1.Preliminary application of histological evaluation of donor pancreas biopsy tissue in simultaneous pancreas-kidney transplantation
Jiao WAN ; Hui GUO ; Jiali FANG ; Guanghui LI ; Luhao LIU ; Yunyi XIONG ; Wei YIN ; Tong YANG ; Junjie MA ; Zheng CHEN
Organ Transplantation 2026;17(2):250-256
Objective To preliminarily investigate the safety and efficacy of donor pancreas needle biopsy in simultaneous pancreas-kidney transplantation. Methods Clinical data of 7 cases undergoing donor pancreas biopsy were collected retrospectively. All cases underwent donor pancreas biopsy before or during simultaneous pancreas-kidney transplantation. Frozen section or paraffin sectioning techniques were used for tissue preparation, and hematoxylin-eosin and Masson staining were performed to histologically evaluate the donor pancreas. The quality of donor pancreas was comprehensively assessed by combining histological findings with the donor's clinical data. Postoperative follow-up data of 5 simultaneous pancreas-kidney transplant recipients were collected to summarize the safety of donor pancreas biopsy and the prognosis of transplant recipients. Results The 7 pancreas donors were aged 28 to 62 years, with a body mass index ranging from 20.76 to 27.68 kg/m2. Liver ultrasound indicated fatty liver in 3 cases, while pancreatic ultrasound did not reveal any significant abnormalities. Among them, biopsy was performed on 2 donors after completion of pancreatic procurement and processing, and the frozen section histology showed moderate acute pancreatitis changes (edema of acinar cells, necrosis and inflammatory cell infiltration). Combined with a serum amylase level elevated more than 3 times the upper limit of normal value, these two donor pancreases were finally discarded. The remaining 5 cases underwent biopsy immediately after pancreatic vascular anastomosis during simultaneous pancreas-kidney transplantation, and histological evaluation was performed on paraffin-embedded sections. No biopsy-related complications (such as bleeding, pancreatic fistula, etc.) occurred after transplantation. One recipient died of severe infection 2 months after transplantation, while the other 4 recipients were followed up for more than 5 years, with well-functioning transplant kidneys and pancreases. Conclusions Donor pancreas biopsy is relatively safe, and the risk of biopsy-related complications after transplantation is controllable. Comprehensive assessment of donor pancreas quality by combining histological evaluation with the donor's clinical indicators is conducive to improving the accuracy of donor pancreas selection and organ utilization.
2.Flavonoids Intervene in Diabetic Nephropathy by Regulating TGF-β/Smad Signaling Pathway: A Review
Qihui QIU ; Chang LIU ; Xiaotong YAN ; Jinwei HAN ; Hui SUN ; Fengting YIN ; Yuhang WANG ; Mengmeng WANG ; Xijun WANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(7):300-309
Diabetic nephropathy (DKD), as a common microvascular complication of diabetes mellitus (DM), is a major cause of end-stage renal disease (ESRD). Its clinical manifestations include increased urinary protein excretion, thickening of the glomerular basement membrane, and renal tubulointerstitial fibrosis. The pathogenesis of DKD is complex and involves multiple factors, including disordered glucose metabolism, hemodynamic alterations, and oxidative stress. Although modern medical approaches can alleviate certain symptoms, they still have limitations such as insufficient therapeutic targeting and prominent adverse effects. The transforming growth factor-β/Smad (TGF-β/Smad) signaling pathway is not only a tissue fibrosis pathway that has attracted considerable attention in recent years, but also regulates multiple protein molecules, including the glomerular podocyte slit diaphragm protein Podocin, interleukin-1β (IL-1β), and superoxide dismutase (SOD), thereby participating in various pathological processes and ultimately mediating renal injury. Flavonoid compounds, owing to their sustained pharmacological effects, broad spectrum of action, and high safety profile, have become ideal candidates for targeted therapy research in DKD. Existing studies have shown that these compounds can exert inhibitory effects on renal fibrosis, alleviate inflammatory responses, protect podocytes, and reduce oxidative stress by regulating the interactions between the TGF-β/Smad signaling pathway and the aforementioned protein molecules, thereby maintaining renal structure and function, reducing proteinuria, and significantly improving DKD lesions. This review briefly outlines the composition and functions of the TGF-β/Smad signaling pathway, elucidates the mechanisms by which this pathway regulates DKD, and focuses on summarizing major studies from the past decade on flavonoid-based interventions in DKD through targeted inhibition of the TGF-β/Smad signaling pathway. Furthermore, it discusses the considerable therapeutic potential of flavonoids in the treatment of this disease, aiming to provide a scientific basis for future clinical prevention and treatment of DKD and to promote the development of targeted drugs.
