1.The efficacy of ultrasound-guided genicular nerve block in treating knee osteoarthritis
Fanxiang FENG ; Hai SHEN ; You LI ; Kai REN ; Fulong LIU ; Yicheng XIAO ; Weixia ZHAO ; Xin ZHANG
Chinese Journal of Physical Medicine and Rehabilitation 2025;47(9):834-840
Objective:To document the effectiveness of ultrasound-guided genicular nerve block (GNB) in treating knee osteoarthritis (KOA).Methods:A total of 92 KOA patients were randomly divided into an observation group and a control group with 46 in each. Those in both groups were treated conventionally, including with non-steroidal anti-inflammatory drugs, acupuncture, ultrasound, laser irradiation and manipulation therapy. The observation group additionally underwent ultrasound-guided genicular nerve block treatment, once a week for 2 weeks. Pain scoring on a visual analog scale (VAS), the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and a 6-minute walk test (6MWT) were used to evaluate everyone before and after the treatment, and then 8 weeks later.Results:In the observation group the average VAS rating [(3.54±2.00) at week 2 and (4.13±2.04) at week 8] and the average WOMAC subscale and total scores [(36.91±16.91) at week 8] had improved significantly right after the experiment and 8 weeks later. But in the control group this was true only right after the treatment. The observation group also demonstrated superior improvements in 6MWT distance at week 2 [(434.22±125.19)m] and week 8 [(446.35±126.45)m] compared to both its own baseline and the control group.Conclusions:Ultrasound-guided genicular nerve block is a rapid, precise, effective, and long-lasting intervention for alleviating pain, improving knee function and enhancing walking endurance in KOA patients.
2.Preparation and performance evaluation of large diameter artificial vessels modified with polydopamine/gelatin/earthworm active protein
Xin FENG ; Xinyu PAN ; Xuewei ZHANG ; Xiao LIU ; Ziwei ZHAO ; Yicheng LI ; Tuo YANG ; Wentao LI ; Liang ZHAO ; Wenbin LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(5):284-294
Objective:To investigate a novel coating technology for artificial blood vessel pipelines, conducting preliminary tests on the mechanical stability, hemocompatibility, and biocompatibility of the coating.Methods:The polyester braided artificial blood vessels produced by Terumo Corporation were subjected to three different experimental treatments and divided into three groups. Model group: The uncoated artificial blood vessels were thoroughly cleaned and freeze-dried. Experimental group: The artificial blood vessels were first immersed in a dopamine solution to form a polydopamine(PDA) coating on their surface, and then further immersed in an earthworm active protein/gelatin(EWAP/GT) solution to create PDA/GT/EWAP-modified artificial blood vessels. Collagen group: The untreated polyester woven artificial blood vessels served as the control. The study detailed the characterization, porosity, water permeability, degradation rate, blood compatibility, and cytotoxicity of the PDA/GT/EWAP-coated artificial blood vessels. Additionally, a 2-week in vivo study was conducted to evaluate the biocompatibility of the PDA/GT/EWAP-coated artificial blood vessels implanted subcutaneously in SD rats.Results:The PDA/GT/EWAP-coated artificial vascular grafts were successfully fabricated. The artificial blood vessels in the PDA/GT/EWAP group exhibited a porosityof(50.53±1.10)%, with water permeability showing a gradual decreasing trend over time. The overall in vitro degradation rate at 4 weeks was(1.83±0.08)%, and the PDA/GT/EWAP group demonstrated favorable mechanical stability. The activated partial thromboplastin time(APTT) of the PDA/GT/EWAP group was(26.30±0.46)s, the thrombin time(TT) was(18.83±0.49)s, the hemolysis rate was(2.15±0.09)%, and the plasma recalcification time(PRT) was(191.00±10.54)s, indicating excellent blood compatibility and anticoagulant properties. MTT assay evaluation of the PDA/GT/EWAP group revealed no significant cytotoxicity. After subcutaneous implantation of vascular samples in rats for 2 weeks, analysis of blood immune parameters and hematoxylin-eosin(HE) staining of the artificial vascular samples showed that the immune response in the PDA/GT/EWAP group exhibited no significant difference compared to the collagen group and was superior to the model group. Conclusion.Conclusion:The PDA/GT/EWAP composite-coated artificial blood vessel demonstrates excellent mechanical properties, good hemocompatibility, biocompatibility, and low cytotoxicity. It also shows remarkable stability. This research offers a new approach for domestic technological breakthroughs in related fields.
