.17±1.06) mm, respectively. Age (OR=0.880, 95%CI 0.801-0.967, P=0.008) and radiotherapy mode (OR=0.178, 95% CI 0.034-0.936, P=0.042) were independent factors affecting failed positioning reproducibility. The area under the curve (AUC) of age predicting failed positioning reproducibility was 0.780, with an optimal cut-off value of 53.5 years old. Conclusions The simple foot immobilization device has good inter-fractional setup reproducibility for patients with rectal cancer who received radiotherapy, but it is not recommended for patients younger than 53.5 years with rectal cancer undergoing preoperative radiotherapy.
7.Quality evaluation of Bidentis Herba based on HPLC fingerprint, multi-component content determination, and chemometrics.
Guo-Li SHI ; Xin-Feng WANG ; Wei-Qun LI ; Jian-Wei FAN ; Yong-Xia GUAN
China Journal of Chinese Materia Medica 2025;50(14):3944-3950
This study established the HPLC fingerprints and a multi-component content determination method for Bidens pilosa var. radiata and B. pilosa and conducted comprehensive evaluation by integrating fingerprint similarity comparison, cluster analysis(CA), and principal component analysis(PCA), aiming to provide a reference for the establishment of quality standards for Bidentis Herba. HPLC was launched on an Agilent Poroshell 120 EC-C_(18) chromatographic column(4.6 mm×250 mm, 4 μm) by gradient elution with a mobile phase of 0.1% aqueous phosphoric acid-acetonitrile at a flow rate of 0.7 mL·min~(-1), detection wavelength of 270 nm, column temperature of 25 ℃, and an injection volume of 5 μL. The fingerprint similarity of 20 batches of Bidentis Herba ranged from 0.775 to 0.979. A total of 20 common peaks were identified, and seven components were confirmed through comparison with reference substances: neochlorogenic acid, chlorogenic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, rutin, and hyperoside. These seven components exhibited good linearity within the ranges of 3.4-67.4, 33.0-660.3, 26.6-531.2, 3.5-70.5, 6.2-124.9, 2.4-48.3, and 4.6-91.5 μg·mL~(-1), respectively, with correlation coefficients(r) greater than 0.999. The average recovery rates ranged from 96.47% to 104.6%. CA and PCA classified the 20 batches of Bidentis Herba into two categories. PCA yielded two principal components, with a cumulative variance contribution rate of 80.557%. The established HPLC fingerprints and multi-component content determination method are simple and accurate, providing a scientific basis for the quality control and quality standard formulation of Bidentis Herba.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Chemometrics/methods*
;
Bidens/chemistry*
;
Principal Component Analysis
8.Quality evaluation of Bidentis Herba derived from different original plants based on HPLC fingerprints, characteristic chromatograms, multi-component content determination combined with chemical pattern recognition.
Guo-Li SHI ; Yun MA ; Feng-Xia SHEN ; Han-Wen DU ; Cong-Min LIU ; Rui-Xia WEI ; Yan-Fang LI ; Jian-Wei FAN ; Yong-Xia GUAN
China Journal of Chinese Materia Medica 2025;50(15):4284-4292
This study established the HPLC fingerprints, characteristic chromatograms, and a multi-component content determination method for Bidens bipinnata and B. biternata. The chemical pattern recognition analysis was then employed to clarify the characteristic indexes of quality differences between the two original plants of Bidentis Herba, providing a reference for establishing the quality standards of Bidentis Herba. HPLC was launched on an Agilent Poroshell 120 EC-C_(18) chromatographic column(4.6 mm×250 mm, 4 μm) by gradient elution with a mobile phase of 0.1% aqueous phosphoric acid-acetonitrile at a flow rate of 0.7 mL·min~(-1), detection wavelength of 270 nm, column temperature of 25 ℃, and an injection volume of 5 μL. The similarity between the fingerprints of 18 batches of Bidentis Herba samples and the common pattern(R) ranged from 0.572 to 0.933. A total of 23 chromatographic peaks were calibrated. Through comparison with the reference substances, six components(neochlorogenic acid, chlorogenic acid, isochlorogenic acid A, isochlorogenic acid B, rutin, and hyperoside) were identified and subjected to quantitative analysis. The characteristic fingerprints of B. bipinnata and B. biternata were calibrated with 20 and 17 characteristic peaks, respectively. Among them, peaks 8, 9, 22, and 23 were the characteristic peaks of B. bipinnata, and peak 7 was the characteristic peak of B. biternata, which can be used to distinguish the two original plants of Bidentis Herba. The relative standard deviation of the content of the above-mentioned six components ranged from 36% to 123%. The cluster analysis, principal component analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) classified the 18 batches of Bidentis Herba samples into two categories. Additionally, through the analysis of variable importance in projection(VIP) under OPLS-DA, three characteristic indexes, rutin, isochlorogenic acid A, and isochlorogenic acid B, were identified. The analytical method established in this study can comprehensively evaluate the consistency of Bidentis Herba samples derived from different original plants, specifically identify the differential components between them, and effectively distinguish the two original plants of Bidentis Herba, providing a basis for the differentiation between different original plants and the quality control of Bidentis Herba.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Bidens/chemistry*
9.Comparative epidemiology and treatment outcomes at trauma centers: A cross-national analysis of the United States and China.
