1.Mechanical properties and clinical application of femoral neck system
Haiming SA ; Zhiqiang MA ; Yushan MAIMAIAILI· ; Yifei HUANG ; Tuoliewuhan WUYILAHAN· ; Jiang ZHU ; Wu XU ; Tao LI ; Gang LYU
Chinese Journal of Orthopaedic Trauma 2024;26(6):499-504
The principles for surgical treatment of femoral neck fracture are anatomical reduction, rigid fixation and reduction of iatrogenic tissue damage to maintain sufficient blood supply and reduce the risk of complications such as avascular necrosis of the femoral head. In the evolution of internal fixation structures for femoral neck fracture, a variety of new products have been developed, such as the neck-shaft angle stabilization structure represented by dynamic hip screw, the multi-screw structure represented by three cannulated screws, and the plate-screw structure represented by multi-screw structure combined with a locked plate. These internal fixation structures have their own advantages and disadvantages in terms of stability and reduced risk of complications. However, none of them can perfectly meet the requirements of all the surgical principles. Femoral neck system (FNS) was firstly applied in clinic practice in 2017 to further improve the internal fixation of femoral neck fracture. In recent years, its mechanical properties and clinical effects have been widely reported in an attempt to further improve the implantation of this internal fixation device. This article reviews the researches on the mechanical properties and clinical efficacy of FNS and the suggestions put forward by orthopedic surgeons to improve the implantation methods of FNS.
2.Transesophageal echocardiography for guiding left atrial appendage closure with LAmbre occluder
Meng ZHANG ; Wen HE ; Lijuan DU ; Tingyu LAN ; Yifei LYU ; Huiqin ZHANG ; Fengxia DUAN ; Wei ZHANG
Chinese Journal of Medical Imaging Technology 2024;40(2):177-181
Objective To observe the value of transesophageal echocardiography(TEE)for guiding left atrial appendage closure(LAAC)with LAmbre occluder.Methods Data of 40 non-valvular atrial fibrillation(NVAF)patients who underwent LA AC with LAmbre occluder were retrospectively analyzed.CT angiography(CTA)before treatment,TEE and digital subtraction angiography(DSA)findings during LAAC were comparatively observed,and the correlations of the anchor area diameter and left atrial appendage opening diameter measured with the above three as well as occluder size were analyzed,and TEE and DSA for evaluating peri-device leak(PDL)were compared.Results LAAC were successfully performed with LAmbre occlude in all 40 cases.The diameter of the fixed umbrella was positively correlated with anchor area diameter measured with CTA,TEE and DSA(r=0.79,0.82,0.91,all P<0.01),of occlusion umbrella was positively correlated with left atrial appendage opening diameter measured with CTA,TEE and DSA(r=0.56,0.89,0.86,all P<0.01).Immediately after the release of occluder in LAAC,PDL occurred in 16 cases and were detected with both TEE and DSA,while in the rest 24 cases no PDL was found with neither TEE nor DSA.Conclusion TEE had comparable value to DSA for guiding LAAC using LAmbre occluder.
3.A digital anatomy study of the secure corridor for infra-acetabular screw placement
Gang LYU ; Chao MA ; Zhiqiang MA ; Yushan MAIMAIAILI ; Haiming SA ; Jiang ZHU ; Tuoliewuhan WUYILAHAN ; Yifei HUANG
Chinese Journal of Orthopaedic Trauma 2024;26(3):209-214
Objective:To compare the parameters for infra-acetabular screw placement between men and women using a digital Chinese anatomical model of the pelvis and acetabulum.Methods:The normal pelvic CT data were collected from the 163 adult patients who had been admitted to the Traditional Chinese Medicine Hospital of Xinjiang Uygur Autonomous Region from January 2018 to December 2021. There were 61 males and 102 females with an age of 53.0 (45.0, 60.0) years. Mimics 21.0 software was used to reconstruct the three dimensional pelvis which was then imported into Autodesk maya 2022 software before the model was flattened. Polygonal modeling tools were used to create a cylinder to simulate an infra-acetabular screw for length and angle measurements of the screw. The diameters of the infra-acetabular screws were measured by axial fluoroscopy in Mimics 21.0 software. The maximum diameters and maximum lengths of the infra-acetabular bone channel were compared between males and females, and the angles between the axis of the infra-acetabular screw and the anterior pelvic plane and the median sagittal plane were also compared between genders.Results:The maximum diameters of the left and right infra-acetabular corridors were 5.24 (4.26, 6.38) mm and 5.04 (4.50, 6.57) mm in males, and 3.99 (3.81, 4.51) mm and 3.89 (3.65, 4.90) mm in females; the maximum lengths of the left and right infra-acetabular corridors were (98.43±4.42) mm and (98.01±5.08) mm in males and 87.73 (84.22, 90.98) mm and 87.51 (84.59, 90.15) mm in females. The left and right angles between the infra-acetabular screw axis and the median sagittal plane were -0.98°±4.79° and -1.08°±4.91° in men, and 6.20° (3.34°, 11.16°) and 6.44° (3.77°, 11.85°) in women. The differences in the above data between men and women were statistically significant ( P<0.05). There was no statistically significant difference between men and women in the angle between the infra-acetabular screw axis and the anterior pelvic plane ( P>0.05). Conclusions:The length and diameter of the infra-acetabular corridor in males are greater than those in females, the angle between the infra-acetabular corridor and the sagittal plane in males is smaller than that in females, and the infra-acetabular corridor in males is more parallel to the sagittal plane. Therefore, the fluoroscopy angle should be adjusted for males to reduce the difficulty in screw placement when an infra-acetabular screw is placed during surgery.