3.The efficacy of ultrasound-guided genicular nerve block in treating knee osteoarthritis
Fanxiang FENG ; Hai SHEN ; You LI ; Kai REN ; Fulong LIU ; Yicheng XIAO ; Weixia ZHAO ; Xin ZHANG
Chinese Journal of Physical Medicine and Rehabilitation 2025;47(9):834-840
Objective:To document the effectiveness of ultrasound-guided genicular nerve block (GNB) in treating knee osteoarthritis (KOA).Methods:A total of 92 KOA patients were randomly divided into an observation group and a control group with 46 in each. Those in both groups were treated conventionally, including with non-steroidal anti-inflammatory drugs, acupuncture, ultrasound, laser irradiation and manipulation therapy. The observation group additionally underwent ultrasound-guided genicular nerve block treatment, once a week for 2 weeks. Pain scoring on a visual analog scale (VAS), the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and a 6-minute walk test (6MWT) were used to evaluate everyone before and after the treatment, and then 8 weeks later.Results:In the observation group the average VAS rating [(3.54±2.00) at week 2 and (4.13±2.04) at week 8] and the average WOMAC subscale and total scores [(36.91±16.91) at week 8] had improved significantly right after the experiment and 8 weeks later. But in the control group this was true only right after the treatment. The observation group also demonstrated superior improvements in 6MWT distance at week 2 [(434.22±125.19)m] and week 8 [(446.35±126.45)m] compared to both its own baseline and the control group.Conclusions:Ultrasound-guided genicular nerve block is a rapid, precise, effective, and long-lasting intervention for alleviating pain, improving knee function and enhancing walking endurance in KOA patients.
4.Preparation and performance evaluation of large diameter artificial vessels modified with polydopamine/gelatin/earthworm active protein
Xin FENG ; Xinyu PAN ; Xuewei ZHANG ; Xiao LIU ; Ziwei ZHAO ; Yicheng LI ; Tuo YANG ; Wentao LI ; Liang ZHAO ; Wenbin LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(5):284-294
Objective:To investigate a novel coating technology for artificial blood vessel pipelines, conducting preliminary tests on the mechanical stability, hemocompatibility, and biocompatibility of the coating.Methods:The polyester braided artificial blood vessels produced by Terumo Corporation were subjected to three different experimental treatments and divided into three groups. Model group: The uncoated artificial blood vessels were thoroughly cleaned and freeze-dried. Experimental group: The artificial blood vessels were first immersed in a dopamine solution to form a polydopamine(PDA) coating on their surface, and then further immersed in an earthworm active protein/gelatin(EWAP/GT) solution to create PDA/GT/EWAP-modified artificial blood vessels. Collagen group: The untreated polyester woven artificial blood vessels served as the control. The study detailed the characterization, porosity, water permeability, degradation rate, blood compatibility, and cytotoxicity of the PDA/GT/EWAP-coated artificial blood vessels. Additionally, a 2-week in vivo study was conducted to evaluate the biocompatibility of the PDA/GT/EWAP-coated artificial blood vessels implanted subcutaneously in SD rats.Results:The PDA/GT/EWAP-coated artificial vascular grafts were successfully fabricated. The artificial blood vessels in the PDA/GT/EWAP group exhibited a porosityof(50.53±1.10)%, with water permeability showing a gradual decreasing trend over time. The overall in vitro degradation rate at 4 weeks was(1.83±0.08)%, and the PDA/GT/EWAP group demonstrated favorable mechanical stability. The activated partial thromboplastin time(APTT) of the PDA/GT/EWAP group was(26.30±0.46)s, the thrombin time(TT) was(18.83±0.49)s, the hemolysis rate was(2.15±0.09)%, and the plasma recalcification time(PRT) was(191.00±10.54)s, indicating excellent blood compatibility and anticoagulant properties. MTT assay evaluation of the PDA/GT/EWAP group revealed no significant cytotoxicity. After subcutaneous implantation of vascular samples in rats for 2 weeks, analysis of blood immune parameters and hematoxylin-eosin(HE) staining of the artificial vascular samples showed that the immune response in the PDA/GT/EWAP group exhibited no significant difference compared to the collagen group and was superior to the model group. Conclusion.Conclusion:The PDA/GT/EWAP composite-coated artificial blood vessel demonstrates excellent mechanical properties, good hemocompatibility, biocompatibility, and low cytotoxicity. It also shows remarkable stability. This research offers a new approach for domestic technological breakthroughs in related fields.
