1.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
2.Design of sinusoidal excitation phased array ultrasound focusing system
Shi-yu WANG ; Xu LIU ; Fang-xuan CHU ; Tao YIN ; Zhi-peng LIU ; Xiao-qing ZHOU
Chinese Medical Equipment Journal 2025;46(5):14-20
Objective To design a phased array ultrasonic focusing control system based on sinusoidal signal excitation in order to avoid the introduction of high-frequency interference components into the ultrasonic transducer and improve the electronic focusing performance of phased array ultrasound.Methods The system designed mainly used the high-speed field programmable gate array(FPGA)chip combined with the high-speed digital to analog converter(DAC)to realize synchronous output and control of multi-channel sinusoidal signals.There were 8 sinusoidal excitation emission modules based on FPGA and DAC and one sinusoidal ultrasonic excitation control module based on ZYNQ MPSoC involved in the hardware part of the system,in which the emission modules generated multi-channel sinusoidal excitations and timing control of sinusoidal signals within the module and the control module was responsible for controlling the triggering timing between each sinusoidal excitation transmitter module.The system developed had its software designed with MATLAB App Designer to improve the human-computer interaction experience.Performance verification was carried out for the system by testing the output waveform,inter-channel delay error and focused sound field of each channel.Results The system developed achieved generation and timing control of 64-channel sinusoidal ultrasound excitations,with the output channel main frequency being 0.5 MHz,amplitude within 0 and±12.5 V and the inter-channel delay errors not higher than 26.0 ns;a focused sound field with a focal spot diameter of 4.2 mm(-3 dB)at a depth of 50 mm was obtained when the system was applied to driving a 64-array phased-array transducer.Conclusion The system designed is capable of realizing ultrasonic electron focusing under sinusoidal excitation,which helps to improve the focusing resolution of non-invasive and precise deep brain stimulation techniques relying on the accuracy of ultrasonic focusing such as transcranial magneto-acoustic stimulation(TMAS)and transcranial ultrasonic stimulation(TUS).[Chinese Medical Equipment Journal,2025,46(5):14-20]
3.USP20 as a super-enhancer-regulated gene drives T-ALL progression via HIF1A deubiquitination.
Ling XU ; Zimu ZHANG ; Juanjuan YU ; Tongting JI ; Jia CHENG ; Xiaodong FEI ; Xinran CHU ; Yanfang TAO ; Yan XU ; Pengju YANG ; Wenyuan LIU ; Gen LI ; Yongping ZHANG ; Yan LI ; Fenli ZHANG ; Ying YANG ; Bi ZHOU ; Yumeng WU ; Zhongling WEI ; Yanling CHEN ; Jianwei WANG ; Di WU ; Xiaolu LI ; Yang YANG ; Guanghui QIAN ; Hongli YIN ; Shuiyan WU ; Shuqi ZHANG ; Dan LIU ; Jun-Jie FAN ; Lei SHI ; Xiaodong WANG ; Shaoyan HU ; Jun LU ; Jian PAN
Acta Pharmaceutica Sinica B 2025;15(9):4751-4771
T-cell acute lymphoblastic leukemia (T-ALL) is a highly aggressive hematologic malignancy with a poor prognosis, despite advancements in treatment. Many patients struggle with relapse or refractory disease. Investigating the role of the super-enhancer (SE) regulated gene ubiquitin-specific protease 20 (USP20) in T-ALL could enhance targeted therapies and improve clinical outcomes. Analysis of histone H3 lysine 27 acetylation (H3K27ac) chromatin immunoprecipitation sequencing (ChIP-seq) data from six T-ALL cell lines and seven pediatric samples identified USP20 as an SE-regulated driver gene. Utilizing the Cancer Cell Line Encyclopedia (CCLE) and BloodSpot databases, it was found that USP20 is specifically highly expressed in T-ALL. Knocking down USP20 with short hairpin RNA (shRNA) increased apoptosis and inhibited proliferation in T-ALL cells. In vivo studies showed that USP20 knockdown reduced tumor growth and improved survival. The USP20 inhibitor GSK2643943A demonstrated similar anti-tumor effects. Mass spectrometry, RNA-Seq, and immunoprecipitation revealed that USP20 interacted with hypoxia-inducible factor 1 subunit alpha (HIF1A) and stabilized it by deubiquitination. Cleavage under targets and tagmentation (CUT&Tag) results indicated that USP20 co-localized with HIF1A, jointly modulating target genes in T-ALL. This study identifies USP20 as a therapeutic target in T-ALL and suggests GSK2643943A as a potential treatment strategy.