3.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
4.Expert consensus on prevention and control of respiratory infectious diseases in railway stations trains in China
Guoping ZHANG ; Jinshu YIN ; Xiaodong YUAN ; Liang CHEN ; Xiaoshan LIU ; Shiwei MA ; Qingyi JIN ; Chunhong ZHU ; Ting LIU ; Jing HUANG ; Yuewei ZHANG ; Hui CHEN ; Xiao LIU
Chinese Journal of Nosocomiology 2025;35(16):2401-2405
OBJECTIVE To formulate an expert consensus on the prevention and control of respiratory infectious diseases in railway stations and trains in China,and to standardize the prevention and control of respiratory infec-tious diseases in railway stations and trains scientifically.METHODS The government authorities organized multi-ple prevention and control experts from transportation,medical care and prevention fields to conduct in-depth re-search through methods such as meetings and on-site investigations,and combined with their practical experi-ence in this field to formulate this expert consensus.RESULTS In-depth studies were conducted on the prevention and control strategies,measures and emergency response system construction of respiratory infectious diseases in railway stations and trains,and this expert consensus was formed.CONCLUSION This expert consensus supple-ments improves the existing prevention and control system for respiratory infectious diseases in railway stations and trains,and provides an important reference basis for the prevention and control of respiratory infectious disea-ses in railway stations and trains.
5.Preparation and Performance Test of Highly Stable Ammonium Ion Selective Electrode Based on Hydrophobic Solid Contact Layer
Chen-Yu LIU ; Jia-Wen YIN ; Yun-Zhe HAN ; Sheng-Kang LU ; Qing-Hui JIN
Chinese Journal of Analytical Chemistry 2025;53(5):774-784
The stability of ammonium ion selective electrode is an important indicator to ensure accurate monitoring of ammonia nitrogen concentration in drinking water.However,in long-term monitoring process,interfering ions and water molecules in water samples may penetrate into the interior of the ammonium ion selective electrode to form a water layer,which affects the potential response and stability of the electrode.Perfluorooctanoic acid is a low surface energy material,and doping it in polyaniline can reduce surface energy of the composite and improve surface roughness.In this work,five ammonium ion selective electrodes were prepared by doping polyaniline with different concentrations of perfluorooctanoic acid as a solid contact layer,which made the solid contact layer of electrode had hydrophobic properties,thereby improving stability of the ammonium ion selective electrode.The stability of the ion-selective electrode was evaluated by potential drift experiment,and the optimal doping concentration of perfluorooctanoic acid in the sediment solution was determined to be 5 mmol/L.The experiment results showed that the solid contact layer had a water contact angle of 132o under the doping concentration,the potential drift rate was 41.66 μV/h,and potential drift rate in the aqueous layer test was 1.31 mV/h,which were all better than those of the unmodified electrode.The standard deviation of the electrode potential was 1.42 mV,which was obviously superior to that of the unmodified electrode.The characteristics of high stability of the electrode made it suitable for long-term monitoring of ammonia nitrogen content in water samples.
