1.Plasma miRNA testing in the differential diagnosis of very early-stage hepatocellular carcinoma: a multicenter real-world study
Jie HU ; Ying XU ; Ao HUANG ; Lei YU ; Zheng WANG ; Xiaoying WANG ; Xinrong YANG ; Zhenbin DING ; Qinghai YE ; Yinghong SHI ; Shuangjian QIU ; Huichuan SUN ; Qiang GAO ; Jia FAN ; Jian ZHOU
Chinese Journal of Clinical Medicine 2025;32(3):350-354
Objective To explore the application of plasma 7 microRNA (miR7) testing in the differential diagnosis of very early-stage hepatocellular carcinoma (HCC). Methods This study is a multicenter real-world study. Patients with single hepatic lesion (maximum diameter≤2 cm) who underwent plasma miR7 testing at Zhongshan Hospital, Fudan University, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Anhui Provincial Hospital, and Peking University People’s Hospital between January 2019 and December 2024 were retrospectively enrolled. Patients were divided into very early-stage HCC group and non-HCC group, and the clinical pathological characteristics of the two groups were compared. The value of plasma miR7 levels, alpha-fetoprotein (AFP), and des-gamma-carboxy prothrombin (DCP) in the differential diagnosis of very early-stage HCC was evaluated using receiver operating characteristic (ROC) curves and area under the curve (AUC). In patients with both negative AFP and DCP (AFP<20 ng/mL, DCP<40 mAU/mL), the diagnostic value of plasma miR7 for very early-stage HCC was analyzed. Results A total of 64 528 patients from 4 hospitals underwent miR7 testing, and 1 682 were finally included, of which 1 073 were diagnosed with very early-stage HCC and 609 were diagnosed with non-HCC. The positive rate of miR7 in HCC patients was significantly higher than that in non-HCC patients (67.9% vs 24.3%, P<0.001). ROC curves showed that the AUCs for miR7, AFP, and DCP in distinguishing HCC patients from the non-HCC individuals were 0.718, 0.682, and 0.642, respectively. The sensitivities were 67.85%, 43.71%, and 44.45%, and the specificities were 75.70%, 92.78%, and 83.91%, respectively. The pairwise comparison of AUCs showed that the diagnostic efficacy of plasma miR7 detection was significantly better than that of AFP or DCP (P<0.05). Although its specificity was slightly lower than AFP and DCP, the sensitivity was significantly higher. Among patients negative for both AFP and DCP, miR7 maintained an AUC of 0.728 for diagnosing very early-stage HCC, with 67.82% sensitivity and 77.73% specificity. Conclusions Plasma miR7 testing is a potential molecular marker with high sensitivity and specificity for the differential diagnosis of small hepatic nodules. In patients with very early-stage HCC lacking effective molecular markers (negative for both AFP and DCP), miR7 can serve as a novel and effective molecular marker to assist diagnosis.
2.Research on the feasibility of dynamic contrast-enhanced magnetic resonance imaging in assessing the microcirculatory perfusion of skeletal muscle in rabbit limbs in the early stage after high-voltage electric burns
Peng RUAN ; Siqin SUN ; Yinghong GE ; Yunfei ZHA
Chinese Journal of Burns 2025;41(2):163-170
Objective:To explore the feasibility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in assessing the microcirculatory perfusion of skeletal muscle in rabbit limbs in the early stage after high-voltage electric burns.Methods:This study was an experimental study. Thirty-two male big ear white rabbits aged 6-8 months were assigned into electric burn group of 20 rabbits with high-voltage electric burns in the right lower limb and control group of 12 rabbits with sham injury in the right lower limb using the random number table method. At 0.5, 24.0, 48.0, and 72.0 h post injury, the lower limbs of rabbits in the two groups underwent axial fast spin echo T1-weighted imaging, fast spin echo T2-weighted imaging, and DCE-MRI examination. A reference region-based hemodynamic model was applied to obtain the blood perfusion parameters of skeletal muscle in the injured limbs, including the volume transfer constant K trans value and rate constant K ep value. The skeletal muscle tissue from the electric burn group of rabbits at 0.5, 24.0, 48.0, and 72.0 h post injury and the control group of rabbits at 0.5 h post injury was harvested for immunohistochemical staining to observe the microvascular changes and calculate the microvascular density (MVD). The correlation between