1.Study on core genes and potential immunological and metabolic mechanisms associated with Tongmai yangxin pills in the treatment of coronary heart disease
Junchi GUO ; Mingyan ZHANG ; Yingqiang ZHAO ; Meijuan LU
China Pharmacy 2025;36(17):2148-2153
OBJECTIVE To identify core genes associated with the treatment of coronary heart disease (CHD) with Tongmai yangxin pills, and predict their potential immunological and metabolic mechanisms. METHODS Mendelian randomization (MR) analysis was conducted using protein quantitative trait loci (pQTL) data from the UK Biobank and Icelandic,and data from genome- wide association study to screen core genes related to Tongmai yangxin pills in the treatment of CHD. Gene expression changes were further validated using transcriptomic sequencing data. Mediation analyses of immune cells and plasma metabolites were subsequently performed to explore the downstream regulatory networks of these core genes. RESULTS A total of 62 positive pQTL genes showed significant causal associations with CHD. MR analysis combined with transcriptomic sequencing validation identified three core genes FAM3D,OXT, and ENPP5-associated with Tongmai yangxin pills in the treatment of CHD. The transcriptomic sequencing results showed that after treatment with Tongmai yangxin pills, the expression levels of FAM3D and OXT were significantly reduced (P<0.01), while the expression level of ENPP5 was significantly increased (P<0.05). Mediation analyses between immune cells and plasma metabolites indicated that these genes may positively or negatively regulate CHD through immune pathways involving regulatory T cells and myeloid dendritic cells expressing CD11c and CD62L, as well as through metabolic pathways related to lipid and fatty acid metabolism, cholesterol metabolism, and bile acid metabolism. CONCLUSIONS This study identified FAM3D,OXT, and ENPP5 as core genes associated with the treatment of CHD by Tongmai yangxin pills, which may exert therapeutic effects via modulation of immune cells and plasma metabolic pathways involving fatty acids and bile acids.
2.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
3.The role of diagnostic whole body scan in decision-making of 131I treatment for differentiated thyroid cancer
Xiaotong JIANG ; Jinchuan LIU ; Yingqiang ZHANG ; Tong WANG ; Ning GUO ; Yuqing SUN ; Cong SHI ; Bing YAN ; Yansong LIN
China Oncology 2025;35(1):77-84
Background and purpose:As one of the first-line treatment methods for differentiated thyroid cancer(DTC),131I treatment is an important therapeutic approach for most patients with medium-high recurrence risk DTC after total or near-total thyroidectomy.Risk stratification and real-time dynamic assessment before 131I treatment after surgery are important steps in deciding on 131I treatment,enabling individualized treatment.This retrospective study aimed to explore the role of diagnostic whole body scan(DxWBS)in the decision-making of treatment for DTC after surgery and before 131I therapy.Methods:DTC patients who underwent pre-ablation evaluation were included.Patients were divided into low,medium and high sTg groups based on their pre-131I treatment stimulated thyroglobulin(sTg)levels(<1 ng/mL,1 ng/mL≤sTg<10 ng/mL,sTg≥10 ng/mL).The concordance rates of DxWBS and post treatment whole body scan(RxWBS)in each patient of the whole cohort were compared.The lesion detection rate between DxWBS and RxWBS in different sTg level groups was also explored.The"thyroid stunning effect"by DxWBS was evaluated by RxWBS.Through these analyses,the role of DxWBS in 131I treatment decision-making and its predicting treatment objectives were assessed.This study was approved by the Ethics Committee of Peking Union Medical College Hospital,Peking Union Medical College,Chinese Academy of Medical Sciences(ethics number:JS-2151).Results:A total of 91 patients were included.The low,medium and high sTg groups accounted for 15.4%(14/91),34.1%(31/91)and 50.5%(46/91)of the patients,respectively.Comparison of DxWBS and RxWBS results in the same patients in each sTg group showed no evidence of a stunning effect on 131I treatment.The overall concordance rate between DxWBS and RxWBS was 89.0%(81/91);In different sTg level groups was 100.0%(14/14),90.3%(28/31),84.8%(39/46)respectively.Taking sTg levels into consideration,DxWBS accurately predicted the need for total thyroidectomy,with a 100%(20/20)agreement with RxWBS.Among the 71 patients who received adjuvant therapy and/or remnant ablation due to suspected elevated Tg or high recurrence risk stratification or the iodine-avid metastatic lesions identified by DxWBS,87.5%(63/71)showed only residual thyroid tissue by DxWBS;Through the purpose verification by RxWBS and