4.Immunogenicity, safety and immune persistence of the sequential booster with the recombinant protein-based COVID-19 vaccine (CHO cell) in healthy people aged 18-84 years
Dingyan YAO ; Yingping CHEN ; Fan DING ; Xiaosong HU ; Zhenzhen LIANG ; Bo XING ; Yifei CAO ; Tianqi ZHANG ; Xilu WANG ; Yuting LIAO ; Juan YANG ; Huakun LYU
Chinese Journal of Preventive Medicine 2024;58(1):25-32
Objective:To evaluate the immunogenicity, safety, and immune persistence of the sequential booster with the recombinant protein-based COVID-19 vaccine (CHO cell) in healthy people aged 18-84 years.Methods:An open-label, multi-center trial was conducted in October 2021. The eligible healthy individuals, aged 18-84 years who had completed primary immunization with the inactivated COVID-19 vaccine 3 to 9 months before, were recruited from Shangyu district of Shaoxing and Kaihua county of Quzhou, Zhejiang province. All participants were divided into three groups based on the differences in prime-boost intervals: Group A (3-4 months), Group B (5-6 months) and Group C (7-9 months), with 320 persons per group. All participants received the recombinant COVID-19 vaccine (CHO cell). Blood samples were collected before the vaccination and after receiving the booster at 14 days, 30 days, and 180 days for analysis of GMTs, antibody positivity rates, and seroconversion rates. All adverse events were collected within one month and serious adverse events were collected within six months. The incidences of adverse reactions were analyzed after the booster.Results:The age of 960 participants was (52.3±11.5) years old, and 47.4% were males (455). The GMTs of Groups B and C were 65.26 (54.51-78.12) and 60.97 (50.61-73.45) at 14 days after the booster, both higher than Group A′s 44.79 (36.94-54.30) ( P value<0.05). The GMTs of Groups B and C were 23.95 (20.18-28.42) and 27.98 (23.45-33.39) at 30 days after the booster, both higher than Group A′s 15.71 (13.24-18.63) ( P value <0.05). At 14 days after the booster, the antibody positivity rates in Groups A, B, and C were 91.69% (276/301), 94.38% (302/320), and 93.95% (295/314), respectively. The seroconversion rates in the three groups were 90.37% (272/301), 93.75% (300/320), and 93.31% (293/314), respectively. There was no significant difference among these rates in the three groups (all P values >0.05). At 30 days after the booster, antibody positivity rates in Groups A, B, and C were 79.60% (238/299), 87.74% (279/318), and 90.48% (285/315), respectively. The seroconversion rates in the three groups were 76.92% (230/299), 85.85% (273/318), and 88.25% (278/315), respectively. There was a significant difference among these rates in the three groups (all P values <0.001). During the sequential booster immunization, the incidence of adverse events in 960 participants was 15.31% (147/960), with rates of about 14.38% (46/320), 17.50% (56/320), and 14.06% (45/320) in Groups A, B, and C, respectively. The incidence of adverse reactions was 8.02% (77/960), with rates of about 7.50% (24/320), 6.88% (22/320), and 9.69% (31/320) in Groups A, B, and C, respectively. No serious adverse events related to the booster were reported. Conclusion:Healthy individuals aged 18-84 years, who had completed primary immunization with the inactivated COVID-19 vaccine 3 to 9 months before, have good immunogenicity and safety profiles following the sequential booster with the recombinant COVID-19 vaccine (CHO cell).
