1.Efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability complicated by vertebral artery anomalies
Peng ZOU ; Yansheng HUANG ; Xiaojun YU ; Xinliang ZHANG ; Lingjiang LI ; Yiguang HAO ; Ruirui BU ; Liujie XUE ; Xiaodong WANG ; Baorong HE ; Xiaoqiang HUANG ; Yuanting ZHAO
Chinese Journal of Trauma 2025;41(8):740-745
Objective:To evaluate the efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability (AAI) complicated by vertebral artery anomalies.Methods:A retrospective case series study was conducted to analyze the clinical data of 23 patients with AAI complicated by vertebral artery anomalies who were admitted to Honghui Hospital of Xi′an Jiaotong University between January 2019 and January 2023, including 10 males and 13 females, aged 19-70 years [(51.0±13.3)years]. Vertebral artery anomalies were categorized into unilateral high-riding vertebral artery with unilateral dominance ( n=14), bilateral high-riding vertebral arteries with unilateral dominance ( n=6), and ponticulus posticus ( n=3). All the patients underwent preoperative planning using a 3D-printed model of the atlantoaxial complex with the vertebral artery, followed by posterior atlantoaxial pedicle screw fixation with computer-assisted navigation. Operative duration and intraoperative blood loss were recorded. The accuracy of pedicle screw placement was assessed at 3 days postoperatively using the Gertzbein-Robbins classification. Visual analogue scale (VAS) scores and Japanese Orthopedic Association (JOA) scores were evaluated preoperatively, at 3 days, 3 months postoperatively, and at the last follow-up. Bony fusion was assessed using cervical CT with 3D reconstruction at the last follow-up. Complications were also observed. Results:All the patients were followed up for 12-19 months [(15.1±1.9)months]. The operative duration was 125-167 minutes [(140.6±10.9)minutes] and intraoperative blood loss was 200-600 ml [(295.7±77.8)ml]. At 3 days postoperatively, all the 66 pedicle screws were safely placed, with 60 screws (91%) rated as Gertzbein-Robbins Grade 0 and 6 screws (9%) as Grade 1. At 3 days and 3 months postoperatively, and at the last follow-up, the VAS scores were (4.0±1.0)points, (2.0±0.6)points, and (1.3±0.5)points, and the JOA scores were (14.2±1.2)points, (16.0±0.8)points, and (16.6±0.5)points, both of which were not only significantly improved compared with preoperative (5.6±1.3)points and (12.8±1.5)points, but also further improved over time ( P<0.05). At the last follow-up, 22 patients (96%) achieved satisfactory atlantoaxial bony fusion. No vertebral artery injury, spinal cord or nerve injury, cerebrospinal fluid leakage, or screw loosening were observed in any patients. Conclusion:For patients with AAI complicated by vertebral artery anomalies, 3D printing combined with computer navigation-assisted navigation for atlantoaxial pedicle screw implantation offers multiple advantages, including minimal surgical trauma, high screw placement accuracy, pain relief, neurological function improvement, high fusion rate, and lowered incidence of complications.
2.Efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability complicated by vertebral artery anomalies
Peng ZOU ; Yansheng HUANG ; Xiaojun YU ; Xinliang ZHANG ; Lingjiang LI ; Yiguang HAO ; Ruirui BU ; Liujie XUE ; Xiaodong WANG ; Baorong HE ; Xiaoqiang HUANG ; Yuanting ZHAO
Chinese Journal of Trauma 2025;41(8):740-745
Objective:To evaluate the efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability (AAI) complicated by vertebral artery anomalies.Methods:A retrospective case series study was conducted to analyze the clinical data of 23 patients with AAI complicated by vertebral artery anomalies who were admitted to Honghui Hospital of Xi′an Jiaotong University between January 2019 and January 2023, including 10 males and 13 females, aged 19-70 years [(51.0±13.3)years]. Vertebral artery anomalies were categorized into unilateral high-riding vertebral artery with unilateral dominance ( n=14), bilateral high-riding vertebral arteries with unilateral dominance ( n=6), and ponticulus posticus ( n=3). All the patients underwent preoperative planning using a 3D-printed model of the atlantoaxial complex with the vertebral artery, followed by posterior atlantoaxial pedicle screw fixation with computer-assisted navigation. Operative duration and intraoperative blood loss were recorded. The accuracy of pedicle screw placement was assessed at 3 days postoperatively using the Gertzbein-Robbins classification. Visual analogue scale (VAS) scores and Japanese Orthopedic Association (JOA) scores were evaluated preoperatively, at 3 days, 3 months postoperatively, and at the last follow-up. Bony fusion was assessed using cervical CT with 3D reconstruction at the last follow-up. Complications were also observed. Results:All the patients were followed up for 12-19 months [(15.1±1.9)months]. The operative duration was 125-167 minutes [(140.6±10.9)minutes] and intraoperative blood loss was 200-600 ml [(295.7±77.8)ml]. At 3 days postoperatively, all the 66 pedicle screws were safely placed, with 60 screws (91%) rated as Gertzbein-Robbins Grade 0 and 6 screws (9%) as Grade 1. At 3 days and 3 months postoperatively, and at the last follow-up, the VAS scores were (4.0±1.0)points, (2.0±0.6)points, and (1.3±0.5)points, and the JOA scores were (14.2±1.2)points, (16.0±0.8)points, and (16.6±0.5)points, both of which were not only significantly improved compared with preoperative (5.6±1.3)points and (12.8±1.5)points, but also further improved over time ( P<0.05). At the last follow-up, 22 patients (96%) achieved satisfactory atlantoaxial bony fusion. No vertebral artery injury, spinal cord or nerve injury, cerebrospinal fluid leakage, or screw loosening were observed in any patients. Conclusion:For patients with AAI complicated by vertebral artery anomalies, 3D printing combined with computer navigation-assisted navigation for atlantoaxial pedicle screw implantation offers multiple advantages, including minimal surgical trauma, high screw placement accuracy, pain relief, neurological function improvement, high fusion rate, and lowered incidence of complications.
3.Effect of Yiqi Huoxue Jiedu Fang on the growth,metastasis and angiogenesis of Lewis lung carcinomas
Yu HAO ; Bowen XU ; Yiguang WANG ; Qian WANG ; Quanying QIU ; Qifu HUANG
Chinese Journal of Pathophysiology 1986;0(01):-
AIM:To study the effect of Yiqi Huoxue Jiedu Fang(YHJ),composed of ginsenoside,penex notogingseng and berberin,on tumor growth and metastasis and to explore its mechanism.METHODS:Murine Lewis lung carcinoma transplant model was established and mice were treated with YHJ by intraperitoneal injection.After 10 days,the inhibitory rate of tumor,pathology of tumor and PCNA of tumor cells were detected.After 20 days,numbers of metastatic foci on lung surface and microvessel density(MVD)were determined.Expression of VEGF in tumor and serum were also analyzed by immunohistochemical test and ELISA,respectively.RESULTS:YHJ reduced the weight of tumor and the amount of metastatic foci.The inhibitory rates of tumor at high and low dose of YHJ(24 mg?kg-1?d-1,12 mg?kg-1?d-1)were 48.29% and 37.26%,and the number of metastatic foci was 1.67 and 3.50,while control was 6.44.Furthermore,PCNA of tumor cells,MVD of tumor and VEGF expression in serum and tumor were decreased in YHJ treatment goup as compared with control.CONCLUSION:YHJ remarkably inhibits Lewis lung carcinoma growth and metastasis in mice.Its mechanism may be related to inhibition of angiogenesis.

Result Analysis
Print
Save
E-mail