1.Expert consensus on clinical application of parenteral direct thrombin inhibitors in perioperative period
Mingyu JIANG ; Yuan BIAN ; Lizhu HAN ; Qinan YIN ; Fengjiao KANG ; Anhua WEI ; Danjie ZHAO ; Lin WANG ; Ying SHAO ; Li TANG ; Yi WANG ; Shuhong LIANG ; Huijuan LIU ; Guirong XIAO ; Yue LI
China Pharmacy 2026;37(6):689-699
OBJECTIVE To form an expert consensus on the clinical application of parenteral direct thrombin inhibitors (DTIs) in patients during the perioperative period. METHODS Led by Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital (the Affiliated Hospital of UESTC), a multidisciplinary working group was established. Through literature review and the Delphi method, clinical questions related to the rational perioperative use of parenteral DTIs were identified. A structured design was adopted using the “Population-Intervention-Comparison-Outcome” framework; systematic searches were conducted in CNKI, Medline, Embase and other databases. Relevant evidence from randomized controlled trials and cohort studies was included and synthesized. Evidence quality was assessed using the Grades of Recommendations Assessment,Development and Evaluation (GRADE) approach, and recommendations were formulated through multiple rounds of Delphi surveys and expert consensus meetings. RESULTS &CONCLUSIONS Seven recommendations (each with an expert consensus rate exceeding 90%) on the use of parenteral DTIs in perioperative patients were developed. These recommendations specify drug selection, dosing ranges, key monitoring points, and safety management strategies for parenteral DTIs in various scenarios, including the perioperative period of ventricular assist device implantation, the perioperative period of cardiac surgery, perioperative patients with lower-extremity atherosclerotic disease, the perioperative period of percutaneous coronary intervention in patients with acute coronary syndrome, the perioperative period of carotid artery stenting in patients with carotid stenosis, the perioperative period of patients with right heart thrombosis, and patients who develop related thrombosis and dysfunction after a central venous catheter insertion. In addition, warning and management pathways for perioperative bleeding and thrombotic events were proposed. This expert consensus, which is formulated based on the best available evidence, provides evidence-based guidance for standardized and individualized use of parenteral DTIs in perioperative period.
2.Clinical rapid evaluation of proprotein convertase subtilisin/kexin type 9 inhibitors for hypercholesterolemia
Xin YAO ; Fengjiao KANG ; Qinan YIN ; Lizhu HAN ; Yuan BIAN
China Pharmacy 2026;37(2):149-154
OBJECTIVE To conduct a clinical rapid evaluation of the marketed proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors in China, including evolocumab, tafolecimab, recaticimab, ebronucimab, ongericimab and inclisiran. METHODS Based on the Rapid Guide for Drug Evaluation and Selection in Chinese Medical Institutions (second edition), drug instructions, clinical diagnosis and treatment guidelines, and literature for six drugs were retrieved from CNKI, Wanfang Data, VIP, PubMed, Embase, Cochrane Library and related official websites. The clinical rapid evaluation was conducted from five aspects: pharmaceutical characteristics, effectiveness, safety, economy, and other attributes. RESULTS The pharmaceutical characteristics, effectiveness, safety, economy, other attributes, and total score of evolocumab scored 24, 27, 15.7, 10, 5.3, and 82 points, respectively. Tafolecimab scored 23.5, 23, 11.5, 9.97, 4.6, and 72.57 points, respectively. Recaticimab scored 20.5, 22, 15.5, 6.37, 3.5, and 67.87 points. Ebronucimab scored 20, 23, 11, 6.48, 3.5, and 63.98 points. Ongericimab scored 20.5, 23, 8.5, 4.83, 3.5, and 60.33 points. Inclisiran scored 25.5, 24, 13, 6.48, 5, and 73.98 points. CONCLUSIONS Evolocumab is the optimal choice for treating hypercholesterolemia and is recommended as the first-line option. Tafolecimab is the second-line option, and recaticimab is suitable for patients who are sensitive to drug adverse reactions. Inclisiran is suitable for patients with poor compliance. Ebronucimab and ongericimab are weakly recommended due to their later market introduction. Clinicians should make individualized drug selections based on factors such as patient risk level and compliance requirements.