the K trans and K ep values and the MVD of skeletal muscle tissue in electric burn group of rabbits at 0.5-72.0 h post injury was analyzed. The number of samples was 5 in the electric burn group, and the number of samples was 3 in the control burn group. Results:From 0.5-72.0 h post injury, the K trans and K ep values in skeletal muscle tissue of electric burn group of rabbits exhibited the trends of increase first and decrease then, both of which reached peak values at 24.0 h post injury. The K trans values at 0.5, 24.0, 48.0, and 72.0 h post injury (with t values of -15.77, -14.91, -40.35, and -40.25, respectively, P<0.05) and the K ep values at 0.5, 24.0, and 48.0 h post injury (with t values of -5.39, -6.82, and -6.83, respectively, P<0.05) in skeletal muscle tissue in electric burn group of rabbits were significantly higher than those in control group. The MVD in skeletal muscle tissue in control group of rabbits at 0.5 h post injury and in electric burn group of rabbits at 0.5, 24.0, 48.0, and 72.0 h post injury was (24.7±3.5), (21.8±2.2), (40.8±9.1), (16.4±2.4), and (9.8±0.8) per mm2, respectively. The MVD in skeletal muscle tissue in electric burn group of rabbits at 24.0 h post injury was significantly higher than that in control group at 0.5 h post injury ( t=2.89, P<0.05), and the MVD in skeletal muscle tissue at 48.0 and 72.0 h post injury was significantly lower than that in control group at 0.5 h post injury (with t values of 4.01 and 9.52, respectively, P<0.05). The K trans and K ep values of skeletal muscle tissue in rabbits in electric burn group were significantly positively correlated with microvascular density at 0.5 to 72.0 h post injury (with both r values of 0.95, P<0.05). Conclusions:The quantitative perfusion parameters K trans and K ep values of DCE-MRI can effectively reflect the microcirculatory perfusion changes of skeletal muscle in rabbit limbs in the early stage after high-voltage electric burns.
3.Construction of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) based on the Delphi method
Shixiang GAO ; Zhijian SUN ; Changrun LI ; Dongchen YAO ; Han FEI ; Zhelun TAN ; Xiang YU ; Yinghong MA ; Shiyu ZHU ; Ting LI
Chinese Journal of Orthopaedic Trauma 2025;27(8):709-714
Objective:To report construction of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) using the Delphi method.Methods:Literature related to the study of adult distal radius fractures was fully searched for and evaluated. An expert group was established from representative experts from all over the nation. The related clinical issues were established by consulting the experts in the form of electronic questionnaires, strictly following the Delphi research method. After the first draft of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) was written, an expert consultation questionnaire was designed for the recommendation opinions to determine the recommendation strength.Results:The clinical issues were determined by 2 rounds of correspondence based on the Delphi method. For the both rounds of correspondence, the questionnaire recovery rates were respectively 88.68% (47/53) and 98.11% (52/53), and the expert authority coefficients >0.7. According to the screening criteria based on the importance of clinical issues (mean importance score <3.5 points or a coefficient of variation ≥0.25 points and a full score ratio <30%) and expert opinions, a total of 40 clinical issues were deleted in the first round of determination of clinical issues, and a total of 5 clinical issues deleted in the second round of determination of clinical issues. The reliability analysis of the results of the 2 rounds of questionnaires showed that the Cronbach α coefficient was >0.9. In the questionnaire to determine the recommendation strength, according to the screening criteria for the consistency of recommendation strength (consistency ≥ 70%) and expert opinions, a total of 26 recommendations were screened in the first round. In the second round when the remaining 4 recommendations were investigated, one recommendation reached the consistency of recommendation strength ≥ 70%. Eventually, 27 recommendations were formed.Conclusion:The Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) constructed using the Delphi method shows good scientific validity, authority, and reliability, providing methodological references for guideline development and research.
