1.Preliminary application of histological evaluation of donor pancreas biopsy tissue in simultaneous pancreas-kidney transplantation
Jiao WAN ; Hui GUO ; Jiali FANG ; Guanghui LI ; Luhao LIU ; Yunyi XIONG ; Wei YIN ; Tong YANG ; Junjie MA ; Zheng CHEN
Organ Transplantation 2026;17(2):250-256
Objective To preliminarily investigate the safety and efficacy of donor pancreas needle biopsy in simultaneous pancreas-kidney transplantation. Methods Clinical data of 7 cases undergoing donor pancreas biopsy were collected retrospectively. All cases underwent donor pancreas biopsy before or during simultaneous pancreas-kidney transplantation. Frozen section or paraffin sectioning techniques were used for tissue preparation, and hematoxylin-eosin and Masson staining were performed to histologically evaluate the donor pancreas. The quality of donor pancreas was comprehensively assessed by combining histological findings with the donor's clinical data. Postoperative follow-up data of 5 simultaneous pancreas-kidney transplant recipients were collected to summarize the safety of donor pancreas biopsy and the prognosis of transplant recipients. Results The 7 pancreas donors were aged 28 to 62 years, with a body mass index ranging from 20.76 to 27.68 kg/m2. Liver ultrasound indicated fatty liver in 3 cases, while pancreatic ultrasound did not reveal any significant abnormalities. Among them, biopsy was performed on 2 donors after completion of pancreatic procurement and processing, and the frozen section histology showed moderate acute pancreatitis changes (edema of acinar cells, necrosis and inflammatory cell infiltration). Combined with a serum amylase level elevated more than 3 times the upper limit of normal value, these two donor pancreases were finally discarded. The remaining 5 cases underwent biopsy immediately after pancreatic vascular anastomosis during simultaneous pancreas-kidney transplantation, and histological evaluation was performed on paraffin-embedded sections. No biopsy-related complications (such as bleeding, pancreatic fistula, etc.) occurred after transplantation. One recipient died of severe infection 2 months after transplantation, while the other 4 recipients were followed up for more than 5 years, with well-functioning transplant kidneys and pancreases. Conclusions Donor pancreas biopsy is relatively safe, and the risk of biopsy-related complications after transplantation is controllable. Comprehensive assessment of donor pancreas quality by combining histological evaluation with the donor's clinical indicators is conducive to improving the accuracy of donor pancreas selection and organ utilization.
2.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
3.Population composition and seasonal distribution of mosquitoes in Laoshan District, Qingdao City
Zi-long TANG ; Na YU ; Yang YU ; Fan YIN ; Bing-hui LI ; Hong-yu WANG ; Ke-jia HUANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):114-120
Objective The study aimed to elucidate the population composition and seasonal distribution characteristics of mosquitoes in Laoshan District, Qingdao City, providing a scientific basis for the prevention and control of mosquito-borne infectious diseases. Methods Mosquito surveillance was conducted in Laoshan District in Qingdao City using light traps from April to November 2020-2022. Dominant mosquito species were identified using the Berger-Parker dominance index(I)and mosquito density was compared using the Kruskal-Wallis H test. The seasonal distribution characteristics of adult mosquitoes were analyzed using concentration and circular distribution method. Spearman rank correlation analysis was used to study the relationship between mosquito populations and meteorological factors with mean monthly temperature, mean monthly relative humidity, and mean monthly rainfall. Results The mean mosquito density for the trapping period was 9.771 females/(trap·night)in 2020,9.771 in 2021, and 9.427 in 2022. There was no statistically significant difference in mosquito density between different years(H = 0.095, P = 0.954). In total, 2 781 adult female mosquitoes comprising five species from four genera were captured over three years. Culex pipiens(I = 0.654), Aedes albopictus(I = 0.202), and Aedes aegypti(I = 0.118)were identified as dominant species. Seasonal fluctuations in the adult mosquitoes were unimodal, and primarily concentrated from June to September. The peak period of adult mosquito varied between years with statistical significance. (F = 3.838, P < 0.05). Mosquito density was highly correlated with mean monthly temperature, mean monthly relative humidity and mean monthly precipitation(P< 0.05). Conclusions Cx. pipiens pallens, Ae. albopictus, and Ar. inamoratus are the dominant mosquito species in the Laoshan District of Qingdao City. The activity of adult mosquitoes is seasonal, and primarily concentrated in summer and autumn, during which the risk of mosquito-borne diseases such as dengue fever is increased.