5.Association between plasma growth differentiation factor 15 levels and pre-eclampsia in China
Shuhong XU ; Yicheng LU ; Mengxin YAO ; Zhuoqiao YANG ; Yan CHEN ; Yaling DING ; Yue XIAO ; Fei LIANG ; Jiani QIAN ; Jinchun MA ; Songliang LIU ; Shilan YAN ; Jieyun YIN ; Qiuping MA
Chronic Diseases and Translational Medicine 2024;10(2):140-145
Background::Growth differentiation factor-15 (GDF-15) is a stress response protein and is related to cardiovascular diseases (CVD). This study aimed to investigate the association between GDF-15 and pre-eclampsia (PE).Method::The study involved 299 pregnant women, out of which 236 had normal pregnancies, while 63 participants had PE. Maternal serum levels of GDF-15 were measured by using enzyme-linked immunosorbent assay kits and then translated into multiple of median (MOM) to avoid the influence of gestational week at blood sampling. Logistic models were performed to estimate the association between GDF-15 MOM and PE, presenting as odd ratios (ORs) and 95% confidence intervals (CIs).Results::MOM of GDF-15 in PE participants was higher compared with controls (1.588 vs. 1.000, p < 0.001). In the logistic model, pregnant women with higher MOM of GDF-15 (>1) had a 4.74-fold (95% CI= 2.23-10.08, p < 0.001) increased risk of PE, adjusted by age, preconceptional body mass index, gravidity, and parity. Conclusions::These results demonstrated that higher levels of serum GDF-15 were associated with PE. GDF-15 may serve as a biomarker for diagnosing PE.
6.Comparing the efficacies of different treatments for T lymphoblastic lymphoma
Andie FU ; Xiaojian ZHU ; Yang YANG ; Lifang HUANG ; Jinhuan XU ; Yang CAO ; Yi XIAO ; Fankai MENG ; Donghua ZHANG ; YiCheng ZHANG
Chinese Journal of Organ Transplantation 2024;45(2):75-81
Objective:To explore the differential efficacies of conventional chemotherapy, autologous hematopoietic stem cell transplantation (auto-HSCT) and allogeneic hematopoietic stem cell transplantation (allo-HSCT) for T lymphoblastic lymphoma (T-LBL) .Method:From January 2012 to December 2022, the relevant clinical data were retrospectively reviewed for 82 T-LBL patients hospitalized at Affiliated Tongji Hospital. According to different treatments, they were assigned into two groups of non-transplantation (49 cases) and transplantation (33 cases). The transplantation group was divided further into two groups of allo-HSCT (22 cases) and auto-HSCT (11 cases) according to different transplantation modes. In non-transplantation group, remission was induced mostly by cyclophosphamide+messosodium+doxorubicin+dexamethasone+vincrine/methotrexate+Hyper CAVD A/B. Six patients achieved remission based upon cyclophosphamide+cytarabine+6-mercaptopurine (CAT), etoposide+vincristine+doxorubicin+cyclophosphamide+cyclophosphamide+ prednisone (EPOCH), high-dose methotrexate+dexamethasone and vincristine+pirubicin+ cyclophosphamide+ pemasase+prednisone (VDCLP). The transplantation group underwent HSCT after multi-drug combination intensive induction therapy. Efficacy and survival were analyzed by observing the rates of overall survival (OS) and progression-free survival (PFS) .Result:There were 64 males and 18 females with a median age of 23 (11~74) year. Among them, 62 cases (75.61%) had clinical stage Ⅲ~Ⅳ. And 43 cases (53.44%) had systemic symptoms (B symptom) of fever, night sweats and weight loss at an onset of disease. Fifty cases (61.00%) had an involvement of bone marrow and 33 cases (80.5%) belonged to Ann Arbor stage Ⅲ and above. There were 65 cases (79.27%) with Eastern Cooperative Oncology Group (ECOG) score ≤2 and 17 cases (20.73%) with ECOG score >2. International Prognostic Index (IPI) was ≤3 (63 cases, 76.83%) and >3 (19 cases, 23.17%). Follow-up period was 27.5 (5~118) month. And 3-year OS and PFS were 53.64% (95% CI: 42.35%~64.62%) and 47.56% (95% CI: 36.53%~58.82%). Significant inter-group difference existed in 3-year OS[42.86% (95% CI: 29.12%~57.71%) vs 69.70% (95% CI: 51.13%~83.79%), P=0.014]and 3-year PFS was 38.76% (95% CI: 25.54%~53.76%) and 60.61% (95% CI: 42.24%~76.57%). And the difference was statistically significant ( P=0.032) . Conclusion:As a consolidation therapy, HSCT may improve the long-term outcomes of T-LBL patients as compared with chemotherapy alone.