3.TGF-β1-engineered Biomimetic Platelet Nanoparticles for Targeted Therapy of Ischemic Stroke
Li-Qi CHEN ; Tian-Fang KANG ; Guo-Jun HUANG ; Ting YIN ; Ai-Qing MA ; Lin-Tao CAI ; Hong PAN
Progress in Biochemistry and Biophysics 2026;53(3):697-710
ObjectivePost-ischemic acute inflammation and the subsequent persistent dysregulation of the immune microenvironment represent major pathological drivers that aggravate neuronal injury and severely restrict functional recovery following ischemic stroke. Although current reperfusion therapies partially restore blood flow, they fail to effectively modulate the secondary inflammatory cascade and oxidative stress, which remain critical barriers to neurological restoration. To address this challenge, this study aimed to engineer and systematically evaluate a biomimetic nanosystem composed of transforming growth factor-β1 (TGF-β1)-loaded platelet membrane-camouflaged lipid nanoparticles (PLP). This nanosystem was designed to achieve dual lesion-targeted delivery and immune microenvironment remodeling. By verifying its spatiotemporal accumulation, anti-inflammatory activity, and neuroprotective efficacy, we sought to establish an integrated therapeutic strategy that simultaneously enables lesion targeting, immune regulation, and functional recovery after ischemic injury. MethodsThe physicochemical properties of PLP, including hydrodynamic particle size, zeta potential, structural stability, and morphology, were characterized using dynamic light scattering, zeta potential analysis, and transmission electron microscopy. The preservation of platelet membrane-derived adhesion and immunoregulatory proteins was confirmed by SDS-PAGE through comparative analysis of protein band profiles between PLP and native platelet membranes. The in vitro biological activities of PLP were evaluated using two complementary cellular models. LPS-induced M1-polarized RAW264.7 macrophages were employed to assess inflammatory modulation, while oxygen glucose deprivation/reperfusion (OGD/R)-induced BV2 microglial cells and SH-SY5Y neuronal cells were utilized to investigate neuroinflammatory regulation and neuronal protection. For in vivo validation, a transient middle cerebral artery occlusion (tMCAO) mouse model was established to mimic ischemia-reperfusion injury. The spatiotemporal biodistribution and lesion-targeting capability of the PLP were monitored through live fluorescence imaging. Therapeutic efficacy was comprehensively evaluated by triphenyltetrazolium chloride (TTC) staining, glial fibrillary acidic protein (GFAP) immunofluorescence analysis, body weight monitoring, and neurological severity score (NSS) assessment. ResultsPLP nanoparticles displayed a uniform spherical morphology, nanoscale particle size distribution, and stable negative surface charge, indicating favorable colloidal stability and circulation potential. SDS-PAGE results confirmed the effective retention of key platelet membrane proteins associated with endothelial adhesion, immune evasion, and inflammatory regulation, demonstrating the successful biomimetic construction. Optimal therapeutic concentrations were determined in OGD/R-induced BV2 cells, where PLP exhibited excellent cytocompatibility and anti-inflammatory activity.In vitro experiments demonstrated that PLP significantly inhibited the polarization of RAW264.7 macrophages toward the pro-inflammatory M1 phenotype and markedly reduced neuronal apoptosis under ischemia-reperfusion conditions. In vivo fluorescence imaging revealed that PLP rapidly accumulated in the ischemic brain hemisphere and maintained prolonged retention for up to 7 d, suggesting enhanced lesion-specific targeting and sustained drug release. Compared with control group, PLP treatment significantly reduced cerebral infarct volume, attenuated reactive astrogliosis, improved weight recovery, and accelerated neurological functional restoration, as reflected by significantly improved NSS scores. ConclusionThis study establishes a multifunctional biomimetic nanoplatform that integrates platelet membrane-mediated active targeting with the anti-inflammatory, antioxidative, and neuroprotective properties of TGF-β1. The PLP system enables rapid lesion homing and long-term retention while synergistically regulating the post-stroke inflammatory microenvironment by suppressing pro-inflammatory immune activation, reducing neuronal apoptosis, and limiting excessive astrocyte reactivity. Importantly, this study proposes a conceptually therapeutic paradigm that combines targeted delivery with immune microenvironment remodeling to achieve comprehensive neurovascular protection. These findings provide strong experimental evidence supporting the translational potential of biomimetic nanotherapeutics as next-generation precision interventions for ischemic stroke.