4.Analysis of change trend of hepatectomy for 17 232 cases of hepatocellular carcinoma and efficacy of fluorescent laparoscopic hepatectomy: a 10-year single center study
Kai ZHU ; Qiang GAO ; Xiaoying WANG ; Zhenbin DING ; Yinghong SHI ; Qinghai YE ; Huichuan SUN ; Shuangjian QIU ; Jian ZHOU ; Jia FAN
Chinese Journal of Digestive Surgery 2025;24(4):507-514
Objective:To investigate the change trend of hepatectomy for hepatocellular carcinoma and efficacy of fluorescent laparoscopic hepatectomy in a single center from 2014?2023.Methods:The propensity score matching and retrospective cohort study was conducted. The clinicopathological data of 17 232 patients of hepatocellular carcinoma who were admitted to Zhongshan Hospital of Fudan University from January 2014 to December 2023 were collected. There were 14 404 males and 2 828 females, aged 58(range, 11?94)years. Observation indicators: (1) change trend of hepatectomy for hepatocellular carcinoma and application of fluorescent laparoscopy in 2014?2023; (2) propensity score matching between patients undergoing fluorescent and conventional laparoscopic hepatectomy; (3) intraoperative and postoperative conditions of patients in the fluorescent laparoscopy group and the conventional laparoscopy group after propensity score matching. Comparison of measurement data with skewed distribution between groups was conducted using the Mann-Whitney U test. Comparison of count data between groups was conducted using the chi-square test. Comparison of ordinal data between groups was conducted using the nonparametic rank sum test. Propensity score matching was performed using the 1∶3 nearest neighbor matching method, with the caliper value of 0.01. Results:(1) Change trend of hepatectomy for hepatocellular carcinoma and application of fluorescent laparoscopy in 2014-2023. Among 17 232 patients of hepatocellular carcinoma, 4 074 cases underwent laparoscopic surgery, and 13 158 cases underwent open surgery or conversion from laparoscopic to open surgery. From 2014 to 2023, the proportions of laparos-copic surgery in hepatectomy were 8.993%(117/1 301), 6.804%(99/1 455), 9.379%(145/1 546), 17.511%(287/1 639), 23.828%(427/1 792), 24.572%(459/1 868), 29.662%(544/1 834), 31.568%(584/1 850), 38.080%(599/1 573), and 34.246%(813/2 374), respectively. The proportions of Grade Ⅲ surgery in laparoscopic hepatectomy were 11.966%(14/117), 7.071%(7/99), 12.414%(18/145), 21.254%(61/287), 28.337%(121/427), 27.887%(128/459), 34.375%(187/544), 34.644%(214/584), 35.726%(214/599), and 42.681%(347/813), respectively. From 2016 to 2023, the proportions of the application of fluorescent laparoscopy in laparoscopic hepatectomy were 2.069%(3/145), 5.923%(17/287), 8.431%(36/427), 10.022%(46/459), 17.647%(96/544), 24.829%(145/584), 9.182%(55/599), and 12.915%(105/813), respectively. (2) Propensity score matching between patients undergoing fluorescent and conventional laparoscopic hepatectomy. Among the 4 074 patients who underwent laparoscopic liver resection, 503 cases using fluorescent laparoscopy were assigned to the fluorescent laparoscopy group, 3 571 cases using conventional laparoscopy were assigned to the conventional laparoscopy group. A total of 1 794 patients were successfully matched, with 483 cases in the fluorescent laparoscopy group and 1 311 cases in the conventional laparoscopy group. After propensity score matching, the confounding biases of the maximum tumor diameter and the year of surgery were eliminated, and the two groups were comparable. (3) Intraoperative and postoperative conditions of patients in the fluorescent laparoscopy group and the conventional laparoscopy group after propensity score matching. After propensity score matching, there was no perioperative death in either the fluorescent laparoscopy group or the conventional laparoscopy group.The operation time of patients in the fluorescent laparoscopy group was 240(150,328)minutes, the portal triad clamping time was 30(15,45)minutes, the volume of intraoperative blood loss was 50(30,100)mL, the number of patients with complication 72, respectively. For patients in the conventional laparoscopy group, the above indicators were 180(131,240)minutes, 23(15,30)minutes, 55(50,100)mL, and 248, respectively. There were significant differences in the above indicators between the two groups ( Z=?7.593, ?7.372, ?4.941, χ2=3.873, P<0.05). Conclusion:The proportion and difficulty level of laparoscopic hepatectomy for hepatocellular carcinoma in Zhongshan Hospital of Fudan University have shown an upward trend during 2014?2023. Compared with conventional laparoscopy, patients undergoing fluorescent laparoscopic hepatectomy have longer operation time and portal triad clamping time, but less intraoperative blood loss and lower iproportion of complications.