7.Properties of gelatin-polyethylene glycol hydrogel loaded with silver nanoparticle Chlorella and its effects on healing of infected full-thickness skin defect wounds in mice
Zhenzhen YAN ; Yuxiang WANG ; Tinglin ZHANG ; Jingnan XUN ; Yicheng MA ; Chao JI ; Jie GAO ; Shichu XIAO
Chinese Journal of Burns 2024;40(1):33-42
Objective:To explore the properties of gelatin-polyethylene glycol hydrogel loaded with silver nanoparticle (AgNP) Chlorella (hereinafter referred to as the composite hydrogel) and its effects on healing of infected full-thickness skin defect wounds in mice. Methods:The research was an experimental research. The simple gelatin-polyethylene glycol hydrogel (hereinafter referred to as the simple hydrogel) and the composite hydrogel were prepared, and the appearance and injectability of the two hydrogels were observed at 55 and 37 ℃, and under the irradiation of 808 nm near-infrared light, respectively. An electronic universal testing machine was employed to assess the tensile and compressive stress-strain properties of both types of hydrogels at room temperature. Additionally, the cyclic compressive stress-strain properties of the composite hydrogel were examined at 80% of the maximum compressive stress. Staphylococcus aureus or Escherichia coli solution was added to phosphate buffer solution (PBS), simple hydrogel, and composite hydrogel, respectively. The part of composite hydrogel containing Staphylococcus aureus or Escherichia coli solution was irradiated with near-infrared light for 5 minutes. After each sample was incubated for 6 h, the dilution plating method was used to detect and calculate the mortality rates of the two bacteria at 24 h of culture ( n=5). The discarded foreskin tissue was taken from a 6-year-old healthy boy admitted to the Department of Urology of the First Affiliated Hospital of Naval Medical University for circumcision. Primary human fibroblasts (HFbs) were isolated using the enzyme extraction method, routinely cultured to the 3 rd to 6 th passages for subsequent cellular experiments. Composite hydrogel extracts with final mass concentrations of 100.0, 50.0, 25.0, 12.5, and 0 mg/mL were respectively prepared and used to culture HFbs, and the cell proliferation after 24 h of culture was detected using a cell counting kit 8 ( n=3). A total of twenty 6-8 weeks old C57BL/6J female mice were utilized, and a full-thickness skin defect was surgically created on the back of each mouse. The wounds were infected with Staphylococcus aureus solution. The infected mice were divided into blank control group, simple hydrogel group, composite hydrogel group, and combined treatment group according to the random number table, and the wounds were treated with PBS, simple hydrogel, composite hydrogel, and composite hydrogel+light irradiation (under the irradiation of 808 nm near-infrared light for 5 min), respectively, with 5 mice in each group. On post injury day (PID) 0 (immediately after the first wound treatment), 3, 7, and 14, an overall assessment of wound exudation and healing were conducted, and the wound healing rates on PID 7 and 14 were calculated ( n=5). On PID 14, hematoxylin-eosin staining was performed to observe histopathological changes in the mouse wound. Results:Both simple hydrogel and composite hydrogel were in a solution state at 55 ℃ and transition to a gel state when cooling to 37 ℃. After the two hydrogels were irradiated by near-infrared light, only the composite hydrogel reheated up and returned to the solution state again with injectability. The maximum tensile stress of the composite hydrogel was up to 301.42 kPa, with a corresponding strain of 87.19%; the maximum compressive stress was up to 413.79 kPa, with a corresponding strain of 91.67%, which was similar to the tensile and compressive properties of the simple hydrogel. After 10 compression cycles, the maximum compressive stress of the composite hydrogel still reached 84.1% of the first compressive stress. After 24 h of culture, the mortality rate of Staphylococcus aureus treated with simple hydrogel was significantly higher than that treated with PBS ( P<0.05); the mortality