4.Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture-dislocation in adults (version 2025)
Qingde WANG ; Tongwei CHU ; Jian DONG ; Liangjie DU ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Yong HAI ; Da HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Fang LI ; Feng LI ; Li LI ; Weishi LI ; Fangcai LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Keya MAO ; Xuexiao MA ; Yong QIU ; Limin RONG ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Yu WANG ; Qinghe WANG ; Jigong WU ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Yong YANG ; Qiang YANG ; Cao YANG ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Zezhang ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Yan ZENG ; Dingjun HAO ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(3):243-252
Cervical spinal cord injury without fracture-dislocation (CSCIWFD) is referred to as a special type of cervical spinal cord injury characterized by traumatic spinal cord dysfunction and no significant bony structural abnormalities on imagines. Duo to the high risk of missed diagnosis during the initial consultation, CSCIWFD may lead to progressive neurological deterioration or even complete paralysis, severely impacting patients′ prognosis. Currently, there are no established consensuses over the diagnosis and treatment of CSCIWFD, such as the lack of evidence-based standards for indications of non-surgical treatment and risk of secondary neurological injury, as well as debates over the optimal timing for surgical intervention and indications for different surgical approaches. To address these issues, the Spine Trauma Group of the Orthopedic Branch of the Chinese Medical Doctor Association organized experts in the relevant fields to formulate Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture- dislocation in adults ( version 2025) . Based on evidence-based medicine and the principles of scientific rigor and clinical applicability, the guidelines proposed 11 recommendations covering terminology, diagnosis, evaluation treatment, and rehabilitation, etc., aiming to standardize the management of CSCIWFD.
5.Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique (version 2025)
Sihao HE ; Junchao XING ; Tongwei CHU ; Zhengqi CHANG ; Xigao CHENG ; Fei DAI ; Xiaobing JIANG ; Jie HAO ; Jiang HU ; Jinghui HUANG ; Tianyong HOU ; Fei LUO ; Bo LIAO ; Changqing LI ; Lei LIU ; Guodong LIU ; Peng LIU ; Sheng LU ; Weishi LI ; Yang LIU ; Zhen LIU ; Wei MEI ; Peifu TANG ; Bing WANG ; Bing WANG ; Ce WANG ; Hongli WANG ; Liang WANG ; Shengru WANG ; Xiaobin WANG ; Yang WANG ; Yingfeng WANG ; Zheng WANG ; Jianzhong XU ; Guoyong YIN ; Haiyang YU ; Qiang YANG ; Zhaoming YE ; Bin ZHANG ; Chengmin ZHANG ; Jun ZOU ; Qiang ZHOU ; Min ZHAO ; Rui ZHOU ; Xiaojun ZHANG ; Yongfei ZHAO ; Zhongrong ZHANG ; Zehua ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2025;41(11):1035-1047
For middle-aged and elderly patients with conditions such as spinal fractures and degenerative spinal diseases, spinal internal fixation is a core surgical procedure for reconstructing spinal stability, heavily relying on the biomechanical stability provided by pedicle screw systems. Whereas, these patients are often complicated by osteoporosis that can significantly compromise the stability of the bone-pedicle screw interface, leading to a marked increase in pedicle screw loosening and surgical failure rates. The bone cement-augmented pedicle screw technique, which involves injecting bone cement into the vertebral body or screw trajectory to optimize the mechanical properties of the bone-pedicle screw composite, has been proven to significantly enhance fixation strength and effectively prevent screw-related failures, thereby reducing the incidence of internal fixation failure in high-risk populations undergoing spinal fusion. However, the widespread clinical application of this technique has faced challenges such as inaccurate clinical decision-making (indication and contraindication selection), non-standardized operative practices, and insufficient awareness of complication prevention, resulting in considerable variability in clinical outcomes and even severe complications. To address this, Prof. Luo Fei from First Affiliated Hospital of Army Medical University initiated the project and the Chinese Association Orthopaedic Surgeons organized relevant experts to develop the Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique ( version 2025), based on current evidence. The guidelines put forward 8 recommendations regarding the clinical value, scope of application, and operational standards of the technique, aiming to provide evidence-based medical support and technical standardization for clinical decision-making.
