1.Comparison of CLAUS and POCURM in the etiological diagnosis of acute respiratory distress
Feilong XIAO ; Jianghua CHENG ; Yingwei DING ; Yun MAO
China Modern Doctor 2025;63(8):21-23,32
Objective To explore the value of cardiopulmonary and additional ultrasound(CLAUS)protocol and point-of-care ultrasound rapid management(POCURM)protocol in etiological diagnosis of acute respiratory distress in critically ill patients in the emergency room.Methods A total of 242 patients with acute respiratory distress admitted to Jinhua City Central Hospital from January 2022 to January 2024 were selected as the research subjects.According to the final diagnosis after discharge,they were divided into cardiogenic group(n=144)and pulmonary group(n=98).Compare the CLAUS findings of two groups and accuracy of two protocols in diagnosing etiology of acute respiratory distress.Results The history of heart disease in cardiogenic group was higher than that in pulmonary group,and difference was statistically significant(P<0.05).The lung disease history of patients in cardiogenic group was lower than that in pulmonary group,and difference was statistically significant(P<0.05).The proportion of pleural smoothness/slight thickening,sliding presence/slight weakening,left heart dysfunction,right heart dysfunction,and B-line pulmonary ultrasound scores in cardiogenic group were higher than those in pulmonary group,and differences were statistically significant(P<0.05).The sensitivity,specificity of POCURM protocol for diagnosing acute respiratory distress were 90.28%,91.84%.The sensitivity,specificity of CLAUS protocol for diagnosing acute respiratory distress were 96.53%,97.96%.Conclusion CLAUS regimen can effectively diagnose specific causes of acute respiratory distress in patients,with higher accuracy than POCURM regimen.
2.Preparation of quality control materials for SARS-CoV-2 variants based on MS2 phage virus-like particles
Ran ZHAO ; Yingwei CHEN ; Chengxiang CHU ; Zhongqiang HUANG ; Weijie DING ; Xueliang WANG
Chinese Journal of Clinical Laboratory Science 2025;43(10):773-779
Objective To prepare a variety of quality control(QC)materials for SARS-CoV-2 variants as an addition to the conven-tional SARS-CoV-2 nucleic acid QC products for the laboratory detection of mutant strains by optimizing the preparation and purification process of MS2 phage virus-like particle(VLP)technique,and evaluate their performances.Methods The typical mutation sequence fragments or full length S genes were designed and synthesized according to the genomic information of SARS-CoV-2 variants.Then,they were inserted into the downstream of maturase gene,coat protein and the pac-site of MS2 phage to construct a series of recombi-nant expression vectors.After induced by the prokaryotic expression system,the VLP products were purified through the polyethylenei-mine precipitation,ultrafiltration,nuclease digestion,and gel filtration chromatography.The obtained VLP were validated by the nucle-ic acid electrophoresis,protein electrophoresis,protein concentration determination,and fluorescence PCR,and their performances such as nucleic acid residue and stability were also evaluated.Results A total of 10 kinds of VLP containing the targeted sequences of the gene to be tested were prepared.The length of the foreign sequence wrapped in them ranged from 297 bp to 3 822 bp,which could be combined into a variety of QC materials for the mutation detection of different SARS-CoV-2 variants.The prepared VLP QC materials could not be effectively amplified without nucleic acid extraction or reverse transcription steps during the routine nucleic acid detection.The simulated QC samples remained stable after repeated freeze-thaw cycles.They could be stored stably for 2 months at 25 ℃ and 4 weeks at 37 ℃.Conclusion The established preparation and combined purification process of VLP QC materials can encapsulate vari-ous exogenous nucleic acid sequences with different lengths into the viral coat protein to form VLP,with high production efficiency.The VLP QC products prepared by the above process have stable performance and almost no residual exogenous nucleic acid,which can ef-fectively meet clinical requirements and ensure the quality of laboratory testing.