5.Teriparatide treatment for osteoporosis:a rapid health technology assessment
Peng LYU ; Jingli ZHANG ; Yuansheng WAN ; Yifei HUANG ; Ruxu YOU
Chinese Journal of Pharmacoepidemiology 2024;33(1):75-84
Objective To evaluate the efficacy,safety and economy of teriparatide in the treatment of osteoporosis.Methods PubMed,Embase,Cochrane Library,Web of Science,CNKI,WanFang Data,VIP databases and websites related to health technology evaluation were systematically searched to collect high-quality clinical evidence and economic evaluation literature of teriparatide in the treatment of osteoporosis from the inception to January 20,2023.Two researchers independently identified studies,extracted data,assessed the quality of included studies,and descriptive analyzed and summarised the results.Results A total of 25 literatures were included,involving 3 HTA reports,15 systematic review/Meta-analyses and 7 economic studies were included.In terms of effectiveness,the evaluation results showed that teriparatide could improve bone mineral density in patients with osteoporosis,reduce the incidence of vertebral/non-vertebral fractures in primary and secondary osteoporosis and prevent the fractures in postmenopausal osteoporosis compared to bisphosphonates and placebos.In terms of safety,teriparatide was proven to be safe with no elevated risk of adverse drug reactions.In terms of economic cost,teriparatide has a higher cost and economic disadvantage compared with bisphosphonates,however,for people with severe postmenopausal osteoporosis and high risk of fracture,teriparatide can be considered as a potential cost-effect treatment option.Conclusion Teriparatide is effective and safe in the treatment of osteoporosis,but it is not cost-effective advantages compared with the existing other anti-osteoporosis medications.
6.A study on quantification assessment of segmental volume after thigh liposuction with three-dimensional scanning technology
Yifei LI ; Zhifeng LI ; Yunpeng GU ; Yicheng LIU ; Qianwen LYU ; Jingjing SUN ; Yue QI ; Guie MA
Chinese Journal of Plastic Surgery 2024;40(6):597-604
Objective:To investigate the quantification assessment of segmental volume after thigh liposuction utilizing three-dimensional(3D) scanning technology.Methods:This retrospective study was performed with the analysis of 3D scanning images of patients who had undergone bilateral thigh liposuction in Body Contouring & Fat Grafting Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences from January 2018 to September 2022. Preoperative and postoperative 3D scanning were performed to build visual 3D models of bilateral thighs. From top to the bottom, bilateral thighs were segmented into seven sections with a space of 5 cm in acquired 3D model. Certain measurements and calculation of preoperative and postoperative volume and volume change rate of the overall thigh and each segment were conducted, to validate the efficiency of liposuction (EOL). Additionally, EOL of each thigh segment was computed and the symmetry of bilateral thighs was analyzed before and after surgery. The volume differences were computed using the paired Wilcoxon rank-sum test, and intraclass correlation coefficient (ICC) was exerted to assess the symmetry of bilateral thighs before and after surgery.Results:A total of 36 female patients were included in the study, with an age range of 18 to 49 years and a mean age of (28.6±7.6) years. Follow-up duration ranged from 23 to 1 133 days postoperatively, with a mean follow-up period of 274.7 days. The results of 3D scanning measurements indicated significant changes ( P<0.01) in both the overall volume of the thigh and the volumes of each segment before and after surgery. The highest volume change rate and EOL were observed in the uppermost segment, and the volumetric change rate and EOL exhibited a descending trend across the segments of the thigh from the uppermost to the lowermost segments. The ICC of the volume of each segment consistently surpassed 0.950 whether preoperatively or postoperatively, indicating a high level of symmetry between the bilateral thighs, and the ICC of overall volume showed a notable increase from 0.992 preoperatively to 0.997 postoperatively. Conclusion:3D scanning technology can be exerted to quantify the volume changes before and after thigh liposuction. This study provided quantitative and objective evidence to confirm the efficacy of thigh liposuction procedure, elucidating that the most significant liposuction effects observed in the uppermost segment of the thigh. Moreover, postoperative assessments reveal a further enhancement in bilateral thigh symmetry.