4.Automatic Measurement Method for Spatial Resolution of MRI Based on the ACR Phantom
Yu ZHANG ; Hongxia YIN ; Yawen LIU ; Pengling REN ; Yanjun HU ; Tianxin CHENG ; Zhenghan YANG ; Zhenchang WANG ; Hui XU
Chinese Journal of Medical Imaging 2025;33(6):595-600,606
Purpose To measure the spatial resolution in MRI quality control testing automatically based on the American College of Radiology(ACR)phantom using the support vector machine(SVM)method,and the feasibility,accuracy and measurement speed of this method are explored.Materials and Methods Quality control tests were performed using eight MRI devices at Beijing Friendship Hospital of Capital Medical University.A retrospective study was conducted on 71 MRI quality control test images collected based on ACR phantoms between 2017 and 2019.The images were preprocessed by binarization,extraction region of interest and so on.An SVM-based classification model was constructed for analyzing the spatial resolution of dot arrays in row and column directions.The dataset was randomly split into a training set and a test set.The generalization performance of the classification model in this study was evaluated through accuracy,precision,recall and F1 score on the test set.Comparing the results of spatial resolution measurements obtained by both manual and automatic method,we demonstrated the feasibility and accuracy of the method.Additionally,the time taken for the automatic spatial resolution measurement was recorded.Results In this study,the proposed method of automatically measuring the spatial resolution of ACR phantom test images using SVM was feasible,high accuracy and short time.In classification performance test,the accuracy of the spatial resolution of the row directional latices was 95%,the precision was 100%.The accuracy of the spatial resolution of the column directional latices was 97%,the precision was 100%.Among the test cases,the results of automatic measurements matched those of manual measurements in 13 out of 14 cases.On average,automatic spatial resolution measurement took 0.158 seconds per case.Conclusion This study achieves automatic measurement of spatial resolution in MRI quality control based on the ACR phantom using SVM method.The method demonstrates high accuracy and fast measurement speeds,holding significant implications for future rapid MRI quality control stability testing.
5.Automatic Detection of Quality Control Performance of Radio Frequency Coils Based on ACR Phantom
Yawen LIU ; Hongxia YIN ; Yu ZHANG ; Pengling REN ; Yanjun HU ; Hui XU ; Zhenghan YANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):601-606
Purpose To explore an automatic detection method for quality control performance indicators of radio frequency coils based on American College of Radiology(ACR)phantom,and verify its accuracy stability and computational efficiency.Materials and Methods A retrospective study was conducted on 50 quality control images collected based on ACR phantom in Beijing Friendship Hospital,Capital Medical University from May 2017 to July 2019.The measurement and calculation methods of signal noise ratio(SNR),percent image uniformity(PIU)and percent signal ghosting(PSG)were used to automatically calculate the above indicators using a self-designed program in Python.A simple linear regression analysis on the automatically calculated SNR,PSG and PIU values compared to the manually measured results was performed,and Bland-Altman analysis was used to calculate the percentage difference to evaluate the consistency and bias between the performance indicators calculated by the two methods.The time consumption of two detection methods was compared to verify their computational complexity and efficiency.Results There was a strong correlation between the performance indicators SNR,PSG and PIU of radio frequency coils measured and calculated automatically and manually(r=0.991 4,0.992 8 and 0.909 8,all P<0.0001).The Bland-Altman results showed that most of the data fall within the 95%confidence interval and were evenly distributed.In terms of computational complexity and efficiency,compared to the complex manual delineation and calculation of 2-3 minutes per case,automatic detection could simultaneously obtain SNR,PSG and PIU values in less than 1 second.Conclusion The automatic and manual measurement methods have good consistency,and the automatic detection method is easy to operate,which is helpful for the daily quality control work and performance monitoring of radio frequency coils.