3.Preparation of quality control materials for SARS-CoV-2 variants based on MS2 phage virus-like particles
Ran ZHAO ; Yingwei CHEN ; Chengxiang CHU ; Zhongqiang HUANG ; Weijie DING ; Xueliang WANG
Chinese Journal of Clinical Laboratory Science 2025;43(10):773-779
Objective To prepare a variety of quality control(QC)materials for SARS-CoV-2 variants as an addition to the conven-tional SARS-CoV-2 nucleic acid QC products for the laboratory detection of mutant strains by optimizing the preparation and purification process of MS2 phage virus-like particle(VLP)technique,and evaluate their performances.Methods The typical mutation sequence fragments or full length S genes were designed and synthesized according to the genomic information of SARS-CoV-2 variants.Then,they were inserted into the downstream of maturase gene,coat protein and the pac-site of MS2 phage to construct a series of recombi-nant expression vectors.After induced by the prokaryotic expression system,the VLP products were purified through the polyethylenei-mine precipitation,ultrafiltration,nuclease digestion,and gel filtration chromatography.The obtained VLP were validated by the nucle-ic acid electrophoresis,protein electrophoresis,protein concentration determination,and fluorescence PCR,and their performances such as nucleic acid residue and stability were also evaluated.Results A total of 10 kinds of VLP containing the targeted sequences of the gene to be tested were prepared.The length of the foreign sequence wrapped in them ranged from 297 bp to 3 822 bp,which could be combined into a variety of QC materials for the mutation detection of different SARS-CoV-2 variants.The prepared VLP QC materials could not be effectively amplified without nucleic acid extraction or reverse transcription steps during the routine nucleic acid detection.The simulated QC samples remained stable after repeated freeze-thaw cycles.They could be stored stably for 2 months at 25 ℃ and 4 weeks at 37 ℃.Conclusion The established preparation and combined purification process of VLP QC materials can encapsulate vari-ous exogenous nucleic acid sequences with different lengths into the viral coat protein to form VLP,with high production efficiency.The VLP QC products prepared by the above process have stable performance and almost no residual exogenous nucleic acid,which can ef-fectively meet clinical requirements and ensure the quality of laboratory testing.
4.Comparison of CLAUS and POCURM in the etiological diagnosis of acute respiratory distress
Feilong XIAO ; Jianghua CHENG ; Yingwei DING ; Yun MAO
China Modern Doctor 2025;63(8):21-23,32
Objective To explore the value of cardiopulmonary and additional ultrasound(CLAUS)protocol and point-of-care ultrasound rapid management(POCURM)protocol in etiological diagnosis of acute respiratory distress in critically ill patients in the emergency room.Methods A total of 242 patients with acute respiratory distress admitted to Jinhua City Central Hospital from January 2022 to January 2024 were selected as the research subjects.According to the final diagnosis after discharge,they were divided into cardiogenic group(n=144)and pulmonary group(n=98).Compare the CLAUS findings of two groups and accuracy of two protocols in diagnosing etiology of acute respiratory distress.Results The history of heart disease in cardiogenic group was higher than that in pulmonary group,and difference was statistically significant(P<0.05).The lung disease history of patients in cardiogenic group was lower than that in pulmonary group,and difference was statistically significant(P<0.05).The proportion of pleural smoothness/slight thickening,sliding presence/slight weakening,left heart dysfunction,right heart dysfunction,and B-line pulmonary ultrasound scores in cardiogenic group were higher than those in pulmonary group,and differences were statistically significant(P<0.05).The sensitivity,specificity of POCURM protocol for diagnosing acute respiratory distress were 90.28%,91.84%.The sensitivity,specificity of CLAUS protocol for diagnosing acute respiratory distress were 96.53%,97.96%.Conclusion CLAUS regimen can effectively diagnose specific causes of acute respiratory distress in patients,with higher accuracy than POCURM regimen.