4.Machine Learning-Based Computed Tomography-Derived Fractional Flow Reserve Predicts Need for Coronary Revascularisation Prior to Transcatheter Aortic Valve Implantation
Kai Dick David LEUNG ; Pan Pan NG ; Boris Chun Kei CHOW ; Keith Wan Hang CHIU ; Neeraj Ramesh MAHBOOBANI ; Yuet-Wong CHENG ; Eric Chi Yuen WONG ; Alan Ka Chun CHAN ; Augus Shing Fung CHUI ; Michael Kang-Yin LEE ; Jonan Chun Yin LEE
Cardiovascular Imaging Asia 2025;9(1):2-8
Objective:
Patients with severe symptomatic aortic stenosis are assessed for coronary artery disease (CAD) prior to transcatheter aortic valve implantation (TAVI) with treatment implications. Invasive coronary angiography (ICA) is the recommended modality but is associated with peri-procedural complications. Integrating machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) into existing TAVI-planning CT protocol may aid exclusion of significant CAD and thus avoiding ICA in selected patients.
Materials and Methods:
A single-center, retrospective study was conducted, 41 TAVI candidates with both TAVI-planning CT and ICA performed were analyzed. CT datasets were evaluated by a ML-based CT-FFR software. Beta-blocker and nitroglycerin were not administered in these patients. The primary outcome was to identify significant CAD. The diagnostic performance of CT-FFR was compared against ICA.
Results:
On per-patient level, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy were 89%, 94%, 80%, 97% and 93%, respectively. On per-vessel level, the sensitivity, specificity, PPV, NPV and diagnostic accuracy were 75%, 94%, 67%, 96% and 92%, respectively. The area under the receiver operative characteristics curve per individual coronary vessels yielded overall 0.90 (95% confidence interval 85%–95%). ICA may be avoided in up to 80% of patients if CT-FFR results were negative.
Conclusion
ML-based CT-FFR can provide accurate screening capabilities for significant CAD thus avoiding ICA. Its integration to existing TAVI-planning CT is feasible with the potential of improving the safety and efficiency of pre-TAVI CAD assessment.
5.Transforaminal interbody debridement and fusion with antibiotic-impregnated bone graft to treat pyogenic discitis and vertebral osteomyelitis: a comparative study in Asian population
Chao-Chien CHANG ; Hsiao-Kang CHANG ; Meng-Ling LU ; Adam WEGNER ; Re-Wen WU ; Tsung-Cheng YIN
Asian Spine Journal 2025;19(1):38-45
Methods:
Thirty patients with PDVO of the lumbar or thoracic spine treated with transforaminal interbody debridement and fusion (TIDF) with AIBG between March 2014 and May 2022 were reviewed (AIBG group). For comparative analysis, 28 PDVO patients who underwent TIDF without AIBG between January 2009 and June 2011 were enrolled (non-AIBG group). The minimum follow-up duration was 2 years. Clinical characteristics and surgical indications were comparable in the two groups. C-reactive protein (CRP) levels and the postoperative antibiotics course were compared between the two groups.
Results:
Surgical treatment for PDVO resulted in clinical improvement and adequate infection control. Despite the shorter postoperative intravenous antibiotic duration (mean: 19.0 days vs. 39.8 days), the AIBG group had significantly lower CRP levels at postoperative 4 and 6 weeks. The mean Visual Analog Scale pain scores improved from 7.3 preoperatively to 2.2 at 6 weeks postoperatively. The average angle correction at the last follow-up was 7.9°.
