1.Design and application of a combination dressing for open-window central venous catheters
Ting ZHOU ; Lei JIANG ; Lin HUA ; Yuan QIU ; Yinying HE ; Youquan ZHOU ; Yuxuan GUO ; Chunrui FAN ; Changwen WU
Chinese Journal of Practical Nursing 2025;41(8):601-607
Objective:To explore the safety, economic benefits, and clinical application effect of the new practical patent open window central venous catheter combination dressing (Patent No.ZL 202121652858.8).Methods:From October 2022 to October 2023, a randomized controlled trial was conducted. A total of 120 tumor patients in Yunnan Cancer Hospital with indwelling central venous catheters who met the inclusion and exclusion criteria were randomly divided into three groups at a ratio of 1∶1∶1 with random digit table, with 40 patients in each group: control group 1, control group 2, and the experimental group. In control group 1, Smith & Nephew IV 3000 dressing was used, in control group 2, 3M transparent dressing was used; and in the experimental group, the self - developed fenestrated central venous catheter combined dressing by the researchers was used for catheter maintenance. The skin surface bacterial colonization, the occurrence of medical adhesive-related skin injuries, catheter maintenance time, and maintenance costs were compared among the three groups.Results:In control group 1, there were 21 males and 19 females, with an average age of (51.53 ± 12.01) years. In control group 2, there were 22 males and 18 females, with an average age of (54.00 ± 11.03) years. In the experimental group, there were 19 males and 21 females, with an average age of (53.60 ± 9.41) years. During the 72 - hour observation period, 1, 3, and 2 cases of bacterial colonization occurred in control group 1, control group 2, and the experimental group respectively, and there was no significant difference among the three groups ( χ2 = 1.10, P = 0.577). No medical adhesive - related skin injury occurred in the experimental group, and there was a significant difference compared with the 4 cases in control group 2 ( χ2 = 4.21, P = 0.040). The average catheter maintenance time and maintenance cost in the experimental group were (15.20 ± 1.56) minutes and (8.11 ± 1.35) yuan respectively. Compared with (21.05 ± 3.31) minutes and (13.16 ± 1.03) yuan in control group 1, the differences were statistically significant ( t = 5.85, 5.05, both P<0.001). Compared with (21.08 ± 3.00) minutes and (15.17 ± 1.63) yuan in control group 2, the differences were also statistically significant ( t = 5.88, 7.06, both P<0.001). Conclusions:The open-window central venous catheter combination dressing designed in this study can effectively reduce the incidence of medical adhesive-related skin injury, and also has a better role in saving maintenance time and reducing maintenance costs, especially for patients who need repeated dressing changes at the puncture point for treatment with the advantages of, convenience, economy, speed, firm fixation and safety.
2.Design and application of a combination dressing for open-window central venous catheters
Ting ZHOU ; Lei JIANG ; Lin HUA ; Yuan QIU ; Yinying HE ; Youquan ZHOU ; Yuxuan GUO ; Chunrui FAN ; Changwen WU
Chinese Journal of Practical Nursing 2025;41(8):601-607
Objective:To explore the safety, economic benefits, and clinical application effect of the new practical patent open window central venous catheter combination dressing (Patent No.ZL 202121652858.8).Methods:From October 2022 to October 2023, a randomized controlled trial was conducted. A total of 120 tumor patients in Yunnan Cancer Hospital with indwelling central venous catheters who met the inclusion and exclusion criteria were randomly divided into three groups at a ratio of 1∶1∶1 with random digit table, with 40 patients in each group: control group 1, control group 2, and the experimental group. In control group 1, Smith & Nephew IV 3000 dressing was used, in control group 2, 3M transparent dressing was used; and in the experimental group, the self - developed fenestrated central venous catheter combined dressing by the researchers was used for catheter maintenance. The skin surface bacterial colonization, the occurrence of medical adhesive-related skin injuries, catheter maintenance time, and maintenance costs were compared among the three groups.Results:In control group 1, there were 21 males and 19 females, with an average age of (51.53 ± 12.01) years. In control group 2, there were 22 males and 18 females, with an average age of (54.00 ± 11.03) years. In the experimental group, there were 19 males and 21 females, with an