5.Quality Evaluation on Xuanmai Ganjie Preparation Based on National Drug Sampling and Testing
Jingyun LI ; Liang HU ; Jiangnan LUO ; Yinghong WANG ; Xunyou TANG ; Sheng LIANG ; Liqin ZHAN ; Jingkai ZENG ; Yan LUO ; Hui SUN ; Ye DING ; Wenli LI ; Jialiang ZHU
Herald of Medicine 2025;44(10):1606-1611
Objective Based on the national drug sampling inspection program,this study aims to comprehensively and systematically evaluate the quality of Xuanmai Ganjie preparations,analyze existing quality issues,and provide references and suggestions for quality control of this variety.Methods A total of 237 batches of Xuanmai Ganjie preparations were tested using legal standards,and methods were established for detecting adulteration of Ophiopogon japonicus with counterfeit varieties,paclobutrazol residue levels,and determining the content of platycodin D in Xuanmai Ganjie preparations.These methods were applied to the quality control and evaluation of Xuanmai Ganjie preparations.Results Through statutory inspection,one batch of Xuanmai Ganjie granules was found non-compliant.Specific batches were identified to contain the following irregularities:adulteration of Ophiopogon japonicus with counterfeit varieties,paclobutrazol residue levels exceeding proposed limits,and platycodin D content below the established threshold.Conclusion The overall quality of Xuanmai Ganjie granules was average,while the overall quality of Xuanmai Ganjie capsules and lozenges was relatively good.Manufacturing enterprises should strengthen their sense of primary responsibility and enhance control over the entire drug production process.
6.Analysis of change trend of hepatectomy for 17 232 cases of hepatocellular carcinoma and efficacy of fluorescent laparoscopic hepatectomy: a 10-year single center study
Kai ZHU ; Qiang GAO ; Xiaoying WANG ; Zhenbin DING ; Yinghong SHI ; Qinghai YE ; Huichuan SUN ; Shuangjian QIU ; Jian ZHOU ; Jia FAN
Chinese Journal of Digestive Surgery 2025;24(4):507-514
Objective:To investigate the change trend of hepatectomy for hepatocellular carcinoma and efficacy of fluorescent laparoscopic hepatectomy in a single center from 2014?2023.Methods:The propensity score matching and retrospective cohort study was conducted. The clinicopathological data of 17 232 patients of hepatocellular carcinoma who were admitted to Zhongshan Hospital of Fudan University from January 2014 to December 2023 were collected. There were 14 404 males and 2 828 females, aged 58(range, 11?94)years. Observation indicators: (1) change trend of hepatectomy for hepatocellular carcinoma and application of fluorescent laparoscopy in 2014?2023; (2) propensity score matching between patients undergoing fluorescent and conventional laparoscopic hepatectomy; (3) intraoperative and postoperative conditions of patients in the fluorescent laparoscopy group and the conventional laparoscopy group after propensity score matching. Comparison of measurement data with skewed distribution between groups was conducted using the Mann-Whitney U test. Comparison of count data between groups was conducted using the chi-square test. Comparison of ordinal data between groups was conducted using the nonparametic rank sum test. Propensity score matching was performed using the 1∶3 nearest neighbor matching method, with the caliper value of 0.01. Results:(1) Change trend of hepatectomy for hepatocellular carcinoma and application of fluorescent laparoscopy in 2014-2023. Among 17 232 patients of hepatocellular carcinoma, 4 074 cases underwent laparoscopic surgery, and 13 158 cases underwent open surgery or conversion from laparoscopic to open surgery. From 2014 to 2023, the proportions of laparos-copic surgery in hepatectomy were 8.993%(117/1 301), 6.804%(99/1 455), 9.379%(145/1 546), 17.511%(287/1 639), 23.828%(427/1 792), 24.572%(459/1 868), 29.662%(544/1 834), 31.568%(584/1 850), 38.080%(599/1 573), and 34.246%(813/2 374), respectively. The proportions of Grade Ⅲ surgery in laparoscopic hepatectomy were 11.966%(14/117), 7.071%(7/99), 12.414%(18/145), 21.254%(61/287), 28.337%(121/427), 27.887%(128/459), 34.375%(187/544), 34.644%(214/584), 35.726%(214/599), and 42.681%(347/813), respectively. From 2016 to 2023, the proportions of the application of fluorescent laparoscopy in laparoscopic hepatectomy were 2.069%(3/145), 5.923%(17/287), 8.431%(36/427), 10.022%(46/459), 17.647%(96/544), 24.829%(145/584), 9.182%(55/599), and 12.915%(105/813), respectively. (2) Propensity score matching between patients undergoing fluorescent and conventional laparoscopic hepatectomy. Among the 4 074 patients who underwent laparoscopic liver resection, 503 cases using fluorescent laparoscopy were assigned to the fluorescent laparoscopy group, 3 571 cases using conventional laparoscopy were assigned to the conventional laparoscopy group. A total of 1 794 patients were successfully matched, with 483 cases in the fluorescent laparoscopy group and 1 311 cases in the conventional laparoscopy group. After propensity score matching, the confounding biases of the maximum tumor diameter and the year of surgery were eliminated, and the two groups were comparable. (3) Intraoperative and postoperative conditions of patients in the fluorescent laparoscopy group and the