6.Design of sinusoidal excitation phased array ultrasound focusing system
Shi-yu WANG ; Xu LIU ; Fang-xuan CHU ; Tao YIN ; Zhi-peng LIU ; Xiao-qing ZHOU
Chinese Medical Equipment Journal 2025;46(5):14-20
Objective To design a phased array ultrasonic focusing control system based on sinusoidal signal excitation in order to avoid the introduction of high-frequency interference components into the ultrasonic transducer and improve the electronic focusing performance of phased array ultrasound.Methods The system designed mainly used the high-speed field programmable gate array(FPGA)chip combined with the high-speed digital to analog converter(DAC)to realize synchronous output and control of multi-channel sinusoidal signals.There were 8 sinusoidal excitation emission modules based on FPGA and DAC and one sinusoidal ultrasonic excitation control module based on ZYNQ MPSoC involved in the hardware part of the system,in which the emission modules generated multi-channel sinusoidal excitations and timing control of sinusoidal signals within the module and the control module was responsible for controlling the triggering timing between each sinusoidal excitation transmitter module.The system developed had its software designed with MATLAB App Designer to improve the human-computer interaction experience.Performance verification was carried out for the system by testing the output waveform,inter-channel delay error and focused sound field of each channel.Results The system developed achieved generation and timing control of 64-channel sinusoidal ultrasound excitations,with the output channel main frequency being 0.5 MHz,amplitude within 0 and±12.5 V and the inter-channel delay errors not higher than 26.0 ns;a focused sound field with a focal spot diameter of 4.2 mm(-3 dB)at a depth of 50 mm was obtained when the system was applied to driving a 64-array phased-array transducer.Conclusion The system designed is capable of realizing ultrasonic electron focusing under sinusoidal excitation,which helps to improve the focusing resolution of non-invasive and precise deep brain stimulation techniques relying on the accuracy of ultrasonic focusing such as transcranial magneto-acoustic stimulation(TMAS)and transcranial ultrasonic stimulation(TUS).[Chinese Medical Equipment Journal,2025,46(5):14-20]
7.Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture-dislocation in adults (version 2025)
Qingde WANG ; Tongwei CHU ; Jian DONG ; Liangjie DU ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Yong HAI ; Da HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Fang LI ; Feng LI ; Li LI ; Weishi LI ; Fangcai LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Keya MAO ; Xuexiao MA ; Yong QIU ; Limin RONG ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Yu WANG ; Qinghe WANG ; Jigong WU ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Yong YANG ; Qiang YANG ; Cao YANG ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Zezhang ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Yan ZENG ; Dingjun HAO ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(3):243-252
Cervical spinal cord injury without fracture-dislocation (CSCIWFD) is referred to as a special type of cervical spinal cord injury characterized by traumatic spinal cord dysfunction and no significant bony structural abnormalities on imagines. Duo to the high risk of missed diagnosis during the initial consultation, CSCIWFD may lead to progressive neurological deterioration or even complete paralysis, severely impacting patients′ prognosis. Currently, there are no established consensuses over the diagnosis and treatment of CSCIWFD, such as the lack of evidence-based standards for indications of non-surgical treatment and risk of secondary neurological injury, as well as debates over the optimal timing for surgical intervention and indications for different surgical approaches. To address these issues, the Spine Trauma Group of the Orthopedic Branch of the Chinese Medical Doctor Association organized experts in the relevant fields to formulate Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture- dislocation in adults ( version 2025) . Based on evidence-based medicine and the principles of scientific rigor and clinical applicability, the guidelines proposed 11 recommendations covering terminology, diagnosis, evaluation treatment, and rehabilitation, etc., aiming to standardize the management of CSCIWFD.