5.Value of pulmonary ultrasound B-line score,LVEF,IGFBP7 and NT-proBNP in differentiating cardiogenic acute dyspnea
Feilong XIAO ; Jianghua CHENG ; Yingwei DING ; Yun MAO
China Modern Doctor 2025;63(25):19-23
Objective Exploring the clinical value of pulmonary ultrasound B-line score,left ventricular ejection fraction(LVEF),insulin-like growth factor binding protein-7(IGFBP7),and N-terminal pro-brain natriuretic peptide(NT-proBNP)levels in diagnosing cardiogenic acute dyspnea.Methods A retrospective analysis was conducted on the clinical data of 80 patients with acute dyspnea diagnosed and treated at Jinhua Municipal Central Hospital from February 2021 to February 2024.According to the discharge diagnosis of patients,they were divided into cardiogenic group(cardiogenic acute dyspnea,50 cases)and non-cardiogenic group(non-cardiogenic acute dyspnea,30 cases).The pulmonary ultrasound B-line score,LVEF,IGFBP7 and NT-proBNP levels of two groups of patients were compared,their correlations were analyzed,and the receiver operating characteristic(ROC)curve was drawn to evaluate the diagnostic value of each index for cardiogenic acute dyspnea.Results There were no statistically significant differences in the clinical baseline data such as age,gender,body mass index,proportion of atrial fibrillation,urea nitrogen,serum creatinine,systolic blood pressure,arterial partial pressure of oxygen,heart rate and blood oxygen saturation between two groups of patients(P>0.05).The pulmonary ultrasound B-line score,the levels of IGFBP7 and NT-proBNP in cardiogenic group were significantly higher than those in non-cardiogenic group,and the LVEF was significantly lower than that in non-cardiogenic group(P<0.05).Pearson correlation analysis showed that the pulmonary ultrasound B-line score was positively correlated with both IGFBP7 and NT-proBNP(P<0.05),with no significant correlation with LVEF(P>0.05).The results of ROC curve showed that the pulmonary ultrasound B-line score,LVEF,IGFBP7 and NT-proBNP all had high diagnostic value for cardiogenic acute dyspnea,and the area under the curve were 0.917,0.855,0.946 and 0.925,respectively.Conclusion The pulmonary ultrasound B-line score,LVEF,IGFBP7,and NT-proBNP levels have high diagnostic value for cardiogenic acute dyspnea and are worthy of clinical promotion and application.
6.Chest contrast-enhanced CT combined with artificial intelligence iterative reconstruction for bronchial artery imaging
Youyong WEI ; Tiantian WANG ; Yingwei LUO ; Linyu LU ; Yanping DING ; Guoqing YAO ; Qinglian LI ; Xiaohui GUAN
Chinese Journal of Medical Imaging Technology 2025;41(4):530-534
Objective To investigate the value of chest contrast-enhanced CT(C-CECT)combined with artificial intelligence iterative reconstruction(AIIR)for bronchial artery(BA)imaging.Methods Seventy patients who underwent C-CECT were prospectively enrolled.The images were reconstructed with AIIR(AIIR group)and hybrid iterative reconstruction(HIR,HIR group),respectively.The overall image quality,the traceability of BA,the sharpness of BA and the diagnostic confidence of abnormalities of BA were subjectively graded using a 5-point scale by two radiologists,respectively.The subjective scores and inter-observer agreement were compared between groups.The noise(SD)in reconstructed images of thoracic aorta,pulmonary trunk,BA and spinal erectors,the contrast-to-noise ratio(CNR)of the above 3 arteries relative to spinal erectors,and the diameters of BA at the origin,bifurcation and pulmonary hilum were compared between groups.Results The scores of the overall image quality,the traceability of BA,the sharpness of BA and the diagnostic confidence of abnormalities of BA were all significantly higher in AIIR group than those in HIR group(all P<0.001),all with good inter-observer agreement(Kappa=0.46-0.73).SD of the aorta,pulmonary artery trunk,BA and erector spinal muscle in AIIR group were lower than those in HIR group,while CNR of above 3 arteries were higher than those in HIR group(all P<0.05).No significant difference of the diameter of BA at each position was found between groups(all P>0.05),while the consistency of measurement of AIIR group was higher than that of HIR group(intra-class correlation coefficient:0.89-0.94 vs.0.63-0.78).Conclusion C-CECT combined with AIIR could significantly improve imaging quality and diagnostic confidence of BA.