conventional laparoscopy group after propensity score matching. After propensity score matching, there was no perioperative death in either the fluorescent laparoscopy group or the conventional laparoscopy group.The operation time of patients in the fluorescent laparoscopy group was 240(150,328)minutes, the portal triad clamping time was 30(15,45)minutes, the volume of intraoperative blood loss was 50(30,100)mL, the number of patients with complication 72, respectively. For patients in the conventional laparoscopy group, the above indicators were 180(131,240)minutes, 23(15,30)minutes, 55(50,100)mL, and 248, respectively. There were significant differences in the above indicators between the two groups ( Z=?7.593, ?7.372, ?4.941, χ2=3.873, P<0.05). Conclusion:The proportion and difficulty level of laparoscopic hepatectomy for hepatocellular carcinoma in Zhongshan Hospital of Fudan University have shown an upward trend during 2014?2023. Compared with conventional laparoscopy, patients undergoing fluorescent laparoscopic hepatectomy have longer operation time and portal triad clamping time, but less intraoperative blood loss and lower iproportion of complications.
7.Quality Evaluation on Xuanmai Ganjie Preparation Based on National Drug Sampling and Testing
Jingyun LI ; Liang HU ; Jiangnan LUO ; Yinghong WANG ; Xunyou TANG ; Sheng LIANG ; Liqin ZHAN ; Jingkai ZENG ; Yan LUO ; Hui SUN ; Ye DING ; Wenli LI ; Jialiang ZHU
Herald of Medicine 2025;44(10):1606-1611
Objective Based on the national drug sampling inspection program,this study aims to comprehensively and systematically evaluate the quality of Xuanmai Ganjie preparations,analyze existing quality issues,and provide references and suggestions for quality control of this variety.Methods A total of 237 batches of Xuanmai Ganjie preparations were tested using legal standards,and methods were established for detecting adulteration of Ophiopogon japonicus with counterfeit varieties,paclobutrazol residue levels,and determining the content of platycodin D in Xuanmai Ganjie preparations.These methods were applied to the quality control and evaluation of Xuanmai Ganjie preparations.Results Through statutory inspection,one batch of Xuanmai Ganjie granules was found non-compliant.Specific batches were identified to contain the following irregularities:adulteration of Ophiopogon japonicus with counterfeit varieties,paclobutrazol residue levels exceeding proposed limits,and platycodin D content below the established threshold.Conclusion The overall quality of Xuanmai Ganjie granules was average,while the overall quality of Xuanmai Ganjie capsules and lozenges was relatively good.Manufacturing enterprises should strengthen their sense of primary responsibility and enhance control over the entire drug production process.
8.Construction of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) based on the Delphi method
Shixiang GAO ; Zhijian SUN ; Changrun LI ; Dongchen YAO ; Han FEI ; Zhelun TAN ; Xiang YU ; Yinghong MA ; Shiyu ZHU ; Ting LI
Chinese Journal of Orthopaedic Trauma 2025;27(8):709-714
Objective:To report construction of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) using the Delphi method.Methods:Literature related to the study of adult distal radius fractures was fully searched for and evaluated. An expert group was established from representative experts from all over the nation. The related clinical issues were established by consulting the experts in the form of electronic questionnaires, strictly following the Delphi research method. After the first draft of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) was written, an expert consultation questionnaire was designed for the recommendation opinions to determine the recommendation strength.Results:The clinical issues were determined by 2 rounds of correspondence based on the Delphi method. For the both rounds of correspondence, the questionnaire recovery rates were respectively 88.68% (47/53) and 98.11% (52/53), and the expert authority coefficients >0.7. According to the screening criteria based on the importance of clinical issues (mean importance score <3.5 points or a coefficient of variation ≥0.25 points and a full score ratio <30%) and expert opinions, a total of 40 clinical issues were deleted in the first round of determination of clinical issues, and a total of 5 clinical issues deleted in the second round of determination of clinical issues. The reliability analysis of the results of the 2 rounds of questionnaires showed that the Cronbach α coefficient was >0.9. In the questionnaire to determine the recommendation strength, according to the screening criteria for the consistency of recommendation strength (consistency ≥ 70%) and expert opinions, a total of 26 recommendations were screened in the first round. In the second round when the remaining 4 recommendations were investigated, one recommendation reached the consistency of recommendation strength ≥ 70%. Eventually, 27 recommendations were formed.Conclusion:The Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) constructed using the Delphi method shows good scientific validity, authority, and reliability, providing methodological references for guideline development and research.