8.Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique (version 2025)
Sihao HE ; Junchao XING ; Tongwei CHU ; Zhengqi CHANG ; Xigao CHENG ; Fei DAI ; Xiaobing JIANG ; Jie HAO ; Jiang HU ; Jinghui HUANG ; Tianyong HOU ; Fei LUO ; Bo LIAO ; Changqing LI ; Lei LIU ; Guodong LIU ; Peng LIU ; Sheng LU ; Weishi LI ; Yang LIU ; Zhen LIU ; Wei MEI ; Peifu TANG ; Bing WANG ; Bing WANG ; Ce WANG ; Hongli WANG ; Liang WANG ; Shengru WANG ; Xiaobin WANG ; Yang WANG ; Yingfeng WANG ; Zheng WANG ; Jianzhong XU ; Guoyong YIN ; Haiyang YU ; Qiang YANG ; Zhaoming YE ; Bin ZHANG ; Chengmin ZHANG ; Jun ZOU ; Qiang ZHOU ; Min ZHAO ; Rui ZHOU ; Xiaojun ZHANG ; Yongfei ZHAO ; Zhongrong ZHANG ; Zehua ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2025;41(11):1035-1047
For middle-aged and elderly patients with conditions such as spinal fractures and degenerative spinal diseases, spinal internal fixation is a core surgical procedure for reconstructing spinal stability, heavily relying on the biomechanical stability provided by pedicle screw systems. Whereas, these patients are often complicated by osteoporosis that can significantly compromise the stability of the bone-pedicle screw interface, leading to a marked increase in pedicle screw loosening and surgical failure rates. The bone cement-augmented pedicle screw technique, which involves injecting bone cement into the vertebral body or screw trajectory to optimize the mechanical properties of the bone-pedicle screw composite, has been proven to significantly enhance fixation strength and effectively prevent screw-related failures, thereby reducing the incidence of internal fixation failure in high-risk populations undergoing spinal fusion. However, the widespread clinical application of this technique has faced challenges such as inaccurate clinical decision-making (indication and contraindication selection), non-standardized operative practices, and insufficient awareness of complication prevention, resulting in considerable variability in clinical outcomes and even severe complications. To address this, Prof. Luo Fei from First Affiliated Hospital of Army Medical University initiated the project and the Chinese Association Orthopaedic Surgeons organized relevant experts to develop the Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique ( version 2025), based on current evidence. The guidelines put forward 8 recommendations regarding the clinical value, scope of application, and operational standards of the technique, aiming to provide evidence-based medical support and technical standardization for clinical decision-making.
9.Structural Design and Analysis of Portable Intelligent Wheelchair for Knee Rehabilitation
Dongmei MA ; Jingyan WANG ; Liming PAN ; Jinshi CHEN ; Tianyue CHU ; Lei HUANG ; Baoyue YIN ; Xin XU
Chinese Journal of Medical Instrumentation 2024;48(4):445-450
Objective In order to address the issues of inconvenience,high medical costs,and lack of universality associated with traditional knee rehabilitation equipment,a portable intelligent wheelchair for knee rehabilitation was designed in this study.Methods Based on the analysis of the knee joint's structure and rehabilitation mechanisms,an electric pushrod-driven rehabilitation institution was developed.A multi-functional module was designed with a modular approach,and the control of the wheelchair body and each functional module was implemented using an STM32 single-chip microcomputer.A three-dimensional model was established using SolidWorks software.In conjunction with Adams and Ansys simulation software,kinematic and static analyses were conducted on the knee joint rehabilitation institution and its core components.A prototype was constructed to verify the equipment's actual performance.Results According to the prototype testing,the actual range of motion for the knee joint swing rod is 15.1°~88.9°,the angular speed of the swing rod ranges from-7.9 to 8.1°/s,the angular acceleration of the swing rod varies from-4.2 to 1.6°/s2,the thrust range of the electric pushrod is-82.6 to 153.1 N,and the maximum displacement of the load pedal is approximately 1.7 mm,with the leg support exhibiting a maximum deformation of about 1.5 mm.Conclusion The intelligent knee joint rehabilitation wheelchair meets the designed functions and its actual performance aligns with the design criteria,thus validating the rationality and feasibility of the structural design.
10.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.


Result Analysis
Print
Save
E-mail