7.Chest contrast-enhanced CT combined with artificial intelligence iterative reconstruction for bronchial artery imaging
Youyong WEI ; Tiantian WANG ; Yingwei LUO ; Linyu LU ; Yanping DING ; Guoqing YAO ; Qinglian LI ; Xiaohui GUAN
Chinese Journal of Medical Imaging Technology 2025;41(4):530-534
Objective To investigate the value of chest contrast-enhanced CT(C-CECT)combined with artificial intelligence iterative reconstruction(AIIR)for bronchial artery(BA)imaging.Methods Seventy patients who underwent C-CECT were prospectively enrolled.The images were reconstructed with AIIR(AIIR group)and hybrid iterative reconstruction(HIR,HIR group),respectively.The overall image quality,the traceability of BA,the sharpness of BA and the diagnostic confidence of abnormalities of BA were subjectively graded using a 5-point scale by two radiologists,respectively.The subjective scores and inter-observer agreement were compared between groups.The noise(SD)in reconstructed images of thoracic aorta,pulmonary trunk,BA and spinal erectors,the contrast-to-noise ratio(CNR)of the above 3 arteries relative to spinal erectors,and the diameters of BA at the origin,bifurcation and pulmonary hilum were compared between groups.Results The scores of the overall image quality,the traceability of BA,the sharpness of BA and the diagnostic confidence of abnormalities of BA were all significantly higher in AIIR group than those in HIR group(all P<0.001),all with good inter-observer agreement(Kappa=0.46-0.73).SD of the aorta,pulmonary artery trunk,BA and erector spinal muscle in AIIR group were lower than those in HIR group,while CNR of above 3 arteries were higher than those in HIR group(all P<0.05).No significant difference of the diameter of BA at each position was found between groups(all P>0.05),while the consistency of measurement of AIIR group was higher than that of HIR group(intra-class correlation coefficient:0.89-0.94 vs.0.63-0.78).Conclusion C-CECT combined with AIIR could significantly improve imaging quality and diagnostic confidence of BA.
8.Value of pulmonary ultrasound B-line score,LVEF,IGFBP7 and NT-proBNP in differentiating cardiogenic acute dyspnea
Feilong XIAO ; Jianghua CHENG ; Yingwei DING ; Yun MAO
China Modern Doctor 2025;63(25):19-23
Objective Exploring the clinical value of pulmonary ultrasound B-line score,left ventricular ejection fraction(LVEF),insulin-like growth factor binding protein-7(IGFBP7),and N-terminal pro-brain natriuretic peptide(NT-proBNP)levels in diagnosing cardiogenic acute dyspnea.Methods A retrospective analysis was conducted on the clinical data of 80 patients with acute dyspnea diagnosed and treated at Jinhua Municipal Central Hospital from February 2021 to February 2024.According to the discharge diagnosis of patients,they were divided into cardiogenic group(cardiogenic acute dyspnea,50 cases)and non-cardiogenic group(non-cardiogenic acute dyspnea,30 cases).The pulmonary ultrasound B-line score,LVEF,IGFBP7 and NT-proBNP levels of two groups of patients were compared,their correlations were analyzed,and the receiver operating characteristic(ROC)curve was drawn to evaluate the diagnostic value of each index for cardiogenic acute dyspnea.Results There were no statistically significant differences in the clinical baseline data such as age,gender,body mass index,proportion of atrial fibrillation,urea nitrogen,serum creatinine,systolic blood pressure,arterial partial pressure of oxygen,heart rate and blood oxygen saturation between two groups of patients(P>0.05).The pulmonary ultrasound B-line score,the levels of IGFBP7 and NT-proBNP in cardiogenic group were significantly higher than those in non-cardiogenic group,and the LVEF was significantly lower than that in non-cardiogenic group(P<0.05).Pearson correlation analysis showed that the pulmonary ultrasound B-line score was positively correlated with both IGFBP7 and NT-proBNP(P<0.05),with no significant correlation with LVEF(P>0.05).The results of ROC curve showed that the pulmonary ultrasound B-line score,LVEF,IGFBP7 and NT-proBNP all had high diagnostic value for cardiogenic acute dyspnea,and the area under the curve were 0.917,0.855,0.946 and 0.925,respectively.Conclusion The pulmonary ultrasound B-line score,LVEF,IGFBP7,and NT-proBNP levels have high diagnostic value for cardiogenic acute dyspnea and are worthy of clinical promotion and application.