rates of Escherichia coli and Staphylococcus aureus treated with composite hydrogel alone were significantly higher than those treated with simple hydrogel ( P<0.05); the mortality rates of Escherichia coli and Staphylococcus aureus treated with composite hydrogel+light irradiation were significantly higher than those treated with composite hydrogel alone ( P<0.05). After 24 h of culture, compared with that cultured in composite hydrogel immersion solution with final mass concentration of 0 mg/mL, the proliferation activity of HFbs cultured in composite hydrogel immersion solution with final mass concentrations of 25.0 and 50.0 mg/mL was significantly enhanced ( P<0.05), while the proliferation activity of HFbs cultured in composite hydrogel immersion solution with final mass concentration of 100 mg/mL was significantly decreased ( P<0.05). On PID 0 and 3, more purulent secretions were seen in the wounds of mice in blank control group and simple hydrogel group, while only a small amount of exudate was observed in the wounds of mice in composite hydrogel group, and no obvious infection was observed in the wounds of mice in combined treatment group. On PID 7 and 14, the wound healing rates of mice in simple hydrogel group were significantly higher than those in blank control group ( P<0.05); the wound healing rates of mice in composite hydrogel group were significantly higher than those in simple hydrogel group ( P<0.05); the wound healing rates in combined treatment group were significantly higher than those in composite hydrogel group ( P<0.05). On PID 14, the wounds of mice in blank control group exhibited a high infiltration of inflammatory cells with no new epithelial layer observed; the wounds of mice in simple hydrogel group displayed a short length of newly formed epithelium with a small amount of inflammatory cells; the wounds of mice in composite hydrogel group exhibited continuous formation of new epithelium and a large amount of immature granulation tissue; the wounds of mice in combined treatment group showed continuous epithelialization with less immature granulation tissue. Conclusions:The prepared composite hydrogel exhibits excellent thermosensitivity, photothermal properties, and injectability, as well as excellent mechanical properties, antibacterial properties, and biocompatibility, and can promote the healing of infected full-thickness skin defect wounds in mice.
8.Study on the population genetic structure and phylogenetic relationship of the Han population in Dalian
Wenqian SONG ; Shihang ZHOU ; Nan XIAO ; Lingzi PAN ; Linnan SHAO ; Yuexin XIA ; Ying DUAN ; Yicheng YANG ; Chunxiang LI ; Weijian YU
Chinese Journal of Forensic Medicine 2024;39(1):88-93
Objective To study the population genetic structure and phylogenetic relationships by combining Y-STR haplotype genetic information from the Han population in Dalian with 32 domestic and foreign groups.Methods Blood samples of 958 Han male volunteers from Dalian were collected.Genetic typing of 42 genetic loci was completed using Y-STR fluorescent reagent kits and capillary electrophoresis.Related forensic parameters were calculated.Nei's standard genetic distances among 33 populations based on 17 Y-STR loci were computed,in order to create a principal coordinate analysis as well as construct a phylogenetic tree.Results The analysis of genetic polymorphisms at 42 Y-STR loci revealed 30 unconventional alleles at 10 loci.Genetic analysis of the population based on 17 Y-STR loci confirmed that Dalian's Han population had the closest genetic distance to the Anshan's Han population,followed by populations from Henan,Heilongjiang,Jilin,Shandong,and Chongqing.Furthermore,the genetic distances between the Han population in Dalian and the Qiang population in Beichuan or the Miao population in Guizhou were relatively closer than that to the Manchu population living in Liaoning.Conclusion The genetic distance between the Han population in Dalian and other groups is not entirely proportional to ethnicities and geographical proximity.Both population migration and ethnic assimilation or isolation may have influence on it.