6.Association between dynamic indexes of maternal progesterone in the first trimester of pregnancy and fetal head circumference growth and development
Hui NIU ; Juan XIN ; Jinlu LIANG ; Jiayuan FENG ; Sijing ZHU ; Xiaoxue LI ; Yin YANG ; Liu FANG ; Mengfei SUN ; Ziyi CHEN ; Wenfang YANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(5):871-879
Objective To explore the association between dynamic indexes of maternal progesterone in early pregnancy and the average level and growth rate of fetal head circumference(HC)in mid-and late pregnancy.Methods This study adopted a retrospective cohort design and included 255 singleton pregnant women in the maternal and infant cohort of The First Affiliated Hospital of Xi'an Jiaotong University from January 2015 to December 2024.The progesterone levels of their early venous blood were detected and divided into two groups of progesterone trajectories,namely,fluctuating type and increasing type,by morphology.The dynamic indicators of progesterone in early pregnancy were constructed:cumulative dynamic deviation index in the first trimester(CDDI-P1T),gestational age at progesterone peak(GA-PP),and maximal relative progesterone decline in the first trimester(MRD-P1T).The average head circumference level and linear growth rate of the fetuses in the middle and late pregnancy were calculated.Generalized linear regression(GLM)was used to analyze the linear association between progesterone dynamic indicators and head circumference development.The key gestational weeks of progesterone affecting fetal head development were explored by linear regression of gestational weeks.Ordinary least squares(OLS)regression and restricted cubic spline(RCS)plots were used to draw the nonlinear association between progesterone dynamic indicators and head circumference.Results Among the 255 pregnant women included,92.5%of the progesterone trajectories in early pregnancy were fluctuating,and 7.5%were increasing.The growth rates of the increasing progesterone trajectory group were higher in the second and third trimesters than in the fluctuating group,but the differences were not statistically significant(all P>0.05).GLM analysis showed that for every 1 unit increase in CDDI-P1T,the head circumference in the middle and late pregnancy increased significantly by 1.574 cm and 1.193 cm(Z=3.714,2.885,P<0.01).The delay of GA-PP was negatively correlated with the head circumference in the middle pregnancy(β=-0.190 cm,95%CI:-0.339--0.041,P=0.010)but positively correlated with the head circumference growth rate in the late pregnancy(β=0.022 cm/week,95%CI:0.003-0.041,P=0.025).A 10%decrease in the decline of CDDI-P1T increased the head circumference in the middle pregnancy by 0.200 cm(95%CI:0.016-0.384,P=0.033),and a 100%decrease in the decline increased the head circumference growth rate in the late pregnancy by 0.201 cm/week(95%CI:0.002-0.399,P=0.048).The analysis of the key time window showed that for every 20 nmol/L increase in progesterone during 9.5-13 weeks of pregnancy,the mid-term head circumference increased by 0.035-0.166 cm(Z=2.452-3.517,allP<0.05),and the late-term head circumference increased by 0.767 cm during 9-13 weeks of pregnancy(Z=2.452-3.517,all P<0.05).When progesterone increased during 9.5-10.5 weeks of pregnancy,the growth rate of mid-term head circumference increased by 0.013-0.023 cm/week(Z=2.074-2.243,all P<0.01).When progesterone increased during 8.5-10.5 weeks of pregnancy,the growth rate of late-term head circumference increased by 0.010-0.026 cm/week(Z=2.061-3.137,all P<0.05).Conclusion Progesterone dynamic index is a new sensitive tool for evaluating fetal head circumference development.There is a stage-specific window period for progesterone regulation.9.5-13 weeks of pregnancy is the critical period for progesterone to affect head circumference growth,and 9.5-10.5 weeks of pregnancy is the core window for regulating the growth rate of head circumference.Therefore,it is necessary to combine progesterone dynamic index and time window for individualized intervention to promote the transformation of prenatal care from pregnancy maintenance to eugenics intervention.