7.A study on quantification assessment of segmental volume after thigh liposuction with three-dimensional scanning technology
Yifei LI ; Zhifeng LI ; Yunpeng GU ; Yicheng LIU ; Qianwen LYU ; Jingjing SUN ; Yue QI ; Guie MA
Chinese Journal of Plastic Surgery 2024;40(6):597-604
Objective:To investigate the quantification assessment of segmental volume after thigh liposuction utilizing three-dimensional(3D) scanning technology.Methods:This retrospective study was performed with the analysis of 3D scanning images of patients who had undergone bilateral thigh liposuction in Body Contouring & Fat Grafting Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences from January 2018 to September 2022. Preoperative and postoperative 3D scanning were performed to build visual 3D models of bilateral thighs. From top to the bottom, bilateral thighs were segmented into seven sections with a space of 5 cm in acquired 3D model. Certain measurements and calculation of preoperative and postoperative volume and volume change rate of the overall thigh and each segment were conducted, to validate the efficiency of liposuction (EOL). Additionally, EOL of each thigh segment was computed and the symmetry of bilateral thighs was analyzed before and after surgery. The volume differences were computed using the paired Wilcoxon rank-sum test, and intraclass correlation coefficient (ICC) was exerted to assess the symmetry of bilateral thighs before and after surgery.Results:A total of 36 female patients were included in the study, with an age range of 18 to 49 years and a mean age of (28.6±7.6) years. Follow-up duration ranged from 23 to 1 133 days postoperatively, with a mean follow-up period of 274.7 days. The results of 3D scanning measurements indicated significant changes ( P<0.01) in both the overall volume of the thigh and the volumes of each segment before and after surgery. The highest volume change rate and EOL were observed in the uppermost segment, and the volumetric change rate and EOL exhibited a descending trend across the segments of the thigh from the uppermost to the lowermost segments. The ICC of the volume of each segment consistently surpassed 0.950 whether preoperatively or postoperatively, indicating a high level of symmetry between the bilateral thighs, and the ICC of overall volume showed a notable increase from 0.992 preoperatively to 0.997 postoperatively. Conclusion:3D scanning technology can be exerted to quantify the volume changes before and after thigh liposuction. This study provided quantitative and objective evidence to confirm the efficacy of thigh liposuction procedure, elucidating that the most significant liposuction effects observed in the uppermost segment of the thigh. Moreover, postoperative assessments reveal a further enhancement in bilateral thigh symmetry.
8.Quantitative analysis of cervical vertebral maturation in Chinese adolescents based on three-dimensional morphology of cervi-cal vertebrae
Yue WU ; Wen TANG ; Yuyanran ZHANG ; Weiyu YUAN ; Yifei PAN ; Xinyu CHEN ; Haiyang XU ; Yunfan LYU ; Iman IZADIKHAH ; Dan CAO ; Lizhe XIE ; Bin YAN
STOMATOLOGY 2024;44(5):321-328
Objective To investigate associations between three-dimensional(3D)morphology of cervical vertebrae and skeletal mat-uration by cone-beam computed tomography(CBCT)and establish corresponding regression models for quantitatively evaluating cervical vertebral maturation(CVM).Methods The analyzed sample consisted of 358 CBCT images(175 male,183 female),of which 277 images were randomly selected as the model development group and 81 as the performance test group.Twenty-one 3D morphological pa-rameters were defined and measured,incorporating all parts of the cervical vertebrae,including the cervical vertebral bodies,transverse processes,spinous processes,pedicles,lamina,and articular processes.The cervical vertebral maturation index(CVMI)was determined by experienced orthodontists as reference standard.Spearman's rank correlation coefficient and multivariable stepwise regression analysis were used to identify the associations and build regression models.The performance test group was employed to ex-amine each model's reliability.Paired-samples Wilcoxon signed-rank test compared the CVMI of the model prediction with the reference standard.Results Three-dimensional morphological changes in various parts of the cervical vertebrae correlated with CVMI(P<0.05).Six 3D morphometric parameters were each recognized for male and female models,three of which were identical.The adjusted R2 was 0.899 for males and 0.902 for females,with corresponding accuracies of 85.0%and 85.4%,respectively.These models showed no difference as compared with the reference standard(P>0.05).Con-clusion New associations were found between 3D morphology of cer-vical vertebrae and skeletal maturation.The 3D-driven morphometric CVM assessment method and corresponding regression models exhibited good credibility and high consistency with experts.