Conclusions
TIDF with AIBG for PDVO can achieve local infection control with a faster reduction in CRP levels, leading to a shorter antibiotic duration.
6.Comparison on chemical components of Angelicae Sinensis Radix before and after wine processing by HS-GC-IMS, HS-SPME-GC-MS, and UPLC-Q-Orbitrap-MS combined with chemometrics.
Xue-Hao SUN ; Jia-Xuan CHEN ; Jia-Xin YIN ; Xiao HAN ; Zhi-Ying DOU ; Zheng LI ; Li-Ping KANG ; He-Shui YU
China Journal of Chinese Materia Medica 2025;50(14):3909-3917
The study investigated the intrinsic changes in material basis of Angelicae Sinensis Radix during wine processing by headspace-gas chromatography-ion mobility spectrometry(HS-GC-IMS), headspace-solid phase microextraction-gas chromatography-mass spectrometry(HS-SPME-GC-MS), and ultra-high performance liquid chromatography-quadrupole-orbitrap mass spectrometry(UPLC-Q-Orbitrap-MS) combined with chemometrics. HS-GC-IMS fingerprints of Angelicae Sinensis Radix before and after wine processing were established to analyze the variation trends of volatile components and characterize volatile small-molecule substances before and after processing. Principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA) were employed for differentiation and difference analysis. A total of 89 volatile components in Angelicae Sinensis Radix were identified by HS-GC-IMS, including 14 unsaturated hydrocarbons, 16 aldehydes, 13 ketones, 9 alcohols, 16 esters, 6 organic acids, and 15 other compounds. HS-SPME-GC-MS detected 118 volatile components, comprising 42 unsaturated hydrocarbons, 11 aromatic compounds, 30 alcohols, 8 alkanes, 6 organic acids, 4 ketones, 7 aldehydes, 5 esters, and 5 other volatile compounds. UPLC-Q-Orbitrap-MS identified 76 non-volatile compounds. PCA revealed distinct clusters of raw and wine-processed Angelicae Sinensis Radix samples across the three detection methods. Both PCA and OPLS-DA effectively discriminated between the two groups, and 145 compounds(VIP>1) were identified as critical markers for evaluating processing quality, including 4-methyl-3-penten-2-one, ethyl 2-methylpentanoate, and 2,4-dimethyl-1,3-dioxolane detected by HS-GC-IMS, angelic acid, β-pinene, and germacrene B detected by HS-SPME-GC-MS, and L-tryptophan, licoricone, and angenomalin detected by UPLC-Q-Orbitrap-MS. In conclusion, the integration of the three detection methods with chemometrics elucidates the differences in the chemical material basis between raw and wine-processed Angelicae Sinensis Radix, providing a scientific foundation for understanding the processing mechanisms and clinical applications of wine-processed Angelicae Sinensis Radix.
Wine/analysis*
;
Gas Chromatography-Mass Spectrometry/methods*
;
Chromatography, High Pressure Liquid/methods*
;
Angelica sinensis/chemistry*
;
Solid Phase Microextraction/methods*
;
Drugs, Chinese Herbal/isolation & purification*
;
Chemometrics
;
Volatile Organic Compounds/chemistry*
;
Principal Component Analysis
;
Ion Mobility Spectrometry/methods*
7.A novel arterial coupler with non-return snap-fit connection approach optimized arterial end-to-end anastomotic technique: An experimental study.
Hong-Bo GUO ; Mo-Fei WANG ; Ren-Qi YIN ; Kang-Kang ZHI
Chinese Journal of Traumatology 2025;28(1):13-21
PURPOSE:
Hand-sewn anastomosis as the gold standard of vascular anastomosis cannot fully meet the requirements of vascular anastomosis in speed and quality. Various vascular couplers have been developed to ameliorate this situation. Most of them are mainly used for venous anastomosis rather than arterial anastomosis. Although it is generally acknowledged that in almost all operations involving vascular reconstruction, it is the arteries that need to be anastomosed faster and more accurately and not the veins. A dedicated device is needed for creating arterial anastomosis in an easy, timesaving, less damaging but reliable procedure. Therefore, we plan to develop a novel arterial coupler device and test pre-clinical safety and effectiveness.