7.Development of a knowledge-attitude-practice assessment scale for home prevention and management of parastostomy hernia in ostomy patients and the test of its reliability and validity
Yajing ZHANG ; Hui ZHU ; Hong YIN ; Yu LONG ; Yang LI ; Qiaomei ZHANG ; Hongwen MA
Chinese Journal of Nursing 2025;60(4):411-417
Objective To develop a knowledge-attitude-practice assessment scale for home prevention and man-agement of parastostomy hernia in ostomy patients,and to test its reliability and validity,to provide a reliable tool for evaluating the knowledge and practice level of home prevention and management of parastostomy hernia in pa-tients with ostomy.Methods Based on the theory of knowledge,attitude and practice,the initial scale was generat-ed through literature review,semi-structured interviews,expert correspondence,research group discussion and pre-sur-vey.From May to December 2023,685 patients with ostomy from the ostomy clinic of a tertiary hospital in Tianjin were investigated by purpose sampling method,and the reliability and validity were tested.Results A total of 673 valid questionnaires were collected,the results showed that the knowledge-attitude-practice assessment scale for pre-venting and managing parastomal hernia of ostomy patients at home included 3 dimensions of knowledge,attitude and practice,with a total of 27 items.The response rates of 2 rounds of the questionnaire were both 100%;the au-thority coefficients were all 0.915;the Kendall's coefficients of concordance were 0.279 and 0.301,respectively.The content validity index of each item was 0.875~1.000;the content validity index of the average scale level was 0.988;after 2 exploratory factor analysis,the cumulative variance contribution rate was 65.920%.The results of con-firmatory factor analysis showed that the model had a good fit,with a chi-square degree of freedom ratio(/df)of 1.945,the fitting goodness index(GFI)of 0.851,the comparative goodness of fit index(CFI)of 0.919,the root means square error of approximation(RMSEA)of 0.060.The Cronbach's alpha coefficient result of the scale is 0.957,with a test-retest reliability of 0.826 and a half reliability of 0.934.Conclusion The knowledge-attitude-practice assessment scale has good reliability and validity,and can be used as an assessment tool for home prevention and management of parastostomy hernia in ostomy patients.
8.Correlation between white matter microstructural changes and clinical function in patient with relapsing-remitting multiple sclerosis
Yan ZHANG ; Yi YIN ; Liming YANG ; Mingming HUANG ; Hui YU
Journal of Practical Radiology 2025;41(1):9-12,57
Objective To investigate the microstructural changes of white matter in patients with relapsing-remitting multiple sclerosis(RRMS)and its correlation with clinical functional scores.Methods A total of 20 patients with RRMS(RRMS group)and 20 healthy controls(HC)(HC group)were selected and underwent diffusion tensor imaging(DTI)and expanded disability status scale(EDSS)scores.Patients with RRMS were categorized into two groups based on their EDSS scores,including MS-1 group(motor dysfunction with visual impairment)and MS-2 group(motor dysfunction).Image processing was performed via tract-based spatial statistics(TBSS).Group comparisons were executed using the t-test,while correlations were analyzed utilizing Spearman correlation.Results In the RRMS group,reduced fractional anisotropy(FA)values were accompanied by increased mean diffusivity(MD)and radial diffusivity(RD)values in the forceps major,forceps minor,bilateral cingulum,bilateral uncinate fasciculus,bilateral superior longitudinal fasciculus,bilateral inferior longitudinal fasciculus,bilateral inferior fronto-occipital fasciculus,bilateral corticospinal tract and bilateral anterior thalamic radiation compared with the HC group.Additionally,In the RRMS group,increased axial diffusivity(AD)values were noted in the forceps major,forceps minor,bilateral superior longitudinal fasciculus(temporal),right inferior fronto-occipital fasciculus,bilateral corticospinal tract and right anterior thalamic radiation compared with the HC group.Compared with the MS-2 group,the MS-1 group exhibited higher FA values in the right cingulum(cingulate gyrus part)and higher AD values in the left cingulum(cingulate gyrus part).Correlation analysis revealed negative correlations between the FA values of the forceps major,right superior longitudinal fasciculus and the motor function scores in RRMS group.Conversely,positive correlations were identified between the MD values of the forceps minor,right superior longitudinal fasciculus,right inferior fronto-occipital fasciculus,left corticospinal tract and the RD values of the forceps minor,right cingulum(hip-pocampus),right superior longitudinal fasciculus,and left corticospinal tract,as well as the motor function scores.Conclusion RRMS patients exhibit microstructural damage in white matter and are associated with motor dysfunction,which provides imaging support for the pathological mechanisms underlying motor dysfunction in RRMS patients.