9.Research on the feasibility of dynamic contrast-enhanced magnetic resonance imaging in assessing the microcirculatory perfusion of skeletal muscle in rabbit limbs in the early stage after high-voltage electric burns
Peng RUAN ; Siqin SUN ; Yinghong GE ; Yunfei ZHA
Chinese Journal of Burns 2025;41(2):163-170
Objective:To explore the feasibility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in assessing the microcirculatory perfusion of skeletal muscle in rabbit limbs in the early stage after high-voltage electric burns.Methods:This study was an experimental study. Thirty-two male big ear white rabbits aged 6-8 months were assigned into electric burn group of 20 rabbits with high-voltage electric burns in the right lower limb and control group of 12 rabbits with sham injury in the right lower limb using the random number table method. At 0.5, 24.0, 48.0, and 72.0 h post injury, the lower limbs of rabbits in the two groups underwent axial fast spin echo T1-weighted imaging, fast spin echo T2-weighted imaging, and DCE-MRI examination. A reference region-based hemodynamic model was applied to obtain the blood perfusion parameters of skeletal muscle in the injured limbs, including the volume transfer constant K trans value and rate constant K ep value. The skeletal muscle tissue from the electric burn group of rabbits at 0.5, 24.0, 48.0, and 72.0 h post injury and the control group of rabbits at 0.5 h post injury was harvested for immunohistochemical staining to observe the microvascular changes and calculate the microvascular density (MVD). The correlation between the K trans and K ep values and the MVD of skeletal muscle tissue in electric burn group of rabbits at 0.5-72.0 h post injury was analyzed. The number of samples was 5 in the electric burn group, and the number of samples was 3 in the control burn group. Results:From 0.5-72.0 h post injury, the K trans and K ep values in skeletal muscle tissue of electric burn group of rabbits exhibited the trends of increase first and decrease then, both of which reached peak values at 24.0 h post injury. The K trans values at 0.5, 24.0, 48.0, and 72.0 h post injury (with t values of -15.77, -14.91, -40.35, and -40.25, respectively, P<0.05) and the K ep values at 0.5, 24.0, and 48.0 h post injury (with t values of -5.39, -6.82, and -6.83, respectively, P<0.05) in skeletal muscle tissue in electric burn group of rabbits were significantly higher than those in control group. The MVD in skeletal muscle tissue in control group of rabbits at 0.5 h post injury and in electric burn group of rabbits at 0.5, 24.0, 48.0, and 72.0 h post injury was (24.7±3.5), (21.8±2.2), (40.8±9.1), (16.4±2.4), and (9.8±0.8) per mm2, respectively. The MVD in skeletal muscle tissue in electric burn group of rabbits at 24.0 h post injury was significantly higher than that in control group at 0.5 h post injury ( t=2.89, P<0.05), and the MVD in skeletal muscle tissue at 48.0 and 72.0 h post injury was significantly lower than that in control group at 0.5 h post injury (with t values of 4.01 and 9.52, respectively, P<0.05). The K trans and K ep values of skeletal muscle tissue in rabbits in electric burn group were significantly positively correlated with microvascular density at 0.5 to 72.0 h post injury (with both r values of 0.95, P<0.05). Conclusions:The quantitative perfusion parameters K trans and K ep values of DCE-MRI can effectively reflect the microcirculatory perfusion changes of skeletal muscle in rabbit limbs in the early stage after high-voltage electric burns.
10.Research progress on targeted activation of Nrf2 pathway and treatment of diabetic kidney disease
Dandan CHEN ; Lin AI ; Lingli ZHOU ; Yinghong SUN ; Dandan HAO
Chinese Journal of Diabetes 2024;32(11):876-880
Diabetic kidney disease(DKD)is not only the main microvascular complication of diabetes mellitus,but also a common cause of end stage renal disease.Oxidative stress and nuclear factor E2-related factor 2(Nrf2)/kelch like epichlorohydrin related protein 1/antioxidant response element pathway damage may be involved in the occurrence and development of DKD.This article reviews the research progress of targeted activation of Nrf2 pathway and DKD treatment.

Result Analysis
Print
Save
E-mail