single photon emission computed tomography(SPECT)/CT,only 12.7%(9/71)of cases were verified as adjuvant or tumoricidal treatment due to iodine-avid cervical lymph node and/or lung metastasis identified by RxWBS,87.3%(62/71)were residual thyroid ablation.In the medium and high sTg group,the overall detection rate of functional cervical lymph node metastasis by DxWBS and RxWBS was 5.5%(5/91).For the detection of functional lung metastases,the overall detection rate of DxWBS was slightly lower than that of RxWBS(3.3%vs 5.5%).This indicates that DxWBS can be used to accurately pre-judge the purposes of 131I treatment,particularly for thyroid ablation and adjuvant therapy.Conclusion:DxWBS did not induce"thyroid stunning"effect.Integrating DxWBS as a theranostic tool into the real-time decision-making and evaluation system of 131I treatment,as well as with sTg and other biochemical indicators,may help to bridge the limitations of static evaluations based on pathology and clinical data,and provides a clear understanding and more precise objectives of 131I treatment.
4.The role of diagnostic whole body scan in decision-making of 131I treatment for differentiated thyroid cancer
Xiaotong JIANG ; Jinchuan LIU ; Yingqiang ZHANG ; Tong WANG ; Ning GUO ; Yuqing SUN ; Cong SHI ; Bing YAN ; Yansong LIN
China Oncology 2025;35(1):77-84
Background and purpose:As one of the first-line treatment methods for differentiated thyroid cancer(DTC),131I treatment is an important therapeutic approach for most patients with medium-high recurrence risk DTC after total or near-total thyroidectomy.Risk stratification and real-time dynamic assessment before 131I treatment after surgery are important steps in deciding on 131I treatment,enabling individualized treatment.This retrospective study aimed to explore the role of diagnostic whole body scan(DxWBS)in the decision-making of treatment for DTC after surgery and before 131I therapy.Methods:DTC patients who underwent pre-ablation evaluation were included.Patients were divided into low,medium and high sTg groups based on their pre-131I treatment stimulated thyroglobulin(sTg)levels(<1 ng/mL,1 ng/mL≤sTg<10 ng/mL,sTg≥10 ng/mL).The concordance rates of DxWBS and post treatment whole body scan(RxWBS)in each patient of the whole cohort were compared.The lesion detection rate between DxWBS and RxWBS in different sTg level groups was also explored.The"thyroid stunning effect"by DxWBS was evaluated by RxWBS.Through these analyses,the role of DxWBS in 131I treatment decision-making and its predicting treatment objectives were assessed.This study was approved by the Ethics Committee of Peking Union Medical College Hospital,Peking Union Medical College,Chinese Academy of Medical Sciences(ethics number:JS-2151).Results:A total of 91 patients were included.The low,medium and high sTg groups accounted for 15.4%(14/91),34.1%(31/91)and 50.5%(46/91)of the patients,respectively.Comparison of DxWBS and RxWBS results in the same patients in each sTg group showed no evidence of a stunning effect on 131I treatment.The overall concordance rate between DxWBS and RxWBS was 89.0%(81/91);In different sTg level groups was 100.0%(14/14),90.3%(28/31),84.8%(39/46)respectively.Taking sTg levels into consideration,DxWBS accurately predicted the need for total thyroidectomy,with a 100%(20/20)agreement with RxWBS.Among the 71 patients who received adjuvant therapy and/or remnant ablation due to suspected elevated Tg or high recurrence risk stratification or the iodine-avid metastatic lesions identified by DxWBS,87.5%(63/71)showed only residual thyroid tissue by DxWBS;Through the purpose verification by RxWBS and single photon emission computed tomography(SPECT)/CT,only 12.7%(9/71)of cases were verified as adjuvant or tumoricidal treatment due to iodine-avid cervical lymph node and/or lung metastasis identified by RxWBS,87.3%(62/71)were residual thyroid ablation.In the medium and high sTg group,the overall detection rate of functional cervical lymph node metastasis by DxWBS and RxWBS was 5.5%(5/91).For the detection of functional lung metastases,the overall detection rate of DxWBS was slightly lower than that of RxWBS(3.3%vs 5.5%).This indicates that DxWBS can be used to accurately pre-judge the purposes of 131I treatment,particularly for thyroid ablation and adjuvant therapy.Conclusion:DxWBS did not induce"thyroid stunning"effect.Integrating DxWBS as a theranostic tool into the real-time decision-making and evaluation system of 131I treatment,as well as with sTg and other biochemical indicators,may help to bridge the limitations of static evaluations based on pathology and clinical data,and provides a clear understanding and more precise objectives of 131I treatment.