9.Tim-3 promoted renal ischemia/reperfusion injury through regulating mononuclear phagocyte system function
Yunshan GUO ; Yaohai DING ; Yingwei ZHANG ; Xiaoyu JIANG ; Hongdong LI ; Zhen LI ; Moyan LIU ; Yi LIU
Chinese Journal of Organ Transplantation 2018;39(2):109-115
Objective To investigate the effects of Tim-3 on the renal ischemia-reperfusion injury (IRI),and explore the role of monocyte-macrophage cell system.Methods Totally 72 C57BL/ 6 mice were randomly divided into four groups (n =18 each).(1) IR + Tim-3 rnAb group (experimental group):Each mouse was intraperitoneally injected with 200μg of anti-Tim-3 mAb and the IR model of mouse kidney was established after 1 day;(2) IR + IgG monoclonal antibody group (negative control group):each mouse was intraperitoneally injected with anti-IgG mAb (200 μg) and the IR model of mouse kidney was established after 1 day;(3) IR group:mouse kidney IR model was established only;(4) Control group:mouse kidney IR model was not established.At 6,24 and 48 h after IR respectively,venous blood of 6 mice in each group was taken from the infrarenal vein.Scr and CystinC were detected and PAS staining was used to observe the pathological change of renal tissues.Cell apoptosis was detected by TUNEL staining.Pax,bcl-2 and caspase-3 expression in renal tissue was detected by Western blotting.Immunohistochemistry was used to detect the distribution of Tim-3 and activated macrophage cells.Flow cytometry and ELISA were used to evaluate the level of Tim-3 and inflammatory cytokines secretion respectively.Results Compared with control group,the Tim-3 expression was dramatically increased in IR group and I/R + Tim-3 mAb group.The serum Scr and CystinC levels were increased in IR group,and Tim-3 blocking decreased the levels of serum Scr and CystinC (P<0.05).PAS and TUNEL staining showed that renal injury score and apoptotic index were higher in IR group than those in control group.Tim-3mAb significantly decreased those markers,and ameliorated the renal tubulointerstitial injury induced by IRk The expression levels of Caspase-3 and Bax/bcl-2 was increased in IR group,but deceased by Tim-3mAb.IR induced F4/80 + distribution and inflammatory cytokines secretion in renal tubular interstitial tissues,while Tim-3mAb down-regulated F4/80 + activation and the levels of inflammatory cytokines.Conclusion The findings demonstrated Tim-3 may promoted renal IRI through regulating mononuclear phagocyte system function.
10.Analysis on value of combined detection of Hcy,hs-CRP and Lp-PLA2 in diagnosis of ischemic cerebral stroke
Meng DING ; Yingwei WU ; Shoujun XIE ; Xueli GENG ; Yaju WANG
International Journal of Laboratory Medicine 2017;38(14):1898-1900
Objective To analyze the significance of levels and combined detection of plasma homocysteine(Hcy),high-sensitivity C reactive protein(hs-CRP) and lipoprotein-associated phospholipase A2(Lp-PLA2) in patients with ischemic cerebral stroke(ICS).Methods A total of 140 patients with ICS were selected into ICS group,and 100 healthy individuals were recruited in the control group.The plasma levels of Hcy,hs-CRP,Lp-PLA2 were examined,then the positive rates of them were statistically analyzed.Analyzed the value of the levels and joint detection of Hcy,hs-CRP and Lp-PLA2.Results The plasma levels and the positive rates of Hcy,hs-CRP and Lp-PLA2 in ICS group were statistically higher than those in the control group(P<0.05).The area under the receiver-operating characteristic curve of combined detection of Hcy,hs-CRP and Lp-PLA2 in diagnosis of ICS was 0.949,the sensitivity was 0.850,and the specificity was 0.807,which were higher than Hcy,hs-CRP and Lp-PLA2 alone.Conclusion The plasma levels of Hcy,hs-CRP and Lp-PLA2 increase in ICS patients,and the combined detection of the three indicators might improve the early diagnostic value of ICS.

Result Analysis
Print
Save
E-mail