9.Experimental Study on Biomimetic Curcumin-Mediated Sonodynamic Therapy of Melanoma
Xiao RONG ; Xi XIANG ; Yicheng ZHAO ; Li QIU ; Fangxue DU
Journal of Sichuan University (Medical Sciences) 2024;55(5):1159-1165
Objective To study the role of curcumin-mediated sonodynamic therapy in the treatment of malignant melanoma,and to provide a new strategy for the treatment of malignant melanoma.Methods The ultrasonic sound and vibration method was applied to coat curcumin with mouse melanoma cell membrane,thereby forming biomimetic curcumin.The morphology of biomimetic curcumin was observed by transmission electron microscope.Flow cytometry was used to analyze the effect of biomimetic curcumin in terms of in vitro targeting,apoptosis,and intracellular reactive oxygen species(ROS)production.The in vivo experiment was divided into control group,US group,turmeric group,imitation turmeric group,and imitation turmeric+US group,with 3 mice in each group.The in vivo safety of biomimetic curcumin was evaluated by HE staining.In addition,HE,CD31,Ki67,and TUNEL stainings were performed to evaluate the in vivo anti-melanoma therapeutic effect of ultrasound combined with biomimetic curcumin.Results The biomimetic curcumin had a generally uniform morphology and possessed a core-shell structure.Flow cytometry analysis performed with FlowJo showed that the biomimetic curcumin could be effectively taken up by melanoma cells.The apoptosis rate was(10.30±0.61)%in the control group,(10.41±3.13)%in the ultrasound group,(24.97±1.38)%in the curcumin group,(31.39±3.84)%in the biomimetic curcumin group,and(40.89±0.79)%in the biomimetic curcumin and ultrasound combination group.The apoptosis rate in the biomimetic curcumin and ultrasound combination group was higher than those in the other groups(P<0.05).The results of ROS flow cytometry showed that,compared with the control group,the ultrasound group demonstrated almost no increase in the fluorescence intensity,while the other groups showed an increase in the fluorescence intensity to varying degrees.There was no significant difference in the fluorescence intensity between the biomimetic curcumin group([1.10±0.38]%)and the curcumin group([0.73±0.26]%)(P>0.05).The fluorescence intensity of the biomimetic curcumin and ultrasound combination group([3.35±0.04]%)was higher than those of the other groups(P<0.05).HE staining showed no obvious abnormalities in the morphology of heart,liver,spleen,lung,and kidney tissues in any of the treatment groups.HE staining showed the most significant changes in cell morphology in the biomimetic curcumin and ultrasound combination group,followed by the biomimetic curcumin group and the curcumin group.No obvious abnormalities in tumor cell morphology were observed in the ultrasound group.According to the respective results of CD31 staining,Ki67 staining,and TUNEL staining,the biomimetic curcumin and ultrasound combination group had the largest brown area,the highest number of red fluorescence,and the highest number of green fluorescence,followed by the biomimetic curcumin group and the curcumin group.Conclusion The biomimetic curcumin displays uniform morphology,a core-shell structure,and good targeting properties.When it is used in combination with ultrasound,biomimetic curcumin demonstrates a good anti-tumor therapeutic effect both in vivo and in vitro.
10.Association between plasma growth differentiation factor 15 levels and pre-eclampsia in China
Shuhong XU ; Yicheng LU ; Mengxin YAO ; Zhuoqiao YANG ; Yan CHEN ; Yaling DING ; Yue XIAO ; Fei LIANG ; Jiani QIAN ; Jinchun MA ; Songliang LIU ; Shilan YAN ; Jieyun YIN ; Qiuping MA
Chronic Diseases and Translational Medicine 2024;10(2):140-145
Background::Growth differentiation factor-15 (GDF-15) is a stress response protein and is related to cardiovascular diseases (CVD). This study aimed to investigate the association between GDF-15 and pre-eclampsia (PE).Method::The study involved 299 pregnant women, out of which 236 had normal pregnancies, while 63 participants had PE. Maternal serum levels of GDF-15 were measured by using enzyme-linked immunosorbent assay kits and then translated into multiple of median (MOM) to avoid the influence of gestational week at blood sampling. Logistic models were performed to estimate the association between GDF-15 MOM and PE, presenting as odd ratios (ORs) and 95% confidence intervals (CIs).Results::MOM of GDF-15 in PE participants was higher compared with controls (1.588 vs. 1.000, p < 0.001). In the logistic model, pregnant women with higher MOM of GDF-15 (>1) had a 4.74-fold (95% CI= 2.23-10.08, p < 0.001) increased risk of PE, adjusted by age, preconceptional body mass index, gravidity, and parity. Conclusions::These results demonstrated that higher levels of serum GDF-15 were associated with PE. GDF-15 may serve as a biomarker for diagnosing PE.

Result Analysis
Print
Save
E-mail