Yong FU ; Liu-Yi FAN ; Xin-Jie LUO ; Lei LI ; Delbrynth P MITCHAO ; Kenji INABA ; Guan-Qiao LIU ; Bin YU
Chinese Journal of Traumatology 2025;28(6):399-403
PURPOSE:
Although there are significant differences between China and the United States (US) in trauma medical services, there has been no direct comparative research on the epidemiological data of trauma centers between the 2 countries. This study aims to fill this research gap by directly comparing trauma centers in China and the US, providing valuable data and insights for the development of trauma centers in both countries, promoting academic exchange and cooperation internationally, and enhancing the level of global trauma medical care.
METHODS:
This is a multicenter retrospective descriptive study. Data were collected for trauma patients with an injury severity score ≥16 treated from September 2013 to September 2019 at 2 hospital trauma centers in these 2 countries. Detailed clinical data (including injury mechanism, age, injury site, injury severity score, pre-hospital transport time, whether blood transfusion was performed, whether resuscitative thoracotomy was conducted, hospital and intensive care unit stay duration, the number of organ donor patients, mortality rates, and costs) were meticulously compiled and retrospectively analyzed to identify differences between the 2 trauma centers. The comparison was conducted using SPSS 23 software. Continuous variables are reported as median (Q1, Q3), and Mann Whitney U test is used to compare the median of continuous variables. Use clinically relevant critical points to classify continuous variables, with categorical variables represented as n (%), and comparisons were made between the 2 groups using the χ2 test or Fisher's exact test. Statistical significance was defined as a 2-sided p < 0.05.
RESULTS:
These results point to significant differences in trauma center capacity, pre-hospital transport times, treatment procedures, hospital stay duration, mortality rates, and costs between the 2 centers. The volume of patients in trauma centers is less in China (2465 vs. 5288). Pre-hospital transport time was notably longer in China (180 min vs. 14 min), and the rate of emergency blood transfusions was lower in China (18.4% vs. 50.6%), Emergency thoracotomy was not performed in China but was conducted in 9.8% of cases in the US. Hospitalization costs were significantly lower in China than in the US ($5847 vs. $75,671).
CONCLUSION
There are clear differences in trauma center capacity (number of patients treated), pre-hospital transport time, age distribution of injured patients, injury mechanisms, injury sites, whether emergency thoracotomy is performed, hospital costs, and length of stay between the 2 trauma centers in China and America. Understanding these differences can help us further recognize the characteristics of Eastern and Western trauma patients.
Humans
;
China/epidemiology*
;
Trauma Centers/statistics & numerical data*
;
Retrospective Studies
;
United States/epidemiology*
;
Male
;
Female
;
Wounds and Injuries/therapy*
;
Middle Aged
;
Adult
;
Injury Severity Score
;
Length of Stay/statistics & numerical data*
;
Treatment Outcome
10.Optimized lipid nanoparticles enable effective CRISPR/Cas9-mediated gene editing in dendritic cells for enhanced immunotherapy.
Kuirong MAO ; Huizhu TAN ; Xiuxiu CONG ; Ji LIU ; Yanbao XIN ; Jialiang WANG ; Meng GUAN ; Jiaxuan LI ; Ge ZHU ; Xiandi MENG ; Guojiao LIN ; Haorui WANG ; Jing HAN ; Ming WANG ; Yong-Guang YANG ; Tianmeng SUN
Acta Pharmaceutica Sinica B 2025;15(1):642-656
Immunotherapy has emerged as a revolutionary approach to treat immune-related diseases. Dendritic cells (DCs) play a pivotal role in orchestrating immune responses, making them an attractive target for immunotherapeutic interventions. Modulation of gene expression in DCs using genome editing techniques, such as the CRISPR-Cas system, is important for regulating DC functions. However, the precise delivery of CRISPR-based therapies to DCs has posed a significant challenge. While lipid nanoparticles (LNPs) have been extensively studied for gene editing in tumor cells, their potential application in DCs has remained relatively unexplored. This study investigates the important role of cholesterol in regulating the efficiency of BAMEA-O16B lipid-assisted nanoparticles (BLANs) as carriers of CRISPR/Cas9 for gene editing in DCs. Remarkably, BLANs with low cholesterol density exhibit exceptional mRNA uptake, improved endosomal escape, and efficient single-guide RNA release capabilities. Administration of BLANmCas9/gPD-L1 results in substantial PD-L1 gene knockout in conventional dendritic cells (cDCs), accompanied by heightened cDC1 activation, T cell stimulation, and significant suppression of tumor growth. The study underscores the pivotal role of cholesterol density within LNPs, revealing potent influence on gene editing efficacy within DCs. This strategy holds immense promise for the field of cancer immunotherapy, offering a novel avenue for treating immune-related diseases.

Result Analysis
Print
Save
E-mail