9.Development of a knowledge-attitude-practice assessment scale for home prevention and management of parastostomy hernia in ostomy patients and the test of its reliability and validity
Yajing ZHANG ; Hui ZHU ; Hong YIN ; Yu LONG ; Yang LI ; Qiaomei ZHANG ; Hongwen MA
Chinese Journal of Nursing 2025;60(4):411-417
Objective To develop a knowledge-attitude-practice assessment scale for home prevention and man-agement of parastostomy hernia in ostomy patients,and to test its reliability and validity,to provide a reliable tool for evaluating the knowledge and practice level of home prevention and management of parastostomy hernia in pa-tients with ostomy.Methods Based on the theory of knowledge,attitude and practice,the initial scale was generat-ed through literature review,semi-structured interviews,expert correspondence,research group discussion and pre-sur-vey.From May to December 2023,685 patients with ostomy from the ostomy clinic of a tertiary hospital in Tianjin were investigated by purpose sampling method,and the reliability and validity were tested.Results A total of 673 valid questionnaires were collected,the results showed that the knowledge-attitude-practice assessment scale for pre-venting and managing parastomal hernia of ostomy patients at home included 3 dimensions of knowledge,attitude and practice,with a total of 27 items.The response rates of 2 rounds of the questionnaire were both 100%;the au-thority coefficients were all 0.915;the Kendall's coefficients of concordance were 0.279 and 0.301,respectively.The content validity index of each item was 0.875~1.000;the content validity index of the average scale level was 0.988;after 2 exploratory factor analysis,the cumulative variance contribution rate was 65.920%.The results of con-firmatory factor analysis showed that the model had a good fit,with a chi-square degree of freedom ratio(/df)of 1.945,the fitting goodness index(GFI)of 0.851,the comparative goodness of fit index(CFI)of 0.919,the root means square error of approximation(RMSEA)of 0.060.The Cronbach's alpha coefficient result of the scale is 0.957,with a test-retest reliability of 0.826 and a half reliability of 0.934.Conclusion The knowledge-attitude-practice assessment scale has good reliability and validity,and can be used as an assessment tool for home prevention and management of parastostomy hernia in ostomy patients.
10.Identification of a Fetal De Novo Splice Variant in ARCN1 Associated With Growth and Skeletal Abnormalities
Wencong HE ; Zejun YANG ; Jianjian CUI ; Ruilin MA ; Hui TAO ; Yanan LI ; Yin ZHAO
Maternal-Fetal Medicine 2025;07(1):9-14
Objective::To report a fetus with ARCN1-related syndrome caused by a novel de novo heterozygous variant, highlighting the importance of early genetic diagnosis in prenatal care. Methods::The clinical and genetic data of a fetus with a complex combination of clinical signs and a novel de novo heterozygous variant were collected and have been summarized in this study. The potential pathogenic variant was identified throughout the whole exome sequencing and the effects of candidate variants were further validated by a minigene splicing assay. Results::Prenatal systematic ultrasound detected fetal growth restriction. Genetic analysis identified a novel de novo heterozygous variant within the ARCN1 gene—c.1241 +5G>A-located in intron 8. In vitro minigene splicing assays demonstrated that the variant led to two abnormal transcripts. The longer transcript retained 189 base pairs of intron 8, resulting in a truncated protein of 414 amino acids (p.Ser415*). The shorter transcript involved exon 8 skippings, producing a truncated protein of 407 amino acids (p.Ile378Serfs*31). Conclusion::A novel de novo heterozygous variant of the ARCN1 gene, namely NM_001655.5: c.1241 +5G>A, was discovered and identified in a fetus with rhizomelic short stature, microretrognathia, and developmental delays.


Result Analysis
Print
Save
E-mail