6.Correlations of sleep quality and architecture with heart rate variability in patients with stenoses of vertebrobasilar artery system and internal carotid artery system
Suisui MA ; Changming WEN ; Yanlu JIA ; Hui LI ; Mengya XU ; Xueqing CUI ; Shuning SUN ; Yaoheng ZHANG ; Haozhe YIN ; Chunling LIU
Chinese Journal of Neuromedicine 2025;24(4):362-369
Objective:To explore the correlations of sleep quality and architecture with heart rate variability (HRV) in patients with stenoses of vertebrobasilar artery system and internal carotid artery system.Methods:A retrospective study was performed; 72 patients with stenosis or occlusion of the head and neck arteries (not resulting in cerebral infarction) admitted to Department of Neurology, Second Affiliated Hospital of Zhengzhou University from June 2023 to June 2024 were chosen, including 33 patients with moderate-to-severe stenosis or occlusion of the vertebrobasilar system (VB group) and 39 patients with moderate-to-severe stenosis or occlusion of the internal carotid artery system (ICA group). Pittsburgh sleep quality index (PSQI) and polysomnography (PSG) were used to evaluate the sleep quality and architecture, respectively; and 24-hour ambulatory electrocardiogram was used to assess the HRV. Differences in PSQI score, PSG and HRV parameters between the two groups were compared; partial correlation analysis was used to explore the correlations of HRV parameters with PSQI scores and PSG parameters; multivariate linear regression was used to analyze the independent influencing factors for HRV.Results:(1) Compared with the ICA group, the VB group exhibited significantly higher PSQI scores, spontaneous arousal index (SAI), ratio of time of stage 1 non-rapid eye movement sleep/total sleep time (T N1/T t), and apnea-hypopnea index (AHI), while significantly lower ratio of time of rapid eye movement sleep/total sleep time (T R/T t), spindle wave density in stage 2 non-rapid eye movement sleep (N2), lowest blood oxygen saturation, standard deviation of normal to normal intervals (SDNN) of all sinus beats, low-frequency power (LF), and high-frequency power (HF, P<0.05). (2) In both VB group and ICA group, SDNN was negatively correlated with PSQI score ( r=-0.461, P=0.020; r=-0.378, P=0.036). In the VB group, SDNN was negatively correlated with T N1/T t ( r=-0.467, P=0.019) and SAI ( r=-0.551, P=0.004), and positively correlated with ratio of time of stage 3 non-rapid eye movement sleep/total sleep time (T N3/T t, r=0.686, P<0.001) and spindle wave density in N2 ( r=0.518, P=0.008); LF and HF were negatively correlated with SAI ( r=-0.481, P=0.015; r=-0.564, P=0.003). In the ICA group, HF was negatively correlated with spindle wave density in N2 ( r=-0.369; P=0.041). (3) Multivariate linear regression results indicated that T N3/T t (β=0.348, P=0.018), SAI (β=-0.330, P=0.018), and spindle wave density in N2 (β=0.286, P=0.013) were independent influencing factors for Ln_SDNN in patients with moderate-to-severe stenosis or occlusion of the vertebrobasilar system. Conclusion:Patients with stenosis or occlusion of the vertebrobasilar system exhibit poorer subjective sleep quality, increased light sleep, heightened arousal, and reduced sleep stability compared with those with stenosis or occlusion of the internal carotid artery system, which may be caused by the imbalance of autonomic nerve function.
7.Strengthening the Construction of Clinical Quality Control System for MRI Equipment to Ensure Their Efficacy in Clinical Application
Hongxia YIN ; Chengwei LI ; Yawen LIU ; Hui XU ; Yu ZHANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):583-586
With the rapid increase in the ownership of MRI equipment in China,quality control,particularly in clinical usage aspects,has become critically important.For clinical quality control of MRI systems,it is essential to establish comprehensive workflow principles encompassing multiple elements such as personnel,equipment,standards,tools and methodologies.To advance the standardization and widespread adoption of clinical quality control for MRI equipment,efforts must focus on strengthening regulatory frameworks,advancing phantom research,development and enhancing professional expertise.Concurrently,continuous improvements in training programs and supervision mechanisms are necessary to ensure the effective implementation of MRI clinical quality control practices.Furthermore,in the era of digital healthcare,clinical quality assurance for MRI equipment is evolving toward automation and intelligent solutions,providing higher-quality and more efficient assurance for clinical applications.