average age of (53.60 ± 9.41) years. During the 72 - hour observation period, 1, 3, and 2 cases of bacterial colonization occurred in control group 1, control group 2, and the experimental group respectively, and there was no significant difference among the three groups ( χ2 = 1.10, P = 0.577). No medical adhesive - related skin injury occurred in the experimental group, and there was a significant difference compared with the 4 cases in control group 2 ( χ2 = 4.21, P = 0.040). The average catheter maintenance time and maintenance cost in the experimental group were (15.20 ± 1.56) minutes and (8.11 ± 1.35) yuan respectively. Compared with (21.05 ± 3.31) minutes and (13.16 ± 1.03) yuan in control group 1, the differences were statistically significant ( t = 5.85, 5.05, both P<0.001). Compared with (21.08 ± 3.00) minutes and (15.17 ± 1.63) yuan in control group 2, the differences were also statistically significant ( t = 5.88, 7.06, both P<0.001). Conclusions:The open-window central venous catheter combination dressing designed in this study can effectively reduce the incidence of medical adhesive-related skin injury, and also has a better role in saving maintenance time and reducing maintenance costs, especially for patients who need repeated dressing changes at the puncture point for treatment with the advantages of, convenience, economy, speed, firm fixation and safety.
3.A systematic review of the reduction of neonatal PICC catheter associated infection with the frequency of replacement dressing
Tingting LI ; Yinying HUANG ; Wenjing HE ; Sufen DENG ; Yumin LIN ; Jinhua GAO
Chinese Journal of Practical Nursing 2018;34(5):391-396
Objective To evaluate the effects on catheter related blood stream infection by different dressing frequency of peripherally inserted central catheter(PICC)with neonates. Methods A systematic review of randomized controlled trials (RCTs) from databases, Data were searched about the transparent dressing replacement frequency for neonatal PICC catheterization. The meta-analysis was performed by using RevMan 5.2 software. Results Nine RCTs were included in a total of 1 730 patients. Meta analysis showed that there was no significant difference in the incidence of PICC puncture dressing, catheter-related infections (including puncture port infection, catheter-related blood flow infection, catheter bacterial colonization) at every 3, 5, and 7 days (P> 0.05). Conclusion the dressing of PICC catheter are replaced will not increase the incidence of catheter-related infections within 7 days, throughout the more appropriate frequency of dressing replacement is once every 7 days.
4.Effects of extended nursing combined with PDSA circle and based on positive psychology on self-efficacy ;of patients with colostomy
Xiaoxia HE ; Baoying PAN ; Xuehu XU ; Rong CHEN ; Yinying YAN ; Ruilian QU ; Hongjuan YANG
Chinese Journal of Modern Nursing 2016;22(36):5202-5206,5207
Objective To explore the function of extended nursing combined with PDSA circle and based on positivepsychology in improving self-efficacy of patients with colostomy. Methods A total of 80 patients with colostomy match the inclusion and exclusion standard from December 2014 to December 2015, were divided into the control group and the intervention group according to the order of discharge date.Patients in the control group received conventional extended nursing, while patients in the intervention group received extended nursing combined with PDSA circle and based on positivepsychology, and interventions were conducted a week, a month, two months, three months after discharge. Patients were evaluated by stoma related self-efficacy questionnaire before the intervention, after the fourth intervention and 3 months after intervention ( T0 , T1 ,T2 ) . Results There were significant differences in the dimensions, independent items and total scores of stoma related self-efficacy between two groups at different time after intervention except the item of confidence in sexual life (P<0.05), and they also had interactive effect (P<0.05).There was significant difference in the main effect of intervention time for the single item “confidence in sexual life” (P<0.05). In the intervention group, the scores of dimensions, independent items and total scores of stoma related self-efficiency after intervention and three months after intervention were significantly higher than those before intervention. Conclusions The extended nursing combined with PDSA circle and based on positivepsychology can improve the self-efficacy of patients with colostomy.

Result Analysis
Print
Save
E-mail