5.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
6.Multicenter expert recommendations on interventional valve-in-valve technology for mitral bioprosthetic valve destruction in China
Haibo ZHANG ; Xiangbin PAN ; Yingqiang GUO ; Lai WEI ; Jian YANG ; Daxin ZHOU ; Yongjian WU ; Xu MENG ; Liming LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(08):1090-1095
Mitral valve replacement is one of the most common heart valve surgeries in China. In recent years, with the increase in degenerative valve diseases, older patients, and the progress of anti-calcification technology of biological valves, the proportion of mitral valve biological valve replacement has been increasing year by year. After the damage of traditional mitral valve biological valves, re-operation of valve replacement with thoracotomy is required. However, the adhesion between the heart and sternum, as well as the damage caused by cardiopulmonary bypass and cardiac arrest, can cause significant trauma to elderly patients and those with multiple organ dysfunction, leading to increased mortality and complication rates. In recent years, interventional valve surgery, especially transcatheter valve-in-valve surgery, has developed rapidly. This procedure can correct the damaged mitral valve function without stopping the heart, but there are still many differences between its technical process and conventional aortic valve replacement surgery. Therefore, organizing and writing multicenter expert recommendations on the technical process of transcatheter valve-in-valve surgery for damaged mitral valve biological valves is of great significance for the training and promotion of this technology.
7.A wearable six-minute walk-based system to predict postoperative pulmonary complications after cardiac valve surgery: an exploratory study.
Yuqiang WANG ; Jiachen WANG ; Jian ZHANG ; Zeruxin LUO ; Yingqiang GUO ; Zhengbo ZHANG ; Pengming YU
Journal of Biomedical Engineering 2023;40(6):1117-1125
In recent years, wearable devices have seen a booming development, and the integration of wearable devices with clinical settings is an important direction in the development of wearable devices. The purpose of this study is to establish a prediction model for postoperative pulmonary complications (PPCs) by continuously monitoring respiratory physiological parameters of cardiac valve surgery patients during the preoperative 6-Minute Walk Test (6MWT) with a wearable device. By enrolling 53 patients with cardiac valve diseases in the Department of Cardiovascular Surgery, West China Hospital, Sichuan University, the grouping was based on the presence or absence of PPCs in the postoperative period. The 6MWT continuous respiratory physiological parameters collected by the SensEcho wearable device were analyzed, and the group differences in respiratory parameters and oxygen saturation parameters were calculated, and a prediction model was constructed. The results showed that continuous monitoring of respiratory physiological parameters in 6MWT using a wearable device had a better predictive trend for PPCs in cardiac valve surgery patients, providing a novel reference model for integrating wearable devices with the clinic.