9.Three-dimensional digital anatomical morphology of secure corridor for infra-acetabular screw
Gang LYU ; Chao MA ; Zhiqiang MA ; Yushan MAIMAIAILI ; Yifei HUANG
Chinese Journal of Orthopaedics 2024;44(7):430-437
Objective:To establish a digital anatomical model of the pelvic and compare the differences in morphological parameters of the infra-acetabular screw safety channel between men and women.Methods:A retrospective analysis was performed on the pelvic data of 106 normal adults who underwent plain pelvic CT scan for non-pelvic disorders diseases in the Affiliated Hospital of Traditional Chinese Medicine of Xinjiang Medical University from January 2022 to December 2022, including 56 males and 50 females, aged 50.58±11.22 years (range, 21-68 years). Use reverse reconstruction software to reconstruct the pelvis and import it into Autodesk maya 2022 software to level the model. Use polygonal modeling tools to simulate the insertion of infra-acetabular screws and measure the length of the screw, the screw insertion angle, and the distance between the needle entry point and the apex of the iliopubic eminence. Measure the diameter of the infra-acetabular screw through axial fluoroscopy; measure the needle entry area, narrow area and needle exit area in Mimics 21.0 software; compare the differences in the above indicators between men and women.Results:The maximum diameters of male and female infra-acetabular screws were 4.82±1.07 mm and 3.93±0.65 mm respectively; the maximum lengths were 97.74±93.8 mm and 88.23±4.55 mm respectively; the angles with the sagittal plane were -1.33°±4.96°and 7.29°±6.20° respectively; the needle insertion areas were 314.83±4.79 mm 2 and 198.29±78.70 mm 2 respectively, the narrow areas were 75.61±19.00 mm 2 and 47.33±13.34 mm 2 respectively, and the needle exit areas were 400.52±88.86 mm 2 and 268.27±120.71 mm 2 respectively; the differences between male and female were statistically significant ( P<0.05). The infra-acetabular screw insertion points for men and women are respectively 9.39±1.44 mm and 9.68±1.41 mm inside the iliopubic eminence apex, and 8.87±1.22 mm and 9.28±1.56 anterior to the iliopubic eminence apex; the angles between the infra-acetabular screw and the anterior pelvic plane were 52.69°±7.38°and 52.32°±1.24°respectively; the differences were not statistically significant ( P>0.05). When the screw diameter was 3.5 mm, 88% (49/56) of men and 76% (38/50) of women have corridor in the pelvis for screws to pass through, and the difference was not statistically significant (χ 2=2.375, P=0.123). But when the screw diameter was 4.5 mm, 59% (33/56) of men and 20% (10/50) of women have corridor in the pelvis for screws to pass through, and the difference was statistically significant (χ 2=16.603, P<0.001). Conclusion:There are large individual differences in infra-acetabular corridor parameters. The length, diameter, needle entry area, narrow area and needle exit area of the infra-acetabular screw in men are larger than those in women, while the angle with the sagittal plane in men is smaller than that in women. There is no significant difference between men and women in the distance between the insertion point of the infra-acetabular screw and the iliopubic eminence and the angle between the screw and the anterior pelvic plane. There was no significant difference in the pass rate of screws with a diameter of 3.5 mm between males and females in the acetabular canal, while the pass rate of screws with a diameter of 4.5 mm was higher than that of females.
10.A case report of elderly patient with refractory severe aplastic anemia by treatment of avatrombopag in combination with tacrolimus
Baozhi FANG ; Yifei ZHOU ; Qiudan SHEN ; Muzhi YUAN ; Xiao YU ; Peng WANG ; Ming'en LYU
Journal of Clinical Medicine in Practice 2024;28(3):105-108
Objective To summarize the clinical effect and adverse reactions of avatrombopag combined with tacrolimus in the treatment of elderly patient with refractory severe aplastic anemia. Methods An elderly patient with refractory severe aplastic anemia was treated with avatrombopag and tacrolimus, and the literature review on the mechanism of action and safety of avatrombopag and tacrolimus was conducted. Results The patient was treated with a combination of cyclosporine, testosterone undecanoate, and itraconazole for 6 months without success, and developed liver and kidney dysfunction. The medication was discontinued, and the patient was treated with a combination of avatrombopag (20 mg, once per day) and tacrolimus (1 mg, twice per day). After 9 months of treatment, the patient's platelet count increased to 54×109/L, the hemoglobin increased to 124 g/L, the white blood cells increased to 8.23×109/L, liver and kidney function also returned to normal level, and no other adverse reactions such as thrombotic events were observed. After treatment, CD4/CD8 decreased, CD8+ T cells increased, and the proportion of Treg cells increased as well. Conclusion The combination of avatrombopag and tacrolimus is effective and well tolerated in the treatment of elderly patient with refractory aplastic anemia, but the long-term follow-up observation and continued accumulation of cases are still needed in the future.


Result Analysis
Print
Save
E-mail