8.Automatic Measurement Method for Spatial Resolution of MRI Based on the ACR Phantom
Yu ZHANG ; Hongxia YIN ; Yawen LIU ; Pengling REN ; Yanjun HU ; Tianxin CHENG ; Zhenghan YANG ; Zhenchang WANG ; Hui XU
Chinese Journal of Medical Imaging 2025;33(6):595-600,606
Purpose To measure the spatial resolution in MRI quality control testing automatically based on the American College of Radiology(ACR)phantom using the support vector machine(SVM)method,and the feasibility,accuracy and measurement speed of this method are explored.Materials and Methods Quality control tests were performed using eight MRI devices at Beijing Friendship Hospital of Capital Medical University.A retrospective study was conducted on 71 MRI quality control test images collected based on ACR phantoms between 2017 and 2019.The images were preprocessed by binarization,extraction region of interest and so on.An SVM-based classification model was constructed for analyzing the spatial resolution of dot arrays in row and column directions.The dataset was randomly split into a training set and a test set.The generalization performance of the classification model in this study was evaluated through accuracy,precision,recall and F1 score on the test set.Comparing the results of spatial resolution measurements obtained by both manual and automatic method,we demonstrated the feasibility and accuracy of the method.Additionally,the time taken for the automatic spatial resolution measurement was recorded.Results In this study,the proposed method of automatically measuring the spatial resolution of ACR phantom test images using SVM was feasible,high accuracy and short time.In classification performance test,the accuracy of the spatial resolution of the row directional latices was 95%,the precision was 100%.The accuracy of the spatial resolution of the column directional latices was 97%,the precision was 100%.Among the test cases,the results of automatic measurements matched those of manual measurements in 13 out of 14 cases.On average,automatic spatial resolution measurement took 0.158 seconds per case.Conclusion This study achieves automatic measurement of spatial resolution in MRI quality control based on the ACR phantom using SVM method.The method demonstrates high accuracy and fast measurement speeds,holding significant implications for future rapid MRI quality control stability testing.
9.Automatic Detection of Quality Control Performance of Radio Frequency Coils Based on ACR Phantom
Yawen LIU ; Hongxia YIN ; Yu ZHANG ; Pengling REN ; Yanjun HU ; Hui XU ; Zhenghan YANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):601-606
Purpose To explore an automatic detection method for quality control performance indicators of radio frequency coils based on American College of Radiology(ACR)phantom,and verify its accuracy stability and computational efficiency.Materials and Methods A retrospective study was conducted on 50 quality control images collected based on ACR phantom in Beijing Friendship Hospital,Capital Medical University from May 2017 to July 2019.The measurement and calculation methods of signal noise ratio(SNR),percent image uniformity(PIU)and percent signal ghosting(PSG)were used to automatically calculate the above indicators using a self-designed program in Python.A simple linear regression analysis on the automatically calculated SNR,PSG and PIU values compared to the manually measured results was performed,and Bland-Altman analysis was used to calculate the percentage difference to evaluate the consistency and bias between the performance indicators calculated by the two methods.The time consumption of two detection methods was compared to verify their computational complexity and efficiency.Results There was a strong correlation between the performance indicators SNR,PSG and PIU of radio frequency coils measured and calculated automatically and manually(r=0.991 4,0.992 8 and 0.909 8,all P<0.0001).The Bland-Altman results showed that most of the data fall within the 95%confidence interval and were evenly distributed.In terms of computational complexity and efficiency,compared to the complex manual delineation and calculation of 2-3 minutes per case,automatic detection could simultaneously obtain SNR,PSG and PIU values in less than 1 second.Conclusion The automatic and manual measurement methods have good consistency,and the automatic detection method is easy to operate,which is helpful for the daily quality control work and performance monitoring of radio frequency coils.
10.Specific effect of inserted sham acupuncture and its impact on the estimation of acupuncture treatment effect in randomized controlled trials: A systematic survey.