METHODS:
In this cohort study, the rationality of this novel arterial coupler was preliminarily tested by finite element analysis before it was manufactured. Several factors restrict the use of vascular couplers in arterial anastomosis, such as arterial eversion, fixation, etc. The manufactured arterial couplers underwent in vitro and in vivo experiments. In vitro, isolated arteries of beagles were anastomosed with the assistance of an arterial coupler, and the anastomosed arteries were evaluated through anti-traction tests. In animal experiments, the bilateral femoral arteries of 5 beagles served as a control group. After dissection, the femoral artery on one side was randomly selected to be anastomosed with a quick arterial coupler (QAC) (QAC group), and the femoral artery on the other side was anastomosed by the same person using an end-to-end suture technique with a 6-0 Prolene suture (suture group). The bilateral femoral arteries of 5 beagles were used for coupler-assisted anastomosis and hand-sewn anastomosis in vivo, respectively. Success rate, blood loss, anastomotic time, clamp time, total operation time, and patency rate were recorded. The patency of anastomosed arteries was assessed using vascular Doppler ultrasound, electromagnetic flowmeter, and pathological examination (6 weeks after surgery).
RESULTS:
As a novel arterial coupler, QAC was successfully designed and manufactured by using poly lactic-co-glycolic acid raw materials and 3-dimensions printing technology. Its rationality was preliminarily tested through finite element analysis and related mechanical analysis methods. The isolated arteries were successfully anastomosed with the assistance of QAC in vitro testing, which showed good anti-traction properties. In animal studies, QAC-assisted arterial anastomosis has superior profiles compared to hand-sewn anastomosis in anastomotic time (7.80 ± 1.41 vs. 16.38 ± 1.04 min), clamp time (8.80 ± 1.41 vs. 14.14 ± 1.57 min), and total operation time (46.64 ± 2.38 vs. 51.96 ± 3.65 min). The results of electromagnetic flowmeter, vascular Doppler ultrasound, and pathological examination showed that QAC-assisted anastomotic arteries were superior to hand-sewn arteries in terms of postoperative blood flow (16.86 ± 3.93 vs. 10.36 ± 0.92 mL/min) and vascular patency in 6 weeks after surgery.
CONCLUSION
QAC is a well-designed and easily maneuverable device specialized for end-to-end arterial anastomosis. Application of this device may decrease thermal ischemia time and improve the patency of anastomotic arteries, thus, improving outcomes.
Animals
;
Anastomosis, Surgical/instrumentation*
;
Dogs
;
Femoral Artery/surgery*
;
Vascular Surgical Procedures/instrumentation*
;
Finite Element Analysis
8.Exogenous administration of heparin-binding epidermal growth factor-like growth factor improves erectile function in mice with bilateral cavernous nerve injury.
Minh Nhat VO ; Mi-Hye KWON ; Fang-Yuan LIU ; Fitri Rahma FRIDAYANA ; Yan HUANG ; Soon-Sun HONG ; Ju-Hee KANG ; Guo Nan YIN ; Ji-Kan RYU
Asian Journal of Andrology 2025;27(6):697-706
Prostate cancer is the second most common malignancy and the sixth leading cause of cancer-related death in men worldwide. Radical prostatectomy (RP) is the standard treatment for localized prostate cancer, but the procedure often results in postoperative erectile dysfunction (ED). The poor efficacy of phosphodiesterase 5 inhibitors after surgery highlights the need to develop new therapies to enhance cavernous nerve regeneration and improve the erectile function of these patients. In the present study, we aimed to examine the potential of heparin-binding epidermal growth factor-like growth factor (HB-EGF) in preserving erectile function in cavernous nerve injury (CNI) mice. We found that HB-EGF expression was reduced significantly on the 1 st day after CNI in penile tissue. Ex vivo and in vitro studies showed that HB-EGF promotes major pelvic ganglion neurite sprouting and neuro-2a (N2a) cell migration. In vivo studies showed that exogenous HB-EGF treatment significantly restored the erectile function of CNI mice to 86.9% of sham levels. Immunofluorescence staining showed that mural and neuronal cells were preserved by inducing cell proliferation and reducing apoptosis and reactive oxygen species production. Western blot analysis showed that HB-EGF upregulated protein kinase B and extracellular signal-regulated kinase activation and neurotrophic factor expression. Overall, HB-EGF is a major promising therapeutic agent for treating ED in postoperative RP.