Humans
;
Lung
;
Walking/physiology*
;
Walk Test
;
Heart Valves/surgery*
;
Postoperative Period
;
Postoperative Complications/etiology*
8.Preclinical and early clinical studies of a novel compound SYHA1813 that efficiently crosses the blood-brain barrier and exhibits potent activity against glioblastoma.
Yingqiang LIU ; Zhengsheng ZHAN ; Zhuang KANG ; Mengyuan LI ; Yongcong LV ; Shenglan LI ; Linjiang TONG ; Fang FENG ; Yan LI ; Mengge ZHANG ; Yaping XUE ; Yi CHEN ; Tao ZHANG ; Peiran SONG ; Yi SU ; Yanyan SHEN ; Yiming SUN ; Xinying YANG ; Yi CHEN ; Shanyan YAO ; Hanyu YANG ; Caixia WANG ; Meiyu GENG ; Wenbin LI ; Wenhu DUAN ; Hua XIE ; Jian DING
Acta Pharmaceutica Sinica B 2023;13(12):4748-4764
Glioblastoma (GBM) is the most common and aggressive malignant brain tumor in adults and is poorly controlled. Previous studies have shown that both macrophages and angiogenesis play significant roles in GBM progression, and co-targeting of CSF1R and VEGFR is likely to be an effective strategy for GBM treatment. Therefore, this study developed a novel and selective inhibitor of CSF1R and VEGFR, SYHA1813, possessing potent antitumor activity against GBM. SYHA1813 inhibited VEGFR and CSF1R kinase activities with high potency and selectivity and thus blocked the cell viability of HUVECs and macrophages and exhibited anti-angiogenetic effects both in vitro and in vivo. SYHA1813 also displayed potent in vivo antitumor activity against GBM in immune-competent and immune-deficient mouse models, including temozolomide (TMZ) insensitive tumors. Notably, SYHA1813 could penetrate the blood-brain barrier (BBB) and prolong the survival time of mice bearing intracranial GBM xenografts. Moreover, SYHA1813 treatment resulted in a synergistic antitumor efficacy in combination with the PD-1 antibody. As a clinical proof of concept, SYHA1813 achieved confirmed responses in patients with recurrent GBM in an ongoing first-in-human phase I trial. The data of this study support the rationale for an ongoing phase I clinical study (ChiCTR2100045380).
9.Expert recommendations for standardized perioperative management after transapical transcatheter aortic valve implantation
Haibo ZHANG ; Xiaotong HOU ; Yingqiang GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(07):927-935
The technique of transcatheter aortic valve implantation has become increasingly mature. Although the transapical approach has a certain degree of minimally invasive trauma, it still has the characteristics such as heart beating without cardiopulmonary bypass, and the low technical requirements of catheter guide wire. In particular, the valve path is short and coaxial, which is easy to manipulate, and pure regurgitation and stenosis can be easily operated and are not subject to the limit of peripheral artery stenosis. It is still one of China's main approaches for transcatheter aortic valve replacement. Its perioperative management still has specific features and differs from the femoral artery approach. In addition, there is little relevant literature abroad. Therefore, domestic experts in this field were organized to discuss the development of perioperative management specifications to provide reference and techniques support for developing this field in China and further improve the quality of clinical operation and perioperative management. It will provide more safe and more effective medical services to these patients.
10.Expert consensus on the use of human serum albumin in adult cardiac surgery.
Fei XIANG ; Fuhua HUANG ; Jiapeng HUANG ; Xin LI ; Nianguo DONG ; Yingbin XIAO ; Qiang ZHAO ; Liqiong XIAO ; Haitao ZHANG ; Cui ZHANG ; Zhaoyun CHENG ; Liangwan CHEN ; Jimei CHEN ; Huishan WANG ; Yingqiang GUO ; Nan LIU ; Zhe LUO ; Xiaotong HOU ; Bingyang JI ; Rong ZHAO ; Zhenxiao JIN ; Robert SAVAGE ; Yang ZHAO ; Zhe ZHENG ; Xin CHEN
Chinese Medical Journal 2023;136(10):1135-1143

Result Analysis
Print
Save
E-mail