Xiao-Chao LUO ; Jia-Li LIU ; Ming-Hong YAO ; Ye-Meng CHEN ; Arthur Yin FAN ; Fan-Rong LIANG ; Ji-Ping ZHAO ; Ling ZHAO ; Xu ZHOU ; Xiao-Ying ZHONG ; Jia-Hui YANG ; Bo LI ; Ying ZHANG ; Xin SUN ; Ling LI
Journal of Integrative Medicine 2025;23(6):630-640
BACKGROUND:
The use of inserted sham acupuncture as a placebo in randomized controlled trials (RCTs) is controversial, because it may produce specific effects that cause an underestimation of the effect of acupuncture treatment.
OBJECTIVE:
This systematic survey investigates the magnitude of insert-specific effects of sham acupuncture and whether they affect the estimation of acupuncture treatment effects.
SEARCH STRATEGY:
PubMed, Embase and Cochrane Central Register of Controlled Trials were searched to identify acupuncture RCTs from their inception until December 2022.
INCLUSION CRITERIA:
RCTs that evaluated the effects of acupuncture compared to sham acupuncture and no treatment.
DATA EXTRACTION AND ANALYSIS:
The total effect measured for an acupuncture treatment group in RCTs were divided into three components, including the natural history and/or regression to the mean effect (controlled for no-treatment group), the placebo effect, and the specific effect of acupuncture. The first two constituted the contextual effect of acupuncture, which is mimicked by a sham acupuncture treatment group. The proportion of acupuncture total effect size was considered to be 1. The proportion of natural history and/or regression to the mean effect (PNE) and proportional contextual effect (PCE) of included RCTs were pooled using meta-analyses with a random-effect model. The proportion of acupuncture placebo effect was the difference between PCE and PNE in RCTs with non-inserted sham acupuncture. The proportion of insert-specific effect of sham acupuncture (PIES) was obtained by subtracting the proportion of acupuncture placebo effect and PNE from PCE in RCTs with inserted sham acupuncture. The impact of PIES on the estimation of acupuncture's treatment effect was evaluated by quantifying the percentage of RCTs that the effect of outcome changed from no statistical difference to statistical difference after removing PIES in the included studies, and the impact of PIES was externally validated in other acupuncture RCTs with an inserted sham acupuncture group that were not used to calculate PIES.
RESULTS:
This analysis included 32 studies with 5492 patients. The overall PNE was 0.335 (95% confidence interval [CI], 0.255-0.415) and the PCE of acupuncture was 0.639 (95% CI, 0.567-0.710) of acupuncture's total effect. The proportional contribution of the placebo effect to acupuncture's total effect was 0.191, and the PIES was 0.189. When we modeled the exclusion of the insert-specific effect of sham acupuncture, the acupuncture treatment effect changed from no difference to a significant difference in 45.45% of the included RCTs, and in 40.91% of the external validated RCTs.
CONCLUSION
The insert-specific effect of sham acupuncture in RCTs represents 18.90% of acupuncture's total effect and significantly affects the evaluation of the acupuncture treatment effect. More than 40% of RCTs that used inserted sham acupuncture would draw different conclusions if the PIES had been controlled for. Considering the impact of the insert-specific effect of sham acupuncture, caution should be taken when using inserted sham acupuncture placebos in RCTs. Please cite this article as: Luo XC, Liu JL, Yao MH, Chen YM, Fan AY, Liang FR, Zhao JP, Zhao L, Zhou X, Zhong XY, Yang JH, Li B, Zhang Y, Sun X, Li L. Specific effect of inserted sham acupuncture and its impact on the estimation of acupuncture treatment effect in randomized controlled trials: A systematic survey. J Integr Med. 2025; 23(6):630-640.
Acupuncture Therapy/methods*
;
Humans
;
Randomized Controlled Trials as Topic
;
Placebo Effect
;
Placebos
;
Treatment Outcome


Result Analysis
Print
Save
E-mail