Animals
;
Male
;
Heparin-binding EGF-like Growth Factor/therapeutic use*
;
Erectile Dysfunction/etiology*
;
Mice
;
Penis/drug effects*
;
Nerve Regeneration/drug effects*
;
Penile Erection/drug effects*
;
Peripheral Nerve Injuries/drug therapy*
;
Cell Proliferation/drug effects*
;
Apoptosis/drug effects*
;
Cell Movement/drug effects*
;
Prostatectomy/adverse effects*
;
Mice, Inbred C57BL
;
Reactive Oxygen Species/metabolism*
9.Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method.
Fuhao KANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(1):80-88
Hemodynamic monitoring can reflect cardiac function and blood perfusion and is an indispensable monitoring method in clinical practice. Invasive hemodynamic monitoring methods represented by the thermodilution method are limited in their clinical application scope because they require vascular cannulation. Non-invasive hemodynamic monitoring has attracted extensive attention from medical companies and clinicians at home and abroad in recent years due to its advantages such as safety, non-invasiveness, continuous monitoring, simple operation, and low cost. This paper designs a non-invasive hemodynamic monitoring system based on the impedance cardiography, including hardware, algorithm, software design, and performance parameter evaluation. Among them, the hardware part mainly includes a differential high-frequency constant current source stimulation circuit, impedance cardiogram signal acquisition, and ECG signal acquisition circuit. Signal processing includes wave filtering, impedance cardiogram signal calibration, and ECG signal and impedance cardiogram signal feature point recognition. According to the collected impedance cardiogram and ECG signals, hemodynamic parameters such as heart rate (HR), stroke volume (SV), cardiac output (CO), stroke index (SI), cardiac index (CI), and cardiac contractility index (ICON) are calculated based on the Nyboer thoracic cylinder model. After testing, the key technical indicators of the system hardware are better than that of the relevant medical device standards. The system was used to collect impedance cardiogram and ECG signal data from 40 volunteers. The calculated HR, SV, and CO, three important hemodynamic indicators, were compared with the ICONCore non-invasive cardiac output monitor of OSYPKA Medical in Germany. Their Pearson correlation coefficients were 0.992 ( P<0.001), 0.948 ( P<0.001), and 0.933 ( P<0.001), respectively, verifying that the designed system has high accuracy and reliability.
Cardiography, Impedance/methods*
;
Humans
;
Hemodynamic Monitoring/methods*
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Hemodynamics
;
Algorithms
;
Monitoring, Physiologic/methods*
;
Electrocardiography
10.Development of a Microstream End-Tidal Carbon Dioxide Monitoring System with Integrated Gas Circuit.
Yanan LIU ; Xuedong SONG ; Qi YIN ; Fuhao KANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(2):204-211
End-tidal carbon dioxide monitoring is an important means of evaluating human lung function and is widely used in fields such as clinical emergency treatment and cardiopulmonary resuscitation. This paper develops a microstream end-tidal carbon dioxide monitoring system. It adopts an integrated gas circuit design to further reduce the size of the equipment. The system uses the method of calculating the root mean square (RMS) of differential pressure signals to regulate the gas circuit flow, enabling the system to stably operate at a flow state of 30 mL/min. In addition, by simultaneously detecting multiple environmental parameters such as temperature and pressure, the system realizes system state monitoring and gas parameter compensation. The test results show that various indicators of the system meet the requirements of relevant standards, laying a good foundation for subsequent engineering applications.
Carbon Dioxide/analysis*
;
Equipment Design
;
Monitoring, Physiologic/methods*
;
Humans

Result Analysis
Print
Save
E-mail